967 resultados para CHEST
Resumo:
Purpose - To develop and validate a psychometric scale for assessing image quality perception for chest X-ray images. Methods - Bandura's theory was used to guide scale development. A review of the literature was undertaken to identify items/factors which could be used to evaluate image quality using a perceptual approach. A draft scale was then created (22 items) and presented to a focus group (student and qualified radiographers). Within the focus group the draft scale was discussed and modified. A series of seven postero-anterior chest images were generated using a phantom with a range of image qualities. Image quality perception was confirmed for the seven images using signal-to-noise ratio (SNR 17.2–36.5). Participants (student and qualified radiographers and radiology trainees) were then invited to independently score each of the seven images using the draft image quality perception scale. Cronbach alpha was used to test interval reliability. Results - Fifty three participants used the scale to grade image quality perception on each of the seven images. Aggregated mean scale score increased with increasing SNR from 42.1 to 87.7 (r = 0.98, P < 0.001). For each of the 22 individual scale items there was clear differentiation of low, mid and high quality images. A Cronbach alpha coefficient of >0.7 was obtained across each of the seven images. Conclusion - This study represents the first development of a chest image quality perception scale based on Bandura's theory. There was excellent correlation between the image quality perception scores derived using the scale and the SNR. Further research will involve a more detailed item and factor analysis.
Resumo:
Purpose - To compare the image quality and effective dose applying the 10 kVp rule with manual mode acquisition and AEC mode in PA chest X-ray. Method - 68 images (with and without lesions) were acquired using an anthropomorphic chest phantom using a Wolverson Arcoma X-ray unit. These images were compared against a reference image using the 2 alternative forced choice (2AFC) method. The effective dose (E) was calculated using PCXMC software using the exposure parameters and the DAP. The exposure index (lgM provided by Agfa systems) was recorded. Results - Exposure time decreases more when applying the 10 kVp rule with manual mode (50%–28%) when compared with automatic mode (36%–23%). Statistical differences for E between several ionization chambers' combinations for AEC mode were found (p = 0.002). E is lower when using only the right AEC ionization chamber. Considering the image quality there are no statistical differences (p = 0.348) between the different ionization chambers' combinations for AEC mode for images with no lesions. Considering lgM values, it was demonstrated that they were higher when the AEC mode was used compared to the manual mode. It was also observed that lgM values obtained with AEC mode increased as kVp value went up. The image quality scores did not demonstrate statistical significant differences (p = 0.343) for the images with lesions comparing manual with AEC mode. Conclusion - In general the E is lower when manual mode is used. By using the right AEC ionising chamber under the lung the E will be the lowest in comparison to other ionising chambers. The use of the 10 kVp rule did not affect the visibility of the lesions or image quality.
Resumo:
Purpose: To compare image quality and effective dose when the 10 kVp rule is applied with manual and AEC mode in PA chest X-ray. Methods and Materials: A total of 68 images (with and without lesions) were acquired of an anthropomorphic chest phantom in a Wolverson Arcoma X-ray unit. The images were evaluated against a reference image using image quality criteria and the 2 alternative forced choice (2 AFC) method by five radiographers. The effective dose was calculated using PCXMC software using the exposure parameters and DAP. The exposure index (lgM) was recorded. Results: Exposure time decreases considerably when applying the 10 kVp rule in manual mode (50%-28%) compared to AEC mode (36%-23%). Statistical differences for effective dose between several AEC modes were found (p=0.002). The effective dose is lower when using only the right AEC ionization chamber. Considering image quality, there are no statistical differences (p=0.348) between the different AEC modes for images with no lesions. Using a higher kVp value the lgM values will also increase. The lgM values showed significant statistical differences (p=0.000). The image quality scores did not present statistically significant differences (p=0.043) for the images with lesions when comparing manual with AEC modes. Conclusion: In general, the dose is lower in the manual mode. By using the right AEC ionising chamber the effective dose will be the lowest in comparison to other ionising chambers. The use of the 10 kVp rule did not affect the detectability of the lesions.
Resumo:
Introduction: multimodality environment; requirement for greater understanding of the imaging technologies used, the limitations of these technologies, and how to best interpret the results; dose optimization; introduction of new techniques; current practice and best practice; incidental findings, in low-dose CT images obtained as part of the hybrid imaging process, are an increasing phenomenon with advancing CT technology; resultant ethical and medico-legal dilemmas; understanding limitations of these procedures important when reporting images and recommending follow-up; free-response observer performance study was used to evaluate lesion detection in low-dose CT images obtained during attenuation correction acquisitions for myocardial perfusion imaging, on two hybrid imaging systems.
Resumo:
Objectives: Children have a greater risk from radiation, per unit dose, due to increased radiosensitivity and longer life expectancies. It is of paramount importance to reduce the radiation dose received by children. This research concerns chest CT examinations on paediatric patients. The purpose of this study was to compare the image quality and the dose received from imaging with images reconstructed with filtered back projection (FBP) and five strengths of Sinogram-Affirmed Iterative Reconstruction (SAFIRE). Methods: Using a multi-slice CT scanner, six series of images were taken of a paediatric phantom. Two kVp values (80 and 110), 3 mAs values (25, 50 and 100) and 2 slice thicknesses (1 mm and 3 mm) were used. All images were reconstructed with FBP and five strengths of SAFIRE. Ten observers evaluated visual image quality. Dose was measured using CT-Expo. Results: FBP required a higher dose than all SAFIRE strengths to obtain the same image quality for sharpness and noise. For sharpness and contrast image quality ratings of 4, FBP required doses of 6.4 and 6.8 mSv respectively. SAFIRE 5 required doses of 3.4 and 4.3 mSv respectively. Clinical acceptance rate was improved by the higher voltage (110 kV) for all images in comparison to 80 kV, which required a higher dose for acceptable image quality. 3 mm images were typically better quality than 1 mm images. Conclusion: SAFIRE 5 was optimal for dose reduction and image quality.
