996 resultados para Clinical Interpretation


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The paper presents the radiometric parameters determined by the medical physicist during routine radiotherapy planning service in cases of breast cancer . The contours of the breast volume in patients undergoing radiation breast tumors at the Hospital das Clinicas, Faculty of Medicine , UNESP, Botucatu ( HCFMB ) during the year 2012 were analyzed . In order to analyze the influence of physical and radiometric parameters for the determination of the dose distribution of irradiated breast volume , four measurements of isodose curves were prepared in four different heights breast , and compared with the isodose curves plotted computationally . In the routine of planning , the medical physicist must determine the isodose curve that gives the best dose distribution homogeneity in the irradiated volume . The choice of the treatment plan can be done by dedicated computer systems , which require significantly costly investments available services having better financial support . In the Service of Medical Physics , Department of Radiotherapy , HC FMB , we use a two-dimensional software for determination of isodose curves , however , this software is out of date and frequently becomes inoperable due to the lack of maintenance and it is a closed system without feasibility of interference from computer professionals . This fact requires manual preparation of isodose curves , which are subject to uncertainties due to the subjectivity in the clinical interpretation of medical radiation oncologist and medical physicist responsible for planning , plus dispendiar significant calculation time . The choice of the optimal isodose curve depends on the energy of the radiation beam , the geometry and dimensions of the irradiated area . The contours of the breast studied in this work evaluations showed that , for a given energy input , such as the energy of 1.25 MeV of gamma radiation Unit Telecobaltoterapia , the determination of the percentage depth dose ( PDP ) ...

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Purpose: The methodology currently used for interpretation of the cornea and anterior segment tomography for the diagnosis of corneal ectasia and its susceptibility. Methods: Description of the methodology and clinical interpretation of corneal and anterior segment tomography indexes; report of three cases demonstrating the importance of this new diagnostic tool (Pentacam HR (R)) in ophthalmological practice. Conclusion: The use of corneal and anterior segment tomography seems to be an effective method to increase the sensitivity and specificity for the diagnosis and early detection of corneal ectasia.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Golden conures or ararajubas (Guaruba guarouba) are endangered parrots endemic to the Brazilian Amazon forest. Body mass, blood cell counts, and total plasma protein were determined for 70 clinically healthy golden conures captive at zoologic parks and private breeder facilities in Brazil. Hematologic results (mean +/- SD) were: Erythrocytes 3.6 +/- 0.5 x 10(6) cells/mm(3), hemoglobin 12.8 +/- 1.4 g/dl, packed cell volume 46 +/- 3.8%, mean corpuscular volume 132 +/- 20 fl, mean corpuscular hemoglobin (MCH) 36 +/- 5.7 pg, mean corpuscular hemoglobin concentration (MCHC) 28 +/- 3.5%, thrombocytes 26.3 +/- 9.3 x 10(3) cells/mm(3), leukocytes 11.9 +/- 4.5 x 10(3) cells/mm(3), heterophils 6284 +/- 2715 cells/mm(3), lymphocytes 5473 +/- 2408 cells/mm(3), monocytes 113 +/- 162 cells/mm(3), eosinophils 10 +/- 42 cells/mm(3), basophils 27 +/- 64 cells/mm(3). Body mass was 254 +/- 24.9 g and total plasma protein (TPP) was 3.54 +/- 0.58 g/dl. No statistical differences were observed between genders within age groups. Differences between juveniles (J) and adults (A) were identified for TPP < A), MCH (J > A), and MCHC (J > A). These results provide reliable reference values for the clinical interpretation of hematologic results for the species. Hematology may be an important tool for population health investigations on free-ranging golden conure populations and will also be essential to survey the health of release candidates in future reintroduction programs.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background: In normal aging, the decrease in the syntactic complexity of written production is usually associated with cognitive deficits. This study was aimed to analyze the quality of older adults' textual production indicated by verbal fluency (number of words) and grammatical complexity (number of ideas) in relation to gender, age, schooling, and cognitive status. Methods: From a probabilistic sample of community-dwelling people aged 65 years and above (n = 900), 577 were selected on basis of their responses to the Mini-Mental State Examination (MMSE) sentence writing, which were submitted to content analysis; 323 were excluded as they left the item blank or performed illegible or not meaningful responses. Education adjusted cut-off scores for the MMSE were used to classify the participants as cognitively impaired or unimpaired. Total and subdomain MMSE scores were computed. Results: 40.56% of participants whose answers to the MMSE sentence were excluded from the analyses had cognitive impairment compared to 13.86% among those whose answers were included. The excluded participants were older and less educated. Women and those older than 80 years had the lowest scores in the MMSE. There was no statistically significant relationship between gender, age, schooling, and textual performance. There was a modest but significant correlation between number of words written and the scores in the Language subdomain. Conclusions: Results suggest the strong influence of schooling and age over MMSE sentence performance. Failing to write a sentence may suggest cognitive impairment, yet, instructions for the MMSE sentence, i.e. to produce a simple sentence, may limit its clinical interpretation.