987 resultados para Bone level
Resumo:
Purpose: The implant-abutment connection (microgap) influences the pen-implant bone morphology. However, it is unclear if different microgap configurations additionally modify bone reactions. This preliminary study aimed to radiographically monitor pen-implant bone levels in two different microgap configurations during 3 months of nonsubmerged healing. Materials and Methods: Six dogs received two implants with internal Morse taper connection (INT group) on one side of the mandible and two implants with external-hex connection (EXT group) on the other side. One implant on each side was positioned at bone level (equicrestal); the second implant was inserted 1.5 mm below the bone crest (subcrestal). Healing abutments were attached directly after implant insertion, and the implants were maintained for 3 months without prosthetic loading. At implant placement and 1, 2, and 3 months, standardized radiographs were taken to monitor pen-implant bone levels. Results: All implants osseointegrated. A total bone loss of 0.48 +/- 0.66 mm was measured in the equicrestal INT group, 0.69 +/- 0.43 mm in the equicrestal EXT group, 0.79 +/- 0.93 mm in the subcrestal INT group, and 1.56 +/- 0.53 mm in the subcrestal EXT group (P>.05, paired t tests). Within the four groups, bone loss over time became significantly greater in the EXT groups than in the INT groups. The greatest bone loss was noted in the subcrestal EXT group. Conclusion: Within the limits of this animal study, it seems that even without prosthetic loading, different microgap configurations exhibit different patterns of bone loss during nonsubmerged healing. Subcrestal positioning of an external butt joint microgap may lead to faster radiographic bone loss. Int J Prosthodont 2011;24:445-452.
Resumo:
Background: The aim of the present study was to evaluate clinical and radiographic changes that occur around dental implants inserted in different levels in relation to crestal bone under different restoration protocols.Methods: Thirty-six implants were inserted in the edentulous mandible of six mongrel dogs. Each implant was assigned to an experimental group according to the distance from the top of the implant to the crestal bone: Bone Level (at crestal bone level), Minus 1 (1 mm below crestal bone), or Minus 2 (2 mm below crestal bone). Each hemimandible was submitted to a restoration protocol: conventional (prosthesis was installed 120 days after implant placement, including 30 days with healing cap) or immediate (prosthesis was installed 24 hours after implant placement). Fixed partial prostheses were installed bilaterally in the same day. After 90 days, clinical and radiographic parameters were evaluated.Results: As long as the implants were inserted in more apical positions, the first bone-to-implant contact (fBIC) was positioned more apically (P<0.05). However, the apical positioning of the implants did not influence the ridge loss or the position of the soft tissue margin (PSTM) (P>0.05). In addition, in immediately restored sites, the PSTM was located significantly more coronally than that in conventionally restored sites (P=0.02).Conclusions: Despite the more apical positioning of the fBIC, the height of the peri-implant soft tissues and ridge was not jeopardized. Moreover, the immediate restoration protocol was beneficial to the maintenance of the PSTM. Further studies are suggested to evaluate the significance of these results in longer healing periods.
Resumo:
Objectives: The aim of the present study was to evaluate histometric changes around dental implants inserted at different levels in relation to the crestal bone, under different loading conditions.Material and methods: Thirty-six implants were inserted in the edentulous mandible of six mongrel dogs. Each implant was assigned to an experimental group according to the distance from the top of the implant to the crestal bone: Bone Level (at the crestal bone level), Minus 1 (1 mm below the crestal bone) or Minus 2 group (2 mm below the crestal bone). Each hemimandible was submitted to a loading protocol: conventional or immediate restoration. After 90 days, the animals were killed. Specimens were processed, and measurements were performed concerning the length of soft and hard peri-implant tissues. Data were analyzed using ANOVA and Student's t test (alpha=5%).Results: Among conventionally restored sites, the distance from the most coronal position of soft tissue margin (PSTM) and first bone-implant contact (fBIC) was greater for Minus 2 than for Bone Level and Minus 1 sites (P=0.03), but significant differences were not observed among immediately restored sites. Differences among groups were not observed concerning the PSTM, and the distance from the implant-abutment junction to fBIC. Greater amounts of lateral bone loss were observed for conventionally than for immediately restored sites (P=0.006).Conclusions: These findings suggest that the apical positioning of the top of the implant may not jeopardize the position of soft peri-implant tissues, and that immediate restoration can be beneficial to minimize lateral bone loss. Further studies are suggested to evaluate the clinical significance of these results in longer healing periods.
