881 resultados para Alveolar particle deposition
Resumo:
Vertical number fluxes of aerosol particles and vertical fluxes of CO(2) were measured with the eddy covariance method at the top of a 53 m high tower in the Amazon rain forest as part of the LBA (The Large Scale Biosphere Atmosphere Experiment in Amazonia) experiment. The observed aerosol number fluxes included particles with sizes down to 10 nm in diameter. The measurements were carried out during the wet and dry season in 2008. In this study focus is on the dry season aerosol fluxes, with significant influence from biomass burning, and these are compared with aerosol fluxes measured during the wet season. Net particle deposition fluxes dominated in daytime in both seasons and the deposition flux was considerably larger in the dry season due to the much higher dry season particle concentration. The particle transfer velocity increased linearly with increasing friction velocity in both seasons. The difference in transfer velocity between the two seasons was small, indicating that the seasonal change in aerosol number size distribution is not enough for causing any significant change in deposition velocity. In general, particle transfer velocities in this study are low compared to studies over boreal forests. The reasons are probably the high percentage of accumulation mode particles and the low percentage of nucleation mode particles in the Amazon boundary layer, both in the dry and wet season, and low wind speeds in the tropics compared to the midlatitudes. In the dry season, nocturnal particle fluxes behaved very similar to the nocturnal CO(2) fluxes. Throughout the night, the measured particle flux at the top of the tower was close to zero, but early in the morning there was an upward particle flux peak that is not likely a result of entrainment or local pollution. It is possible that these morning upward particle fluxes are associated with emission of primary biogenic particles from the rain forest. Emitted particles may be stored within the canopy during stable conditions at nighttime, similarly to CO(2), and being released from the canopy when conditions become more turbulent in the morning.
Resumo:
The existence of a reversed magnetic shear in tokamaks improves the plasma confinement through the formation of internal transport barriers that reduce radial particle and heat transport. However, the transport poloidal profile is much influenced by the presence of chaotic magnetic field lines at the plasma edge caused by external perturbations. Contrary to many expectations, it has been observed that such a chaotic region does not uniformize heat and particle deposition on the inner tokamak wall. The deposition is characterized instead by structured patterns called magnetic footprints, here investigated for a nonmonotonic analytical plasma equilibrium perturbed by an ergodic limiter. The magnetic footprints appear due to the underlying mathematical skeleton of chaotic magnetic field lines determined by the manifold tangles. For the investigated edge safety factor ranges, these effects on the wall are associated with the field line stickiness and escape channels due to internal island chains near the flux surfaces. Comparisons between magnetic footprints and escape basins from different equilibrium and ergodic limiter characteristic parameters show that highly concentrated magnetic footprints can be avoided by properly choosing these parameters. (c) 2008 American Institute of Physics.
Resumo:
A theory is developed for calculating the entrapment of particles by a windbreak, with four results. (1) The fraction of particles in the oncoming flow which pass through the windbreak, or transmittance of the windbreak for particles (sigma), is related to the optical porosity (tau). The very simple approximation sigma=tau works well for most applications involving the interception of spray droplets by windbreaks. Results from a field experiment agree with the theoretical predictions. (2) A new equation for the bulk drag coefficient of a windbreak is tested against numerical, wind tunnel and field experiments. This enables the bleed velocity for the flow through the windbreak to be predicted in terms of the screen pressure coefficient (k) of the barrier. (3) The relationship between k and tau is different for a vegetative barrier than for a screen across a confined duct, implying a lower Fc for given tau. (4) The total deposition of particles to a windbreak is determined by a trade-off between particle absorption and throughflow, implying an optimum value of tau for maximum total deposition. For particles larger than 30 mum and vegetation elements smaller than 30 mm, this occurs near tau = 0.2. (C) 2001 Elsevier Science Ltd. All rights reserved.
Resumo:
In this work, 14 primary schools of Lisbon city, Portugal, followed a questionnaire of the ISAAC - International Study of Asthma and Allergies in Childhood Program, in 2009/2010. The questionnaire contained questions to identify children with respiratory diseases (wheeze, asthma and rhinitis). Total particulate matter (TPM) was passively collected inside two classrooms of each of 14 primary schools. Two types of filter matrices were used to collect TPM: Millipore (IsoporeTM) polycarbonate and quartz. Three campaigns were selected for the measurement of TPM: Spring, Autumn and Winter. The highest difference between the two types of filters is that the mass of collected particles was higher in quartz filters than in polycarbonate filters, even if their correlation is excellent. The highest TPM depositions occurred between October 2009 and March 2010, when related with rhinitis proportion. Rhinitis was found to be related to TPM when the data were grouped seasonally and averaged for all the schools. For the data of 2006/2007, the seasonal variation was found to be related to outdoor particle deposition (below 10 μm).