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The Chicago Classification of esophageal motility was developed to facilitate the interpretation of clinical high resolution esophageal pressure topography (EPT) studies, concurrent with the widespread adoption of this technology into clinical practice. The Chicago Classification has been an evolutionary process, molded first by published evidence pertinent to the clinical interpretation of high resolution manometry (HRM) studies and secondarily by group experience when suitable evidence is lacking.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This study investigated the variability of response associated with various perimetric techniques, with the aim of improving the clinical interpretation of automated static threshold perirnetry. Evaluation of a third generation of perimetric threshold algorithms (SITA) demonstrated a reduction in test duration by approximately 50% both in normal subjects and in glaucoma patients. SITA produced a slightly higher, but clinically insignificant, Mean Sensitivity than with the previous generations of algorithms. This was associated with a decreased between-subject variability in sensitivity and hence, lower confidence intervals for normality. In glaucoma, the SITA algorithms gave rise to more statistically significant visual field defects and a similar between-visit repeatability to the Full Threshold and FASTPAC algorithms. The higher estimated sensitivity observed with SITA compared to Full Threshold and FASTPAC were not attributed to a reduction in the fatigue effect. The investigation of a novel method of maintaining patient fixation, a roving fixation target which paused immediately prior lo the stimulus presentation, revealed a greater degree of fixational instability with the roving fixation target compared to the conventional static fixation target. Previous experience with traditional white-white perimetry did not eradicate the learning effect in short-wavelength automated perimetry (SWAP) in a group of ocular hypertensive patients. The learning effect was smaller in an experienced group of patients compared to a naive group of patients, but was still at a significant level to require that patients should undertake a series of at least three familiarisation tests with SWAP.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The diagnosis and monitoring of ocular disease presents considerable clinical difficulties for two main reasons i) the substantial physiological variation of anatomical structure of the visual pathway and ii) constraints due to technical limitations of diagnostic hardware. These are further confounded by difficulties in detecting early loss or change in visual function due to the masking of disease effects, for example, due to a high degree of redundancy in terms of nerve fibre number along the visual pathway. This thesis addresses these issues across three areas of study: 1. Factors influencing retinal thickness measures and their clinical interpretation As the retina is the principal anatomical site for damage associated with visual loss, objective measures of retinal thickness and retinal nerve fibre layer thickness are key to the detection of pathology. In this thesis the ability of optical coherence tomography (OCT) to provide repeatable and reproducible measures of retinal structure at the macula and optic nerve head is investigated. In addition, the normal physiological variations in retinal thickness and retinal nerve fibre layer thickness are explored. Principal findings were: • Macular retinal thickness and optic nerve head measurements are repeatable and reproducible for normal subjects and diseased eyes • Macular and retinal nerve fibre layer thickness around the optic nerve correlate negatively with axial length, suggesting that larger eyes have thinner retinae, potentially making them more susceptible to damage or disease • Foveola retinal thickness increases with age while retinal nerve fibre layer thickness around the optic nerve head decreases with age. Such findings should be considered during examination of the eye with suspect pathology or in long-term disease monitoring 2. Impact of glucose control on retinal anatomy and function in diabetes Diabetes is a major health concern in the UK and worldwide and diabetic retinopathy is a major cause of blindness in the working population. Objective, quantitative measurements of retinal thickness. particularly at the macula provide essential information regarding disease progression and the efficacy of