Resumo:
Purpose: The aim of this study was to evaluate the possibility of obtaining guided bone regeneration using a poly-tetrafluoroethylene (PTFE) nonporous barrier for 2 endosseous implants, partially inserted in tibiae of rabbits.Materials and Methods: Histologic characteristics of the interface between titanium implants (one group with titanium plasma-coated implants and the other group with acid-treated surfaces) and of the regenerated bone were also studied. Twenty screw-vent implants were placed in tibiae of 5 male New Zealand rabbits, 2 at the right side and 2 at the left side, protruding 3 mm from the bone level, to create a horizontal bone defect. At the experimental group the implants were with a PTFE nonporous barrier, whereas no barriers were used in contralateral implants. Animals were sacrificed 3 months after surgery and biopsy specimens were evaluated histologically and histomorphometrically under light microscopy. Student's t test was used for statistical analysis.Results: The histologic measurements showed a mean gain in bone height of 2.15 and 2.42 mm for the barrier group and 1.95 and 0.43 mm for the control group, for the titanium plasma-spray and acid-treated implant surfaces, respectively.Conclusion: The results of the investigation revealed that the placement of implants protruding 3 nun from crestal bone defects may result in vertical bone augmentation using a nonporous PTFE barrier. (Implant Dent 2009;18:182-191)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES
Resumo:
AIM: To explore the biomechanical effects of the different implantation bone levels of Morse taper implants, employing a finite element analysis (FEA). METHODS: Dental implants (TitamaxCM) with 4x13 mm and 4x11 mm, and their respective abutments with 3.5 mm height, simulating a screwed premolar metal-ceramic crown, had their design performed using the software AnsysWorkbench 10.0. They were positioned in bone blocks, covered by 2.5 mm thickness of mucosa. The cortical bone was designed with 1.5 mm thickness and the trabecular bone completed the bone block. Four groups were formed: group 11CBL (11 mm implant length on cortical bone level), group 11TBL (11 mm implant length on trabecular bone level), group 13CBL (13mm implant length on cortical bone level) and group 13TBL (13 mm implant length on trabecular bone level). Oblique 200 N loads were applied. Von Mises equivalent stresses in cortical and trabecular bones were evaluated with the same design program. RESULTS: The results were shown qualitatively and quantitatively by standard scales for each type of bone. By the results obtained, it can be suggested that positioning the implant completely in trabecular bone brings harm with respect to the generated stresses. Its implantation in the cortical bone has advantages with respect to better anchoring and locking, reflecting a better dissipation of the stresses along the implant/bone interfaces. In addition, the search for anchoring the implant in its apical region in cortical bone is of great value to improve stabilization and consequently better stress distribution. CONCLUSIONS: The implant position slightly below the bone in relation to the bone crest brings advantages as the best long-term predictability with respect to the expected neck bone loss.
