897 resultados para Cardiac valves
Resumo:
Trabalho Final do Curso de Mestrado Integrado em Medicina, Faculdade de Medicina, Universidade de Lisboa, 2014
Resumo:
Background: Aortic valve replacement with a cryopreserved aortic homograft (CH) is an attractive alternative to bioprosthesis implantation. The aim of the study was to compare the hemodynamic performance of CH implanted with aortic root inclusion compared to prototype stentless (SS) bioprosthesis, standard stented (SD) bioprosthesis, and a native aortic valve. Methods: Hemodynamics and Doppler echocardiographic measurements such as left ventricular ejection fraction, aortic valve orifice area index (AVOAI), mean and maximal transvalvular gradients, were obtained at rest and immediately after exercise in 28 patients after aortic valve replacement with CH (n = 10), SS (n = 9), or SD (n = 9), and in a control group (CG) of 15 normal volunteers. Results: Rest and peak exercise heart rate and workload achieved were not different among the groups. Baseline AVOAI was larger for CH and CG compared to SS and SD groups (P < 0.05). Maximal and mean transvalvular pressure gradients at rest were lower for CH compared to SS and SD groups (P < 0.05), but higher than CG (P < 0,05). Conclusion: Implanted aortic CH had better hemodynamic performance than SS and SD bioprosthesis and similar to native normal aortic valves, both at rest and immediately after exercise. (ECHOCARDIOGRAPHY, Volume 26, November 2009).
Resumo:
Infective endocarditis (IE) is now rare in developed countries, but its prevalence is higher in elderly patients with prosthetic valves, diabetes, renal impairment, or heart failure. An increase in health-care associated IE (HCAIE) has been observed due to invasive maneuvers (30% of cases). Methicillin-resistant Staphylococcus aureus (MRSA) and Enterococcus are the most common agents in HCAIE, causing high mortality and morbidity. We review complications of IE and its therapy, based on a patient with acute bivalvular left-sided MRSA IE and a prosthetic aortic valve, aggravated by congestive heart failure, stroke, acute immune complex glomerulonephritis, Candida parapsilosis fungémia and death probably due to Serratia marcescens sepsis. The HCAIE was assumed to be related to three temporally associated in-hospital interventions considered as possible initial etiological mechanisms: overcrowding in the hospital environment,iv quinolone therapy and red blood cell transfusion. Later in the clinical course,C. parapsilosis and S. marcescens septicemia were considered to be possible secondary etiological mechanisms of HCAIE.
Resumo:
BACKGROUND: To date, there is no quality assurance program that correlates patient outcome to perfusion service provided during cardiopulmonary bypass (CPB). A score was devised, incorporating objective parameters that would reflect the likelihood to influence patient outcome. The purpose was to create a new method for evaluating the quality of care the perfusionist provides during CPB procedures and to deduce whether it predicts patient morbidity and mortality. METHODS: We analysed 295 consecutive elective patients. We chose 10 parameters: fluid balance, blood transfused, Hct, ACT, PaO2, PaCO2, pH, BE, potassium and CPB time. Distribution analysis was performed using the Shapiro-Wilcoxon test. This made up the PerfSCORE and we tried to find a correlation to mortality rate, patient stay in the ICU and length of mechanical ventilation. Univariate analysis (UA) using linear regression was established for each parameter. Statistical significance was established when p < 0.05. Multivariate analysis (MA) was performed with the same parameters. RESULTS: The mean age was 63.8 +/- 12.6 years with 70% males. There were 180 CABG, 88 valves, and 27 combined CABG/valve procedures. The PerfSCORE of 6.6 +/- 2.4 (0-20), mortality of 2.7% (8/295), CPB time 100 +/- 41 min (19-313), ICU stay 52 +/- 62 hrs (7-564) and mechanical ventilation of 10.5 +/- 14.8 hrs (0-564) was calculated. CPB time, fluid balance, PaO2, PerfSCORE and blood transfused were significantly correlated to mortality (UA, p < 0.05). Also, CPB time, blood transfused and PaO2 were parameters predicting mortality (MA, p < 0.01). Only pH was significantly correlated for predicting ICU stay (UA). Ultrafiltration (UF) and CPB time were significantly correlated (UA, p < 0.01) while UF (p < 0.05) was the only parameter predicting mechanical ventilation duration (MA). CONCLUSIONS: CPB time, blood transfused and PaO2 are independent risk factors of mortality. Fluid balance, blood transfusion, PaO2, PerfSCORE and CPB time are independent parameters for predicting morbidity. PerfSCORE is a quality of perfusion measure that objectively quantifies perfusion performance.
