931 resultados para Blood Pressure Determination
Resumo:
Measurement of the blood pressure by the physician remains an essential step in the evaluation of cardiovascular risk. Ambulatory measurement and self-measurement of blood pressure are ways of counteracting the "white coat" effect which is the rise in blood pressure many patients experience in the presence of doctors. Thus, it is possible to define the cardiovascular risk of hypertension and identify the patients with the greatest chance of benefiting from antihypertensive therapy. However, it must be realised that normotensive subjects during their everyday activities and becoming hypertensive in the doctor's surgery, may become hypertensive with time, irrespective of the means used to measure blood pressure. These patients should be followed up regularly even if the decision to treat has been postponed.
Resumo:
In this retrospective analysis, we assessed the usefulness of ambulatory blood pressure monitoring in the evaluation of elderly hypertensive patients. Thirty-eight untreated and 31 treated hypertensives aged 70 years or more had a systolic blood pressure greater than or equal to 160 mmHg and/or a diastolic blood pressure greater than or equal to 95 mmHg in the clinic. All 69 patients underwent blood pressure monitoring during their customary daily activities using a portable semi-automatic blood pressure recorder (Remier M2000). The mean of all blood pressures obtained with this device was taken as the ambulatory recorded blood pressure. Recorded blood pressures were greater than or equal to 160 mmHg systolic and greater than or equal to 90 mmHg diastolic in 17 untreated and 17 treated patients. In these patients, the introduction of antihypertensive therapy, or its modification, markedly reduced blood pressure during a 4-8 month follow-up. A further 21 untreated and 14 treated patients had recorded blood pressures of less than 160/90 mmHg. The treatment status of these patients was left unchanged for 4-8 months of follow-up. Nevertheless, office blood pressure in these groups, with no change in treatment, decreased significantly during the observation period. At the last visit to the outpatient clinic, there was no significant difference in blood pressure between the four subgroups of patients. Thus, ambulatory blood pressure monitoring appears to be useful in the elderly hypertensive patient in detecting those patients whose blood pressure is elevated only in the clinic. Blood pressure profiles obtained outside the clinic may therefore be useful in making therapeutic decisions in the aged hypertensive.
Resumo:
OBJECTIVE: Cuff inflation at the arm is known to cause an instantaneous rise in blood pressure, which might be due to the discomfort of the procedure and might interfere with the precision of the blood pressure measurement. In this study, we compared the reactive rise in blood pressure induced by cuff inflation when the cuff was placed at the upper arm level and at the wrist. PARTICIPANTS AND METHODS: The reactive rise in systolic and diastolic blood pressure to cuff inflation was measured in 34 normotensive participants and 34 hypertensive patients. Each participant was equipped with two cuffs, one around the right upper arm (OMRON HEM-CR19, 22-32 cm) and one around the right wrist (OMRON HEM-CS 19, 17-22 cm; Omron Health Care Europe BV, Hoofddorp, The Netherlands). The cuffs were inflated in a double random order (maximal cuff pressure and position of the cuff) with two maximal cuff pressures: 180 and 240 mmHg. The cuffs were linked to an oscillometric device (OMRON HEM 907; Omron Health Care). Simultaneously, blood pressure was measured continuously at the middle finger of the left hand using photoplethysmography. Three measurements were made at each level of blood pressure at the arm and at the wrist, and the sequence of measurements was randomized. RESULTS: In normotensive participants, no significant difference was observed in the reactive rise in blood pressure when the cuff was inflated either at the arm or at the wrist irrespective of the level of cuff inflation. Inflating a cuff at the arm, however, induced a significantly greater rise in blood pressure than inflating it at the wrist in hypertensive participants for both systolic and diastolic pressures (P<0.01), and at both levels of cuff inflation. The blood pressure response to cuff inflation was independent of baseline blood pressure. CONCLUSIONS: The results show that in hypertensive patients, cuff inflation at the wrist produces a smaller reactive rise in blood pressure. The difference between the arm and the wrist is independent of the patient's level of blood pressure.
