443 resultados para Booster seats.


Relevância:

20.00% 20.00%

Publicador:

Resumo:

In elections voters have generally four options: to abstain, to cast a blank vote, to cast a null vote, or to vote for a candidate or party. This last option is a positive expression of support, while the other three options reflect lack of interest, or dissatisfaction with the parties or the political system. However only votes for parties or candidates are taken into account in the apportionment method. In particular the number of seats allocated to parties remains constant even if the number of non votes (i.e. blank votes, null votes or abstention) is very large. This paper proposes to treat the non votes as a party in the apportionment method and to leave empty the corresponding seats. These empty seats are referred to as "ghost seats". How this would affect the decision-making is quantified in terms of power indices. We apply this proposal to a case study:the regional Parliament of the Basque Autonomous Community (Spain) from 1980 till 2012.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new kind of shock capturing method is developed. Before applying the high order accurate traditional scheme which is called as base scheme in this paper the fluid parameters are preconditioned in order to control the group velocity. The newly constructed scheme is high order accurate, simple, has high resolution of the shock, and less computer time consumed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Due to their high risk of developing severe Bordetella pertussis (Bp) infections, it is recommended to immunize preterm infants at their chronological age. However, little is known about the persistence of their specific immune responses, especially of the cellular responses recognized to play a role in protection. We compared here the cellular immune responses to two major antigens of Bp between three groups of one year-old children born prematurely, who received for their primary vaccination respectively the whole cell vaccine Tetracoq(®) (TC), the acellular vaccine Tetravac(®) (TV), or the acellular vaccine Infanrix-hexa(®) (IR). Whereas most children had still detectable IFN-γ responses at one year of age, they were lower in the IR-vaccinated children compared to the two other groups. In contrast, both the TV- and the IR-vaccinated children displayed higher Th2-type immune responses, resulting in higher antigen-specific IFN-γ/IL-5 ratios in TC- than in TV- or IR-vaccinated children. The IFN-γ/IL-5 ratio of mitogen-induced cytokines was also lower in IR- compared to TC- or TV-vaccinated children. No major differences in the immune responses were noted after the booster compared to the pre-booster responses for each vaccine. The IR-vaccinated children had a persistently low specific Th1-type immune response associated with high specific Th2-type immune responses, resulting in lower antigen-specific IFN-γ/IL-5 ratios compared to the two other groups. We conclude that antigen-specific cellular immune responses persisted in one year-old children born prematurely and vaccinated during infancy at their chronological age, that a booster dose did not significantly boost the cellular immune responses, and that the Th1/Th2 balance of the immune responses is modulated by the different vaccines.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In 2010 the Australian Government established the Higher Education Participation and Partnerships programme – a funding agenda to promote programmes that respond to the underrepresentation in higher education of people from what is often denoted low socioeconomic status (SES) backgrounds. Many government-funded programmes and projects have since emerged that respond to the problem of low SES underrepresentation, based on partnerships between higher education providers and other organisations. The arguments made in this paper draw on one such project: a mentoring programme implemented from 2011 to 2013 that targeted the aspirations of Year 9 regional secondary students. We discuss data and documentation that provide insights into the conception and design of the mentoring programme, and the strategies used to evaluate it, in order to discuss how funding and policy contexts influences the possible solutions that might be implemented in response to the underrepresentation in higher education of people from low SES backgrounds.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Esse artigo apresenta o uso do programa de ajuste sazonal X-13ARIMA-SEATS desenvolvido e mantido por US Census Bureau. O programa é mundialmente utilizado por órgãos de estatística e, em alguns lugares, ainda em sua versão anterior. O ajuste sazonal é implementado no software R e aplicado na série temporal do índice de produção industrial geral do Brasil. As ferramentas disponíveis pelo programa permitiram aprimorar o ajuste automático e diagnosticá-lo de forma adequada. Apresenta-se também uma rotina para executar o ajuste sazonal em mais de uma série simultaneamente, uma vez que, geralmente, as instituições que realizam tal procedimento, não o fazem para apenas uma série temporal.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Low voltage solar panels increase the reliability of solar panels due to reduction of in series associations the configurations of photovoltaic cells. The low voltage generation requires DCDC converters devices with high efficiency, enabling raise and regulate the output voltage. This study analyzes the performance of a photovoltaic panel of Solarex, MSX model 77, configured to generate an open circuit voltage of 10.5 V, with load voltage of 8.5 V, with short circuit current of 9 A and a power of 77 W. The solar panel was assembled in the isolated photovoltaic system configuration, with and without energy storage as an interface with a DCDC converter, Booster topology. The converter was designed and fabricated using SMD (Surface Mounted Devices) technology IC (integrated circuit) that regulates its output voltage at 14.2 V, with an efficiency of 87% and providing the load a maximum power of 20.88 W. The system was installed and instrumented for measurement and acquisition of the following data: luminosities, average global radiation (data of INPE Instituto Nacional de Pesquisas Espaciais), solar panel and environment temperatures, solar panel and DC-DC converter output voltages, panel, inverter, and battery charge output currents. The photovoltaic system was initially tested in the laboratory (simulating its functioning in ideal conditions of operation) and then subjected to testing in real field conditions. The panel inclination angle was set at 5.5°, consistent with the latitude of Natal city. Factors such as climatic conditions (simultaneous variations of temperature, solar luminosities and ra diation on the panel), values of load resistance, lower limit of the maximum power required by the load (20.88 W) were predominant factors that panel does not operate with energy efficiency levels greater than 5 to 6%. The average converter efficiency designed in the field test reached 95%