Resumo:
Intraoperative cardiac imaging plays a key role during transcatheter aortic valve replacement. In recent years, new techniques and new tools for improved image quality and virtual navigation have been proposed, in order to simplify and standardize stent valve positioning and implantation. But routine performance of the new techniques may require major economic investments or specific knowledge and skills and, for this reason, they may not be accessible to the majority of cardiac centres involved in transcatheter valve replacement projects. Additionally, they still require injections of contrast medium to obtain computed images. Therefore, we have developed and describe here a very simple and intuitive method of positioning balloon-expandable stent valves, which represents the evolution of the 'dumbbell' technique for echocardiography-guided transcatheter valve replacement without angiography. This method, based on the partial inflation of the balloon catheter during positioning, traps the crimped valve in the aortic valve orifice and, consequently, very near to the ideal landing zone. It does not require specific echocardiographic knowledge; it does not require angiographies that increase the risk of postoperative kidney failure in elderly patients, and it can be also performed in centres not equipped with a hybrid operating room.
Resumo:
Background: CMR has recently emerged as a robust and reliable technique to assess coronary artery disease (CAD). A negative perfusion CMR test predicts low event rates of 0.3-0.5%/year. Invasive coronary angiography (CA) remains the "gold standard" for the evaluation of CAD in many countries.Objective: Assessing the costs of the two strategies in the European CMR registry for the work-up of known or suspected CAD from a health care payer perspective. Strategy 1) a CA to all patients or 2) a CA only to patients who are diagnosed positive for ischemia in a prior CMR.Method and results: Using data of the European CMR registry (20 hospitals, 11'040 consecutive patients) we calculated the proportion of patients who were diagnosed positive (20.6%), uncertain (6.5%), and negative (72.9%) after the CMR test in patients with known or suspected CAD (n=2'717). No other medical test was performed to patients who were negative for ischemia. Positive diagnosed patients had a coronary angiography. Those with uncertain diagnosis had additional tests (84.7%: stress echocardiography, 13.1%: CCT, 2.3% SPECT), these costs were added to the CMR strategy costs. Information from costs for tests in Germany and Switzerland were used. A sensibility analysis was performed for inpatient CA. For costs see figure. Results - costs.Discussion: The CMR strategy costs less than the CA strategy for the health insurance systems both, in Germany and Switzerland. While lower in costs, the CMR strategy is a non-invasive one, does not expose to radiation, and yields additional information on cardiac function, viability, valves, and great vessels. Developing the use of CMR instead of CA might imply some reduction in costs together with superior patient safety and comfort, and a better utilization of resources at the hospital level. Document introduit le : 01.12.2011
Resumo:
Prenatal heart valve interventions aiming at the early and systematic correction of congenital cardiac malformations represent a promising treatment option in maternal-fetal care. However, definite fetal valve replacements require growing implants adaptive to fetal and postnatal development. The presented study investigates the fetal implantation of prenatally engineered living autologous cell-based heart valves. Autologous amniotic fluid cells (AFCs) were isolated from pregnant sheep between 122 and 128 days of gestation via transuterine sonographic sampling. Stented trileaflet heart valves were fabricated from biodegradable PGA-P4HB composite matrices (n = 9) and seeded with AFCs in vitro. Within the same intervention, tissue engineered heart valves (TEHVs) and unseeded controls were implanted orthotopically into the pulmonary position using an in-utero closed-heart hybrid approach. The transapical valve deployments were successful in all animals with acute survival of 77.8% of fetuses. TEHV in-vivo functionality was assessed using echocardiography as well as angiography. Fetuses were harvested up to 1 week after implantation representing a birth-relevant gestational age. TEHVs showed in vivo functionality with intact valvular integrity and absence of thrombus formation. The presented approach may serve as an experimental basis for future human prenatal cardiac interventions using fully biodegradable autologous cell-based living materials.
Resumo:
Recent advances in CT technologies had significantly improved the clinical utility of cardiac CT. Major efforts have been made to optimize the image quality, standardize protocols and limit the radiation exposure. Rapid progress in post-processing tools dedicated not only to the coronary artery assessment but also to the cardiac cavities, valves and veins extended applications of cardiac CT. This potential might be however used optimally considering the current appropriate indications for use as well as the current technical imitations. Coronary artery disease and related ischemic cardiomyopathy remain the major applications of cardiac CT and at the same time the most complex one. Integration of a specific knowledge is mandatory for optimal use in this area for asymptomatic as for symptomatic patients, with a specific regards to patient with acute chest pain. This review aimed to propose a practical approach to implement appropriate indications in our routine practice. Emerging indications and future direction are also discussed. Adequate preparation of the patient, training of physicians, and the multidisciplinary interaction between actors are the key of successful implementation of cardiac CT in daily practice.
