998 resultados para CELL CAPTURING STENT


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Adherence of bacteria to biomaterials is the first stage in the development of a device-related infection. The adherence of bacterial cells to biomaterials may be influenced by surface characteristics of the cell, its growth conditions and the biomaterial surface chemistry. Following growth in human urine, the cell surface,hydrophobicity and zeta potential of two ureteral stent biofilm isolates, Enterococcus faecalis and Escherichia coli, were significantly altered. In addition, the adherence of human urine-grown Enterococcus faecalis and Escherichia coli to polyurethane was significantly increased by up to 52.1% and 58.6%, respectively. Treatment of the polyurethane with human urine rendered the polymer surface more hydrophilic (mean advancing water contact angle reduced from 97.59 degrees to 26.37 degrees). However, organisms grown in human urine showed less adherence (up to 90.4%) to the treated polymer than those grown in Mueller-Hinton broth. The results presented in this study indicate that in vivo conditions should be simulated as far as possible when carrying out in vitro bacterial adherence assays, especially if assessing novel methods for reduction of adherence. (C) 1997 Elsevier Science B.V.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Sirolimus-eluting stent therapy has achieved considerable success in overcoming coronary artery restenosis. However, there remain a large number of patients presenting with restenosis after the treatment, and the source of its persistence remains unclarified. Although recent evidence supports the contribution of vascular stem/progenitor cells in restenosis formation, their functional and molecular responses to sirolimus are largely unknown.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

La réparation endovasculaire (EVAR) est une technique minimalement invasive permettant de traiter l’anévrisme de l’aorte abdominale (AAA) par l’entremise d’un stent- graft (SG). L’utilisation d’EVAR est actuellement limitée par de fréquentes complications liées à une guérison inadéquate autour de l’implant. Ce manque de guérison est principalement dû au type de recouvrement polymérique des SG, au milieu pro-apoptotique des AAA et à l’accès réduit aux nutriments et à l’oxygène après EVAR. L’objectif de cette thèse consistait à concevoir un revêtement bioactif permettant d’inhiber l’apoptose et stimuler la croissance des cellules musculaires lisses vasculaires (CMLV), pour ainsi favoriser la guérison des tissus vasculaires autour des SG. La chondroïtine-4-sulfate (CS) a d’abord été choisie, car elle a été identifiée comme un médiateur important de la réparation vasculaire. Il a été démontré que la CS en solution influence directement la résistance à l’apoptose des CMLV, en plus de favoriser la différenciation myofibroblastique chez les fibroblastes. Dans le cadre de ce projet, un premier revêtement à base de CS et de collagène a été créé. Bien que le revêtement permettait d’induire une résistance à l’apoptose chez les CMLV, il se désintégrait trop rapidement dans des conditions aqueuses. Une nouvelle méthodologie a donc été adaptée afin de greffer la CS directement sur des surfaces aminées, à l’aide d’un système utilisant un carbodiimide. Dans le but d’accroître la croissance des CMLV à la surface des revêtements, le facteur de croissance de l’épiderme (EGF) a ensuite été sélectionné. En plus de ses propriétés mitogéniques et chimiotactiques, l’EGF stimule la production d’éléments de la matrice extracellulaire, comme le collagène et la fibronectine. De plus, l’activation du récepteur de l’EGF inhibe également l’apoptose des CMLV. L’EGF a donc été greffé sur la CS. Le revêtement de CS+EGF a démontré une bonne uniformité et bioactivité sur des surfaces de verre aminé. iii iv Dans une 3ème étape, afin de permettre de transposer ce revêtement bioactif sur des implants, plusieurs méthodes permettant de créer des groupements d’amines primaires sur les biomatériaux polymériques comme le PET ou le ePTFE ont été étudiées. La polymérisation par plasma a été choisie pour créer le revêtement CS+EGF à la surface de PET. Une fois de plus, celui-ci a permis d’inhiber l’apoptose des CMLV, dans des conditions pro-apoptotiques, et de favoriser la croissance des cellules. Le revêtement de CS et d’EGF, déposé sur des surfaces aminées, possède des caractéristiques biologiques intéressantes et semble donc prometteur pour favoriser une meilleure guérison autour des SG.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Oligonucleotides capturing CD31 endothelial cells (= aptamer) were used for coating of intracoronary stents to improve endothelialization and vascular healing.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