Resumo:
Coagulopathy and alveolar fibrin deposition are common in sick neonates and attributed to the primary disease, as opposed to their ventilatory support. Hypothesizing that high tidal volume ventilation activates the extrinsic coagulation pathway, we air ventilated newborn and adult rats at low (10 ml/kg) or high (30 ml/kg) tidal volume and compared them with age-matched nonventilated controls. Blood was collected at the end of the experiment for measurement of clot time, tissue factor, and other coagulation factor content. Similar measurements were obtained from lung lavage material. The newborn clot time (44+/-1) was lower and plasma tissue factor content higher (103.4+/-0.4) than adults (88+/-4 s and 26.6+/-1.4 units; P<0.01). High, but not low, tidal volume ventilation of newborns for as little as 15 min significantly reduced clot time and increased plasma tissue factor content (P<0.01). High volume ventilation increased plasma factor Xa (0.1+/-0.1 to 1.6+/-0.4 nM; P<0.01) and thrombin (1.3+/-0.2 to 2.2+/-0.4 nM; P<0.05) and decreased antithrombin (0.12+/-0.01 to 0.05+/-0.01; P<0.01) in the newborn. Lung lavage material of high volume-ventilated newborns showed increased (P<0.01) factor Xa and thrombin. No changes in these parameters were observed in adult rats that were high volume ventilated for up to 90 min. Compared with adults, newborn rats have a greater propensity for volutrauma-activated intravascular coagulation. These data suggest that mechanical ventilation promotes neonatal thrombosis via lung tissue factor release.
Resumo:
Neste experimento, utilizaram-se cinco aquários cilíndricos com relevo no fundo (em forma de anel) e cinco retangulares com fundo liso para estudo da influência do formato do aquário na sobrevivência e no desenvolvimento de larvas de matrinxã Brycon cephalus. Observou-se melhor eficiência dos aquários retangulares, confirmada pela maior sobrevivência e biomassa. Os valores de temperatura, pH, condutividade e oxigênio dissolvido foram similares entre os tipos de aquários, sugerindo que esses parâmetros não influenciaram os resultados. O relevo no fundo dos aquários cilíndricos afetou negativamente o cultivo de larvas de matrinxã, pela criação de zonas com pequena capacidade da água em suspender partículas, o que resultou em acúmulo de dejetos, predadores, competidores e alimento. Aquários retangulares com fundo liso são mais adequados ao cultivo de larvas de matrinxã, por promover melhor circulação da água.
Resumo:
The feasibility of Portland cement analysis by introduction of slurries in an inductively coupled plasma optical emission spectrometer (ICP-OES) with axial viewing has been evaluated. After a fast manual grinding of the cement samples, owing to the pulverized state of this material, 0.1% m/v slurries were prepared in 1% v/v HCl. The calibration was performed adopting two strategies: one based on slurries prepared from different masses (50, 75, 100 and 125 mg) of a Portland cement standard reference material (NIST SRM 1881), and the other one based on aqueous reference solutions. A complete analysis of cement for major (Al, Ca, Fe, Mg and Si), minor and trace elements (Mn, P, S, Sr and Ti) was accomplished. Both strategies led to accurate results for commercial Portland cement samples, except for Si and Ti. for which the calibration with aqueous reference solutions resulted in low values. Applying a paired t-test it was shown that most results were in agreement at a 95% confidence level with a conventional fusion decomposition procedure. The ICP-OES with axial viewing and end-on gas configuration for removal of the recombination plasma zone was effective for cement slurry analysis without any undesirable particle deposition in the pre-optics interface and without severe spectral interferences. (C) 2002 Elsevier B.V. B.V. All rights reserved.
Resumo:
Aim: The purpose of this study was to compare the effectiveness of a high-volume evacuation and a conventional intraoral suction system and aspirating tips for capturing aluminum oxide particles during use of an air-abrasion device. Methods: A phantom head was fixed at the dental chair head with secured a metallic device with 5 horizontal shafts, corresponding to operator's clockrelated working positions, and one vertical shaft to simulate the operator's nasal cavity. Petri plates were fixed to the shafts at distances of 20, 40 and 60 cm from the center of the oral cavity of the phantom head to collect the aluminum oxide particles spread over during air abrasion. The dust was aspirated with two types of suction tips used with both suction systems: a conventional saliva ejector and a saliva ejector customized by the adaptation of a 55-mm-diameter funnel. Results: The amount of particles showed that the greatest abrasive particle deposition occurred at a distance of 20 cm from the center of the oral cavity of the phantom head at 9 o'clock operatory position with the conventional saliva ejector attached to high-volume evacuation system. Conclusions: The greatest deposition of aluminum oxide particles occurred at the shortest distance between the operator and the center of the oral cavity, while using the high-volume evacuation system associated to the conventional suction tip.
