978 resultados para Acid solutions


Relevância:

70.00% 70.00%

Publicador:

Resumo:

Fluorescence is a troublesome side effect in laboratory Raman studies on sulfuric acid solutions and aerosol particles. We performed experiments showing that organic matter induces fluorescence in H2SO4/H2O solutions. The intensity of the fluorescence signal appears to be almost independent of the concentration of the organic substances, but depends strongly on the sulfuric acid concentration. The ubiquity of organic substances in the atmosphere, their relatively high abundance, and the insensitivity of the fluorescence with respect to their concentrations will render most acidic natural aerosols subject to absorption and fluorescence, possibly influencing climate forcing. We show that, while fluorescence may in the future become a valuable tool of aerosol diagnostics, the concurrent absorption is too small to significantly affect the atmosphere's radiative balance.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Microwave-assisted sample preparation using diluted nitric acid solutions is an alternative procedure for digesting organic samples. The efficiency of this procedure depends on the chemical properties of the samples and in this work it was evaluated by the determination of crude protein amount. fat and original carbon. Soybeans grains, bovine blood. bovine muscle and bovine viscera were digested in a cavity-microwave oven using oxidant mixtures in different acid concentrations. The digestion efficiency was evaluated based on the determination of residual carbon content and element recoveries using inductively coupled plasma optical emission spectrometry (ICP OES). In order to determine the main residual organic compounds, the digests were characterized by nuclear magnetic resonance (1 H NMR). Subsequently, studies concerning separation of nitrobenzoic acid isomers were performed by ion pair reversed phase liquid chromatography using a C18 stationary phase, water:acetonitrile:methanol (75:20:5, v/v/v) +0.05% (v/v) TFA as mobile phase and ultraviolet detection at 254 nm. Sample preparation based on diluted acids proved to be feasible and a recommendable alternative for organic sample digestion, reducing both the reagent volumes and the variability of the residues as a result of the process of decomposition. It was shown that biological matt-ices containing amino acids, proteins and lipids in their composition produced nitrobenzoic acid isomers and other organic compounds after cleavage of chemical bonds. (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The aims of this study were to determine the effects of pH and acid concentration on the dissolution of enamel, dentine, and compressed hydroxyapatite (HA) in citric acid solutions (15.6 and 52.1 mmol l(-1) ; pH 2.45, 3.2, and 3.9), using a pH-stat system. After an initial adjustment period, the dissolution rates of enamel and HA were constant, while that of dentine decreased with time. The dissolution rate increased as the pH decreased, and this was most marked for enamel. To compare substrates, the rate of mineral dissolution was normalized to the area occupied by mineral at the specimen surface. For a given acid concentration, the normalized dissolution rate of HA was always less than that for either dentine or enamel. The dissolution rate for dentine mineral was similar to that for enamel at pH 2.45 and greater at pH 3.2 and pH 3.9. The concentration of acid significantly affected the enamel dissolution rate at pH 2.45 and pH 3.2, but not at pH 3.9, and did not significantly affect the dissolution rates of dentine or HA at any pH. The variation in response of the dissolution rate to acid concentration/buffer capacity with respect to pH and tissue type might complicate attempts to predict erosive potential from solution composition.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Results of a systematic study concerning non-spectral interferences from sulfuric acid containing matrices on a large number of elements in inductively coupled plasma–mass spectrometry (ICP-MS) are presented in this work. The signals obtained with sulfuric acid solutions of different concentrations (up to 5% w w− 1) have been compared with the corresponding signals for a 1% w w− 1− nitric acid solution at different experimental conditions (i.e., sample uptake rates, nebulizer gas flows and r.f. powers). The signals observed for 128Te+, 78Se+ and 75As+ were significantly higher when using sulfuric acid matrices (up to 2.2-fold for 128Te+ and 78Se+ and 1.8-fold for 75As+ in the presence of 5 w w-1 sulfuric acid) for the whole range of experimental conditions tested. This is in agreement with previously reported observations. The signal for 31P+ is also higher (1.1-fold) in the presence of sulfuric acid. The signal enhancements for 128Te+, 78Se+, 75As+ and 31P+ are explained in relation to an increase in the analyte ion population as a result of charge transfer reactions involving S+ species in the plasma. Theoretical data suggest that Os, Sb, Pt, Ir, Zn and Hg could also be involved in sulfur-based charge transfer reactions, but no experimental evidence has been found. The presence of sulfuric acid gives rise to lower ion signals (about 10–20% lower) for the other nuclides tested, thus indicating the negative matrix effect caused by changes in the amount of analyte loading of the plasma. The elemental composition of a certified low-density polyethylene sample (ERM-EC681K) was determined by ICP-MS after two different sample digestion procedures, one of them including sulfuric acid. Element concentrations were in agreement with the certified values, irrespective of the acids used for the digestion. These results demonstrate that the use of matrix-matched standards allows the accurate determination of the tested elements in a sulfuric acid matrix.