Resumo:
OBJECTIVE: To assess the association between microalbuminuria with ambulatory blood pressure monitoring in normotensive individuals with insulin-dependent diabetes mellitus. METHODS: Thirty-seven patients underwent determination of the rate of urinary excretion of albumin through radioimmunoassay and ambulatory blood pressure monitoring. Their mean age was 26.5±6.7 years, and the mean duration of their disease was 8 (1-34) years. Microalbuminuria was defined as urinary excretion of albumin > or = 20 and <200µg/min in at least 2 out of 3 urine samples. RESULTS: Nine (24.3%) patients were microalbuminuric. Ambulatory blood pressure monitoring in the microalbuminuric patients had higher mean pressure values, mainly the systolic pressure, during sleep as compared with that in the normoalbuminuric patients (120.1±8.3 vs 110.8±7.1 mmHg; p=0.007). The pressure load was higher in the microalbuminuric individuals, mainly the systolic pressure load during wakefulness [6.3 (2.9-45.9) vs 1.6 (0-16%); p=0.001]. This was the variable that better correlated with the urinary excretion of albumin (rS=0.61; p<0.001). Systolic pressure load >50% and diastolic pressure load > 30% during sleep was associated with microalbuminuria (p=0.008). The pressure drop during sleep did not differ between the groups. CONCLUSION: Microalbuminuric normotensive insulin-dependent diabetic patients show greater mean pressure value and pressure load during ambulatory blood pressure monitoring, and these variables correlate with urinary excretion of albumin.
Resumo:
OBJECTIVE: To reach a consensus on the clinical use of ambulatory blood pressure monitoring (ABPM). METHODS: A task force on the clinical use of ABPM wrote this overview in preparation for the Seventh International Consensus Conference (23-25 September 1999, Leuven, Belgium). This article was amended to account for opinions aired at the conference and to reflect the common ground reached in the discussions. POINTS OF CONSENSUS: The Riva Rocci/Korotkoff technique, although it is prone to error, is easy and cheap to perform and remains worldwide the standard procedure for measuring blood pressure. ABPM should be performed only with properly validated devices as an accessory to conventional measurement of blood pressure. Ambulatory recording of blood pressure requires considerable investment in equipment and training and its use for screening purposes cannot be recommended. ABPM is most useful for identifying patients with white-coat hypertension (WCH), also known as isolated clinic hypertension, which is arbitrarily defined as a clinic blood pressure of more than 140 mmHg systolic or 90 mmHg diastolic in a patient with daytime ambulatory blood pressure below 135 mmHg systolic and 85 mmHg diastolic. Some experts consider a daytime blood pressure below 130 mmHg systolic and 80 mmHg diastolic optimal. Whether WCH predisposes subjects to sustained hypertension remains debated. However, outcome is better correlated to the ambulatory blood pressure than it is to the conventional blood pressure. Antihypertensive drugs lower the clinic blood pressure in patients with WCH but not the ambulatory blood pressure, and also do not improve prognosis. Nevertheless, WCH should not be left unattended. If no previous cardiovascular complications are present, treatment could be limited to follow-up and hygienic measures, which should also account for risk factors other than hypertension. ABPM is superior to conventional measurement of blood pressure not only for selecting patients for antihypertensive drug treatment but also for assessing the effects both of non-pharmacological and of pharmacological therapy. The ambulatory blood pressure should be reduced by treatment to below the thresholds applied for diagnosing sustained hypertension. ABPM makes the diagnosis and treatment of nocturnal hypertension possible and is especially indicated for patients with borderline hypertension, the elderly, pregnant women, patients with treatment-resistant hypertension and patients with symptoms suggestive of hypotension. In centres with sufficient financial resources, ABPM could become part of the routine assessment of patients with clinic hypertension. For patients with WCH, it should be repeated at annual or 6-monthly intervals. Variation of blood pressure throughout the day can be monitored only by ABPM, but several advantages of the latter technique can also be obtained by self-measurement of blood pressure, a less expensive method that is probably better suited to primary practice and use in developing countries. CONCLUSIONS: ABPM or equivalent methods for tracing the white-coat effect should become part of the routine diagnostic and therapeutic procedures applied to treated and untreated patients with elevated clinic blood pressures. Results of long-term outcome trials should better establish the advantage of further integrating ABPM as an accessory to conventional sphygmomanometry into the routine care of hypertensive patients and should provide more definite information on the long-term cost-effectiveness. Because such trials are not likely to be funded by the pharmaceutical industry, governments and health insurance companies should take responsibility in this regard.