Resumo:
BACKGROUND Transcatheter aortic valve-in-valve implantation is an emerging therapeutic alternative for patients with a failed surgical bioprosthesis and may obviate the need for reoperation. We evaluated the clinical results of this technique using a large, worldwide registry. METHODS AND RESULTS The Global Valve-in-Valve Registry included 202 patients with degenerated bioprosthetic valves (aged 77.7±10.4 years; 52.5% men) from 38 cardiac centers. Bioprosthesis mode of failure was stenosis (n=85; 42%), regurgitation (n=68; 34%), or combined stenosis and regurgitation (n=49; 24%). Implanted devices included CoreValve (n=124) and Edwards SAPIEN (n=78). Procedural success was achieved in 93.1% of cases. Adverse procedural outcomes included initial device malposition in 15.3% of cases and ostial coronary obstruction in 3.5%. After the procedure, valve maximum/mean gradients were 28.4±14.1/15.9±8.6 mm Hg, and 95% of patients had ≤+1 degree of aortic regurgitation. At 30-day follow-up, all-cause mortality was 8.4%, and 84.1% of patients were at New York Heart Association functional class I/II. One-year follow-up was obtained in 87 patients, with 85.8% survival of treated patients. CONCLUSIONS The valve-in-valve procedure is clinically effective in the vast majority of patients with degenerated bioprosthetic valves. Safety and efficacy concerns include device malposition, ostial coronary obstruction, and high gradients after the procedure.
Resumo:
A 49-year-old woman, without known cardiovascular risk factors. Hoarseness of voice caused by a paralysis of left vocal cord. She was admitted to hospital because of acute coronary syndrome, associated to resuscitated cardiac arrest (asystolia documented) without later neurology sequels. Physical examination was anodyne. Echocardiographic study demonstrated a compatible image with a large left sinus of Valsalva aneurysm (SVA) (Panel A) and mild aortic regurgitation. Cardiac catheterization confirmed the presence of left SVA (Panel B) that produced extrinsic compression of the left main coronary artery (Panels C and D). Repair surgery was made by means of closing the aneurysmal orifice with a patch of dacron. Intra-operatory echocardiographic control study found severe aortic regurgitation, so valvular replacement with 19 mm mechanical prosthesis and extension of the valve annulus with patch of dacron was performed, associated with bypass with safena vein graft to left coronary artery. SVA is a very infrequent cardiac anomaly, generally with silent clinical course until it ruptures. Myocardial ischaemia caused by coronary artery compression is unusual. We described the case of a patient diagnosed of left SVA, whose initial clinical manifestation was the appearance of resuscitated sudden cardiac death in the context of an acute coronary syndrome.
Resumo:
IMPORTANCE: Owing to a considerable shift toward bioprosthesis implantation rather than mechanical valves, it is expected that patients will increasingly present with degenerated bioprostheses in the next few years. Transcatheter aortic valve-in-valve implantation is a less invasive approach for patients with structural valve deterioration; however, a comprehensive evaluation of survival after the procedure has not yet been performed. OBJECTIVE: To determine the survival of patients after transcatheter valve-in-valve implantation inside failed surgical bioprosthetic valves. DESIGN, SETTING, AND PARTICIPANTS: Correlates for survival were evaluated using a multinational valve-in-valve registry that included 459 patients with degenerated bioprosthetic valves undergoing valve-in-valve implantation between 2007 and May 2013 in 55 centers (mean age, 77.6 [SD, 9.8] years; 56% men; median Society of Thoracic Surgeons mortality prediction score, 9.8% [interquartile range, 7.7%-16%]). Surgical valves were classified as small (≤21 mm; 29.7%), intermediate (>21 and <25 mm; 39.3%), and large (≥25 mm; 31%). Implanted devices included both balloon- and self-expandable valves. MAIN OUTCOMES AND MEASURES: Survival, stroke, and New York Heart Association functional class. RESULTS: Modes of bioprosthesis failure were stenosis (n = 181 [39.4%]), regurgitation (n = 139 [30.3%]), and combined (n = 139 [30.3%]). The stenosis group had a higher percentage of small valves (37% vs 20.9% and 26.6% in the regurgitation and combined groups, respectively; P = .005). Within 1 month following valve-in-valve implantation, 35 (7.6%) patients died, 8 (1.7%) had major stroke, and 313 (92.6%) of surviving patients had good functional status (New York Heart Association class I/II). The overall 1-year