873 resultados para Cervical manipulation
Resumo:
This research examined for the first time the relationship between emotional manipulation, emotional intelligence, and primary and secondary psychopathy. As predicted, in Study 1 (N = 73), emotional manipulation was related to both primary and secondary psychopathy. Only secondary psychopathy was related to perceived poor emotional skills. Secondary psychopathy was also related to emotional concealment. Emotional intelligence was negatively related to perceived poor emotional skills, emotional concealment, and primary and secondary psychopathy. In Study 2 (N = 275), two additional variables were included: alexithymia and ethical position. It was found that for males, primary psychopathy and emotional intelligence predicted emotional manipulation, while for females emotional intelligence acted as a suppressor, and ethical idealism and secondary psychopathy were additional predictors. For males, emotional intelligence and alexithymia were related to perceived poor emotional skills, while for females emotional intelligence, but not alexithymia, predicted perceived poor emotional skills, with ethical idealism acting as a suppressor. For both males and females, alexithymia predicted emotional concealment. These findings suggest that the mechanisms behind the emotional manipulation–psychopathy relationship differ as a function of gender. Examining the different aspects of emotional manipulation as separate but related constructs may enhance understanding of the construct of emotional manipulation.
Resumo:
Aims: To develop clinical protocols for acquiring PET images, performing CT-PET registration and tumour volume definition based on the PET image data, for radiotherapy for lung cancer patients and then to test these protocols with respect to levels of accuracy and reproducibility. Method: A phantom-based quality assurance study of the processes associated with using registered CT and PET scans for tumour volume definition was conducted to: (1) investigate image acquisition and manipulation techniques for registering and contouring CT and PET images in a radiotherapy treatment planning system, and (2) determine technology-based errors in the registration and contouring processes. The outcomes of the phantom image based quality assurance study were used to determine clinical protocols. Protocols were developed for (1) acquiring patient PET image data for incorporation into the 3DCRT process, particularly for ensuring that the patient is positioned in their treatment position; (2) CT-PET image registration techniques and (3) GTV definition using the PET image data. The developed clinical protocols were tested using retrospective clinical trials to assess levels of inter-user variability which may be attributed to the use of these protocols. A Siemens Somatom Open Sensation 20 slice CT scanner and a Philips Allegro stand-alone PET scanner were used to acquire the images for this research. The Philips Pinnacle3 treatment planning system was used to perform the image registration and contouring of the CT and PET images. Results: Both the attenuation-corrected and transmission images obtained from standard whole-body PET staging clinical scanning protocols were acquired and imported into the treatment planning system for the phantom-based quality assurance study. Protocols for manipulating the PET images in the treatment planning system, particularly for quantifying uptake in volumes of interest and window levels for accurate geometric visualisation were determined. The automatic registration algorithms were found to have sub-voxel levels of accuracy, with transmission scan-based CT-PET registration more accurate than emission scan-based registration of the phantom images. Respiration induced image artifacts were not found to influence registration accuracy while inadequate pre-registration over-lap of the CT and PET images was found to result in large registration errors. A threshold value based on a percentage of the maximum uptake within a volume of interest was found to accurately contour the different features of the phantom despite the lower spatial resolution of the PET images. Appropriate selection of the threshold value is dependant on target-to-background ratios and the presence of respiratory motion. The results from the phantom-based study were used to design, implement and test clinical CT-PET fusion protocols. The patient PET image acquisition protocols enabled patients to be successfully identified and positioned in their radiotherapy treatment position during the acquisition of their whole-body PET staging scan. While automatic registration techniques were found to reduce inter-user variation compared to manual techniques, there was no significant difference in the registration outcomes for transmission or emission scan-based registration of the patient images, using the protocol. Tumour volumes contoured on registered patient CT-PET images using the tested threshold values and viewing windows determined from the phantom study, demonstrated less inter-user variation for the primary tumour volume contours than those contoured using only the patient’s planning CT scans. Conclusions: The developed clinical protocols allow a patient’s whole-body PET staging scan to be incorporated, manipulated and quantified in the treatment planning process to improve the accuracy of gross tumour volume localisation in 3D conformal radiotherapy for lung cancer. Image registration protocols which factor in potential software-based errors combined with adequate user training are recommended to increase the accuracy and reproducibility of registration outcomes. A semi-automated adaptive threshold contouring technique incorporating a PET windowing protocol, accurately defines the geometric edge of a tumour volume using PET image data from a stand alone PET scanner, including 4D target volumes.
Resumo:
Serotonergic hypofunction is associated with a depressive mood state, an increased drive to eat and preference for sweet (SW) foods. High-trait anxiety individuals are characterised by a functional shortage of serotonin during stress, which in turn increases their susceptibility to experience a negative mood and an increased drive for SW foods. The present study examined whether an acute dietary manipulation, intended to increase circulating serotonin levels, alleviated the detrimental effects of a stress-inducing task on subjective appetite and mood sensations, and preference for SW foods in high-trait anxiety individuals. Thirteen high- (eleven females and two males; anxiety scores 45·5 (sd 5·9); BMI 22·9 (sd 3·0)kg/m2) and twelve low- (ten females and two males; anxiety scores 30·4 (sd 4·8); BMI 23·4 (sd 2·5) kg/m2) trait anxiety individuals participated in a placebo-controlled, two-way crossover design. Participants were provided with 40 g α-lactalbumin (LAC; l-tryptophan (Trp):large neutral amino acids (LNAA) ratio of 7·6) and 40 g casein (placebo) (Trp:LNAA ratio of 4·0) in the form of a snack and lunch on two test days. On both the test days, participants completed a stress-inducing task 2 h after the lunch. Mood and appetite were assessed using visual analogue scales. Changes in food hedonics for different taste and nutrient combinations were assessed using a computer task. The results demonstrated that the LAC manipulation did not exert any immediate effects on mood or appetite. However, LAC did have an effect on food hedonics in individuals with high-trait anxiety after acute stress. These individuals expressed a lower liking (P = 0·012) and SW food preference (P = 0·014) after the stressful task when supplemented with LAC.
Resumo:
The Australian e-Health Research Centre in collaboration with the Queensland University of Technology's Paediatric Spine Research Group is developing software for visualisation and manipulation of large three-dimensional (3D) medical image data sets. The software allows the extraction of anatomical data from individual patients for use in preoperative planning. State-of-the-art computer technology makes it possible to slice through the image dataset at any angle, or manipulate 3D representations of the data instantly. Although the software was initially developed to support planning for scoliosis surgery, it can be applied to any dataset whether obtained from computed tomography, magnetic resonance imaging or any other imaging modality.
Resumo:
...the probabilistic computer simulation study by Dunham and colleagues evaluating the impact of different cervical spine management (CSM) strategies on tetraplegia and brain injury outcomes.1 Based on literature findings, expert opinion and with use of advances programming techniques the authors conclude that early collar removal without cervical spine magnetic resonance imaging (MRI) is a preferable CSM strategy for comatose, blunt trauma patients with extremity movement and a negative cervical spine computed tomography(CT) scan. Although we do not have the required expertise to comment on the applied statistical approach, we would like to comment on one of the medical assumptions raised by the authors, namely the likelihood of tetraplegia in this specific population....