272 resultados para Chlorinated ethylenes


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A data manipulation method has been developed for automatic peak recognition and result evaluation in the analysis of organic chlorinated hydrocarbons with dual-column gas chromatography. Based on the retention times of two internal standards, pentachlorotoluene and decachlorobiphenyl, the retention times of chlorinated hydrocarbons can be calibrated automatically and accurately. It is very convenient to identify the peaks by comparing the retention times of samples with the calibrated retention times calculated from the relative retention indices of standards. Meanwhile, with a suggested two-step evaluation method the evaluation coefficients and the suitable quantitative results of each component can be automatically achieved for practical samples in an analytical system using two columns with different polarities and two internal standards. (C) 2002 Elsevier Science B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this research was to determine polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/F) in five chlorinated chemicals (phthalocyanine copper, phthalocyanine green, chloranil-1 and 2, and triclosan), and to compare their 2,3,7,8-tetrachlordibenzo-IpI-dioxin equivalents (TEQ). The distribution patterns of total PCDD/Fs and 2,3,7,8-substituted PCDD/Fs were elucidated in detail. The TEQ values of toxic PCDD/Fs in all chemicals were in the range of 5.03-1379.55 ng I-TEQ/kg. The contribution of OCDD and OCDF in phthalocyanine green was 75% of the total TEQ. For chloranils, the maximum contribution of toxic PCDD/Fs was from 2,3,7,8-substituted HxCDF and 2,3,7,8-substituted HpCDF. The TEQ of HxCDF and HpCDF in chloranil-1 was 90% and in chloranil-2 was 71%. And the toxic contribution increased with the degree of chlorination for PCDFs. (C) 2005 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Chlorinated hydrocarbon pesticides are now present in low concentration in most waters. While generally not causing direct mortality so far as we know, they may well have sub-lethal effects, reducing the health and viability of marine organisms. In this study the effect of Endosulfan, DDT and dieldrin on respiration, heart beat and burrowing of some marine bivalves has been examined.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The southern industrial rivers (Aire, Calder, Don and Trent) feeding the Humber estuary were routinely monitored for a range of chlorinated micro- organic contaminants at least once a week over a 1.5-year period. Environmental Quality Standards (EQSs) for inland waters were set under the European Economic Community for a limited number of problematic contaminants (18). The results of the monitoring program for seven classes of chlorinated pollutants on the EQS list are presented in this study. All compounds were detected frequently with the exception of hexachlorobutadiene (where only one detectable measurement out of 280 individual samples occurred). In general, the rivers fell into two classes with respect to their contamination patterns. The Aire and Calder carried higher concentrations of micro- pollutants than the Don and Trent, with the exception of hexachlorobenzene (HCB). For Σ hexachlorocyclohexane (HCH) isomers (α + γ) and for dieldrin, a number of samples (~ 5%) exceeded their EQS for both the Aire and Calder. Often, ΣHCH concentrations were just below the EQS level. Levels of p,p'- DDT on occasions approached the EQS for these two rivers, but only one sample (out of 140) exceeded the EQS. No compounds exceeded their EQS levels on the Don and Trent. Analysis of the ratio of γ HCH/αHCH indicated that the source of HCH for the Don and Trent catchments was primarily lindane (γHCH) and, to a lesser extent, technical HCH (mixture of HCH isomers, dominated by α HCH), while the source(s) for the Aire and Calder had a much higher contribution from technical HCH.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new procedure for determining eleven organochlorine pesticides in soils using microwave-assisted extraction (MAE) and headspace solid phase microextraction (HS-SPME) is described. The studied pesticides consisted of mirex, α- and γ-chlordane, p,p’-DDT, heptachlor, heptachlor epoxide isomer A, γ-hexachlorocyclohexane, dieldrin, endrin, aldrine and hexachlorobenzene. The HS-SPME was optimized for the most important parameters such as extraction time, sample volume and temperature. The present analytical procedure requires a reduced volume of organic solvents and avoids the need for extract clean-up steps. For optimized conditions the limits of detection for the method ranged from 0.02 to 3.6 ng/g, intermediate precision ranged from 14 to 36% (as CV%), and the recovery from 8 up to 51%. The proposed methodology can be used in the rapid screening of soil for the presence of the selected pesticides, and was applied to landfill soil samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