Resumo:
Objective - Evaluate preventable exposure dose in routine chest CT examinations beyond prescribed anatomical landmarks and estimate extra dose delivered to the patient. Background/rationale - Recent technical advances have greatly increased the clinical applications of CT; developments in multidetector-row CT (MDCT) technology have occurred; the major disadvantage with the increased use of MDCT is associated radiation exposure.
Resumo:
Purpose - To develop and validate a psychometric scale for assessing image quality for chest radiographs.
Resumo:
We report the case of a 10-year-old girl with two episodes of light-headedness and chest pain during exercise. She had an unremarkable clinical record, physical examination, ECG, and echocardiogram. Noninvasive ischemia tests were positive, but coronary angiography was normal. Exercise stress echocardiogram revealed an exercise-induced intra-left-ventricular obstruction with a peak gradient of 78 mmHg and replicated her symptoms. After starting beta-blocker therapy her clinical status improved and no residual obstruction was detected. The authors review this unsuspected clinical condition, seldom reported in the adult population and, to our knowledge, never before in a child.
Resumo:
Pericardial cysts are rare benign congenital malformations, usually small, asymptomatic and detected incidentally on chest X-ray as a mass located in the right costophrenic angle. Giant pericardial cysts are very uncommon and produce symptoms by compressing adjacent structures. In this report, the authors present a case of a symptomatic giant pericardial cyst incorrectly diagnosed as dextrocardia on chest X-ray.
Resumo:
The correct interpretation of chest film on cardiac patients is very important. The most important feature is the radiographic appearance of the pulmonary vascularity. Four different patterns of pulmonary vascularity are considered: normal, decreased, increased and uneven. The different diseases associated with each type are mentioned. From the pulmonary vascular pattern one can deduct hemodynamic data which are important for the diagnosis, grade of severity and follow-up.
Resumo:
Angiolymphoid hyperplasia with eosinophilia is a rare vascular proliferation characterized by single or multiple purplish, brownish papules and subcutaneous nodules, sometimes associated with pain or pruritus. This rare benign process occurs with a female predominance. Approximately 85% of the lesions occur in the skin of the head and neck; most of them are around the ear or on the forehead or scalp. Whether angiolymphoid hyperplasia with eosinophilia represents a benign neoplasm or an unusual reaction to varied stimuli, including trauma, the etiology remains unclear. Histopathologically, the lesions consist of a proliferation of blood vessels of variable size lined by large epithelioid endothelial cells and a variable inflammatory infiltrate of lymphocytes and eosinophils, sometimes with lymphoid follicle formation. The lesion is benign but may be persistent and is difficult to eradicate. We report on a case of a 58-year-old Caucasian man who presented a purplish pink dome-shaped tumor of size up to 8 cm in diameter located on the chest. We emphasize this case considering the unusual dimensions of the lesion (8 cm diameter) and the atypical location on the chest.
Resumo:
OBJECTIVE: To evaluate the efficiency of a systematic diagnostic approach in patients with chest pain in the emergency room in relation to the diagnosis of acute coronary syndrome (ACS) and the rate of hospitalization in high-cost units. METHODS: One thousand and three consecutive patients with chest pain were screened according to a pre-established process of diagnostic investigation based on the pre-test probability of ACS determinate by chest pain type and ECG changes. RESULTS: Of the 1003 patients, 224 were immediately discharged home because of no suspicion of ACS (route 5) and 119 were immediately transferred to the coronary care united because of ST elevation or left bundle-branch block (LBBB) (route 1) (74% of these had a final diagnosis of acute myocardial infarction [AMI]). Of the 660 patients that remained in the emergency room under observation, 77 (12%) had AMI without ST segment elevation and 202 (31%) had unstable angina (UA). In route 2 (high probability of ACS) 17% of patients had AMI and 43% had UA, whereas in route 3 (low probability) 2% had AMI and 7 % had UA. The admission ECG has been confirmed as a poor sensitivity test for the diagnosis of AMI ( 49%), with a positive predictive value considered only satisfactory (79%). CONCLUSION: A systematic diagnostic strategy, as used in this study, is essential in managing patients with chest pain in the emergency room in order to obtain high diagnostic accuracy, lower cost, and optimization of the use of coronary care unit beds.
Resumo:
PURPOSE: To evaluate the efficacy of a systematic model of care for patients with chest pain and no ST segment elevation in the emergency room. METHODS: From 1003 patients submitted to an algorithm diagnostic investigation by probability of acute ischemic syndrome. We analyzed 600 ones with no elevation of ST segment, then enrolled to diagnostic routes of median (route 2) and low probability (route 3) to ischemic syndrome. RESULTS: In route 2 we found 17% acute myocardial infarction and 43% unstable angina, whereas in route 3 the rates were 2% and 7%, respectively. Patients with normal/non--specific ECG had 6% probability of AMI whereas in those with negative first CKMB it was 7%; the association of the 2 data only reduced it to 4%. In patients in route 2 the diagnosis of AMI could only be ruled out with serial CKMB measurement up to 9 hours, while in route 3 it could be done in up to 3 hours. Thus, sensitivity and negative predictive value of admission CKMB for AMI were 52% and 93%, respectively. About one-half of patients with unstable angina did not disclose objective ischemic changes on admission. CONCLUSION: The use of a systematic model of care in patients with chest pain offers the opportunity of hindering inappropriate release of patients with ACI and reduces unnecessary admissions. However some patients even with normal ECG should not be released based on a negative first CKMB. Serial measurement of CKMB up to 9 hours is necessary in patients with medium probability of AMI.