56 resultados para Americium.


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Nuclear masses are an important quantity to study nuclear structure since they reflect the sum of all nucleonic interactions. Many experimental possibilities exist to precisely measure masses, out of which the Penning trap is the tool to reach the highest precision. Moreover, absolute mass measurements can be performed using carbon, the atomic-mass standard, as a reference. The new double-Penning trap mass spectrometer TRIGA-TRAP has been installed and commissioned within this thesis work, which is the very first experimental setup of this kind located at a nuclear reactor. New technical developments have been carried out such as a reliable non-resonant laser ablation ion source for the production of carbon cluster ions and are still continued, like a non-destructive ion detection technique for single-ion measurements. Neutron-rich fission products will be available by the reactor that are important for nuclear astrophysics, especially the r-process. Prior to the on-line coupling to the reactor, TRIGA-TRAP already performed off-line mass measurements on stable and long-lived isotopes and will continue this program. The main focus within this thesis was on certain rare-earth nuclides in the well-established region of deformation around N~90. Another field of interest are mass measurements on actinoids to test mass models and to provide direct links to the mass standard. Within this thesis, the mass of 241-Am could be measured directly for the first time.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Vertical fluxes of 239+240Pu and 241Am and temporal changes in their inventories in the northwestern Mediterranean Sea have been examined through high-resolution water column sampling coupled with direct measurements of the vertical flux of particle-bound transuranics using time-series sediment traps. Water column profiles of both radionuclides showed well-defined sub-surface maxima (2391240Pu between 100-400 m; 241Am at 100-200 m and 800 m), the depths of which are a result of the different biogeochemical scavenging behavior of the two radionuclides. Comparison of deep water column (0-2,000 m) transuranic inventories with those derived from earlier measurements demonstrate that the total 2391240Pu inventory had not substantially changed between 1976-1990 whereas 241Am had decreased by approximately 24%. Enhanced scavenging of 241Am and a resultant, more rapid removal from the water column relative to 239+240Pu was also supported by the observation of elevated Am/Pu activity ratios in sinking particles collected in sediment traps at depth. Direct measurements of the downward flux of particulate 239+240Pu and 241Am compared with transuranic removal rates derived from observed total water column inventory differences over time, show that particles sinking out of deep waters (1,000-2,000 m) could account for 26-72% of the computed total annual 239+240Pu loss and virtually all of the 241Am removal from the water column. Upper water column (0-200 m) residence times based on direct flux measurements ranged from 20-30 yr for 239+240Pu and 5-10 yr for 241Am. The observation that 241Am/239+240Pu activity ratios in unfiltered Mediterranean seawater are six times lower than those in the north Pacific suggests the existence of a specific mechanism for enhanced scavenging and removal of 241Am from the generally oligotrophic waters of the open Mediterranean. It is proposed that atmospheric inputs of aluminosilicate particles transported by Saharan dust events which frequently occur in the Mediterranean region could enhance the geochemical scavenging and resultant removal of 241Am to the sediments.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mode of access: Internet.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mode of access: Internet.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Includes bibliographical references (p. 14-15).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

"U.S. Atomic Energy Commission Contract AT(29-1)-1106."

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A process has been developed for the removal of chromium, copper, iron, manganese, nickel, lead, tin, and zinc impurities from an acid aqueous solution of americium chloride using a mercury cathode cell operating at 5-10 amperes and 16-18 volts. The americium is not affected. The process may also be used to remove other impurity elements.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A solution d-c arc method has been developed for the impurity analysis of americium solutions which are from 3-5 Molar in ammonium thiocyanate.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

"Contract AT (29-1)-1106."