Resumo:
OBJECTIVE: To assess the post-ischemic skin blood flow response after withdrawal of antihypertensive therapy in hypertensive patients with normal blood pressure during treatment. DESIGN AND METHODS: Twenty hypertensive patients (group A) with a normal clinic blood pressure (<140/ 90 mmHg) receiving antihypertensive treatment (any monotherapy; one pill per day for at least 6 months) had their treatment discontinued. Before medication withdrawal and 2, 4, 12 and 24 weeks thereafter, the following measurements were made: clinic blood pressure, home blood pressure (three times per week, morning and evening) and skin blood flow response to a 5 min forearm arterial occlusion (using laser Doppler flowmetry). The patients were asked to perform an ambulatory blood pressure recording at any time if home blood pressure was > or =160/95 mmHg on two consecutive days, and treatment was initiated again, after determination of the skin hyperemic response, if daytime ambulatory blood pressure was > or =140/90 mmHg. The same studies were performed in 20 additional hypertensive individuals in whom antihypertensive treatment was not withdrawn (group B). The allocation of patients to groups A and B was random. RESULTS: The data fom 18 patients in group A who adhered strictly to the procedure were available for analysis. Seven of them had to start treatment again within the first 4 weeks of follow-up; four additional patients started treatment again during the next 8 weeks (group A1). The seven other patients remained untreated (group A2). The skin hyperemic response decreased significantly in patients in group A1 and returned to baseline values at the end of the study, when there were again receiving antihypertensive treatment. In patients in group A2 a significant attenuation of the hyperemic response was also observed. This impaired response was present even at the end of the 6 month follow-up, at which time the patients were still untreated but exhibited a significantly greater blood pressure than before drug discontinuation. The hyperemic response of patients who did not stop treatment (group B) did not change during the course of the study. CONCLUSIONS: Our findings show a decrease in the postischemic skin blood flow response after withdrawal of antihypertensive treatment in hypertensive patients. This impaired response may be due to the development of endothelial dysfunction, vascular remodeling, or both, and might contribute to the return of blood pressure to hypertensive values after withdrawal of antihypertensive therapy.
Resumo:
A new, orally active angiotensin converting enzyme (ACE) inhibitor, CGS 14824A, was evaluated in 12 healthy male volunteers. Two groups each of 6 volunteers were given 5 or 10 mg once daily p.o. for 8 days. Four hours after the first and the last morning doses, plasma angiotensin II, aldosterone and plasma converting enzyme activity had fallen, while blood angiotensin I and plasma renin activity had risen. Throughout the study, more than 90% inhibition of ACE was found immediately before giving either the 5 or 10 mg dose and 50% blockade was still present 72 h following the last dose. Based on the determination of ACE, there was no evidence of drug accumulation. No significant change in blood pressure or heart rate was observed during the course of the study. CGS 14824A was an effective, orally active, long-lasting and well tolerated converting enzyme inhibitor.
Resumo:
Self-measurement of blood pressure (SMBP) is increasingly used to assess blood pressure outside the medical setting. A prerequisite for the wide use of SMBP is the availability of validated devices providing reliable readings when they are handled by patients. This is the case today with a number of fully automated oscillometric apparatuses. A major advantage of SMBP is the great number of readings, which is linked with high reproducibility. Given these advantages, one of the major indications for SMBP is the need for evaluation of antihypertensive treatment, either for individual patients in everyday practice or in clinical trials intended to characterize the effects of blood-pressure-lowering medications. In fact, SMBP is particularly helpful for evaluating resistant hypertension and detecting white-coat effect in patients exhibiting high office blood pressure under antihypertensive therapy. SMBP might also motivate the patient and improve his or her adherence to long-term treatment. Moreover, SMBP can be used as a sensitive technique for evaluating the effect of antihypertensive drugs in clinical trials; it increases the power of comparative trials, allowing one to study fewer patients or to detect smaller differences in blood pressure than would be possible with the office measurement. Therefore, SMBP can be regarded as a valuable technique for the follow-up of treated patients as well as for the assessment of antihypertensive drugs in clinical trials.