Resumo:
Objective: To evaluate the effects of simulated aging in bond strength and nanoleakage of class II restorations using three different restorative techniques. Materials and methods: Class II preparations (n = 12) were restored using: FS - composite resin Filtek Supreme Plus (3M/ESPE); RMGIC + FS - resin-modified glass ionomer cement Vitrebond Plus (3M/ESPE) + FS; and FFS + FS - flowable composite resin Filtek Supreme Plus Flowable (3M ESPE) + FS. The teeth were assigned into two groups: Control and Simulated Aging - Thermal/Mechanical cycling (3,000 cycles, 20-80 °C/500,000 cycles, 50 N). From each tooth, two slabs were assessed to microtensile bond strength test (μTBS) (MPa), and two slabs were prepared for nanoleakage assessment, calculated as penetration along the restoration margin considering the penetration length (%) and as the area of silver nitrate particle deposition (μm2). Data were analyzed by two-way analysis of variance (ANOVA) followed by Tukey's post hoc test (p < 0. 05). Results: FS presented the highest μTBS to dentin (22. 39 ± 7. 55 MPa) after simulated aging, while the presence of flowable resin significantly decreased μTBS (14. 53 ± 11. 65 MPa) when compared to no aging condition. Both control and aging groups of RMGIC + FS presented the highest values of silver nitrate penetration (89. 90 ± 16. 31 % and 97. 14 ± 5. 76 %) and deposition area (33. 05 ± 12. 49 and 28. 08 ± 9. 76 μm2). Nanoleakage was not affected by simulated aging. Conclusions: FS presented higher bond strength and lower nanoleakage and was not affected by simulated aging. Use of flowable resin compromised the bond strength after simulated aging. Clinical relevance: The use of an intermediate layer did not improve the dentin bond strength neither reduced nanoleakage at the gingival margins of class II restorations under simulated aging conditions. © 2012 Springer-Verlag.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Extremely arid conditions in tropical Africa occurred in several discrete episodes between 135 and 90 ka, as demonstrated by lake core and seismic records from multiple basins [Scholz CA, Johnson TC, Cohen AS, King JW, Peck J, Overpeck JT, Talbot MR, Brown ET, Kalindekafe L,Amoako PYO, et al. (2007) Proc Natl Acad SciUSA104:16416–16421]. This resulted in extraordinarily low lake levels, even in Africa’s deepest lakes.On the basis of well dated paleoecological records from Lake Malawi, which reflect both local and regional conditions, we show that this aridity had severe consequences for terrestrial and aquatic ecosystems. During the most arid phase, there was extremely low pollen production and limited charred-particle deposition, indicating insufficient vegetation to maintain substantial fires, and the Lake Malawi watershed experienced cool, semidesert conditions (<400 mm>/yr precipitation). Fossil and sedimentological data show that Lake Malawi itself, currently 706mdeep, was reduced to an ~125 m deep saline, alkaline, well mixed lake. This episode of aridity was far more extreme than any experienced in the Afrotropics during the Last Glacial Maximum (~35–15 ka). Aridity diminished after 95 ka, lake levels rose erratically, and salinity/alkalinity declined, reaching near-modern conditions after 60 ka. This record of lake levels and changing limnological conditions provides a framework for interpreting the evolution of the Lake Malawi fish and invertebrate species flocks. Moreover, this record, coupled with other regional records of early Late Pleistocene aridity, places new constraints on models of Afrotropical biogeographic refugia and early modern human population expansion into and out of tropical Africa.
Resumo:
Die hygroskopischen Eigenschaften sind wichtige Parameter des atmosphärischen Aerosols. Sie beeinflussen sowohl direkt über den Strahlungsantrieb, als auch indirekt über die Wechselwirkung von Aerosol und Wolken die globale Strahlungsbilanz und somit das Klima. Auch die Sichtweiteveränderung ist von ihnen abhängig. Sie beeinflussen die Partikeldeposition in der Lunge und müssen zur Vermeidung von Artefaktbildung bei der Aerosolmessung berücksichtigt werden.
Die vorliegende Dissertation beinhaltet Messungen des wasserlöslichen Volumenanteils und des hygroskopischen Wachstumsfaktors des atmosphärischen Aerosols. Mit diesen Untersuchungen konnte der überwiegende Teil (50 nm bis 4 µm Partikeldurchmesser) des für atmosphärische Prozesse relevanten Größenbereichs gleichzeitig größenaufgelöst und detailliert erfasst werden. Messungen wurden in ruralen, semi-urbanen und frei-troposphärischen Luftmassen durchgeführt. Messverfahren sind die SoFA (Water-Soluble Fraction of Large and Giant Atmospheric Particles)-Methode und der HTDMA (Hygroscopic Tandem Differential Mobility Analyzer). Im Rahmen dieser Arbeit wurde die SoFA-Methode weiterentwickelt.