ABSTRACT: p-Phenylenediamine was chemically attached to low molecular weight chlorinated paraffin wax. The polymer-bound p-phenylenediamine was characterized by vapor-phase osmometry (VPO), proton magnetic resonance spectroscopy ('H-NMR), infrared spectroscopy (IR), and thermogravimetric analysis (TGA). The efficiency and permanence of the polymer-bound p-phenylenediamine as an antioxidant was compared with a conventional amine-type antioxidant in natural rubber vulcanizates. The vulcanizates showed improved aging resistance in comparison to vulcanizates containing a conventional antioxidant. The presence of liquid polymer-bound p-phenylenediamine also reduces the amount of the plasticizer required for compounding.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Stable isotopic characterization of chlorine in chlorinated aliphatic pollution is potentially very valuable for risk assessment and monitoring remediation or natural attenuation. The approach has been underused because of the complexity of analysis and the time it takes. We have developed a new method that eliminates sample preparation. Gas chromatography produces individually eluted sample peaks for analysis. The He carrier gas is mixed with Ar and introduced directly into the torch of a multicollector ICPMS. The MC-ICPMS is run at a high mass resolution of >= 10 000 to eliminate interference of mass 37 ArH with Cl. The standardization approach is similar to that for continuous flow stable isotope analysis in which sample and reference materials are measured successively. We have measured PCE relative to a laboratory TCE standard mixed with the sample. Solvent samples of 200 nmol to 1.3 mu mol ( 24- 165 mu g of Cl) were measured. The PCE gave the same value relative to the TCE as measured by the conventional method with a precision of 0.12% ( 2 x standard error) but poorer precision for the smaller samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The separation by solvent extraction of Am-241(III) from Eu-152(III), in 1 M NaNO3 weakly acidic (pH 4) aqueous solutions, into dilute (ca. 10(-2) M) solutions of triazinylbipyridine derivatives (diethylhemi-BTP or di(benzyloxyphenyl) hemi-BTP) and chlorinated cobalt dicarbollide (COSAN) in 1-octanol or nitrobenzene has been studied. The N-tridentate heterocyclic ligands, which are selective for Am(III) over Eu(III), secured efficient separation of the two metal ions, while COSAN, strongly hydrophobic and fully dissociated in polar diluents, enhanced the extraction of the metal ions by ion-pair formation. Molecular interactions between the two co-extractants, observed at higher concentrations, led to the precipitation of their 1: 1 molecular adduct. In spite of that, efficient separations of Am and Eu ions were attained, with high separation factors, SFAm/Eu of 40 and even 60, provided the concentration of hemi-BTP was significantly greater than that of COSAN. Excess COSAN concentrations caused an antagonistic effect, decreasing both the distribution ratio of the metal ions and their separation factor.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Amorphous hydrogenated chlorinated carbon (a-C:H:Cl) films were produced by the plasma polymerization of chloroform-acetylene-argon mixtures in a radiofrequency plasma enhanced chemical vapor deposition system. The main parameter of interest was the proportion of chloroform in the feed, R(C), which was varied from 0 to 80%. Deposition rates of 80 nm min (1) were typical for the chlorinated films. Infrared reflection-absorption spectroscopy revealed the presence of C-Cl groups in all the films produced with chloroform in the feed. X-ray photoelectron spectroscopy confirmed this finding, and revealed a saturation of the chlorine content at similar to 47 at.% for R(C)>= 40%. The refractive index and optical gap, E(04), of the films were roughly in the 1.6 to 1.7, and the 2.8 to 3.7 eV range. These values were calculated from transmission ultraviolet-visible-near infrared spectra. Chlorination leads to an increase in the water surface contact angle from similar to 40 degrees to similar to 77 degrees. (C) 2011 Elsevier B.V. All rights reserved.