Resumo:
BACKGROUND: There are still limited data on the outcomes of regenerative periodontal surgery using a combination of an enamel matrix protein derivative (EMD) and autogenous bone (AB). AIM: To evaluate the healing of deep intrabony defects treated with either a combination EMD+AB or EMD alone. MATERIALS AND METHODS: Forty patients with advanced chronic periodontitis, with one deep intrabony defect, were randomly treated with either EMD+AB (test) or EMD (control). Clinical assessments were performed at baseline and at 1 year after treatment. The primary outcome variable was relative attachment level (RAL). RESULTS: Healing was uneventful in all patients. The test sites showed a reduction in the mean probing pocket depth (PPD) of 5.6 +/- 0.9 mm (p<0.001), a gain in the mean RAL of 4.2 +/- 1.1 mm (p<0.001) and a gain in the mean probing bone level (PBL) of 3.9 +/- 1.0 mm (p<0.001). The control group displayed a mean PPD reduction of 4.6 +/- 0.4 mm (p<0.001), a mean RAL gain of 3.4 +/- 0.8 mm (p<0.001) and a mean PBL gain of 2.8 +/- 0.8 mm (p<0.001). RAL gains of > or =4 mm were measured in 90% of the test defects and in 55% of the controls. PBL gains of > or =4 mm were obtained in 85% of the test defects and in 25% of the control ones. The test treatment resulted in statistically higher PPD reductions, RAL gains and PBL gains compared with the control (p<0.01). CONCLUSIONS: Within their limits, the present results indicate that: (i) at 1 year after surgery, both therapies resulted in statistically significant clinical improvements compared with baseline and (ii) although the combination of EMD+AB resulted in statistically significant higher soft and hard tissue improvements compared with treatment with EMD, the clinical relevance of this finding is unclear.
Resumo:
The concept of platform switching has been introduced to implant dentistry based on observations of reduced peri-implant bone loss. However, randomized clinical trials are still lacking. This study aimed to test the hypothesis that platform switching has a positive impact on crestal bone-level changes.
Resumo:
A minimal marginal bone loss around implants during early healing has been considered acceptable. However, the preservation of the marginal bone is related to soft tissue stability and esthetics. Implant designs and surfaces were evaluated to determine their impact on the behavior of the crestal bone. The purpose of this study is to evaluate histologic marginal bone level changes around early loaded, chemically modified, sandblasted acid-etched-surfaced implants with a machined collar (MC) or no MC (NMC).
Resumo:
AIM: The aim of this study was to compare the clinical outcomes after 2 years with bone level implants placed to restore a single missing teeth that needed simultaneous augmentation and were treated with a transmucosal or submerged approach. METHODS: This study analyzed a subset of patients included in an ongoing prospective multicenter randomized clinical trial (RCT) involving12 centers where patients were to be followed-up to 5 years after loading. Of the 120 implants that were placed in the original study, and randomly assigned to submerged or non-submerged healing, 52 needed simultaneous augmentation (28 women patients and 24 men patients, between 23 and 78 years of age). Twenty-seven of them received implants with submerged healing (AuS), while in 25 patients the implants were inserted with a non-submerged protocol (AuNS). At the 2-year follow-up visit, radiographic crestal bone level changes were recorded as well as soft tissue parameters included Pocket probing depth (PPD), bleeding on probing (BoP) and clinical attachment level (CAL) at teeth adjacent to the implant site. RESULTS: After 2 years a small amount of bone resorption was found in both groups (0.37 ± 0.49 mm in the AuS group and 0.54 ± 0.76 in the AuNS group; P < 0.001). There was no statistically significant difference between AuS Group and AuNS group for PPD (2.5 vs. 2.4 mm), BOP (BOP + sites: 8.8% vs. 11.5%) and CAL (2.8 vs. 2.4 mm) at the 2-year follow-up visit. CONCLUSIONS: When a single implant is placed in the aesthetic zone in conjunction with bone augmentation for a moderate peri-implant defect, submerged and transmucosal healing determine similar outcome, hence there is no need to submerge an implant in this given clinical situation.