AIMS: Restenosis has been the principal limitation of bare metal stents. Based upon the presumption that platelet and inflammatory cell recruitment initiate neointimal proliferation, we explored a novel polymer coating that reduces cell-stent interactions. The purpose of the present study was to investigate the effect of poly(L-lysine)-graft-poly(ethyleneglycol) (PLL-g-PEG) adsorbed to stent surfaces to reduce neointimal hyperplasia in the porcine restenosis model. METHODS AND RESULTS: Seven animals were instrumented each with 2 stainless steel stents (15 mm length, 2.5-3.5 mm diameter), randomly implanted in 1 major epicardial coronary artery. One stent was dip-coated with PLL-g-PEG, whereas the other stent served as the uncoated control stent. All animals were sacrificed after 6 weeks for histological examination. Neointimal hyperplasia was significantly less (-51%) in the PLL-g-PEG-coated stents (1.15 +/- 0.59 mm2) than in the uncoated control stents (2.33 +/- 1.01 mm2; p < 0.001). Conversely, lumen size was larger in the PLL-g-PEG-coated stents (2.91 +/- 1.17 mm2) than in the uncoated stents (2.04 +/- 0.64 mm2; p < 0.001). High magnification histomorphologic examination revealed no signs of inflammation or thrombus formation in either stent group. CONCLUSIONS: Polymeric steric stabilization of stents with PLL-g-PEG significantly reduces neointimal hyperplasia in the porcine restenosis model. Reduction of cell-stent interactions mediated by PLL-g-PEG appear to improve biocompatibility of stainless steel stents without evidence of adverse inflammatory or prothrombotic effects.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Although rare, stent thrombosis remains a severe complication after stent implantation owing to its high morbidity and mortality. Since the introduction of drug-eluting stents (DES), most interventional centers have noted stent thrombosis up to 3 years after implantation, a complication rarely seen with bare-metal stents. Some data from large registries and meta-analyses of randomized trials indicate a higher risk for DES thrombosis, whereas others suggest an absence of such a risk. Several factors are associated with an increased risk of stent thrombosis, including the procedure itself (stent malapposition and/or underexpansion, number of implanted stents, stent length, persistent slow coronary blood flow, and dissections), patient and lesion characteristics, stent design, and premature cessation of antiplatelet drugs. Drugs released from DES exert distinct biological effects, such as activation of signal transduction pathways and inhibition of cell proliferation. As a result, although primarily aimed at preventing vascular smooth muscle cell proliferation and migration (ie, key factors in the development of restenosis), they also impair reendothelialization, which leads to delayed arterial healing, and induce tissue factor expression, which results in a prothrombogenic environment. In the same way, polymers used to load these drugs have been associated with DES thrombosis. Finally, DES impair endothelial function of the coronary artery distal to the stent, which potentially promotes the risk of ischemia and coronary occlusion. Although several reports raise the possibility of a substantially higher risk of stent thrombosis in DES, evidence remains inconclusive; as a consequence, both large-scale and long-term clinical trials, as well as further mechanistic studies, are needed. The present review focuses on the pathophysiological mechanisms and pathological findings of stent thrombosis in DES.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Intravascular ultrasound of drug-eluting stent (DES) thrombosis (ST) reveals a high incidence of incomplete stent apposition (ISA) and vessel remodeling. Autopsy specimens of DES ST show delayed healing and hypersensitivity reactions. The present study sought to correlate histopathology of thrombus aspirates with intravascular ultrasound findings in patients with very late DES ST. METHODS AND RESULTS: The study population consisted of 54 patients (28 patients with very late DES ST and 26 controls). Of 28 patients with very late DES ST, 10 patients (1020+/-283 days after implantation) with 11 ST segments (5 sirolimus-eluting stents, 5 paclitaxel-eluting stents, 1 zotarolimus-eluting stent) underwent both thrombus aspiration and intravascular ultrasound investigation. ISA