968 resultados para Chromatographic analysis.
Resumo:
The potential of solid phase microextraction (SPME) in the analysis of explosives is demonstrated. A sensitive, rapid, solventless and inexpensive method for the analysis of explosives and explosive odors from solid and liquid samples has been optimized using SPME followed by HPLC and GC/ECD. SPME involves the extraction of the organic components in debris samples into sorbent-coated silica fibers, which can be transferred directly to the injector of a gas chromatograph. SPME/HPLC requires a special desorption apparatus to elute the extracted analyte onto the column at high pressure. Results for use of GC/ECD is presented and compared to the results gathered by using HPLC analysis. The relative effects of controllable variables including fiber chemistry, adsorption and desorption temperature, extraction time, and desorption time have been optimized for various high explosives. ^
Resumo:
The potential of solid phase microextraction (SPME) in the analysis of explosives is demonstrated. A sensitive, rapid, solventless and inexpensive method for the analysis of explosives and explosive odors from solid and liquid samples has been optimized using SPME followed by HPLC and GC/ECD. SPME involves the extraction of the organic components in debris samples into sorbent-coated silica fibers, which can be transferred directly to the injector of a gas chromatograph. SPME/HPLC requires a special desorption apparatus to elute the extracted analyte onto the column at high pressure. Re suits for use of GC[ECD is presented and compared to the results gathered by using HPLC analysis. The relative effects of controllable variables including fiber chemistry, adsorption and desorption temperature, extraction time, and desorption time have been optimized for various high explosives.
Resumo:
Synthetic cannabinoid receptor agonists or more commonly known as synthetic cannabinoids (SCs) were originally created to obtain the medicinal value of THC but they are an emerging social problem. SCs are mostly produced coated on herbal materials or in powder form and marketed under a variety of brand names, e.g. “Spice”, “K2”. Despite many SCs becoming controlled under drug legislation, many of them remain legal in some countries around the world. In Scotland, SCs are controlled under the Misuse of Drugs Act 1971 and Psychoactive Substances Act 2016 that only cover a few early SCs. In Saudi Arabia, even fewer are controlled. The picture of the SCs-problem in Scotland is vague due to insufficient prevalence data, particularly that using biological samples. Whilst there is evidence of increasing use of SCs throughout the world, in Saudi Arabia, there is currently no data regarding the use of products containing SCs among Saudi people. Several studies indicate that SCs may cause serious toxicity and impairment to health therefore it is important to understand the scale of use within society. A simple and sensitive method was developed for the simultaneous analysis of 10 parent SCs (JWH-018, JWH-073, JWH-250, JWH-200, AM-1248, UR-144, A-796260, AB-FUBINACA, 5F-AKB-48 and 5F-PB-22) in whole blood and 8 corresponding metabolites (JWH-018 4-OH pentyl, JWH-073 3-OH butyl, JWH-250 4-OH pentyl, AM-2201 4-OH pentyl, JWH-122 5-OH pentyl, JWH-210 5-OH pentyl, 5F-AKB-48 (N-4 OH pentyl), 5F-PB-22 3-carboxyindole)in urine using LLE and LC-MS/MS. The method was validated according to the standard practices for method validation in forensic toxicology (SWGTOX, May 2013). All analytes gave acceptable precision, linearity and recovery for analysing blood and urine samples. The method was applied to 1,496 biological samples, a mixture of whole blood and urine. Blood and/or urine samples were analysed from 114 patients presenting at Accident and Emergency in Glasgow Royal Infirmary, in spring 2014 and JuneDecember 2015. 5F-AKB-48, 5F-PB-22 and MDMB-CHMICA were detected in 9, 7 and 9 cases respectively. 904 urine samples from individuals admitted to/liberated from Scottish prisons over November 2013 were tested for the presence of SCs. 5F-AKB-48 (N-4 OH pentyl) was detected in 10 cases and 5F-PB-22 3-carboxyindole in 3 cases. Blood and urine samples from two post-mortem cases in Scotland with suspected ingestion of SCs were analysed. Both cases were confirmed positive for 5F-AKB-48. A total of 463 urine samples were collected from personnel who presented to the Security Forces Hospital in Ryiadh for workplace drug testing as a requirement for their job during July 2014. The results of the analysis found 2 samples to be positive for 5F-PB-22 3carboxyindole. A further study in Saudi Arabia using a questionnaire was carried out among 3 subpopulations: medical professionals, members of the public in and around smoking cafes and known drug users. With regards to general awareness of Spice products, 16%, 11% and 22% of those participants of medical professionals, members of the public in and around smoking cafes and known drug users, respectively, were aware of the existence of SCs or Spice products. The respondents had an overall average of 4.5% who had a friend who used these Spice products. It is clear from the results obtained in both blood and urine testing and surveys that SCs are being used in both Scotland and Saudi Arabia. The extent of their use is not clear and the data presented here is an initial look into their prevalence. Blood and urine findings suggest changing trends in SC use, moving away from JWH and AM SCs to the newer 5F-AKB-48, 5-F-PB-22 and MDMBCHMICA compounds worldwide. In both countries 5F-PB-22 was detected. These findings clarify how the SCs phenomenon is a worldwide problem and how the information of every country regarding what SCs are seized can help and is not specific for that country. The analytes included in the method were selected due to their apparent availability in both countries, however it is possible that some newer analytes have been used and these would not have been detected. For this reason it is important that methods for testing SCs are updated regularly and evolve with the ever-changing availability of these drugs worldwide. In addition, there is little published literature regarding the concentrations of these drugs found in blood and urine samples and this work goes some way towards understanding these.
