984 resultados para CT value
Resumo:
PURPOSE: The aim of this study was to evaluate ECG-gated whole chest CTA as a routine triage tool for patients with acute chest pain. MATERIAL AND METHODS: Whole chest CTA with retrospective ECG-gating was performed in 30 patients with acute atypical chest pain. The ten main segments of the coronary arteries, the pulmonary arteries, the aorta, and the myocardium (function, morphology) were independently analyzed by a resident and two senior radiologists. The inter-observer agreement between resident and senior radiologists was calculated. A final diagnosis was determined by consensus. RESULTS: Thirty patients were included. The coronary artery segments, myocardium and pulmonary arteries were considered analyzable in 84%, 90% and 97% of cases respectively. A final diagnosis for the cause of pain was retained in 19 patients: significant coronary artery stenosis (5), pulmonary embolus (5), aortic dissection (1), hypokinetic cardiomyopathy (2), lung parenchymal abnormalities (5), and hiatus hernia (1). Inter-observer agreement ranged from 0.76 to 1 between senior radiologists and from 0.76 to 1 between resident and senior radiologists. The average time of image interpretation ranged from 14 to 15 minutes. CONCLUSION: ECG-gated whole chest CT angiography appears as a promising tool for the evaluation of acute chest pain. Combined evaluation of appearance and function of the myocardium can reveal additional interesting information.
Resumo:
Aims: To develop clinical protocols for acquiring PET images, performing CT-PET registration and tumour volume definition based on the PET image data, for radiotherapy for lung cancer patients and then to test these protocols with respect to levels of accuracy and reproducibility. Method: A phantom-based quality assurance study of the processes associated with using registered CT and PET scans for tumour volume definition was conducted to: (1) investigate image acquisition and manipulation techniques for registering and contouring CT and PET images in a radiotherapy treatment planning system, and (2) determine technology-based errors in the registration and contouring processes. The outcomes of the phantom image based quality assurance study were used to determine clinical protocols. Protocols were developed for (1) acquiring patient PET image data for incorporation into the 3DCRT process, particularly for ensuring that the patient is positioned in their treatment position; (2) CT-PET image registration techniques and (3) GTV definition using the PET image data. The developed clinical protocols were tested using retrospective clinical trials to assess levels of inter-user variability which may be attributed to the use of these protocols. A Siemens Somatom Open Sensation 20 slice CT scanner and a Philips Allegro stand-alone PET scanner were used to acquire the images for this research. The Philips Pinnacle3 treatment planning system was used to perform the image registration and contouring of the CT and PET images. Results: Both the attenuation-corrected and transmission images obtained from standard whole-body PET staging clinical scanning protocols were acquired and imported into the treatment planning system for the phantom-based quality assurance study. Protocols for manipulating the PET images in the treatment planning system, particularly for quantifying uptake in volumes of interest and window levels for accurate geometric visualisation were determined. The automatic registration algorithms were found to have sub-voxel levels of accuracy, with transmission scan-based CT-PET registration more accurate than emission scan-based registration of the phantom images. Respiration induced image artifacts were not found to influence registration accuracy while inadequate pre-registration over-lap of the CT and PET images was found to result in large registration errors. A threshold value based on a percentage of the maximum uptake within a volume of interest was found to accurately contour the different features of the phantom despite the lower spatial resolution of the PET images. Appropriate selection of the threshold value is dependant on target-to-background ratios and the presence of respiratory motion. The results from the phantom-based study were used to design, implement and test clinical CT-PET fusion protocols. The patient PET image acquisition protocols enabled patients to be successfully identified and positioned in their radiotherapy treatment position during the acquisition of their whole-body PET staging scan. While automatic registration techniques were found to reduce inter-user variation compared to manual techniques, there was no significant difference in the registration outcomes for transmission or emission scan-based registration of the patient images, using the protocol. Tumour volumes contoured on registered patient CT-PET images using the tested threshold values and viewing windows determined from the phantom study, demonstrated less inter-user variation for the primary tumour volume contours than those contoured using only the patient’s planning CT scans. Conclusions: The developed clinical protocols allow a patient’s whole-body PET staging scan to be incorporated, manipulated and quantified in the treatment planning process to improve the accuracy of gross tumour volume localisation in 3D conformal radiotherapy for lung cancer. Image registration protocols which factor in potential software-based errors combined with adequate user training are recommended to increase the accuracy and reproducibility of registration outcomes. A semi-automated adaptive threshold contouring technique incorporating a PET windowing protocol, accurately defines the geometric edge of a tumour volume using PET image data from a stand alone PET scanner, including 4D target volumes.
