939 resultados para Alveolar dose


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: The aim of this systematic review was to evaluate clinical and safety data for recombinant human bone morpho-genetic protein-2 (rhBMP-2) in an absorbable collagen sponge (ACS) carrier when used for alveolar ridge/maxillary sinusaugmentation in humans.Materials and Methods: Clinical studies/case ser ies published 1980 through June 2012 using rhBMP-2/ACS were searched.Studies meeting the following criteria were considered eligible for inclusion: >10 subjects at baseline and maxillary sinus oralveolar ridge augmentation not concomitant with implant placement.Results: Seven of 69 publications were eligible for review. rhBMP-2/ACS yielded clinically meaningful bone formationfor maxillary sinus augmentation that would allow placement of regular dental implants without consistent differencesbetween rhBMP-2 concentrations. Never theless, the statistical analysis showed that sinus augmentation following autog-enous bone graft was significantly greater (mean bone height: 1.6 mm, 95% CI: 0.5–2.7 mm) than for rhBMP-2/ACS(rhBMP-2 at 1.5 mg/mL). In extraction sockets, rhBMP-2/ACS maintained alveolar ridge height while enhancing alve olarridge width. Safety reports did not represent concerns for the proposed indications.Conclusions: rhBMP-2/ACS appears a promising alternative to autogenous bone grafts for alveolar ridge/maxillary sinusaugmentation; dose and carrier optimization may expand its efficacy, use, and clinical application.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Pós-graduação em Odontologia - FOAR

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We compared outcomes of alveolar hemorrhage (AH) in juvenile (JSLE) and adult onset SLE (ASLE). From 263 JSLE and 1522 ASLE, the AH occurred in 13 (4.9%) and 15 (1.0%) patients, respectively (p < .001). Both groups had comparable disease duration (2.6 +/- 3.0 vs. 5.6 +/- 7.0 years, p = .151) and median SLEDAI scores [17.5 (2 to 32) vs. 17.5 (3 to 28), p = 1.000]. At AH onset, a higher frequency of JSLE were already on a high prednisone dose ( > 0.5 mg/kg/day) compared to ASLE (54% vs. 15%, p = .042). The mean drop of hemoglobin was significantly lower in JSLE (2.9 +/- 0.9 vs. 5.5 +/- 2.9 g/dL, p = .006). Although treatments with methylprednisolone, plasmapheresis, intravenous immunoglobulin and cyclophosphamide were similar in both groups (p > .050), regarding outcomes, there was a trend in high frequency of mechanical ventilation use (85% vs. 47%, p = .055) and also significant mortality (69% vs. 13%, p = .006) in JSLE compared to ASLE. The sepsis frequency was comparable in both groups (50% vs. 27%, p = .433). We have identified that AH in JSLE has a worse outcome most likely related to respiratory failure. The AH onset in JSLE already treated with high-dose steroids raises the concern of inadequate response to this treatment and reinforces the recommendation of early aggressive alternative therapies in this group of patients. Lupus (2012) 21, 872-877.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Engineered nanoparticles are becoming increasingly ubiquitous and their toxicological effects on human health, as well as on the ecosystem, have become a concern. Since initial contact with nanoparticles occurs at the epithelium in the lungs (or skin, or eyes), in vitro cell studies with nanoparticles require dose-controlled systems for delivery of nanoparticles to epithelial cells cultured at the air-liquid interface. RESULTS: A novel air-liquid interface cell exposure system (ALICE) for nanoparticles in liquids is presented and validated. The ALICE generates a dense cloud of droplets with a vibrating membrane nebulizer and utilizes combined cloud settling and single particle sedimentation for fast (~10 min; entire exposure), repeatable (<12%), low-stress and efficient delivery of nanoparticles, or dissolved substances, to cells cultured at the air-liquid interface. Validation with various types of nanoparticles (Au, ZnO and carbon black nanoparticles) and solutes (such as NaCl) showed that the ALICE provided spatially uniform deposition (<1.6% variability) and had no adverse effect on the viability of a widely used alveolar human epithelial-like cell line (A549). The cell deposited dose can be controlled with a quartz crystal microbalance (QCM) over a dynamic range of at least 0.02-200 mug/cm(2). The cell-specific deposition efficiency is currently limited to 0.072 (7.2% for two commercially available 6-er transwell plates), but a deposition efficiency of up to 0.57 (57%) is possible for better cell coverage of the exposure chamber. Dose-response measurements with ZnO nanoparticles (0.3-8.5 mug/cm(2)) showed significant differences in mRNA expression of pro-inflammatory (IL-8) and oxidative stress (HO-1) markers when comparing submerged and air-liquid interface exposures. Both exposure methods showed no cellular response below 1 mug/cm(2 )ZnO, which indicates that ZnO nanoparticles are not toxic at occupationally allowed exposure levels. CONCLUSION: The ALICE is a useful tool for dose-controlled nanoparticle (or solute) exposure of cells at the air-liquid interface. Significant differences between cellular response after ZnO nanoparticle exposure under submerged and air-liquid interface conditions suggest that pharmaceutical and toxicological studies with inhaled (nano-)particles should be performed under the more realistic air-liquid interface, rather than submerged cell conditions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The metacestode (larval) stage of the tapeworm Echinococcus multilocularis causes alveolar echinococcosis (AE), a very severe and in many cases incurable disease. To date, benzimidazoles such as albendazole and mebendazole are the only approved chemotherapeutical treatment options. Benzimidazoles inhibit metacestode proliferation, but do not act parasiticidal. Thus, benzimidazoles have to be taken a lifelong, can cause adverse side effects such as hepatotoxicity, and are ineffective in some patients. We here describe a newly developed screening cascade for the evaluation of the in vitro efficacy of new compounds that includes assessment of parasiticidal activity. The Malaria Box from Medicines for Malaria Venture (MMV), comprised of 400 commercially available chemicals that show in vitro activity against Plasmodium falciparum, was repurposed. Primary screening was carried out at 10 μM by employing the previously described PGI assay, and resulted in the identification of 24 compounds that caused physical damage in metacestodes. Seven out of these 24 drugs were also active at 1 μM. Dose-response assays revealed that only 2 compounds, namely MMV665807 and MMV665794, exhibited an EC50 value below 5 μM. Assessments using human foreskin fibroblasts and Reuber rat hepatoma cells showed that the salicylanilide MMV665807 was less toxic for these two mammalian cell lines than for metacestodes. The parasiticidal activity of MMV665807 was then confirmed using isolated germinal layer cell cultures as well as metacestode vesicles by employing viability assays, and its effect on metacestodes was morphologically evaluated by electron microscopy. However, both oral and intraperitoneal application of MMV665807 to mice experimentally infected with E. multilocularis metacestodes did not result in any reduction of the parasite load.