933 resultados para Atmospheric electrical discharges
Resumo:
The solar wind modulates the flux of galactic cosmic rays impinging on Earth inversely with solar activity. Cosmic ray ionisation is the major source of air’s electrical conductivity over the oceans and well above the continents. Differential solar modulation of the cosmic ray energy spectrum modifies the cosmic ray ionisation at different latitudes,varying the total atmospheric columnar conductance. This redistributes current flow in the global atmospheric electrical circuit, including the local vertical current density and the related surface potential gradient. Surface vertical current density and potential gradient measurements made independently at Lerwick Observatory,Shetland,from 1978 to 1985 are compared with modelled changes in cosmic ray ionisation arising from solar activity changes. Both the lower troposphere atmospheric electricity quantities are significantly increased at cosmic ray maximum(solar minimum),with a proportional change greater than that of the cosmic ray change.
Resumo:
Current flowing in the global atmospheric electrical circuit (AEC) substantially decreased during the twentieth century. Fair-weather potential gradient (PG) observations in Scotland and Shetland show a previously unreported annual decline from 1920 to 1980, when the measurements ceased. A 25% reduction in PG occurred in Scotland 1920–50, with the maximum decline during the winter months. This is quantitatively explained by a decrease in cosmic rays (CR) increasing the thunderstorm-electrosphere coupling resistance, reducing the ionospheric potential VI. Independent measurements of VI also suggest a reduction of 27% from 1920–50. The secular decrease will influence fair weather atmospheric electrical parameters, including ion concentrations and aerosol electrification. Between 1920–50, the PG showed a negative correlation with global temperature, despite the positive correlation found recently between surface temperature and VI. The 1980s stabilisation in VI may arise from compensation of the continuing CR-induced decline by increases in global temperature and convective electrification.
Resumo:
Measurements of the electrical characteristics of the atmosphere above the surface have been made for over 200 years, from a variety of different platforms, including kites, balloons, rockets and aircraft. From these measurements, a great deal of information about the electrical characteristics of the atmosphere has been gained, assisting our understanding of the global atmospheric electric circuit, thunderstorm electrification and lightning generation mechanisms, discovery of transient luminous events above thunderstorms, and many other electrical phenomena. This paper surveys the history of atmospheric electrical measurements aloft, from the earliest manned balloon ascents to current day observations with free balloons and aircraft. Measurements of atmospheric electrical parameters in a range of meteorological conditions are described, including clear air conditions, polluted conditions, non-thunderstorm clouds, and thunderstorm clouds, spanning a range of atmospheric conditions, from fair weather, to the most electrically active.
Resumo:
Lord Kelvin (William Thomson) made important contributions to the study of atmospheric elec- tricity during a brief but productive period from 1859–1861. By 1859 Kelvin had recognised the need for “incessant recording” of atmospheric electrical parameters, and responded by inventing both the water dropper equaliser for measuring the atmospheric potential gradient (PG), and photographic data logging. The water dropper equaliser was widely adopted internationally and is still in use today. Following theoretical consid- erations of electric field distortion by local topography, Kelvin developed a portable electrometer, using it to investigate the PG on the Scottish island of Arran. During these environmental measurements, Kelvin may have unwittingly detected atmospheric PG changes during solar activity in August / September 1859 associated with the “Carrington event”, which is interesting in the context of his later statements that solar magnetic influ- ence on the Earth was impossible. Kelvin’s atmospheric electricity work presents an early representative study in quantitative environmental physics, through the application of mathematical principles to an environmental problem, the design and construction of bespoke instrumentation for real world measurements and recognising the limitations of the original theoretical view revealed by experimental work
Resumo:
Technical problems have hampered the study of sleep in teleosts. The electrical discharges of Gymnotus carapo L. (Gymnotidae: Gymnotiformes) were monitored to evaluate their ease and reliability as parameters to study sleep. The discharges were detected by electrodes immersed in a glass aquarium and were recorded on a conventional polygraph. G. carapo showed conspicuous signs of behavioral sleep. During these periods, opercular beat rates were counted, electric discharges recorded, and the sharp discharge increase (SDI) of the orienting reflex was investigated. All 20 animals monitored maintained electrical discharges during behavioral sleep. The discharge frequencies during sleep (50.3 ± 10.4 Hz) were not significantly different from those observed when the fish was awake and inactive (57.2 ± 12.1 Hz) (Wilcoxon matched-pairs signed-ranks test, P>0.05). However, the SDI, which was prevalent in the awake fish, was not observed during periods of behavioral sleep. Additional observations showed that the species had cannibalistic habits. When presented with electrical discharges from a conspecific, the sleeping fish showed an initial decrease or pause in discharge frequency, while the awake fish did not have this response. We conclude that the electrical discharges of G. carapo were not conspicuous indicators of behavioral sleep. Discharges may have been maintained during sleep for sensory purposes, i.e., conspecific detection and avoidance of cannibalistic attacks.