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Ethanol oxidation has been studied on stepped platinum single crystal electrodes in acid media using electrochemical and Fourier transform infrared (FTIR) techniques. The electrodes used belong to two different series of stepped surfaces: those having (111) terraces with (100) monoatomic steps and those with (111) terraces with (110) monoatomic steps. The behaviors of the two series of stepped surfaces for the oxidation of ethanol are very different. On the one hand, the presence of (100) steps on the (111) terraces provides no significant enhancement of the activity of the surfaces. On the other hand, (110) steps have a double effect on the ethanol oxidation reaction. At potentials below 0.7 V, the step catalyzes the C-C bond cleavage and also the oxidation of the adsorbed CO species formed. At higher potentials, the step is not only able to break the C-C bond, but also to catalyze the oxidation of ethanol to acetic acid and acetaldehyde. The highest catalytic activity from voltammetry for ethanol oxidation was obtained with the Pt(554) electrode.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Ethanol oxidation has been studied on Pt(111), Pt(100) and Pt(110) electrodes in order to investigate the effect of the surface structure and adsorbing anions using electrochemical and FTIR techniques. The results indicate that the surface structure and anion adsorption affect significantly the reactivity of the electrode. Thus, the main product of the oxidation of ethanol on the Pt(111) electrode is acetic acid, and acetaldehyde is formed as secondary product. Moreover, the amount of CO formed is very small, and probably associated with the defects present on the electrode surface. For that reason, the amount of CO(2) is also small. This electrode has the highest catalytic activity for the formation of acetic acid in perchloric acid. However, the formation of acetic acid is inhibited by the presence of specifically adsorbed anions, such as (bi) sulfate or acetate, which is the result of the formation of acetic acid. On the other hand, CO is readily formed at low potentials on the Pt(100) electrode, blocking completely the surface. Between 0.65 and 0.80 V, the CO layer is oxidized and the production of acetaldehyde and acetic acid is detected. The Pt(110) electrode displays the highest catalytic activity for the splitting of the C-C bond. Reactions giving rise to CO formation, from either ethanol or acetaldehyde, occur at high rate at any potential. On the other hand, the oxidation of acetaldehyde to acetic acid has probably the lower reaction rate of the three basal planes.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Oxidation of ethanol on ruthenium-modified Pt(775) and Pt(332) stepped electrodes has been studied using electrochemical and FTIR techniques. It has been found that the oxidation of ethanol on these electrodes takes place preferentially on the step sites yielding CO(2) as the major final product. The cleavage of the C-C bond, which is the required step to yield CO(2), occurs only on this type of site. The presence of low ruthenium coverages on the step sites promotes the complete oxidation of ethanol since it facilitates the oxidation of CO formed on the step from the cleavage of the C-C bond. However, high ruthenium coverages have an important inhibiting effect since the adatoms block the step sites, which are required for the cleavage of the C-C bond. Under these conditions, the oxidation current diminishes and the major product in the oxidation process is acetic acid, which is the product formed preferentially on the (111) terrace sites.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Ethanol oxidation on platinum stepped surfaces vicinal to the (111) pole modified by tin has been studied to determine the role of this adatom in the oxidation mechanism. Tin has been slowly deposited so that the initial stages of the deposition take place on the step, and deposition on the terrace only occurs when the step has been completely decorated. Voltammetric and chronoamperometric experiments demonstrate that tin on the step catalyzes the oxidation. The maximum enhancement is found when the step is completely decorated by tin. FTIR experiments using normal and isotopically labeled ethanol have been used to elucidate the effect of the tin adatoms in the mechanism. The obtained results indicate that the role of tin is double: (i) when the surface has sites capable of breaking the C-C bond of the molecule, that is, when the step sites are not completely covered by tin, it promotes the oxidation of CO formed from the molecular fragments to CO(2) through a bifunctional mechanism and (ii) it catalyzes the oxidation of ethanol to acetic acid.