Resumo:
There is a growing interest in the use of megavoltage cone-beam computed tomography (MV CBCT) data for radiotherapy treatment planning. To calculate accurate dose distributions, knowledge of the electron density (ED) of the tissues being irradiated is required. In the case of MV CBCT, it is necessary to determine a calibration-relating CT number to ED, utilizing the photon beam produced for MV CBCT. A number of different parameters can affect this calibration. This study was undertaken on the Siemens MV CBCT system, MVision, to evaluate the effect of the following parameters on the reconstructed CT pixel value to ED calibration: the number of monitor units (MUs) used (5, 8, 15 and 60 MUs), the image reconstruction filter (head and neck, and pelvis), reconstruction matrix size (256 by 256 and 512 by 512), and the addition of extra solid water surrounding the ED phantom. A Gammex electron density CT phantom containing EDs from 0.292 to 1.707 was imaged under each of these conditions. The linear relationship between MV CBCT pixel value and ED was demonstrated for all MU settings and over the range of EDs. Changes in MU number did not dramatically alter the MV CBCT ED calibration. The use of different reconstruction filters was found to affect the MV CBCT ED calibration, as was the addition of solid water surrounding the phantom. Dose distributions from treatment plans calculated with simulated image data from a 15 MU head and neck reconstruction filter MV CBCT image and a MV CBCT ED calibration curve from the image data parameters and a 15 MU pelvis reconstruction filter showed small and clinically insignificant differences. Thus, the use of a single MV CBCT ED calibration curve is unlikely to result in any clinical differences. However, to ensure minimal uncertainties in dose reporting, MV CBCT ED calibration measurements could be carried out using parameter-specific calibration measurements.
Resumo:
There is growing evidence that focal thinning of cortical bone in the proximal femur may predispose a hip to fracture. Detecting such defects in clinical CT is challenging, since cortices may be significantly thinner than the imaging system's point spread function. We recently proposed a model-fitting technique to measure sub-millimetre cortices, an ill-posed problem which was regularized by assuming a specific, fixed value for the cortical density. In this paper, we develop the work further by proposing and evaluating a more rigorous method for estimating the constant cortical density, and extend the paradigm to encompass the mapping of cortical mass (mineral mg/cm(2)) in addition to thickness. Density, thickness and mass estimates are evaluated on sixteen cadaveric femurs, with high resolution measurements from a micro-CT scanner providing the gold standard. The results demonstrate robust, accurate measurement of peak cortical density and cortical mass. Cortical thickness errors are confined to regions of thin cortex and are bounded by the extent to which the local density deviates from the peak, averaging 20% for 0.5mm cortex.
Resumo:
There is growing evidence that focal thinning of cortical bone in the proximal femur may predispose a hip to fracture. Detecting such defects in clinical CT is challenging, since cortices may be significantly thinner than the imaging system's point spread function. We recently proposed a model-fitting technique to measure sub-millimetre cortices, an ill-posed problem which was regularized by assuming a specific, fixed value for the cortical density. In this paper, we develop the work further by proposing and evaluating a more rigorous method for estimating the constant cortical density, and extend the paradigm to encompass the mapping of cortical mass (mineral mg/cm 2) in addition to thickness. Density, thickness and mass estimates are evaluated on sixteen cadaveric femurs, with high resolution measurements from a micro-CT scanner providing the gold standard. The results demonstrate robust, accurate measurement of peak cortical density and cortical mass. Cortical thickness errors are confined to regions of thin cortex and are bounded by the extent to which the local density deviates from the peak, averaging 20% for 0.5mm cortex. © 2012 Elsevier B.V.