Resumo:
Exercise brachial blood pressure ( BP) predicts mortality, but because of wave reflection, central ( ascending aortic) pressure differs from brachial pressure. Exercise central BP may be clinically important, and a noninvasive means to derive it would be useful. The purpose of this study was to test the validity of a noninvasive technique to derive exercise central BP. Ascending aortic pressure waveforms were recorded using a micromanometer-tipped 6F Millar catheter in 30 patients (56 +/- 9 years; 21 men) undergoing diagnostic coronary angiography. Simultaneous recordings of the derived central pressure waveform were acquired using servocontrolled radial tonometry at rest and during supine cycling. Pulse wave analysis of the direct and derived pressure signals was performed offline (SphygmoCor 7.01). From rest to exercise, mean arterial pressure and heart rate were increased by 20 +/- 10 mm Hg and 15 +/- 7 bpm, respectively, and central systolic BP ranged from 77 to 229 mm Hg. There was good agreement and high correlation between invasive and noninvasive techniques with a mean difference (+/- SD) for central systolic BP of -1.3 +/- 3.2 mm Hg at rest and -4.7 +/- 3.3 mm Hg at peak exercise ( for both r=0.995; P < 0.001). Conversely, systolic BP was significantly higher peripherally than centrally at rest (155 +/- 33 versus 138 +/- 32mm Hg; mean difference, -16.3 +/- 9.4mm Hg) and during exercise (180 +/- 34 versus 164 +/- 33 mm Hg; mean difference, -15.5 +/- 10.4 mm Hg; for both P < 0.001). True myocardial afterload is not reliably estimated by peripheral systolic BP. Radial tonometry and pulse wave analysis is an accurate technique for the noninvasive determination of central BP at rest and during exercise.
Resumo:
Assessment of central blood pressure (BP) has grown substantially over recent years because evidence has shown that central BP is more relevant to cardiovascular outcomes than peripheral BP. Thus, different classes of antihypertensive drugs have different effects on central BP despite similar reductions in brachial BP. The aim of this study was to investigate the effect of nebivolol, a β-blocker with vasodilator properties, on the biochemical and hemodynamic parameters of hypertensive patients. Experimental single cohort study conducted in the outpatient clinic of a university hospital. Twenty-six patients were recruited. All of them underwent biochemical and hemodynamic evaluation (BP, heart rate (HR), central BP and augmentation index) before and after 3 months of using nebivolol. 88.5% of the patients were male; their mean age was 49.7 ± 9.3 years and most of them were overweight (29.6 ± 3.1 kg/m2) with large abdominal waist (102.1 ± 7.2 cm). There were significant decreases in peripheral systolic BP (P = 0.0020), diastolic BP (P = 0.0049), HR (P < 0.0001) and central BP (129.9 ± 12.3 versus 122.3 ± 10.3 mmHg; P = 0.0083) after treatment, in comparison with the baseline values. There was no statistical difference in the augmentation index or in the biochemical parameters, from before to after the treatment. Nebivolol use seems to be associated with significant reduction of central BP in stage I hypertensive patients, in addition to reductions in brachial systolic and diastolic BP.
Resumo:
Taurine is a sulfur-containing amino acid that exerts protective effects on vascular function and structure in several models of cardiovascular diseases through its antioxidant and anti-inflammatory properties. Early protein malnutrition reprograms the cardiovascular system and is linked to hypertension in adulthood. This study assessed the effects of taurine supplementation in vascular alterations induced by protein restriction in post-weaning rats. Weaned male Wistar rats were fed normal- (12%, NP) or low-protein (6%, LP) diets for 90 days. Half of the NP and LP rats concomitantly received 2.5% taurine supplementation in the drinking water (NPT and LPT, respectively). LP rats showed elevated systolic, diastolic and mean arterial blood pressure versus NP rats; taurine supplementation partially prevented this increase. There was a reduced relaxation response to acetylcholine in isolated thoracic aortic rings from the LP group that was reversed by superoxide dismutase (SOD) or apocynin incubation. Protein expression of p47phox NADPH oxidase subunit was enhanced, whereas extracellular (EC)-SOD and endothelial nitric oxide synthase phosphorylation at Ser 1177 (p-eNOS) were reduced in aortas from LP rats. Furthermore, ROS production was enhanced while acetylcholine-induced NO release was reduced in aortas from the LP group. Taurine supplementation improved the relaxation response to acetylcholine and eNOS-derived NO production, increased EC-SOD and p-eNOS protein expression, as well as reduced ROS generation and p47phox expression in the aortas from LPT rats. LP rats showed an increased aortic wall/lumen ratio and taurine prevented this remodeling through a reduction in wall media thickness. Our data indicate a protective role of taurine supplementation on the high blood pressure, endothelial dysfunction and vascular remodeling induced by post-weaning protein restriction. The beneficial vascular effect of taurine was associated with restoration of vascular redox homeostasis and improvement of NO bioavailability.