Ein umfangreiches Messprogramm zeigt, dass der mittlere lösliche Volumenanteil des Aerosols mit Werten von ca. 59 % geringe Variationen zwischen den Messstandorten aufweist, lediglich in frei-troposphärischen Luftmassen liegt er mit 66 % erwartungsgemäß höher. Betrachtet man die Daten größenaufgelöst, so zeigt sich, dass im Größenbereich zwischen 200 und 500 nm Partikeldurchmesser der lösliche Volumenanteil ein Maximum aufweist. Ein in semi-urbanem Aerosol gemessener Jahresgang weist, vor allem für Partikel kleiner 300 nm, im Sommer geringere Werte als im Winter auf. Unterhalb 300 nm Partikeldurchmesser treten üblicherweise zwei, oberhalb bis zu drei Partikeltypen unterschiedlicher Hygroskopizität auf: der fast unlösliche Partikeltyp mit löslichen Volumenanteilen bis 12 %, der wahrscheinlich aus Ruß, sekundärem organischem, mineralischem und biologischem Material besteht; der teilweise lösliche Partikeltyp (50 bis 75 %), der als Mischpartikel anzusprechen ist; schließlich der überwiegend lösliche Partikeltyp (ca. 90 %), der wahrscheinlich durch Wolkenprozessierung entsteht. Der Unterschied zwischen den Messstandorten ist auch hier gering. Üblicherweise dominieren die löslicheren Partikeltypen mit relativen Anteilen von 60 bis 95 %, wobei sich ein Minimum der Häufigkeit der löslicheren Partikel zwischen 1.5 und 2.5 µm zeigt. Abschließende größenaufgelöste Modellrechnungen zum Aerosol-Feuchtewachstum unterstreichen die Relevanz dieser Untersuchungen für Strahlungs- und Wolkenprozesse.
Resumo:
Nowadays, aerosol processes are widely used for the manufacture of nanoparticles (NPs), creating an increased occupational exposure risk of workers, laboratory personnel and scientists to airborne particles. There is evidence that possible adverse effects are linked with the accumulation of NPs in target cells, pointing out the importance of understanding the kinetics of particle internalization. In this context, the uptake kinetics of representative airborne NPs over 30 min and their internalization after 24 h post-exposure were investigated by the use of a recently established exposure system. This system combines the production of aerosolized cerium oxide (CeO(2)) NPs by flame spray synthesis with its simultaneous particle deposition from the gas-phase onto A549 lung cells, cultivated at the air-liquid interface. Particle uptake was quantified by mass spectrometry after several exposure times (0, 5, 10, 20 and 30 min). Over 35% of the deposited mass was found internalized after 10 min exposure, a value that increased to 60% after 30 min exposure. Following an additional 24 h post-incubation, a time span, after which adverse biological effects were observed in previous experiments, over 80% of total CeO(2) could be detected intracellularly. On the ultrastructural level, focal cerium aggregates were present on the apical surface of A549 cells and could also be localized intracellularly in vesicular structures. The uptake behaviour of aerosolized CeO(2) is in line with observations on cerium suspensions, where particle mass transport was identified as the rate-limiting factor for NP internalization.
Resumo:
Inhaled particles may cause increased pulmonary and cardiovascular morbidity and mortality. The wall structures of airways and alveoli act as a series of structural and functional barriers against inhaled particles. Deposited particles are displaced and come into close association with epithelial cells, macrophages and dendritic cells. The cellular interplay after particle deposition in a triple cell co-culture model of the human airway wall was investigated by laser scanning microscopy. Furthermore, the cellular response was determined by measurement of TNF-alpha. Dendritic cells gained access to the apical side of the epithelium where they sampled particles and interacted with macrophages.
Resumo:
The small trees of gas-exchanging pulmonary airways which are fed by the most distal purely conducting airways are called acini and represent the functional gas-exchanging units. The three-dimensional architecture of the acini has a strong influence on ventilation and particle deposition. Due to the difficulty to identify individual acini on microscopic lung sections the knowledge about the number of acini and their biological parameters like volume, surface area, and number of alveoli per acinus are limited. We developed a method to extract individual acini from lungs imaged by high-resolution synchrotron radiation based X-ray tomographic microscopy and estimated their volume, surface area and number of alveoli. Rat acini were isolated by semiautomatically closing the airways at the transition from conducting to gas-exchanging airways. We estimated a mean internal acinar volume of 1.148mm(3), a mean acinar surface area of 73.9mm(2), and a mean of 8470 alveoli per acinus. Assuming that the acini are similarly sized throughout different regions of the lung, we calculated that a rat lung contains 5470±833 acini. We conclude that our novel approach is well suited for the fast and reliable characterization of a large number of individual acini in healthy, diseased, or transgenic lungs of different species including humans.