Resumo:
PURPOSE:
The aim of the study was to compare the pre-operative metabolic tumour length on FDG PET/CT with the resected pathological specimen in patients with oesophageal cancer.
METHODS:
All patients diagnosed with oesophageal carcinoma who had undergone staging PET/CT imaging between the period of June 2002 and May 2008 who were then suitable for curative surgery, either with or without neo-adjuvant chemotherapy, were included in this study. Metabolic tumour length was assessed using both visual analysis and a maximum standardised uptake value (SUV(max)) cutoff of 2.5.
RESULTS:
Thirty-nine patients proceeded directly to curative surgical resection, whereas 48 patients received neo-adjuvant chemotherapy, followed by curative surgery. The 95% limits of agreement in the surgical arm were more accurate when the metabolic tumour length was visually assessed with a mean difference of -0.05 cm (SD 2.16 cm) compared to a mean difference of +2.42 cm (SD 3.46 cm) when assessed with an SUV(max) cutoff of 2.5. In the neo-adjuvant group, the 95% limits of agreement were once again more accurate when assessed visually with a mean difference of -0.6 cm (SD 1.84 cm) compared to a mean difference of +1.58 cm (SD 3.1 cm) when assessed with an SUV(max) cutoff of 2.5.
CONCLUSION:
This study confirms the high accuracy of PET/CT in measuring gross target volume (GTV) length. A visual method for GTV length measurement was demonstrated to be superior and more accurate than when using an SUV(max) cutoff of 2.5. This has the potential of reducing the planning target volume with dose escalation to the tumour with a corresponding reduction in normal tissue complication probability.
Resumo:
Introduction
PET-computed tomography (PET-CT) is a useful staging imaging modality in colorectal liver metastases (CRLM). This study aimed to determine whether PET-CT parameters, standardized uptake value (SUV) and reconstructed tumour volume (RTV), are predictors of prognosis and survival.
Methods
A study of all resectable CRLM patients in the regional HPB unit from 2007–2009 was performed. Preoperative PET-CT scans were retrospectively reviewed; SUV, diameter and RTV for each lesion was recorded. Correlation analysis was performed with other pathological and biochemical parameters, by Pearson’s correlation analysis. Survival analysis was performed using Cox regression hazard model. A P value of less than 0.05 was considered statistically significant.
Results
A total of 79 patients were included. SUV moderately correlated with tumour diameter, both PET-CT (r=0.4927; P<0.0001) and histology (r=0.4513; P=0.0003); RTV (r=0.4489; P<0.001), preoperative carcinoembryonic antigen (CEA) (r=0.4977; P=0.0001), and postoperative CEA (r=0.3727; P=0.004). Multivariate analysis found that an independent predictor of SUVmax was preoperative CEA (P=0.03). RTV strongly correlated with preoperative CEA (r=0.9389; P<0.0001). SUV and RTV had a negative effect on survival.
Conclusion
PET-CT, in the setting of CRLM, may have a prognostic role in assessing survival. Although no definite conclusions can be drawn regarding the prognostic role of SUV and RTV, it acts to reinforce the need for further prospective studies to validate these findings.