was present in 73% of cases with an ISA cross-sectional area of 6.2+/-2.4 mm(2) and evidence of vessel remodeling (index, 1.6+/-0.3). Histopathological analysis showed pieces of fresh thrombus with inflammatory cell infiltrates (DES, 263+/-149 white blood cells per high-power field) and eosinophils (DES, 20+/-24 eosinophils per high-power field; sirolimus-eluting stents, 34+/-28; paclitaxel-eluting stents, 6+/-6; P for sirolimus-eluting stents versus paclitaxel-eluting stents=0.09). The mean number of eosinophils per high-power field was higher in specimens from very late DES ST (20+/-24) than in those from spontaneous acute myocardial infarction (7+/-10), early bare-metal stent ST (1+/-1), early DES ST (1+/-2), and late bare-metal stent ST (2+/-3; P from ANOVA=0.038). Eosinophil count correlated with ISA cross-sectional area, with an average increase of 5.4 eosinophils per high-power field per 1-mm(2) increase in ISA cross-sectional area. CONCLUSIONS: Very late DES thrombosis is associated with histopathological signs of inflammation and intravascular ultrasound evidence of vessel remodeling. Compared with other causes of myocardial infarction, eosinophilic infiltrates are more common in thrombi harvested from very late DES thrombosis, particularly in sirolimus-eluting stents, and correlate with the extent of stent malapposition.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND Definitive fate of the coronary endothelium after implantation of a drug-eluting stent remains unclear, but evidence has accumulated that treatment with rapamycin-eluting stents impairs endothelial function in human coronary arteries. The aim of our study was to demonstrate this phenomenon on functional, morphological and biochemical level in human internal thoracic arteries (ITA) serving as coronary artery model. METHODS After exposure to rapamycin for 20 h, functional activity of ITA rings was investigated using the organ bath technique. Morphological analysis was performed by scanning electron microscopy and evaluated by two independent observers in blinded fashion. For measurement of endothelial nitric oxide synthase (eNOS) release, mammalian target of rapamycin (mTOR) and protein kinase B (PKB) (Akt) activation, Western blotting on human mammary epithelial cells-1 and on ITA homogenates was performed. RESULTS Comparison of the acetylcholine-induced relaxation revealed a significant concentration-dependent decrease to 66 ± 7 % and 36 ± 7 % (mean ± SEM) after 20-h incubation with 1 and 10 μM rapamycin. Electron microscopic evaluation of the endothelial layer showed no differences between controls and samples exposed to 10 μM rapamycin. Western blots after 20-h incubation with rapamycin (10 nM-1 μM) revealed a significant and concentration-dependent reduction of p (Ser 1177)-eNOS (down to 38 ± 8 %) in human mammary epithelial cells (Hmec)-1. Furthermore, 1 μM rapamycin significantly reduced activation of p (Ser2481)-mTOR (58 ± 11 %), p (Ser2481)-mTOR (23 ± 4 %) and p (Ser473)-Akt (38 ± 6 %) in ITA homogenates leaving Akt protein levels unchanged. CONCLUSIONS The present data suggests that 20-h exposure of ITA rings to rapamycin reduces endothelium-mediated relaxation through down-regulation of Akt-phosphorylation via the mTOR signalling axis within the ITA tissue without injuring the endothelial cell layer.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Coronary heart disease is a major cause of morbidity and mortality worldwide. Percutaneous coronary intervention (PCI) has become the most widely used method of coronary artery revascularisation. The use of stents to hold open atherosclerosis induced arterial narrowing has significantly reduced elastic recoil and acute vessel occlusion following balloon angioplasty. However, bare metal stents have been associated with in-stent restenosis attributed to vascular smooth muscle cell (VSMC) hyperplasia and excessive neointimal formation. The resultant luminal renarrowing may manifest clinically with the return of symptoms such as chest pain or shortness of breath. The development of drug eluting stents has significantly reduced the incidence of in-stent restenosis (ISR). Unfortunately the antiproliferative medications used not only inhibit VSMC proliferation but also re-endothelialisation of the stented vessel. In addition, the drug impregnated polymer coating has been associated with a chronic inflammatory response within the vessel wall predisposing patients to stent thrombosis. Thus the identification of novel therapies which promote vessel healing without excessive proliferative or inflammatory