Kaplan-Meier survival rate was 83.2% (95% CI, 80.8%-84.7%; 62 death events; 228 survivors). Patients in the stenosis group had worse 1-year survival (76.6%; 95% CI, 68.9%-83.1%; 34 deaths; 86 survivors) in comparison with the regurgitation group (91.2%; 95% CI, 85.7%-96.7%; 10 deaths; 76 survivors) and the combined group (83.9%; 95% CI, 76.8%-91%; 18 deaths; 66 survivors) (P = .01). Similarly, patients with small valves had worse 1-year survival (74.8% [95% CI, 66.2%-83.4%]; 27 deaths; 57 survivors) vs with intermediate-sized valves (81.8%; 95% CI, 75.3%-88.3%; 26 deaths; 92 survivors) and with large valves (93.3%; 95% CI, 85.7%-96.7%; 7 deaths; 73 survivors) (P = .001). Factors associated with mortality within 1 year included having small surgical bioprosthesis (≤21 mm; hazard ratio, 2.04; 95% CI, 1.14-3.67; P = .02) and baseline stenosis (vs regurgitation; hazard ratio, 3.07; 95% CI, 1.33-7.08; P = .008). CONCLUSIONS AND RELEVANCE: In this registry of patients who underwent transcatheter valve-in-valve implantation for degenerated bioprosthetic aortic valves, overall 1-year survival was 83.2%. Survival was lower among patients with small bioprostheses and those with predominant surgical valve stenosis.
Resumo:
BACKGROUND: Transcatheter aortic valve-in-valve implantation is an emerging therapeutic alternative for patients with a failed surgical bioprosthesis and may obviate the need for reoperation. We evaluated the clinical results of this technique using a large, worldwide registry. METHODS AND RESULTS: The Global Valve-in-Valve Registry included 202 patients with degenerated bioprosthetic valves (aged 77.7±10.4 years; 52.5% men) from 38 cardiac centers. Bioprosthesis mode of failure was stenosis (n=85; 42%), regurgitation (n=68; 34%), or combined stenosis and regurgitation (n=49; 24%). Implanted devices included CoreValve (n=124) and Edwards SAPIEN (n=78). Procedural success was achieved in 93.1% of cases. Adverse procedural outcomes included initial device malposition in 15.3% of cases and ostial coronary obstruction in 3.5%. After the procedure, valve maximum/mean gradients were 28.4±14.1/15.9±8.6 mm Hg, and 95% of patients had ≤+1 degree of aortic regurgitation. At 30-day follow-up, all-cause mortality was 8.4%, and 84.1% of patients were at New York Heart Association functional class I/II. One-year follow-up was obtained in 87 patients, with 85.8% survival of treated patients. CONCLUSIONS: The valve-in-valve procedure is clinically effective in the vast majority of patients with degenerated bioprosthetic valves. Safety and efficacy concerns include device malposition, ostial coronary obstruction, and high gradients after the procedure.
Resumo:
ObjectiveTo compare cardiac output (CO) measured by Doppler echocardiography and thermodilution techniques in spontaneously breathing dogs during continuous infusion of propofol. To do so, CO was obtained using the thermodilution method (CO(TD)) and Doppler evaluation of pulmonary flow (CO(DP)) and aortic flow (CO(DA)).Study designProspective cohort study.AnimalsEight adult dogs weighing 8.3 +/- 2.0 kg.MethodsPropofol was used for induction (7.5 +/- 1.9 mg kg-1 IV) followed by a continuous rate infusion at 0.7 mg kg-1 minute-1. The animals were positioned in left lateral recumbency on an echocardiography table that allowed for positioning of the transducer at the 3rd and 5th intercostal spaces of the left hemithorax for Doppler evaluation of pulmonary and aortic valves, respectively. CO(DP) and CO(DA) were calculated from pulmonary and aortic velocity spectra, respectively. A pulmonary artery catheter was inserted via the jugular vein and positioned inside the lumen of the pulmonary artery in order to evaluate CO(TD). The first measurement of CO(TD), CO(DP) and CO(DA) was performed 30 minutes after beginning continuous infusion (T0) and then at 15-minute intervals (T15, T30, T45 and T60). Numeric data were submitted to two-way anova for repeated measurements, Pearson's correlation coefficient and Bland & Altman analysis. Data are presented as mean +/- SD.ResultsAt T0, CO(TD) was lower than CO(DA). CO(DA) was higher than CO(TD) and CO(DP) at T30, T45 and T60. The difference between the CO(TD) and CO(DP), when all data were included, was -0.04 +/- 0.22 L minute-1 and Pearson's correlation coefficient (r) was 0.86. The difference between the CO(TD) and CO(DA) was -0.87 +/- 0.54 L minute-1 and r = 0.69. For CO(TD) and CO(DP), the difference was -0.82 +/- 0.59 L minute-1 and r = 0.61.ConclusionDoppler evaluation of pulmonary flow was a clinically acceptable method for assessing the CO in propofol-anesthetized dogs.