Resumo:
Background and purpose: We are developing a technique for highly focused vocal cord irradiation in early glottic carcinoma to optimally treat a target volume confined to a single cord. This technique, in contrast with the conventional methods, aims at sparing the healthy vocal cord. As such a technique requires sub-mm daily targeting accuracy to be effective, we investigate the accuracy achievable with on-line kV-cone beam CT (CBCT) corrections. Materials and methods: CBCT scans were obtained in 10 early glottic cancer patients in each treatment fraction. The grey value registration available in X-ray volume imaging (XVI) software (Elekta, Synergy) was applied to a volume of interest encompassing the thyroid cartilage. After application of the thus derived corrections, residue displacements with respect to the planning CT scan were measured at clearly identifiable relevant landmarks. The intra- and inter-observer variations were also measured. Results: While before correction the systematic displacements of the vocal cords were as large as 2.4 ± 3.3 mm (cranial-caudal population mean ± SD Σ), daily CBCT registration and correction reduced these values to less than 0.2 ± 0.5 mm in all directions. Random positioning errors (SD σ) were reduced to less than 1 mm. Correcting only for translations and not for rotations did not appreciably affect this accuracy. The residue random displacements partly stem from intra-observer variations (SD = 0.2-0.6 mm). Conclusion: The use of CBCT for daily image guidance in combination with standard mask fixation reduced systematic and random set-up errors of the vocal cords to <1 mm prior to the delivery of each fraction dose. Thus, this facilitates the high targeting precision required for a single vocal cord irradiation. © 2009 Elsevier Ireland Ltd. All rights reserved.
Resumo:
OBJECTIVES: To improve understanding about the potential underlying biological mechanisms in the link between depression and all-cause mortality and to investigate the role that inflammatory and other cardiovascular risk factors may play in the relationship between depressive symptoms and mortality.
METHODS: Depression and blood-based biological markers were assessed in the Belfast PRIME prospective cohort study (N = 2389 men, aged 50-59 years) in which participants were followed up for 18 years. Depression was measured using the 10-item Welsh Pure Depression Inventory. Inflammation markers (C-reactive protein [CRP], neopterin, interleukin [IL]-1 receptor antagonist [IL-1Ra], and IL-18) and cardiovascular-specific risk factors (N-terminal pro-b-type natriuretic peptide, midregion pro-atrial natriuretic peptide, midregion pro-adrenomedullin, C-terminal pro-endothelin-1 [CT-proET]) were obtained at baseline. We used Cox proportional hazards modeling to examine the association between depression and biological measures in relation to all-cause mortality and explore the mediating effects.
RESULTS: During follow-up, 418 participants died. Higher levels of depressive symptoms were associated with higher levels of CRP, IL-1Ra, and CT-proET. After adjustment for socioeconomic and life-style risk factors, depressive symptoms were significantly associated with all-cause mortality (hazard ratio = 1.10 per scale unit, 95% confidence interval = 1.04-1.16). This association was partly explained by CRP (7.3%) suggesting a minimal mediation effect. IL-1Ra, N-terminal pro-b-type natriuretic peptide, midregion pro-atrial natriuretic peptide, midregion pro-adrenomedullin, and CT-proET contributed marginally to the association between depression and subsequent mortality.
CONCLUSIONS: Inflammatory and cardiovascular risk markers are associated with depression and with increased mortality. However, depression and biological measures show additive effects rather than a pattern of meditation of biological factors in the association between depression and mortality.
Resumo:
Coronary CT angiography is widely used in clinical practice for the assessment of coronary artery disease. Several studies have shown that the same exam can also be used to assess left ventricle (LV) function. LV function is usually evaluated using just the data from end-systolic and end-diastolic phases even though coronary CT angiography (CTA) provides data concerning multiple cardiac phases, along the cardiac cycle. This unused wealth of data, mostly due to its complexity and the lack of proper tools, has still to be explored in order to assess if further insight is possible regarding regional LV functional analysis. Furthermore, different parameters can be computed to characterize LV function and while some are well known by clinicians others still need to be evaluated concerning their value in clinical scenarios. The work presented in this thesis covers two steps towards extended use of CTA data: LV segmentation and functional analysis. A new semi-automatic segmentation method is presented to obtain LV data for all cardiac phases available in a CTA exam and a 3D editing tool was designed to allow users to fine tune the segmentations. Regarding segmentation evaluation, a methodology is proposed in order to help choose the similarity metrics to be used to compare segmentations. This methodology allows the detection of redundant measures that can be discarded. The evaluation was performed with the help of three experienced radiographers yielding low intraand inter-observer variability. In order to allow exploring the segmented data, several parameters characterizing global and regional LV function are computed for the available cardiac phases. The data thus obtained is shown using a set of visualizations allowing synchronized visual exploration. The main purpose is to provide means for clinicians to explore the data and gather insight over their meaning, as well as their correlation with each other and with diagnosis outcomes. Finally, an interactive method is proposed to help clinicians assess myocardial perfusion by providing automatic assignment of lesions, detected by clinicians, to a myocardial segment. This new approach has obtained positive feedback from clinicians and is not only an improvement over their current assessment method but also an important first step towards systematic validation of automatic myocardial perfusion assessment measures.