Resumo:
The antioxidant potential of mushrooms is mainly attributed to their composition in polysaccharides, phenolic compounds, tocopherols and some organic acids [1]. Phenolic compounds contribute directly to the antioxidative action and play an important role in stabilizing lipid peroxidation [2]; exhibit a wide range of bioactive properties such as anti-allergenic, anti-inflammatory and antimicrobial, which have been in part related to their antioxidant activity [3]. Tocopherols are important fatsoluble antioxidants, acting in the cellular membrane; due to their role as scavenger of free radicals protecting human cells against degenerative malfunctions [4]. Some organic acids are very common in natural matrices; malic acid contributes to a pleasantly sour taste and is often used as a food additive; citric acid is known due to its antibacterial and antioxidant properties and fumaric acid is important because of its antioxidant, anti-inflammatory, antimicrobial and acidifying properties [5]. The purpose of the present study was to analyze antioxidant and related compounds (phenolic compounds, tocopherols and organic acids) of Polyporus squamosus (Huds.) Fr. samples originated from two different origins (Portugal and Serbia). Specimens of P. squamosus were collected in Bragança (Northeast Portugal) and Jabučki rit (Northern Serbia) during April 2015 and 2012, respectively. Phenolic compounds, organic acids and tocopherols were determined by high performance liquid chromatograph (HPLC) coupled to a diode array detector (DAD), in the two first cases, and a fluorescence detector in the last one. With respect to phenolic and related compounds, p-hydroxybenzoic and cinnamic acids were identified in both samples; the first one predominates in the sample from Portugal, while cinnamic acid was more abundant in the sample from Serbia. Tocopherols (α-, β and γ-isoforms) were found in the sample from Serbia, but in the sample from Portugal, γ-tocopherol was not identified. This sample showed the highest total tocopherols content, and revealed the highest level of β-tocopherol; γ- tocopherol predominated in the sample from Serbia. Among organic acids, it was possible to quantify oxalic, malic and fumaric acids in both samples. Malic acid was found in higher amounts in the sample from Serbia. Overall, the present study shows that mushroom samples from different origins have dissimilar results, but are both rich in bioactive compounds, being a valuable source for the development of natural medicines and nutraceuticals.
Resumo:
Nowadays the rising cost of health care and pharmaceutical products, the increase in life expectancy as well as the demand for an improved quality of life, has led to an increased concern about food intake and an emergence of new concepts of nutrition [1]. Mushrooms have been pointed out as an excellent option to include in a healthy diet, due to their nutritional value [2] associated with their bioactive properties [3]. The current study presents the chemical profile of two edible species, Leccinum molle (Ban) Ban and Leccinum vulpinum Watling, harvested in the outskirts of Bragan9a (Northeastern Portugal), regarding their content in nutrients and nonnutrients. Individual profiles of sugars and fatty acids were obtained by HPLC-RI and GC-FID, respectively. Tocopherols were analysed by HPLC-fluorescence, and the non-nutrients (i.e., phenolic and other organic acids) by HPLC-PDA. The antioxidant activity of the methanolic extracts obtained from both species was assessed with different assays (e.g. reducing power, radical scavenging activity and lipid peroxidation inhibition) and their hepatotoxicity was evaluated in primary cell cultures obtained from porcine liver, PLP2. Generally, both Leccinum species revealed similar nutrient profiles, with low fat levels, fructose, mannitol and trehalose as the foremost free sugars, and higher percentages of mono- and polyunsaturated fatty acids in comparison with saturated fatty acids. The presence of bioactive compounds was also detected, namely phenolic (e.g., gallic, protocatechuic and p-hydroxybenzoic acids) and organic acids (e.g., citric and fumaric acids). Both species presented antioxidant properties, being L. vulpinum the species which showed the most promising results (higher contents of total phenolic acids and lower ECso values in all the performed assays). Neither of the extracts presented toxicity against the liver primary cells PLP2, up to maximal concentration tested (Giso > 400 μg/ml).
