945 resultados para Attitude alignment
Resumo:
The value of a seasonal forecasting system based on phases of the Southern Oscillation was estimated for a representative dryland wheat grower in the vicinity of Goondiwindi. In particular the effects on this estimate of risk attitude and planting conditions were examined. A recursive stochastic programming approach was used to identify the grower's utility-maximising action set in the event of each of the climate patterns over the period 1894-1991 recurring In the imminent season. The approach was repeated with and without use of the forecasts. The choices examined were, at planting, nitrogen application rate and cultivar and, later in the season, choices of proceeding with or abandoning each wheat activity, The value of the forecasting system was estimated as the maximum amount the grower could afford to pay for its use without expected utility being lowered relative to its non use.
Resumo:
Research on outcomes from psychiatric disorders has highlighted the importance of expressed emotion (EE), but its cost-effective measurement remains a challenge. This article describes development of the Family Attitude Scale (FAS), a 30-item instrument that can be completed by any informant. Its psychometric characteristics are reported in parents of undergraduate students and in 70 families with a schizophrenic member. The total FAS had high internal consistency in all samples, and reports of angry behaviour in FAS items showed acceptable inter-rater agreement. The FAS was associated with the reported anger, anger expression and anxiety of respondents. Substantial associations between the parents' FAS and the anger and anger expression of students was also observed. Parents of schizophrenic patients had higher FAS scores than parents of students, and the FAS was higher if disorder duration was longer or patient functioning was poorer. Hostility, high criticism and low warmth on the Camberwell Family Interview (CFI) were associated with a more negative FAS. The highest FAS in the family was a good predictor of a highly critical environment on the CFI. The FAS is a reliable and valid indicator of relationship stress and expressed anger that has wide applicability. (C) 1997 Elsevier Science Ireland Ltd.
Resumo:
Objective: The aim of this study was to test the effectiveness of various attitude-behavior theories in explaining alcohol use among young adults. The theory of reasoned action (TRA), the theory of planned behavior and an extension of the TRA that incorporates past behavior were compared by the method of maximum-likelihood estimation, as implemented in LISREL for Windows 8.12. Method: Respondents consisted of 122 university students (82 female) who were questioned about their attitudes, subjective norms, perceived behavioral control, past behavior and intentions relating to drinking behavior. Students received course credit for their participation in the research. Results: Overall, the results suggest that the extension of the theory of reasoned action which incorporates past behavior provides the best fit to the data. For these young adults, their intentions to drink alcohol were predicted by their past behavior as well as their perceptions of what important others think they should do (subjective norm). Conclusions: The main conclusions drawn from the research concern the importance of focusing on normative influences and past behavior in explaining young adult alcohol use. Issues regarding the relative merit of various alternative models and the need for greater clarity in the measure of attitudes are also discussed.
Resumo:
Objective: To evaluate influences of vitrification and warming of metaphase II (MII) mouse oocytes on survival, spindle dynamics. spindle morphology, and chromatin alignment on metaphase plates. Design: Experimental animal Study. Setting: University animal laboratory. Animal(s): Eight-week-old B6D2F1 mice. Intervention(s): Denuded MII oocytes were used fresh (control), exposed to vitrification/warming solutions (Sol Expos), or vitrified and warmed (Vitr). Main Outcome Measure(s): Oocyte recovery and survival after warming and the influence of solution exposure and cryopreservation on spindle dynamics and chromatin alignment. Result(s): Cryopreservation of two or 10 oocytes per straw resulted in recovery (100% +/- 0% and 95% +/- 4%, respectively; mean SE) and survival (95% 2% and 98% 2%, respectively). Immediately after warming (Vitr), significantly fewer oocytes assessed with immunocytochemistry contained spindles, compared with control and Sol Expos. When oocytes were placed into a 3 degrees 7C environment for 2 hours after exposure or warming, the ability to recognize spindles by immunocytochemistry was not significantly different between groups. Using live-cell time-lapse imaging with LC-Polscope, similar time-dependent spindle formation dynamics were observed. At 2 hours after collection or treatment, spindle morphology and length were not significantly different between the groups, nor was the incidence of aberrant alignment of chromatin on metaphase plates. Conclusion(s): Immediately after warming of vitrified MII oocytes, beta-tubulin is depolymerized and chromatin remains condensed on the metaphase plate. Within a 2-hour period, beta-tubulin repolymerizes, forming morphologically normal metaphase spindles with properly aligned chromatin.