Resumo:
Introdução – O melanoma maligno cutâneo (MMC) é considerado uma das mais letais neoplasias e no seu seguimento recorre-se, para além dos exames clínicos e da análise de marcadores tumorais, a diversos métodos imagiológicos, como é o exame Tomografia por Emissão de Positrões/Tomografia Computorizada (PET/CT, do acrónimo inglês Positron Emission Tomography/Computed Tomography) com 18fluor-fluorodeoxiglucose (18F-FDG). O presente estudo tem como objetivo avaliar a utilidade da PET/CT relativamente à análise da extensão e à suspeita de recidiva do MMC, comparando os achados imagiológicos com os descritos em estudos CT. Metodologia – Estudo retrospetivo de 62 estudos PET/CT realizados em 50 pacientes diagnosticados com MMC. Excluiu-se um estudo cujo resultado era duvidoso (nódulo pulmonar). As informações relativas aos resultados dos estudos anatomopatológicos e dos exames imagiológicos foram obtidas através da história clínica e dos relatórios médicos dos estudos CT e PET/CT. Foi criada uma base de dados com os dados recolhidos através do software Excel e foi efetuada uma análise estatística descritiva. Resultados – Dos estudos PET/CT analisados, 31 foram considerados verdadeiros positivos (VP), 28 verdadeiros negativos (VN), um falso positivo (FP) e um falso negativo (FN). A sensibilidade, especificidade, o valor preditivo positivo (VPP), o valor preditivo negativo (VPN) e a exatidão da PET/CT para o estadiamento e avaliação de suspeita de recidiva no MMC são, respetivamente, 96,9%, 96,6%, 96,9%, 96,6% e 96,7%. Dos resultados da CT considerados na análise estatística, 14 corresponderam a VP, 12 a VN, três a FP e cinco a FN. A sensibilidade, especificidade, o VPP e o VPN e a exatidão da CT para o estadiamento e avaliação de suspeita de recidiva no MMC são, respetivamente, 73,7%, 80,0%, 82,4%, 70,6% e 76,5%. Comparativamente aos resultados CT, a PET/CT permitiu uma mudança na atitude terapêutica em 23% dos estudos. Conclusão – A PET/CT é um exame útil na avaliação do MMC, caracterizando-se por uma maior acuidade diagnóstica no estadiamento e na avaliação de suspeita de recidiva do MMC comparativamente à CT isoladamente.