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The end magnets of the IFUSP race-track microtron booster, second stage of the electron accelerator under construction at the Linear Accelerator Laboratory, are presented. They deflect, focus and return the beam to the accelerating section. Details about the project are discussed, Poisson code was used to give the final geometry of the end magnets. The end magnets incorporate auxiliary pole pieces (clamps) which create a reverse fringe field region that avoids the beam vertical defocusing and reduces the horizontal displacement produced by extended fringe fields (EFF). The small gap height used for the clamps provided reverse field distributions with fringe fields of short extensions, avoiding the traditional use of inactive clamps. Measurements and calculations concerning particle trajectories and reverse field distribution are presented. The floating wire technique, employing an original procedure to register orbits, was used to corroborate the calculated beam trajectories and represents a good experimental option in the lack of the accelerator beam. The experimental results showed agreement of about 0.1% with the calculations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We will present measurements and calculations related to the antisymmetric perturbations, and comparisons with the symmetric ones, of the IFUSP race-track microtron booster accelerator end magnets. These perturbations were measured in planes situated at +/-12 mm of the middle plane, in a gap height of 4 cm, for a field distribution of about 0.1 T. The measurements were done in 1170 points, separated by a distance of 8 mm, using an automated system with a +/-1.5 mu T differential Hall probe. The race-track microtron booster is the second stage of the 30.0 MeV electron accelerator under construction at the Linear Accelerator Laboratory in which the required uniformity for the magnetic field is of about 10(-3). The method of correction employed to homogenize the IFUSP race-track microtron booster accelerator magnets assures uniformity of 10(-5) in an average field of 0.1 T, over an area of 700 cm(2). This method uses the principle of attaching to the pole pieces correction coils produced by etching techniques, with copper leads shaped like the isofield lines of the normal component of the magnetic field measured. The ideal planes, in which these measurements are done, are calculated and depend on the behavior of the magnetic field perturbations: symmetric or antisymmetric with reference to the middle plane of the magnet gap. These calculations are presented in this work and show that for antisymmetric perturbations there is no ideal plane for the correction of the magnetic field; for the symmetric one, these planes are at +/-60% of the half gap height, from the middle plane. So this method of correction is not feasible for antisymmetric perturbations, as will be shown. Besides, the correction of the symmetric portion of the field distribution does not influence the antisymmetric one, which almost does not change, and corroborates the theoretical predictions. We found antisymmetric perturbations of small intensity only in one of the two end magnets. However, they are not detected at +/- 1 mm of the middle plane and will not damage the electron beam.