Resumo:
Objective. To determine if knee alignment measures differ between African Americans and Caucasians without radiographic knee osteoarthritis (rOA). Methods. A single knee was randomly selected from 175 participants in the Johnston County Osteoarthritis Project without rOA in either knee. Anatomic axis, condylar, tibia] plateau, and condylar plateau angles were measured by I radiologist; means were compared and adjusted for age and body mass index (BMI). Results. There were no significant differences in knee alignment measurements between Caucasians and African Americans among men or women. Conclusion. Observed differences in knee rOA occurrence between African Americans and Caucasians are not explained by differences in static knee alignment. (First Release July 15 2009; J Rheumatol 2009;36:1987-90; doi: 10.3899/jrheum.081294)
Resumo:
Purpose: Children`s postural alignment undergoes many adjustments due to the changes in body proportions during the stages of growth. The objective of this study was to quantitatively characterize and analyze spinal postural standards in 7- and 8-year-old children to verify which of the differences found were correlated to age and sex. Methods: Two hundred thirty public school students (Amparo, Sao Paulo, Brazil) aged 7 to 8 years were divided into groups according to postural alignment, which were further subdivided by sex and age, for comparison. Digital photos of upright Subjects were analyzed to evaluate posture. Lumbar and thoracic curvature, pelvic inclination, head posture, and lateral spine deviation were measured using CorelDraw (Ottawa, Canada) software guidelines and bone landmarks. Descriptive statistics and analysis of variance data analysis were utilized to verify differences among the groups. This was a cross-sectional, descriptive study. Results: Mean values for the variables analyzed were calculated. For lumbar lordosis, 7-year-old boys showed 38.49 degrees +/- 15.32 degrees in comparison to all other groups (42.29 degrees +/- 7.13 degrees). For thoracic kyphosis, the 7-year-old children presented 28.07 degrees +/- 7.73 degrees. and the 8-year-olds 30.32 degrees +/- 7.73 degrees. Pelvic inclination presented a mean value of 15.82 degrees +/- 5.46 degrees and single lateral spine deviation mean value of 3.48 degrees +/- 2.12 degrees. Conclusion: For the sample studied, differences based on sex and age were found for some of the body segments analyzed. The values found in this study may contribute to improved physiotherapeutic treatment when associated with other aspects of the clinical assessment and symptomatology. (J Manipulative Physiol Ther 2009;32: 154-159)
Resumo:
Objective. To investigate the processing induced particle alignment on fracture behavior of four multiphase dental ceramics (one porcelain, two glass-ceramics and a glass-infiltrated-alumina composite). Methods. Disks (empty set12mm x 1.1 mm-thick) and bars (3 mm x 4 mm x 20 mm) of each material were processed according to manufacturer instructions, machined and polished. Fracture toughness (K(IC)) was determined by the indentation strength method using 3-point bending and biaxial flexure fixtures for the fracture of bars and disks, respectively. Microstructural and fractographic analyses were performed with scanning electron microscopy, energy dispersive spectroscopy and X-ray diffraction. Results. The isotropic microstructure of the porcelain and the leucite-based glass-ceramic resulted in similar fracture toughness values regardless of the specimen geometry. On the other hand, materials containing second-phase particles with high aspect ratio (lithium disilicate glass-ceramic and glass-infiltrated-alumina composite) showed lower fracture toughness for disk specimens compared to bars. For the lithium disilicate glass-ceramic disks, it was demonstrated that the occurrence of particle alignment during the heat-pressing procedure resulted in an unfavorable pattern that created weak microstructural paths during the biaxial test. For the glass-infiltrated-alumina composite, the microstructural analysis showed that the large alumina platelets tended to align their large surfaces perpendicularly to the direction of particle deposition during slip casting of green preforms. Significance. The fracture toughness of dental ceramics with anisotropic microstructure should be determined by means of biaxial testing, since it results in lower values. (C) 2009 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
