806 resultados para Building roof


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

World and UK energy resources and use are reviewed and the role of energy conservation in energy policy identified. In considering various energy conservation measures, a distinction is made between energy intensive and non-intensive industries and also between direct and indirect uses of energy. Particular attention is given to the non-intensive user of energy. Energy use on one such industrial site has been studied to determine the most effective energy saving measures in the short term. Here it is estimated that over 65% of energy is consumed for indirect purposes, mainly for heating and lighting buildings. Emphasis is placed on energy auditing techniques and those energy saving measures requiring greater technical, economic and organisational resources to secure their implementation. Energy auditing techniques include the use of aerial thermography and snow formation surveys to detect heat losses. Qualitative and quantitative interpretations are carried out, but restricted mainly to evaluating building roof heat losses. From the energy auditing exercise, it is confirmed that the intermittent heating of buildings is the largest and most cost effective fuel saving measure. This was implemented on the site and a heat monitoring programme established to verify results. Industrial combined heat and power generation is investigated. A proposal for the site demonstrates that there are several obstacles to its successful implementation. By adopting an alternative financial rationale, a way of overcoming these obstacles is suggested. A useful by-product of the study is the classification of industrial sites according to the nature of industrial energy demand patterns. Finally, energy saving measures implemented on the site are quantlfied using comparative verification methods. Overall fuel savings of 13% are indicated. Cumulative savings in heating fuel amount to 26% over four years although heated area increased by approximately 25%.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The paper shows the design process of Nagele, a Dutch modernist agrarian settlement designed during the Post-Second World War period by the internationally recognized group of architects De 8 en Opbouw: Rietveld, Van Eesteren, Merkelbach, van Eyck, Bakema, Stam, Ruys, etc. It is located in the Noordoostpolder (NOP), in the Flevoland province, which was entirely reclaimed from the sea. The country planning of the Noodoostpolder reveals a high rationalization in the disposal of roads, canals, cities, agrarian land and forests, which can be an inspiration for the cities of today. The configurational elements of Nagele must be understood in terms of their relationship to the overall system of the polder. Important territorial principles in structure, form and landscape can be seen in the project of Nagele. This relationship is an additional example of the continuing transformation that the entire length and breadth of The Netherlands in subjected to. The research developed to date reveals a plan which shows the evolution of functionalistic paradigm at the CIAM postwar congresses. The particular case of Nagele points to the incorporation of human scale, green design and social co-existence. The source of these theories mainly came from Aldo van Eyck, who played an important role during the second phase of design. The research will be developed analyzing his drawings and texts and will show the way his theories appear in the project. Can Nagele be a materialization of Van Eyck¿s ideas? Nagele constitutes one of the most outstanding contributions to modern urban planning as far as both urbanism and landscape, are at the service of human well-being. Not only were urban independently designed parts, but their relationships also formed a perfect urban whole.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Smith, Hinchman & Grylls, architects. W.B. Wood Co., construction.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Built in 1856. First chemical laboratory at a state university. Building served medical students and others as both laboratory and classroom. Situated just west and south of the original medical building. Additions made to the one-story building in 1861, 1866, 1868, 1874. In 1880 a two-story addition was added with subsequent additions in 1889 and 1901. Became Economics Building in 1908. Pharmacology occupied north wing 1908-1981. Destroyed by fire Christmas Eve 1981. View through window to interior and hole in roof.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Built in 1856. First chemical laboratory at a state university. Building served medical students and others as both laboratory and classroom. Situated just west and south of the original medical building. Additions made to the one-story building in 1861, 1866, 1868, 1874. In 1880 a two-story addition was added with subsequent additions in 1889 and 1901. Became Economics Building in 1908. Pharmacology occupied north wing 1908-1981. Destroyed by fire Christmas Eve 1981.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

View to north and east facing wings, along circulation path to the roof feature connection between wings.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Building Integrated Photovoltaics (BIPV) are considered as the future of photovoltaic (PV) technology. The advantage of BIPV system is its multi-functionality; they fulfil the functions of a building envelope with the added benefit of generating power by replacing the traditional roofing and façade materials with PV that generate power. In this thesis, different types of PV cells and modules have been described in detail with their efficiencies and usage trends in the last decade. The different BIPV products for roof and façade are discussed in detail giving several examples. The electricity generation potential of BIPV in selected countries is compared with their actual electricity consumption. Further, the avoided greenhouse gas (GHG) emissions associated with electricity generation from traditional sources and transportation and distribution (T&D) losses are calculated. The results illustrate huge savings in GHGs. In BIPV different types of façade and backsheets are used. In this thesis, selected backsheets and façade were characterized in terms of their surface structure identification using infrared spectroscopy (FTIR-ATR), scanning electron microscopy with energy dispersive X-ray (SEM-EDX) and physical characterization using surface energy measurements. By using FTIR-ATR, surface polymeric materials were identified and with SEM-EDX, identification of the surface elements was possible. Surface energy measurements were useful in finding the adhesives and knowing the surface energies of the various backsheets and façade. The strength of adhesion between the facade and backsheets was studied using peel test. Four different types of adhesives were used to study the fracture pattern and peel tests values to identify the most suitable adhesive. It was found out that pretreatment increased the adhesive strength significantly.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Cold pitched roofs, with their form of construction situating insulation on a horizontal ceiling, are intrinsically vulnerable to condensation. This study reports the results derived from using a simulation package (Heat, Air and Moisture modelling tool, or HAM-Tools) to investigate the risk of condensation in cold pitched roofs in housing fitted with a vapour-permeable underlay (VPU) of known characteristics. In order to visualize the effect of the VPUs on moisture transfer, several scenarios were modelled, and compared with the results from a conventional bituminous felt with high resistance (200 MNs/g, Sd = 40 m). The results indicate that ventilation is essential in the roof to reduce condensation. However, a sensitivity analysis proved that reducing the overall tightness of the ceiling and using lower-resistance VPUs would help in controlling condensation formation in the roof. To a large extent, the proposed characteristic performance of the VPU as predicted by manufacturers and some researchers may only be realistic if gaps in the ceiling are sealed completely during construction, which may be practically difficult given current construction practice.