treatment. Functional vision loss in diabetic patients is commonly observed in clinical and experimental studies and is thought to be affected by blood glucose levels. In the first study of its kind, the short term impact of fluctuations in blood glucose levels on retinal structure and function over a 12 hour period in patients with diabetes are investigated. Principal findings were: • Acute fluctuations in blood glucose levels are greater in diabetic patients than normal subjects • The fluctuations in blood glucose levels impact contrast sensitivity scores. SWAP visual fields, intraocular pressure and diastolic pressure. This effect is similar for type 1 and type 2 diabetic patients despite the differences in their physiological status. • Long-term metabolic control in the diabetic patient is a useful predictor in the fluctuation of contrast sensitivity scores. • Large fluctuations in blood glucose levels and/or visual function and structure may be indicative of an increased risk of development or progression of retinopathy 3. Structural and functional damage of the visual pathway in glaucomatous optic neuropathy The glaucomatous eye undergoes a number of well documented pathological changes including retinal nerve fibre loss and optic nerve head damage which is correlated with loss of functional vision. In experimental glaucoma there is evidence that glaucomatous damage extends from retinal ganglion cells in the eye, along the visual pathway, to vision centres in the brain. This thesis explores the effects of glaucoma on retinal nerve fibre layer thickness, ocular anterior anatomy and cortical structure, and its correlates with visual function in humans. Principal findings were: • In the retina, glaucomatous retinal nerve fibre layer loss is less marked with increasing distance from the optic nerve head, suggesting that RNFL examination at a greater distance than traditionally employed may provide invaluable early indicators of glaucomatous damage • Neuroretinal rim area and retrobulbar optic nerve diameter are strong indicators of visual field loss • Grey matter density decreases at a rate of 3.85% per decade. There was no clear evidence of a disease effect • Cortical activation as measured by fMRI was a strong indicator of functional damage in patients with significant neuroretinal rim loss despite relatively modest visual field defects These investigations have shown that the effects of senescence are evident in both the anterior and posterior visual pathway. A variety of anatomical and functional diagnostic protocols for the investigation of damage to the visual pathway in ocular disease are required to maximise understanding of the disease processes and thereby optimising patient care.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The availability of BRAF inhibitors has given metastatic melanoma patients an effective new treatment choice and molecular testing to determine the presence or absence of a BRAF codon 600 mutation is pivotal in the clinical management of these patients. This molecular test must be performed accurately and appropriately to ensure that the patient receives the most suitable treatment in a timely manner. Laboratories have introduced such testing; however, some experience low sample throughput making it critical that an external quality assurance programme is available to help promote a high standard of testing, reporting and provide an educational aspect for BRAF molecular testing. Laboratories took part in three rounds of external quality assessment (EQA) during a 12-month period giving participants a measure of the accuracy of genotyping, clinical interpretation of the result and experience in testing a range of different samples. Formalin fixed paraffin embedded tissue sections from malignant melanoma patients were distributed to participants for BRAF molecular testing. The standard of testing was generally high but distribution of a mutation other than the most common, p.(Val600Glu), highlighted concerns with detection or reporting of the presence of rarer mutations. The main issues raised in the interpretation of the results were the importance of clear unambiguous interpretation of the result tailored to the patient and the understanding that the treatment is different from that given to other stratified medicine programmes. The variability in reporting and wide range of methodologies used indicate a continuing need for EQA in this field.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Introdução – A cintigrafia de perfusão do miocárdio (CPM) é utilizada no diagnóstico e seguimento de pacientes com doença arterial coronária, sendo a sua avaliação frequentemente realizada através da análise visual dos cortes tomográficos. A escala de cores selecionada é essencial na interpretação clínica das imagens de perfusão do miocárdio. Objetivo – Avaliar a influência de diferentes escalas de cores na avaliação qualitativa das imagens de CPM e estudar quais as mais adequadas para análise visual. Métodos – Trinta e cinco estudos de CPM foram avaliados visualmente por 16 estudantes da licenciatura em medicina nuclear nas escalas de cores Cool, Gray, Gray Invert, Thermal e Warm. Para a escala de cores Cool, a análise das imagens de CPM foi realizada através de um sistema de