Resumo:
Introduction: The purpose of this retrospective study was to compare the long-term stability of maxillary incisor alignment in patients treated with and without rapid maxillary expansion (RME). Methods: The sample comprised 48 subjects with Class I and Class II malocclusions, treated without extractions with fixed edgewise appliances, divided into 2 groups according to the treatment protocol: group 1 comprised 25 patients (15 girls, 10 boys) at a mean initial age of 13.53 years (SD, 1.63), who had RME during orthodontic treatment. Group 2 comprised 23 patients (13 girls, 10 boys) at a mean initial age of 13.36 years (SD, 1.81 years), treated with fixed appliances without RME. Maxillary dental cast measurements were obtained at the pretreatment, posttreatment, and long-term posttreatment stages. Variables assessed were the irregularity index and maxillary arch dimensions. Intergroup comparisons were made with independent t tests. Results: Greater transverse increases were found during treatment in the group treated with RME. However, during the long-term posttreatment period, no significant difference was observed in the amount of incisor crowding relapse between the groups. Conclusions: RME did not influence long-term maxillary anterior alignment stability. (Am J Orthod Dentofacial Orthop 2010; 137: 164. e1-164.e6)
Resumo:
(E)-N-Hexadecyl-4-[2-(4-octadecyloxynaphthyl) ethenyl] quinolinium bromide, which has a wide-bodied chromophore and terminal n-alkyl groups, adopts a U-shape when spread at the air-water interface but a stretched conformation when compressed to ca. 35 mN m(-1). The high-pressure phase has a narrow stability range prior to collapse but may be extended from 40 to 60 mN m(-1) by co-spreading the dye in a 1 : 1 ratio with docosanoic acid. The mixed Langmuir-Blodgett (LB) film has a monolayer thickness of 4.6 +/- 0.2 nm which decreases to 2.5 +/- 0.1 nm layer(-1) in the bulk, the reduction arising from an interdigitating layer arrangement, both top and bottom. It is the first example of LB-Lego(R) and, in addition, represents the only fully interdigitating structure with non-centrosymmetrically aligned chromophores. They are tilted 38 degrees from the substrate normal. The second-harmonic intensity increases quadratically with the number of layers, i.e. as I-(N)(2 omega) = (I(1)N2)-N-2 omega, with a second-order susceptibility of chi ((2))(zzz) = 30 pm V-1 at 1064 nm for refractive indices of n(omega) = 1.55 and n(2 omega) = 1.73, d = 2.5 nm layer(-1) and phi = 38 degrees. Angle resolved X-ray photoelectron spectra (XPS) of these films provide no evidence of the bromide counterion, which suggests that it is replaced by OH 2 or HCO3-, which occur naturally in the aqueous subphase, or C21H43COO- from the co-deposited fatty acid. This probably applies to all cationic dyes deposited by the LB technique.
Resumo:
We present a novel maximum-likelihood-based algorithm for estimating the distribution of alignment scores from the scores of unrelated sequences in a database search. Using a new method for measuring the accuracy of p-values, we show that our maximum-likelihood-based algorithm is more accurate than existing regression-based and lookup table methods. We explore a more sophisticated way of modeling and estimating the score distributions (using a two-component mixture model and expectation maximization), but conclude that this does not improve significantly over simply ignoring scores with small E-values during estimation. Finally, we measure the classification accuracy of p-values estimated in different ways and observe that inaccurate p-values can, somewhat paradoxically, lead to higher classification accuracy. We explain this paradox and argue that statistical accuracy, not classification accuracy, should be the primary criterion in comparisons of similarity search methods that return p-values that adjust for target sequence length.
