857 resultados para CYCLIST, ENDURANCE PERFORMANCE, OXYGEN UPTAKE, SHORTTERM
Resumo:
Chemical looping combustion (CLC) is a novel combustion technology that involves cyclic reduction and oxidation of oxygen storage materials to provide oxygen for the combustion of fuels to CO2 and H2O, whilst giving a pure stream of CO2 suitable for sequestration or utilisation. Here, we report a method for preparing of oxygen storage materials from layered double hydroxides (LDHs) precursors and demonstrate their applications in the CLC process. The LDHs precursor enables homogeneous mixing of elements at the molecular level, giving a high degree of dispersion and high-loading of active metal oxide in the support after calcination. Using a Cu-Al LDH precursor as a prototype, we demonstrate that rational design of oxygen storage materials by material chemistry significantly improved the reactivity and stability in the high temperature redox cycles. We discovered that the presence of sodium-containing species were effective in inhibiting the formation of copper aluminates (CuAl2O4 or CuAlO 2) and stabilising the copper phase in an amorphous support over multiple redox cycles. A representative nanostructured Cu-based oxygen storage material derived from the LDH precursor showed stable gaseous O2 release capacity (∼5 wt%), stable oxygen storage capacity (∼12 wt%), and stable reaction rates during reversible phase changes between CuO-Cu 2O-Cu at high temperatures (800-1000 °C). We anticipate that the strategy can be extended to manufacture a variety of metal oxide composites for applications in novel high temperature looping cycles for clean energy production and CO2 capture. © The Royal Society of Chemistry 2013.
Resumo:
The reaction rates of MTPP with oxygen in air are Inas than that with pure oxygen, the ratio is roughly the same as to the partial presence of imygen in air, The influences of S-ligand etbanethiol and O- litand Vc on the above Systems have also been investigated, the former makes the MP hands having more changes and the reaction rate constants becoming greater, the latter has less influence.
Resumo:
Burnley, M., Doust, J., Vanhatalo, A., A 3-min all-out test to determine peak oxygen uptake and the maximal steady state, Medicine & Science in Sports & Exercise. 38(11):1995-2003, November 2006. RAE2008
Resumo:
The role of psychological strategies on endurance performance and cognitive function in the heat is unclear. This thesis tested the effects of a two-week motivational self-talk (MST) intervention - specific to heat stress - on endurance capacity and cognitive function in the heat (35°C 50% RH). The study utilized a pre-test / post-test design testing endurance capacity using a time to exhaustion test (TTE) after exercise-induced hyperthermia. Cognitive function (e.g executive function) was tested at baseline in thermoneutral (22°C 30% RH), before (R1) and after the TTE (R2). MST led to a significant improvement (~30%) in TTE and significantly faster completion time with fewer errors made on executive function tasks at baseline and R2, but not in R1, while there were no differences in the control group. Overall, these results indicate that using a top-down regulation strategy consisting of self-contextualized MST can improve physical and cognitive performance in the heat.
Resumo:
OBJETIVO: Determinar a acurácia das variáveis: tempo de escada (tTE), potência de escada (PTE), teste de caminhada (TC6) e volume expiratório forçado (VEF1) utilizando o consumo máximo de oxigênio (VO2máx) como padrão-ouro. MÉTODOS: Os testes foram realizados em 51 pacientes. O VEF1 foi obtido através da espirometria. O TC6 foi realizado em corredor plano de 120m. O TE foi realizado em escada de 6 lances obtendo-se tTE e PTE. O VO2máx foi obtido por ergoespirometria, utilizando o protocolo de Balke. Foram calculados a correlação linear de Pearson (r) e os valores de p, entre VO2máx e variáveis. Para o cálculo da acurácia, foram obtidos os pontos de corte, através da curva característica operacional (ROC). A estatística Kappa (k) foi utilizada para cálculo da concordância. RESULTADOS: Obteve-se as acurácias: tTE - 86%, TC6 - 80%, PTE - 71%, VEF1(L) - 67%, VEF1% - 63%. Para o tTE e TC6 combinados em paralelo, obteve-se sensibilidade de 93,5% e em série, especificidade de 96,4%. CONCLUSÃO: O tTE foi a variável que apresentou a melhor acurácia. Quando combinados o tTE e TC6 podem ter especificidade e sensibilidade próxima de 100%. Estes testes deveriam ser mais usados rotineiramente, especialmente quando a ergoespirometria para a medida de VO2máx não é disponível.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The aims of this study were: (1) to verify the validity of previous proposed models to estimate the lowest exercise duration (T (LOW)) and the highest intensity (I (HIGH)) at which VO(2)max is reached (2) to test the hypothesis that parameters involved in these models, and hence the validity of these models are affected by aerobic training status. Thirteen cyclists (EC), eleven runners (ER) and ten untrained (U) subjects performed several cycle-ergometer exercise tests to fatigue in order to determine and estimate T (LOW) (ET (LOW)) and I (HIGH) (EI (HIGH)). The relationship between the time to achieved VO(2)max and time to exhaustion (T (lim)) was used to estimate ET (LOW). EI (HIGH) was estimated using the critical power model. I (HIGH) was assumed as the highest intensity at which VO2 was equal or higher than the average of VO(2)max values minus one typical error. T (LOW) was considered T (lim) associated with I (HIGH). No differences were found in T (LOW) between ER (170 +/- 31 s) and U (209 +/- 29 s), however, both showed higher values than EC (117 +/- 29 s). I (HIGH) was similar between U (269 +/- 73 W) and ER (319 +/- 50 W), and both were lower than EC (451 +/- 33 W). EI (HIGH) was similar and significantly correlated with I-HIGH only in U (r = 0.87) and ER (r = 0.62). ET (LOW) and T (LOW) were different only for U and not significantly correlated in all groups. These data suggest that the aerobic training status affects the validity of the proposed models for estimating I (HIGH).