Resumo:
This paper aims to develop a web application for viewing Atmospheric Electrical Discharge, plotting marks on a map, using as base data provided by SIMEPAR. The developed system uses techniques and tools which enable the creation of Web system without requiring the use of plugins or external software, running on virtually all web browsers and platforms. This tool aims to aid meteorologists monitor agile discharges and help society at large to prevent accidents caused by this phenomenon of nature
Resumo:
This dissertation represents experimental and numerical investigations of combustion initiation trigged by electrical-discharge-induced plasma within lean and dilute methane air mixture. This research topic is of interest due to its potential to further promote the understanding and prediction of spark ignition quality in high efficiency gasoline engines, which operate with lean and dilute fuel-air mixture. It is specified in this dissertation that the plasma to flame transition is the key process during the spark ignition event, yet it is also the most complicated and least understood procedure. Therefore the investigation is focused on the overlapped periods when plasma and flame both exists in the system. Experimental study is divided into two parts. Experiments in Part I focuses on the flame kernel resulting from the electrical discharge. A number of external factors are found to affect the growth of the flame kernel, resulting in complex correlations between discharge and flame kernel. Heat loss from the flame kernel to code ambient is found to be a dominant factor that quenches the flame kernel. Another experimental focus is on the plasma channel. Electrical discharges into gases induce intense and highly transient plasma. Detailed observation of the size and contents of the discharge-induced plasma channel is performed. Given the complex correlation and the multi-discipline physical/chemical processes involved in the plasma-flame transition, the modeling principle is taken to reproduce detailed transitions numerically with minimum analytical assumptions. Detailed measurement obtained from experimental work facilitates the more accurate description of initial reaction conditions. The novel and unique spark source considering both energy and species deposition is defined in a justified manner, which is the key feature of this Ignition by Plasma (IBP) model. The results of numerical simulation are intuitive and the potential of numerical simulation to better resolve the complex spark ignition mechanism is presented. Meanwhile, imperfections of the IBP model and numerical simulation have been specified and will address future attentions.
Resumo:
Introdução Os potenciais evocados auditivos de média latência (PEAML) reflectem actividade neuronal mesencefáfica, mais precisamente da região tálamo-cortical, dos colículos inferiores e da formação reticular. A epilepsia é caracterizada por variadas manifestações anormais do comportamento cerebral, sendo descrita como uma perturbação da função cerebral, tendo origem numa descarga anómala de um conjunto ou da totalidade dos neurónios do córtice cerebral. Está documentado, que as descargas eléctricas provocadas pelas crises de epilepsia podem levar a perdas neuronais, pelo que poderão existir alterações nos PEAML. Objectivos A escassa existência de literatura sobre o tema e a não investigação na população portuguesa, originou a execução deste estudo, que teve como objectivo investigar e documentar a existência de alterações ou achados nos componentes neuronais de média latência (PEAML), numa amostra de portugueses com epilepsia. Metodologia Foram realizados PEAML a um grupo de controlo (GC) composto por 16 participantes e a um grupo clínico (GCL) de 8 participantes com epilepsia, sendo analisados os componentes Na, Pa e Na-Pa quanto à sua morfologia, latência e amplitude. Resultados A morfologia das ondas e a presença de epilepsia não estão associados, no entanto, contrariamente ao GC que evidenciou latências e amplitudes de Na, Pa e Na-Pa dentro dos padrões de normalidade, a alteração ou ausência de respostas por parte do GCL é significativa na totalidade das medidas investigadas. Conclusão Em epilepsias generalizadas e focais do lobo temporal os PEAML evidenciam alterações, tal achado poderá ser eventualmente justificado pela propagação ascendente e descendente da informação auditiva se encontrar comprometida, devido a sequelas deixadas pelas crises epilépticas nas vias auditivas mesencefálicas. As alterações verificadas foram uma morfologia anómala das ondas ou ausência das mesmas.