Resumo:
BACKGROUND: It has been shown that different implant designs and different vertical implant positions have an influence on crestal bone levels. The aim of the present study was to evaluate radiographic crestal bone changes around experimental dental implants with non-matching implant-abutment diameters placed submucosally or transmucosally at three different levels relative to the alveolar crest. METHODS: Sixty two-piece dental implants with non-matching implant-abutment diameters were placed in edentulous spaces bilaterally in five foxhounds. The implants were placed submucosally or transmucosally in the left or the right side of the mandible. Within each side, six implants were randomly placed at three distinct levels relative to the alveolar crest. After 12 weeks, 60 crowns were cemented. Radiographs were obtained from all implant sites following implant placement, after crown insertion, and monthly for 6 months after loading. RESULTS: Radiographic analysis revealed very little bone loss and a slight increase in bone level for implants placed at the level of the crest or 1 mm above. The greatest bone loss occurred at implants placed 1 mm below the bone crest. No clinically significant differences regarding marginal bone loss and the level of the bone-to-implant contact were detected between implants with a submucosal or a transmucosal healing. CONCLUSIONS: Implants with non-matching implant-abutment diameters demonstrated some bone loss; however, it was a small amount. There was no clinically significant difference between submucosal and transmucosal approaches.
Resumo:
BACKGROUND: Early implant placement is one of the treatment options in postextraction sites in the anterior maxilla. Implant placement is performed after a soft tissue healing period of 4 to 8 weeks. Implant placement is combined with a simultaneous guided bone regeneration (GBR) procedure to rebuild esthetic facial hard and soft tissue contours. METHODS: In this prospective case-series study, 20 consecutive patients treated with an implant-borne single crown were prospectively followed for 12 months. Clinical, radiologic, and esthetic parameters were recorded to assess treatment outcomes. RESULTS: At the 12-month examination, all 20 implants were successfully integrated, demonstrating ankylotic stability and healthy peri-implant soft tissues as documented by standard parameters. The esthetic outcomes assessed by a pink esthetic score (PES) and a white esthetic score (WES) demonstrated pleasing results overall. The WES values were slightly superior to the PES values. The periapical radiographs showed minimal crestal bone loss around the used bone level implants, with mean bone loss of 0.18 mm at 12 months. Only one implant showed >0.5 mm bone loss, combined with minor mucosal recession of 0.5 to 1.0 mm. CONCLUSIONS: This prospective case series study evaluating the concept of early implant placement demonstrated successful tissue integration for all 20 implants. The short-term follow-up of 12 months revealed pleasing esthetic outcomes overall, as assessed by objective parameters. The risk for mucosal recession was low; only one patient showed minor recession of the facial mucosa. These encouraging results need to be confirmed with 3- and 5-year follow-up examinations.
Bone response to loaded implants with non-matching implant-abutment diameters in the canine mandible
Resumo:
BACKGROUND: One way to evaluate various implant restorations is to measure the amount of bone change that occurs at the crestal bone. The objective of this study was to histologically evaluate the alveolar bone change around a bone-level, non-matching implant-abutment diameter configuration that incorporated a horizontal offset and a Morse taper internal connection. METHODS: The study design included extraction of all mandibular premolars and first molars in five canines. After 3 months, 12 dental implants were placed at three levels in each dog: even with the alveolar crest, 1 mm above the alveolar crest, and 1 mm below the alveolar crest. The implants were submerged on one side of the mandible. On the other side, healing abutments were exposed to the oral cavity (non-submerged). Gold crowns were attached 2 months after implant placement. The dogs were sacrificed 6 months postloading, and specimens were processed for histologic and histometric analyses. RESULTS: Evaluation of the specimens indicated that the marginal bone remained near the top of the implants under submerged and non-submerged conditions. The amount of bone change for submerged implants placed even with, 1 mm below, and 1 mm above the alveolar crest was -0.34, -1.29, and 0.04 mm, respectively (negative values indicate bone loss). For non-submerged implants, the respective values were -0.38, -1.13, and 0.19 mm. For submerged and non-submerged implants, there were significant differences in the amount of bone change among the three groups (P <0.05). The percentage of bone-to-implant contact for submerged implants was 73.3%, 71.8%, and 71.5%. For non-submerged implants, the respective numbers were 73.2%, 74.5%, and 76%. No significant differences occurred with regard to the percentage of bone contact. CONCLUSIONS: Minimal histologic bone loss occurred when dental implants with non-matching implant-abutment diameters were placed at the bone crest and were loaded for 6 months in the canine. The bone loss was significantly less (five- to six-fold) than that reported for bone-level implants with matching implant-abutment diameters (butt-joint connections).