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Although some radioecological studies have been accomplished in Brazilian soils supplying useful information to optimization of emergency planning actions in rural areas and to the management of soils contaminated by 137Cs, 60Co and 90Sr, few studies were made with transuranic elements in tropical agricultural areas. The different scenarios found in Brazilian agricultural environments enhance the importance of studying the biogeochemical behavior of radionuclides in representative soils. The objective of this work was to determine the mobility of 241Am in 3 different Brazilian agricultural soils evaluating migration with depth and Kd values for 241Am and the effect of organic amendments on this behavior. A strong effect of organic amendments on mobility of americium could be observed. The values of Kd obtained in all studied tropical soils were however smaller than those found in European soils and from those recommended by IAEA to be used as default values in the absence of regional data. This result reinforces the vulnerability of some tropical soils to a contamination, emphasizing the need to use of regional values.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Radioactive particles from three locations were investigated for elemental composition, oxidation states of matrix elements, and origin. Instrumental techniques applied to the task were scanning electron microscopy, X-ray and gamma-ray spectrometry, secondary ion mass spectrometry, and synchrotron radiation based microanalytical techniques comprising X-ray fluorescence spectrometry, X-ray fluorescence tomography, and X-ray absorption near-edge structure spectroscopy. Uranium-containing low activity particles collected from Irish Sea sediments were characterized in terms of composition and distribution of matrix elements and the oxidation states of uranium. Indications of the origin were obtained from the intensity ratios and the presence of thorium, uranium, and plutonium. Uranium in the particles was found to exist mostly as U(IV). Studies on plutonium particles from Runit Island (Marshall Islands) soil indicated that the samples were weapon fuel fragments originating from two separate detonations: a safety test and a low-yield test. The plutonium in the particles was found to be of similar age. The distribution and oxidation states of uranium and plutonium in the matrix of weapon fuel particles from Thule (Greenland) sediments were investigated. The variations in intensity ratios observed with different techniques indicated more than one origin. Uranium in particle matrixes was mostly U(IV), but plutonium existed in some particles mainly as Pu(IV), and in others mainly as oxidized Pu(VI). The results demonstrated that the various techniques were effectively applied in the characterization of environmental radioactive particles. An on-line method was developed for separating americium from environmental samples. The procedure utilizes extraction chromatography to separate americium from light lanthanides, and cation exchange to concentrate americium before the final separation in an ion chromatography column. The separated radiochemically pure americium fraction is measured by alpha spectrometry. The method was tested with certified sediment and soil samples and found to be applicable for the analysis of environmental samples containing a wide range of Am-241 activity. Proceeding from the on-line method developed for americium, a method was also developed for separating plutonium and americium. Plutonium is reduced to Pu(III), and separated together with Am(III) throughout the procedure. Pu(III) and Am(III) are eluted from the ion chromatography column as anionic dipicolinate and oxalate complexes, respectively, and measured by alpha spectrometry.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The identification of artificial radionuclides in fish involves some diffculties, because the quantities of these nuclides are very low (10-16 to 10-10 g/kg). The procedures have to be done very carefully. The sample preparation, the radiochemical analyses and the final preparation of the samples for the detection of the radioactivity of strontium-90, plutonium-238, -239, -240 and americium-241 are briefly described. The levels of artificial radioactivity in some species of fish from the North Sea are shown. The additional exposure to radiation by artificial radionuc1ides by ingestion of fish amounts only to about 0,02 % of the mean exposure to natural radiation. Nevertheless further monitoring of radioactivity should be continued in order to ensure that changes can be detected in time.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

New tri-functional ligands of the type R2NCCCH2SCH2CCNR2 (where R = iso-propyl, n-butyl or iso-butyl) were prepared and characterized. The coordination chemistry of these ligands with uranyl and lanthanum(III) nitrates was studied by using the IR, (HNMR)-H-1 and elemental analysis methods. Structures for the compounds [UO2(NO3)(2)((Pr2NCOCH2SCH2CONPr2)-Pr-i-Pr-i)] [UO2(NO3)(2)((Bu2NCOCH2SCH2CONBu2)-Bu-i-Bu-i)(2)] [La(NO3)(3)((Pr2NCOCH2SCH2CONPr2)-Pr-i-Pr-i)(2)] and [La(NO3)(3)((Bu2NCOCH2SCH2CONBu2)-Bu-i-Bu-i)(2)] were determined by single crystal X-ray diffraction. These structures show that the ligand acts as a bidentate chelating ligand and bonds through both the carbamoyl groups to the uranyl and lanthanum(III) nitrate groups. Solvent extraction studies show that the ligand can extract the uranyl ion from the nitric acid medium but does not show any ability to extract the americium (III) ion. (C) 2009 Elsevier Ltd. All rights reserved.