classificação semiquantitativo por scores. As restantes escalas de cores foram avaliadas por comparação com a análise das imagens efetuada com escala de cores Cool. Resultados/Discussão – Para a escala de cores Cool, a variabilidade interoperador revelou a existência de diferenças estatisticamente significativas entre todos os participantes (p<0,05), o que se pode atribuir à subjetividade da avaliação visual. Os resultados relativos às escalas de cores Gray e Gray Invert foram os mais próximos da perfusão do miocárdio observada com a escala Cool, considerando-se escalas de cores alternativas na análise visual dos estudos de CPM. Para as escalas de cores Thermal e Warm os resultados foram mais divergentes, não se considerando adequadas para a avaliação visual dos estudos de CPM. Conclusão – A escala de cores influencia a avaliação qualitativa da perfusão na CPM.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Antecedente: La infección por el virus sincitial respiratorio (VSR) representa una elevada morbimortalidad, y en algunos casos necesidad de manejo en unidades de cuidado intensivo pediátrico (UCIP). La respuesta inmunológica influye de manera directa en la expresión de la severidad y pronóstico de los pacientes con infección respiratoria. Metodología: Estudio de una cohorte retrospectiva de pacientes con infección respiratoria grave secundaria a VSR, sin historia de inmunodeficiencia, atendidos en la UCIP del Hospital Universitario Clínica San Rafael. Se realizó análisis descriptivoglobaly de acuerdo a la categorización de las prueba de IgG. Resultados: De 188 pacientes que ingresaron a la UCIP, 13% presentaron infección por VSR (24), con una edad promedio de 7,3 (DE=3,6) meses. Pertenecían al sexo masculino79,83%. Se encontró que 12,5% tenían un valor de IgGbajo para su edad, 58,33% tenían valores en límite inferior y el 29,17% dentro de rangos normales para su edad. En los pacientes con IgG baja, fue mayor la presentación de choque séptico que no responde a líquidos (100 vs 92 vs 86%), la mediana de días de ventilación mecánica fue mayor (8 vs 6 vs 5 respectivamente), así como la mortalidad (67 vs 7,1 vs 0%). Conclusión: Nuestra serie encontró que aquellos pacientes con niveles bajos o valores en el límite inferior de IgG sérica tuvieron mayor compromiso sistémico, mayor duración de ventilación mecánica y mayor mortalidad. Se necesitan estudios prospectivos que relaciones niveles bajos de IgG con severidad y pronostico en estos pacientes con infección grave por VSR.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The introduction of the WHO FRAX® algorithms has facilitated the assessment of fracture risk on the basis of fracture probability. Its use in fracture risk prediction has strengths, but also limitations of which the clinician should be aware and are the focus of this review INTRODUCTION: The International Osteoporosis Foundation (IOF) and the International Society for Clinical Densitometry (ISCD) appointed a joint Task Force to develop resource documents in order to make recommendations on how to improve FRAX and better inform clinicians who use FRAX. The Task Force met in November 2010 for 3 days to discuss these topics which form the focus of this review. METHODS: This study reviews the resource documents and joint position statements of ISCD and IOF. RESULTS: Details on the clinical risk factors currently used in FRAX are provided, and the reasons for the exclusion of others are provided. Recommendations are made for the development of surrogate models where country-specific FRAX models are not available. CONCLUSIONS: The wish list of clinicians for the modulation of FRAX is large, but in many instances, these wishes cannot presently be fulfilled; however, an explanation and understanding of the reasons may be helpful in translating the information provided by FRAX into clinical practice.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The International Society for Clinical Densitometry (ISCD) and the International Osteoporosis Foundation (IOF) convened the FRAX(®) Position Development Conference (PDC) in Bucharest, Romania, on November 14, 2010, following a two-day joint meeting of the ISCD and IOF on the "Interpretation and Use of FRAX(®) in Clinical Practice." These three days of critical discussion and debate, led by a panel of international experts from the ISCD, IOF and dedicated task forces, have clarified a number of important issues pertaining to the interpretation and implementation of FRAX(®) in clinical practice. The Official Positions resulting from the PDC are intended to enhance the quality and clinical utility of fracture risk assessment worldwide. Since the field of skeletal assessment is still evolving rapidly, some clinically important issues addressed at the PDCs are not associated with robust medical evidence. Accordingly, some Official Positions are based largely on expert opinion. Despite limitations inherent in such a process, the ISCD and IOF believe it is important to provide clinicians and technologists with the best distillation of current knowledge in the discipline of bone densitometry and provide an important focus for the scientific community to consider. This report describes the methodology and results of the ISCD-IOF PDC dedicated to FRAX(®).