Resumo:
Evaporative water loss (EWL) and oxygen uptake ((V) over dot o(2)) was measured in two species of tree frogs with cranial co-ossification, Aparasphenodon brunoi and Corythomantis greeningi. Both species use their head to seal the entrance of bromeliads, tree holes or rocky crevices used as shelters. EWL was significantly reduced in sheltered individuals of both species as compared with those exposed nude to desiccation. EWL per unit area through the head surface was significantly lower than the body skin for A. brunoi but not for C., greeningi. EWL per unit surface area through C. greeningi body skin was about 50% that of A. brunoi, indicating a less permeable skin in the former species. The relationship between cranial coossification and EWL is discussed. ((V) over dot o(2)) in A. brunoi was comparable with other anurans of similar size, whereas in C. greeningi, it was lower than predicted from body mass. Moreover, ((V) over dot o(2)), in C. greeningi showed less sensitivity to temperature increase than in A. brunoi. C. greeningi occurs in a drier environment than A. brunoi, and this appears to be reflected in their EWL and ((V) over dot o(2)) characteristics. (C) 1997 Elsevier B.V.
Resumo:
Oxygen uptake of the fossorial blind snake (Typhlops reticulatus) and the semifossorial coral snake (Micrurus ibiboboca) was measured at 20 and 30 degrees C. Oxygen uptake of blind snakes was within the normal range, whereas oxygen uptake of coral snakes was in the lower end of values reported for snakes. The results do not support the hypothesis of reduced oxygen uptake in fossorial reptiles.
Resumo:
The scaling of oxygen uptake was measured along the ontogeny, in the neotropical pitviper Bothrops moojeni. Allometric relationship between oxygen uptake and body mass, quantified for juveniles, sub-adults and adults, showed the same mass coefficient and exponent. The uniformity of mass constants along ontogeny suggests that B. moojeni is energetically homomorphic. Variation in mass seem to be the sole determinant of oxygen uptake, and structural modifications have no effect on the metabolic rate. Applications of the homomorphism principle to assess variations in mass coefficient and exponent for intraspecific analysis of metabolism in reptiles are discussed. B. moojeni had an oxygen consumption in the range reported for viperids, but lower than that for colubrid snakes of similar size. Possible causative reasons for this pattern is discussed.
Resumo:
Respiratory rates of individual workers of Camponotus rufipes Fabricius (Hymenoptera: Formicidae) were measured at 25-degrees-C and LD 12:12 h (lights on 06.00 hours), DL 12:12 h (lights on 18.00 hours), LL (850 lux) and DD (red light, 20-30 lux), using the micro-Warburg technique. Worker ants were collected from natural nest during the winter of 1987 in a woodland park in the region of Rio Claro, São Paulo, Brazil. The respiration of ants showed a circadian rhythm with acrophase ranging from 20 h 41 min to 01 h 18 min and from 10 h 32 min to 12 h 22 min at LD and DD, respectively. In constant darkness the rhythmometric variables were similar to those presented by ants kept at LD 12:12 h. Under constant light no circadian rhythm in the respiration rates was found. A reduction in the amplitude was observed, indicating an inhibitory effect of this light regime on the respiration process.
Resumo:
In southeastern Brazil the leptodactylid frogs Leptodactylus fuscus and Physalaemus fuscomaculatus enter dormancy during the dry season. Oxygen uptake was measured in awake and dormant groups of both species in a temperature range at which these frogs are usually exposed throughout the year. Oxygen uptake was lower for dormant groups at high temperature, and a lack of response to temperature was reported between 20 - 25 C in the dormant group of both species. This temperature-intensitive range can be considered an adaptive feature to save fat reserves during dormancy.
Resumo:
We have measured hemoglobin oxygen uptake vs. The partial pressure of oxygen, with independently controlled activities of chloride and water. This control is effected by combining different concentrations of NaCl and sucrose in the bathing solution to achieve: (i) water activities were varied and CI- activity was fixed, (ii) both water and CI- activities were varied with a traditional NaCI titration, or (iii) CI- activities were varied and water activity was fixed by adding compensating sucrose. Within this analysis, the CI--regulated loading of four oxygens can be described by the reaction Hb.CI- + 4 O-2 + 65 H2O reversible arrow Hb.4O(2).65H(2)O + CI-. The dissociation of a neatly integral chloride, rather than the nonintegral 1.6 chlorides inferred earlier from simple salt titration, demonstrates the need to recognize the potentially large contribution from changes in water activity when titrating weakly binding solutes. The single-chloride result might simplify structural considerations of the action of CI- in hemoglobin regulation.