response may improve long term outcome and reduce the need for repeated revascularisation. MicroRNAs (miRs) are short (18-25 nucleotide) non-coding RNAs acting to regulate gene expression. By binding to the 3’untranslated region of mRNA they act to fine tune gene expression either by mRNA degradation or translational repression. Originally identified in coordinating tissue development microRNAs have also been shown to play important roles coordinating the inflammatory response and in numerous cardiovascular diseases. MiR-21 has been identified in human atherosclerotic plaques, arteriosclerosis obliterans and abdominal aortic aneurysms. In addition, its up regulation has been documented in preclinical models of vascular injury. This study sought to identify the role of miR-21 in the development of ISR. Utilising a small animal model of stenting and in vitro techniques, we sought to investigate its influence upon VSMC and immune cell response following stenting. 19 The refinement of a murine stenting model within the Baker laboratory and the electrochemical dissolution of the metal stent from within harvested vascular tissues significantly improved the ability to perform detailed histological analysis. In addition, identification of miRNAs using in situ hybridisation was achieved for the first time within stented tissue. Neointimal formation and ISR was significantly reduced in mice in which miR-21 had been genetically deleted. In addition, neointimal composition was found to be altered in miR-21 KO mice with reductions in VSMC and elastin content demonstrated. Importantly, no difference in re-endothelialisation was observed. In vitro analysis demonstrated that VSMCs from miR-21 KO mice had both reduced proliferative and migratory capacity following platelet derived growth factor stimulation. Molecular analysis revealed that these differences may, at least in part, be due to de-repression of programmed cell death 4 (PDCD4). PDCD4 is a known miR-21 target within VSMCs implicated in the suppression of proliferation and promotion of apoptosis. Unfortunately, initial attempts at antimiR mediated knockdown of miR-21 in vivo, failed to produce a similar change in the suppression of ISR. Furthermore, a significant alteration in macrophage polarisation state within the neointima of miR-21 WT and KO mice was noted. Immunohistochemical staining revealed a preponderance of anti-inflammatory M2 macrophages in KO mice. Analysis of bone marrow derived macrophages from miR-21 KO mice demonstrated an increased level of the peroxisome proliferation activating receptor-γ (PPARγ) which facilitates M2 polarisation. Importantly, significant alterations in numerous pro-inflammatory cytokines, which also have mitogenic effects, were also found following genetic deletion of miR-21. In Summary, this is the first study to look at miRs in the development of ISR. MiR-21 plays an important role in the development of ISR by influencing the proliferative response of VSMCs and modulating the immune response following stent deployment. Further attempts to modulate miR-21 expression following PCI may reduce ISR and the need for repeat revascularisation while also reducing the risk of stent thrombosis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This research work analyses techniques for implementing a cell-centred finite-volume time-domain (ccFV-TD) computational methodology for the purpose of studying microwave heating. Various state-of-the-art spatial and temporal discretisation methods employed to solve Maxwell's equations on multidimensional structured grid networks are investigated, and the dispersive and dissipative errors inherent in those techniques examined. Both staggered and unstaggered grid approaches are considered. Upwind schemes using a Riemann solver and intensity vector splitting are studied and evaluated. Staggered and unstaggered Leapfrog and Runge-Kutta time integration methods are analysed in terms of phase and amplitude error to identify which method is the most accurate and efficient for simulating microwave heating processes. The implementation and migration of typical electromagnetic boundary conditions. from staggered in space to cell-centred approaches also is deliberated. In particular, an existing perfectly matched layer absorbing boundary methodology is adapted to formulate a new cell-centred boundary implementation for the ccFV-TD solvers. Finally for microwave heating purposes, a comparison of analytical and numerical results for standard case studies in rectangular waveguides allows the accuracy of the developed methods to be assessed.