Resumo:
Ternary and binary gradient systems have been developed for the high-performance liquid chromatographic analysis of complex pigment distributions typical of natural samples. Improved chromatographic resolution reveals significantly more pigment components in extracts from a sediment (Priest Pot, Cumbria, UK), a microbial mat (les Salines de la Trinital, South Catalonia, Spain) and a culture (C. phaeobacteroides) including novel bacteriochlorophyll derivatives. The methods developed are directly suited to LC–MS analysis and the automated acquisition of MS/MS data for pigments.
Resumo:
"Copyright, 1941."
Resumo:
Polymethacrylate monoliths, specifically poly(glycidyl methacrylate-co-ethylene dimethacrylate) or poly(GMA-co-EDMA) monoliths, are a new generation of chromatographic supports and are significantly different from conventional particle-based adsorbents, membranes, and other monolithic supports for biomolecule purification. Similar to other monoliths, polymethacrylate monoliths possess large pores which allow convective flow of mobile phase and result in high flow rates at reduced pressure drop, unlike particulate supports. The simplicity of the adsorbent synthesis, pH resistance, and the ease and flexibility of tailoring their pore size to that of the target biomolecule are the key properties which differentiate polymethacrylate monoliths from other monoliths. Polymethacrylate monoliths are endowed with reactive epoxy groups for easy functionalization (with anion-exchange, hydrophobic, and affinity ligands) and high ligand retention. In this review, the structure and performance of polymethacrylate monoliths for chromatographic purification of biomolecules are evaluated and compared to those of other supports. The development and use of polymethacrylate monoliths for research applications have grown rapidly in recent times and have enabled the achievement of high through-put biomolecule purification on semi-preparative and preparative scales.
Resumo:
Organic acids are important constituents of fruit juices. They render tartness, flavour and specific taste to fruit juices. Shelf life and stability of fruit juices are important factors, which determine their nutritional quality and freshness. In this view, the effect of storage on the concentration of organic acids in commercially packed fruit juices is studied by reverse phase high performance liquid chromatography (RP-HPLC). Ten packed fruit juices from two different brands are stored at 30 C for 24, 48 and 72 hours. A reverse phase high performance liquid chromatographic method is used to determine the concentration of oxalic, tartaric, malic, ascorbic and citric acid in the fruit juices during storage. The chromatographic analysis of organic acids is carried out using mobile phase 0.5% (w/v) ammonium dihydrogen orthophosphate buffer (pH 2.8) on C18 column with UV-Vis detector. The results show that the concentration of organic acids generally decreases in juices under study with the increase in storage time. All the fruit juices belonging to tropicana brand underwent less organic acid degradation in comparison to juices of real brand. Orange fruit juice is found to be least stable among the juices under study, after the span of 72 hours. Amongst all the organic acids under investigation minimum stability is shown by ascorbic acid followed by malic and citric acid.
Resumo:
European Regulation 1169/2011 requires producers of foods that contain refined vegetable oils to label the oil types. A novel rapid and staged methodology has been developed for the first time to identify common oil species in oil blends. The qualitative method consists of a combination of a Fourier Transform Infrared (FTIR) spectroscopy to profile the oils and fatty acid chromatographic analysis to confirm the composition of the oils when required. Calibration models and specific classification criteria were developed and all data were fused into a simple decision-making system. The single lab validation of the method demonstrated the very good performance (96% correct classification, 100% specificity, 4% false positive rate). Only a small fraction of the samples needed to be confirmed with the majority of oils identified rapidly using only the spectroscopic procedure. The results demonstrate the huge potential of the methodology for a wide range of oil authenticity work.