Resumo:
Objective: Minimizing resection and preserving leaflet tissue has been previously shown to be beneficial for mitral valve function and leaflet kinematics after repair of acute posterior leaflet prolapse in porcine valves. We examined the effects of different additional methods of mitral valve repair (neochordoplasty, ring annuloplasty, edge-to-edge repair and triangular resection) on hemodynamics at different heart rates in an experimental model. Methods: Severe acute P2 prolapse was created in eight porcine mitral valves by resecting the posterior marginal chordae. Valve hemodynamics was quantified under pulsatile conditions in an in vitro heart simulator before and after surgical manipulation. Mitral regurgitation was corrected using four different methods of repair on the same valve: neochordoplasty with expanded polytetrafluoroethylene sutures alone and together with ring annuloplasty, edge-to-edge repair and triangular resection, both with non-restrictive annuloplasty. Residual mitral valve leak, trans-valvular pressure gradients, flow and cardiac output were measured at 60 and 80 beats/min. A validated statistical linear mixed model was used to analyze the effect of treatment. The p values were calculated using a two-sided Wald test. Results: Only neochordoplasty with expanded polytetrafluoroethylene sutures but without ring annuloplasty achieved similar hemodynamics compared to those of the native mitral valve (p range 0.071-0.901). Trans-valvular diastolic pressure gradients were within a physiologic range but significantly higher than those of the native valve following neochordoplasty with ring annuloplasty (p=0.000), triangular resection (p=0.000) and edge-to-edge repair (p=0.000). Neochordoplasty alone was significantly better in terms of hemodynamic than neochordoplasty with a ring annuloplasty (p=0.000). These values were stable regardless of heart rate or ring size. Conclusions: Neochordoplasty without ring annuloplasty is the only repair technique able to achieve almost native physiological hemodynamics after correction of leaflet prolapse in a porcine experimental model of acute chordal rupture.
Resumo:
Objective: Cardiac impairment is frequently found in babies of diabetic mothers. It is still controversial whether this is due to poor glucose control. The aim of this study is to compare the cardiac function in fetuses of well- and poorly-controlled pre-gestational diabetic pregnancy in third trimester. Methods:Women with type 1 pre-gestational diabetes were enrolled at 30-32 weeks. Cardiac size and interventricular septal wall thickness were measured by M-mode at end-diastolic phase. The right and left ventricular ejection fractions were calculated. At the mitral and tricuspid valves inflow, the ratio between early ventricular filling and active atrial filling (E/A) at both atrioventricular valves were measured by Doppler echocardiography. Peak velocities of ascending aorta and pulmonary artery were assessed. The angle of isonation was kept at 6.5%) were compared with those with satisfactorily controlled diabetes (HbA1c less than or equal to 6.5%). Results: A total of 21 women with pre-gestational diabetes were recruited for this study. Eight women with well-controlled diabetes were compared with 9 women who had poorly-controlled diabetes. HbA1c in the poorly-controlled group was 7.3% and in the well-controlled group it was 5.4% (p < 0.001). There was no difference between the two groups in cardiac size, interventricular septal wall thickness, ejection fraction, aorta and pulmonary artery peak flow velocities. The right atrioventricular E/A ratio was significantly lower among the poorly-controlled diabetic pregnancies (0.71 vs. 0.54; p < 0.05). Conclusion: Fetuses of poorly-controlled diabetic mothers had a lower right atrioventricular E/A ratio. This may be due to metabolic acidosis, non-hypertrophic cardiac dysfunction or fetal polycythemia. Copyright (C) 2003 S. Karger AG, Basel.