Resumo:
Two experiments were conducted to test predictions derived from social identity/self-categorization theory concerning the role of group norms in attitude-behavior consistency. In Experiment 1, 160 students who could be classified as having a more or less certain target attitude were exposed to attitude congruent versus incongruent normative support from a relevant reference group (own university) under conditions of low versus high group salience. Experiment 2 was very similar in design and methodology (N=180), but a different correlate of attitude accessibility was used (an experimental manipulation of repeated expression), the target attitude was changed, and the reference group was gender. Across the 2 experiments there was consistent support for the hypothesis that participants would behave more in accordance with their attitudes when they received normative support for, rather than opposition to, their original attitude from a relevant reference group (i.e., their ingroup, not an outgroup). There was slightly weaker support for the second hypothesis that this effect would be stronger under high-than low-salience conditions. The third hypothesis (see Fazio, 1986), that attitude certainty and repeated expression of the attitude would strengthen attitude-behavior consistency, was well supported, as was the expectation that accessibility effects would be independent of reference group norm effects on attitude-behavior consistency.
Resumo:
Three studies support the vicarious dissonance hypothesis that individuals change their attitudes when witnessing members of important groups engage in inconsistent behavior. Study 1, in which participants observed an actor in an induced-compliance paradigm, documented that students who identified with their college supported an issue more after hearing an ingroup member make a counterattitudinal speech in favor of that issue. In Study 2, vicarious dissonance occurred even when participants did not hear a speech, and attitude change was highest when the speaker was known to disagree with the issue. Study 3 showed that speaker choice and aversive consequences moderated vicarious dissonance, and demonstrated that vicarious discomfort-the discomfort observers imagine feeling if in an actor's place-was attenuated after participants expressed their revised attitudes.
Resumo:
Battery separators based on electrospun membranes of poly(vinylidene fluoride) (PVDF) have been prepared in order to study the effect of fiber alignment on the performance and characteristics of the membrane. The prepared membranes show an average fiber diameter of 272 nm and a degree of porosity of 87 %. The gel polymer electrolytes are prepared by soaking the membranes in the electrolyte solution. The alignment of the fibers improves the mechanical properties for the electrospun membranes. Further, the microstructure of the membrane also plays an important role in the ionic conductivity, being higher for the random electrospun membrane due to the lower tortuosity value. Independently of the microstructure, both membranes show good electrochemical stability up to 5.0 V versus Li/Li+. These results show that electrospun membranes based on PVDF are appropriate for battery separators in lithium-ion battery applications, the random membranes showing a better overall performance.
Resumo:
Given the dynamic nature of cardiac function, correct temporal alignment of pre-operative models and intraoperative images is crucial for augmented reality in cardiac image-guided interventions. As such, the current study focuses on the development of an image-based strategy for temporal alignment of multimodal cardiac imaging sequences, such as cine Magnetic Resonance Imaging (MRI) or 3D Ultrasound (US). First, we derive a robust, modality-independent signal from the image sequences, estimated by computing the normalized crosscorrelation between each frame in the temporal sequence and the end-diastolic frame. This signal is a resembler for the left-ventricle (LV) volume curve over time, whose variation indicates di erent temporal landmarks of the cardiac cycle. We then perform the temporal alignment of these surrogate signals derived from MRI and US sequences of the same patient through Dynamic Time Warping (DTW), allowing to synchronize both sequences. The proposed framework was evaluated in 98 patients, which have undergone both 3D+t MRI and US scans. The end-systolic frame could be accurately estimated as the minimum of the image-derived surrogate signal, presenting a relative error of 1:6 1:9% and 4:0 4:2% for the MRI and US sequences, respectively, thus supporting its association with key temporal instants of the cardiac cycle. The use of DTW reduces the desynchronization of the cardiac events in MRI and US sequences, allowing to temporally align multimodal cardiac imaging sequences. Overall, a generic, fast and accurate method for temporal synchronization of MRI and US sequences of the same patient was introduced. This approach could be straightforwardly used for the correct temporal alignment of pre-operative MRI information and intra-operative US images.