Resumo:
The effects of sample solvent composition and the injection volume, on the chromatographic peak profiles of two carbamate derivatives, methyl 2-benzimidazolecarbamate (MBC) and 3-butyl-2,4-dioxo[1,2-a]-s-triazinobenzimidazole (STB), were studied using reverse phase high performance liquid chromatograph. The study examined the effects of acetonitrile percentage in the sample solvent from 5 to 50%, effects of methanol percentage from 5 to 50%, effects of pH increase from 4.42 to 9.10, and effect of increasing buffer concentration from ° to 0.12M. The effects were studied at constant and increasing injection mass and at four injection volumes of 10, 50, 100 and 200 uL. The study demonstrated that the amount and the type of the organic solvents, the pH, and the buffer strength of the sample solution can have a pronounced effect on the peak heights, peak widths, and retention times of compounds analysed. MBC, which is capable of intramolecular hydrogen bonding and has no tendency to ionize, showed a predictable increase .in band broadening and a decrease in retention times at higher eluting strengths of the sample solvent. STB, which has a tendency to ionize or to strongly interact with the sample solvent, was influenced in various ways by the changes in ths sample solvent composition. The sample solvent effects became more pronounced as the injection volume increased and as the percentage of organic solvent in the sample solution became greater. The peak height increases for STB at increasing buffer concentrations became much more pronounced at higher analyte concentrations. It was shown that the widely accepted procedure of dissolving samples in the mobile phase does not yield the most efficient chromatograms. For that reason samples should be dissolved in the solutions with higher aqueous content than that of the mobile phase whenever possible. The results strongly recommend that all the samples and standards, regardless whether the standards are external or internal, be analysed at a constant sample composition and a constant injection volume.
Resumo:
The incomplete combustion of biomass is one of the most important sources of emissions of organic compounds into the atmosphere, like polycyclic aromatic hydrocarbons (PAHs) which show genotoxic activity. Since environmental samples generally contain interferents and trace amounts of PAHs of interest, concentration and clean-up procedures are usually required prior to the final chromatographic analysis. This paper discusses the performance of Sep-Pak cartridges (silica gel and RP18) on clean-up of sugar cane soot extract. The best results were obtained with a silica Sep-Pak cartridge. The recoveries ranged from 79% (benzo[b]fluoranthene) to 113% (benzo[e]pyrene). (C) 2000 Elsevier B.V. B.V. All rights reserved.
Resumo:
Turnera diffusa Willd. var. afrodisiaca (Ward) Urb. (syn. T. aphrodisiaca) belongs to the family of Turneraceae and is an aromatic plant growing wild in the subtropical regions of America and Africa. It is widely used in the traditional medicine as e.g. anti-cough, diuretic, and aphrodisiac agent. This work presents a 3 min chromatographic analysis using low-pressure (LP) gas chromatography (GC)-ion-trap (IT) mass spectrometry (MS). The combination of a deactivated 0.6 m x 0.10 mm i.d., restrictor with a wide-bore CP-Wax 52 capillary column (10 m x 0.53 mm i.d., 1 mum) reduces the analysis time by a factor of 3-7 in comparison to the use of a conventional narrow bore column. Chromatographic conditions have been optimized to achieve the fastest separation with the highest signal/noise ratio in MS detection. These results allow fast and reliable quality control of the essential oil to be achieved. (C) 2003 Elsevier B.V. All rights reserved.
Resumo:
Hemoglobin variants originate mainly by simple amino acid substitutions, the result of nucleotide sequence changes. Recently, the number of known abnormal hemoglobins has increased due to improvement in analysis methodologies; however, many laboratories are not prepared to correctly identify mutants. Hb S is a very well-characterized hemoglobin variant that varies in prevalence in different regions of Brazil. However, there is a type of Hb that presents electrophoretic migration in alkaline pH similar to Hb S, named S-like Hb, which can be incorrectly diagnosed; therefore, its frequency is underestimated. We obtained reference ranges for Hb S by HPLC, and we examined the electrophoretic and chromatographic profiles of S-like Hb. Hb Hasharon, Hb D-Los Angeles, Hb Korle-Bu, Hb Lepore, Hb D-Iran, Hb G-like, Hb Queens, Hb Montgomery, and Hb Q-India were found. Cases of association between two beta chain mutants were also found. Electrophoresis in alkaline and acid pH was utilized to initially screen these Hb variants, and globin chain electrophoresis at both high and low pH was performed to identify the globin chain mutant. Chromatographic analysis permitted the identification of the hemoglobin variant and also facilitated the quantification of these variants. Therefore, an association of classical laboratory diagnostic methodologies is fundamental for the correct identification of suspect Hb variants. The S and S-like hemoglobin profiles determined in this study will help in the diagnosis of these variants in health care services.