Resumo:
Objectif: Nous avons effectué une étude chez 135 patients ayant subis une chirurgie lombo-sacrée avec vissage pédiculaire sous navigation par tomographie axiale. Nous avons évalué la précision des vis pédiculaires et les résultats cliniques. Méthodes: Cette étude comporte 44 hommes et 91 femmes (âge moyen=61, intervalle 24-90 ans). Les diamètres, longueurs et trajectoires des 836 vis ont été planifiés en préopératoire avec un système de navigation (SNN, Surgical Navigation Network, Mississauga). Les patients ont subi une fusion lombaire (55), lombo-sacrée (73) et thoraco-lombo-sacrée (7). La perforation pédiculaire, la longueur des vis et les spondylolisthesis sont évalués par tomographies axiales postopératoires. Le niveau de douleur est mesuré par autoévaluations, échelles visuelles analogues et questionnaires (Oswestry et SF-36). La fusion osseuse a été évaluée par l’examen des radiographies postopératoires. Résultats: Une perforation des pédicules est présente pour 49/836 (5.9%) des vis (2.4% latéral, 1.7% inférieur, 1.1% supérieur, 0.7% médial). Les erreurs ont été mineures (0.1-2mm, 46/49) ou intermédiaires (2.1 - 4mm, 3/49 en latéral). Il y a aucune erreur majeure (≥ 4.1mm). Certaines vis ont été jugées trop longues (66/836, 8%). Le temps moyen pour insérer une vis en navigation a été de 19.1 minutes de l΄application au retrait du cadre de référence. Un an postopératoire on note une amélioration de la douleur des jambes et lombaire de 72% et 48% en moyenne respectivement. L’amélioration reste stable après 2 ans. La dégénérescence radiologique au dessus et sous la fusion a été retrouvée chez 44 patients (33%) and 3 patients respectivement (2%). Elle est survenue en moyenne 22.2 ± 2.6 mois après la chirurgie. Les fusions se terminant à L2 ont été associées à plus de dégénération (14/25, 56%). Conclusion: La navigation spinale basée sur des images tomographiques préopératoires est une technique sécuritaire et précise. Elle donne de bons résultats à court terme justifiant l’investissement de temps chirurgical. La dégénérescence segmentaire peut avoir un impact négatif sur les résultats radiologique et cliniques.
Resumo:
Tout en voulant inclure la fiction télévisuelle brésilienne parmi les fictions de qualité, cette recherche analyse l’émergence et l’évolution du concept de qualité dans le panorama télévisuel brésilien. Examinant l’histoire de la télédramaturgie au Brésil, depuis les téléthéâtres jusqu’aux microséries réalisées par Luiz Fernando Carvalho, en particulier la microsérie Capitu (2008), nous suggérons que la production fictionnelle brésilienne a atteint un niveau de qualité sophistiquée et avant-gardiste qui illustre une alternative au style préconisé par la formule des séries télévisées américaines qui se regroupent sous l’étiquette de la Quality TV. De plus, le raffinement de la microsérie contribue à la légitimation de la valeur artistique de la télévision à partir de caractéristiques télévisuelles, contrairement à la production fictionnelle américaine dont l’esthétique plutôt cinématographique finit par discréditer davantage le petit écran. Finalement, nous souhaitons démontrer l’importance des innovations esthétiques que cette microsérie a apportées au sein d’une sphère médiatique qui semble se diriger progressivement et rapidement vers l’uniformisation du langage télévisuel et de son contenu.
Resumo:
The registration of pre-operative volumetric datasets to intra- operative two-dimensional images provides an improved way of verifying patient position and medical instrument loca- tion. In applications from orthopedics to neurosurgery, it has a great value in maintaining up-to-date information about changes due to intervention. We propose a mutual information- based registration algorithm to establish the proper align- ment. For optimization purposes, we compare the perfor- mance of the non-gradient Powell method and two slightly di erent versions of a stochastic gradient ascent strategy: one using a sparsely sampled histogramming approach and the other Parzen windowing to carry out probability density approximation. Our main contribution lies in adopting the stochastic ap- proximation scheme successfully applied in 3D-3D registra- tion problems to the 2D-3D scenario, which obviates the need for the generation of full DRRs at each iteration of pose op- timization. This facilitates a considerable savings in compu- tation expense. We also introduce a new probability density estimator for image intensities via sparse histogramming, de- rive gradient estimates for the density measures required by the maximization procedure and introduce the framework for a multiresolution strategy to the problem. Registration results are presented on uoroscopy and CT datasets of a plastic pelvis and a real skull, and on a high-resolution CT- derived simulated dataset of a real skull, a plastic skull, a plastic pelvis and a plastic lumbar spine segment.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)