Resumo:
Induction motors are widely used in industry, and they are generally considered very reliable. They often have a critical role in industrial processes, and their failure can lead to significant losses as a result of shutdown times. Typical failures of induction motors can be classified into stator, rotor, and bearing failures. One of the reasons for a bearing damage and eventually a bearing failure is bearing currents. Bearing currents in induction motors can be divided into two main categories; classical bearing currents and inverter-induced bearing currents. A bearing damage caused by bearing currents results, for instance, from electrical discharges that take place through the lubricant film between the raceways of the inner and the outer ring and the rolling elements of a bearing. This phenomenon can be considered similar to the one of electrical discharge machining, where material is removed by a series of rapidly recurring electrical arcing discharges between an electrode and a workpiece. This thesis concentrates on bearing currents with a special reference to bearing current detection in induction motors. A bearing current detection method based on radio frequency impulse reception and detection is studied. The thesis describes how a motor can work as a “spark gap” transmitter and discusses a discharge in a bearing as a source of radio frequency impulse. It is shown that a discharge, occurring due to bearing currents, can be detected at a distance of several meters from the motor. The issues of interference, detection, and location techniques are discussed. The applicability of the method is shown with a series of measurements with a specially constructed test motor and an unmodified frequency-converter-driven motor. The radio frequency method studied provides a nonintrusive method to detect harmful bearing currents in the drive system. If bearing current mitigation techniques are applied, their effectiveness can be immediately verified with the proposed method. The method also gives a tool to estimate the harmfulness of the bearing currents by making it possible to detect and locate individual discharges inside the bearings of electric motors.
Resumo:
Teoriaosassa tutkittiin mäskin muodostumista oluentuotantoprosessissa, ligniiniä ja sen pilkkoutumista hapetuksella, eri kehittyneitä hapetusmenetelmiä ja hapetuksella saatavia potentiaalisia pääkomponentteja. Kehittyneissä hapetusmenetelmissä keskityttiin pääasiassa pulssitettuun koronapurkaukseen perustuvaan PCD-menetelmään (Pulsed Corona Discharge). Tutkittavana pääkomponenttina toimi glyoksyylihappo. Työn kokeellisessa osassa tutkittiin mäskistä erotetun ligniinin pilkkoutumista PCD-hapetuksella. Tässä menetelmässä hapetus perustuu sähköpurkauksen aikana syntyvien hydroksyyliradikaalien ja otsonin muodostumiseen, jotka voivat toimia hapettimina. Kokeissa käytettiin oluentuotannosta saatua mäskiä, josta ligniiniä liuotettiin natriumhydroksidi-vesi-liuoksen avulla uuttamalla.. Tämän jälkeen liuosta käsiteltiin PCD laitteistossa. PCD-käsiteltyä tuotetta analysoitiin mittaamalla ligniinin ja aldehydien pitoisuudet siitä spektrofotometrin avulla. Työn tarkoituksena on tutkia PCD hapetusmenetelmän soveltuvuutta mäskin sisältämän ligniinin muokkaamiseen siten, että siitä syntyvää tuotetta voitaisiin käyttää jossakin muussa sovelluksessa, kuten esimerkiksi lääkkeiden raaka-aineena lääketeollisuudessa. PCD hapetusmenetelmä on koronasähköpurkauksiin perustuva laite, jota käytetään pääasiassa vedenpuhdistuksessa hajoittamaan haitallisia orgaanisia yhdisteitä. Tämän työn perusteella ligniiniä hajosi, aldehydejä muodostui ja hapetusnäytteiden pH laski hapetusajan kasvaessa. Tämä viittasi vahvasti glyoksyylihapon muodostumiseen PCD-laitteistossa.