Resumo:
PURPOSE The purpose of this study was to document the long-term outcome of Brånemark implants installed in augmented maxillary bone and to identify parameters that are associated with peri-implant bone level. MATERIAL AND METHODS Patients of a periodontal practice who had been referred to a maxillofacial surgeon for iliac crest bone grafting in the atrophic maxilla were retrospectively recruited. Five months following grafting, they received 7-8 turned Brånemark implants. Following submerged healing of another 5 months, implants were uncovered and restorative procedures for fixed rehabilitation were initiated 2-3 months thereafter. The primary outcome variable was bone level defined as the distance from the implant-abutment interface to the first visible bone-to-implant contact. Secondary outcome variables included plaque index, bleeding index, probing depth, and levels of 40 species in subgingival plaque samples as identified by means of checkerboard DNA-DNA hybridization. RESULTS Nine out of 16 patients (eight females, one male; mean age 59) with 71 implants agreed to come in for evaluation after on average 9 years (SD 4; range 3-13) of function. One implant was deemed mobile at the time of inspection. Clinical conditions were acceptable with 11% of the implants showing pockets ≥ 5 mm. Periodontopathogens were encountered frequently and in high numbers. Clinical parameters and bacterial levels were highly patient dependent. The mean bone level was 2.30 mm (SD 1.53; range 0.00-6.95), with 23% of the implants demonstrating advanced resorption (bone level > 3 mm). Regression analysis showed a significant association of the patient (p < .001) and plaque index (p = .007) with bone level. CONCLUSIONS The long-term outcome of Brånemark implants installed in iliac crest-augmented maxillary bone is acceptable; however, advanced peri-implant bone loss is rather common and indicative of graft resorption. This phenomenon is patient dependent and seems also associated with oral hygiene.
Resumo:
BACKGROUND Limited data exist on the longitudinal crestal bone changes around teeth compared with implants in partially edentulous patients. This study sought to compare the 10-year radiographic crestal bone changes (bone level [BL]) around teeth and implants in periodontally compromised (PCPs) and periodontally healthy (PHPs) patients. METHODS A total of 120 patients were evaluated for the radiographic crestal BL around dental implants and adjacent teeth at time of implant crown insertion and at the 10-year follow-up. Sixty patients had a previous history of periodontitis (PCPs), and the remaining 60 were PHPs. In each category (PCP and PHP), two different implant systems were used. The mean BL change at the implant and at the adjacent tooth at the interproximal area was calculated by subtracting the radiographic crestal BL at the time of crown cementation from the radiographic crestal BL at the 10-year follow-up. RESULTS At 10 years after therapy, the survival rate ranged from 80% to 95% for subgroups for implants, whereas it was 100% for the adjacent teeth. In all eight different patient categories evaluated, teeth demonstrated a significantly more stable radiographic BL compared with adjacent dental implants (teeth BL, 0.44 ± 0.23 mm; implant BL, 2.28 ± 0.72 mm; P <0.05). Radiographic BL changes around teeth seemed not to be influenced by the presence or absence of advanced bone loss (≥3 mm) at the adjacent implants. CONCLUSIONS Natural teeth yielded better long-term results with respect to survival rate and marginal BL changes compared with dental implants. Moreover, these findings also extend to teeth with an initial reduced periodontal attachment level, provided adequate periodontal treatment and maintenance are performed. As a consequence, the decision of tooth extraction attributable to periodontal reasons in favor of a dental implant should be carefully considered in partially edentulous patients.