Resumo:
This article is a systematic review of the available literature on the benefits that cognitive behavioral therapy (CBT) offers patients with implanted cardioverter defibrillators (ICDs) and confirms its effectiveness. After receiving the device, some patients fear that it will malfunction, or they remain in a constant state of tension due to sudden electrical discharges and develop symptoms of anxiety and depression. A search with the key words “anxiety”, “depression”, “implantable cardioverter”, “cognitive behavioral therapy” and “psychotherapy” was carried out. The search was conducted in early January 2013. Sources for the search were ISI Web of Knowledge, PubMed, and PsycINFO. A total of 224 articles were retrieved: 155 from PubMed, 69 from ISI Web of Knowledge. Of these, 16 were written in a foreign language and 47 were duplicates, leaving 161 references for analysis of the abstracts. A total of 19 articles were eliminated after analysis of the abstracts, 13 were eliminated after full-text reading, and 11 articles were selected for the review. The collection of articles for literature review covered studies conducted over a period of 13 years (1998-2011), and, according to methodological design, there were 1 cross-sectional study, 1 prospective observational study, 2 clinical trials, 4 case-control studies, and 3 case studies. The criterion used for selection of the 11 articles was the effectiveness of the intervention of CBT to decrease anxiety and depression in patients with ICD, expressed as a ratio. The research indicated that CBT has been effective in the treatment of ICD patients with depressive and anxiety symptoms. Research also showed that young women represented a risk group, for which further study is needed. Because the number of references on this theme was small, further studies should be carried out.
Resumo:
Laser-induced plasma generated from a silver target under partial vacuum conditions using the fundamental output of nanosecond duration from a pulsed Nd:yttrium aluminum garnet laser is studied using a Langmuir probe. The time of flight measurements show a clear twin peak distribution in the temporal profile of electron emission. The first peak has almost the same duration as the laser pulse while the second lasts for several microseconds. The prompt electrons are energetic enough ('60 eV) to ionize the ambient gas molecules or atoms. The use of prompt electron pulses as sources for electron impact excitation is demonstrated by taking nitrogen, carbon dioxide, and argon as ambient gases.
Resumo:
The global atmospheric electrical circuit sustains a vertical current density between the ionosphere and the Earth's surface, the existence of which is well-established from measurements made in fair-weather conditions. In overcast, but non-thunderstorm, non-precipitating conditions, the current travels through the cloud present, despite cloud layers having low electrical conductivity. For extensive layer clouds, this leads to space charge at the upper and lower cloud boundaries. Using a combination of atmospheric electricity and solar radiation measurements at three UK sites, vertical current measurements have been categorised into clear, broken, and overcast cloud conditions. This approach shows that the vertical “fair weather” current is maintained despite the presence of cloud. In fully overcast conditions with thick cloud, the vertical current is reduced compared to thin cloud overcast conditions, associated with the cloud's resistance contributions. Contribution of cloud to the columnar resistance depends both on cloud thickness, and the cloud's height.
Resumo:
Abstract Foggy air and clear air have appreciably different electrical conductivities. The conductivity gradient at horizontal droplet boundaries causes droplet charging, as a result of vertical current flow in the global atmospheric electrical circuit. The charging is poorly known, as both the current flow through atmospheric water droplet layers and the air conductivity are poorly characterised experimentally. Surface measurements during three days of continuous fog using new instrument techniques show that a shallow (of order 100 m deep) fog layer still permits the vertical conduction current to pass. Further, the conductivity in the fog is estimated to be approximately 20% lower than in clear air. Assuming a fog transition thickness of one metre, this implies a vertical conductivity gradient of order 10 fS m−2 at the boundary. The actual vertical conductivity gradient at a cloud boundary would probably be greater, due to the presence of larger droplets in clouds compared to fog, and cleaner, more conductive clear air aloft.
Resumo:
Historical smoke concentrations at monthly resolution for the early twentieth century are found for Kew Observatory, London, using the atmospheric electricity proxy technique. Smoke particles modify the electrical properties of urban air: an increase in smoke concentration reduces air's electrical conductivity and increases the Potential Gradient (PG). Calibrated PG data are available from Kew since 1898, and air conductivity was measured routinely between 1909 and 1979 using the technique developed by C.T.R. Wilson. Automated smoke observations at the same site overlap with the atmospheric electrical measurements from 1921, providing an absolute calibration to smoke concentration. This shows that the late nineteenth century winter smoke concentrations at Kew were approximately 100 times greater than contemporary winter smoke concentrations. Following smoke emission regulations reducing the smoke concentration, the electrical parameters of the urban air did not change dramatically. This is suggested to be due to a composition change, with an increase in the abundance of small aerosol compensating for the decrease in smoke. (c) 2006 Elsevier Ltd. All rights reserved.