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A mudança no mercado global do petróleo nos últimos anos, com o declínio das reservas de óleo leve, têm forçado a busca por novos campos petrolíferos em ambientes mais remotos, como nos campos localizados na camada pré-sal, e a exploração de óleos pesados que possuem elevado teor de ácidos naftênicos. Isso acarreta em grandes desafios para a previsão do desempenho de materiais frente às novas condições ambientais em que estão inseridos. No presente trabalho, o comportamento da corrosão do aço carbono AISI 1010 e do aço inoxidável AISI 316L foi estudado em soluções aquosas com elevado teor de cloreto e em solução de ácido naftênico ciclopentanóico a fim de ter melhor entendimento da ação dessas espécies no processo de corrosão e simular a corrosão pela água de produção na indústria petrolífera. Foram aplicadas as técnicas de potencial de circuito aberto, polarização potenciodinâmica, voltametria cíclica, espectroscopia de impedância eletroquímica, espectroscopia Raman, microscopia eletrônica de varredura e microscopia de força atômica, usadas, em cada caso, de acordo com a conveniência. O aumento da [Cl-] na faixa de 1,2–2,8 mol.L-1 não altera os processos catódicos e anódicos perto do Ecorr para os aços AISI 1010 e AISI 316L. Em condições de sobrepotenciais afastados do Ecorr, o aumento de [Cl-] aumenta os processos oxidativos de corrosão, o que é expresso pelas maiores densidades de corrente e carga anódica e aumento da perda de massa sofrida pelos eletrodos de ambos os aços. Portanto, os danos da corrosão são mais intensos quando se aumenta a [Cl-]. O aço AISI 1010 é ativo nas soluções de NaCl e a corrosão se propaga livremente de forma uniforme. Para o aço AISI 316L, uma ampla faixa de passividade pode ser vista nas soluções de NaCl; no Epit ocorre a ruptura do filme passivo e o crescimento de pites estáveis. Após 24 h de imersão em soluções de sulfato de sódio (branco) e de ácido naftênico ciclopentanóico ocorre crescimento de filme de óxido e as fases α-Fe2O3, Fe3O4 e δ-FeO(OH) foram identificadas nos espécimes de aço AISI 1010 e Fe3O4 foi identificado nos defeitos do filme prévio presente na superfície do aço AISI 316L. Os filmes formados em solução de ácido ciclopentanóico possuem menor resistência à polarização, maior rugosidade e maior taxa de corrosão quando comparado aos filmes crescidos na solução branco, para ambos os aços. A presença do ácido naftênico muda a forma como a reação de corrosão se procede e contribui para o aumento da corrosão. A corrosão naftênica foi mais pronunciada no aço carbono porque a presença dos elementos de liga no aço inox reduzem o número de sítios ativos ricos em Fe e tornam menos oportuna a ligação do Fe com o naftenato.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In the present work we investigate the ageing of acid cleaned femtosecond laser textured < 100 > silicon surfaces. Changes in the surface structure and chemistry were analysed by Rutherford backscattering spectrometry (RBS) and X-ray photoelectron spectroscopy (XPS), in order to explain the variation with time of the water contact angles of the laser textured surfaces. It is shown that highly hydrophobic silicon surfaces are obtained immediately after laser texturing and cleaning with acid solutions (water contact angle >120 degrees). However these surfaces are not stable and ageing leads to a decrease of the water contact angle which reaches a value of 80 degrees. XPS analysis of the surfaces shows that the growth of the native oxide layer is most probably responsible for this behavior. (C) 2010 Elsevier B.V. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Electrochemical oxidation of propanil in deuterated solutions was studied by cyclic, differential pulse, and square wave voltammetry using a glassy carbon microelectrode. The oxidation of propanil in deuterated acid solutions occurs at the nitrogen atom of the amide at a potential of +1.15 V vs Ag/ AgCl. It was also found that, under the experimental conditions used, protonation at the oxygen atom of propanil occurs, leading to the appearance of another species in solution which oxidizes at +0.60 V. The anodic peak found at +0.79 V vs Ag/AgCl in deuterated basic solutions is related to the presence of an anionic species in which a negative charge is on the nitrogen atom. The electrochemical data were confirmed by the identification of all the species formed in acidic and basic deuterated solutions by means of NMR spectroscopy. The results are supported by electrochemical and spectroscopic studies of acetanilide in deuterated solutions.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Mestrado Engenharia Química. Ramo Tecnologias de Protecção Ambiental

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The photometric determination of ascorbic acid with the "E. E. L. portable colorimeter" can be carried" out rapid and conveniently using either 3% HPO3 or 0,4% (COOH) 2 as protective agent. The standards would contain from 2 to 20 micrograms of ascorbic acid per ml of metaphosphoric or oxalic acid solutions. We mix 10 ml of these solutions with 3 ml of the adequate citrate buffer solutions, and we pipet 5 ml of the resulting mixture to a matched test tube containing 5 ml of sodium - 2,6 - dichlorobenzenoneindophenol (80 mg per liter); then we shake well and after 15 seconds the extintion is read using green filter. The readings are subtracted from the blank one. Designating the differences by x and the concentrations of ascorbic acid/ml in the standards by y, we get, with the acid of the method of least squares, the following regression equations: for the metaphosphoric acid Y = 0,543x + 0,629 for the oxalic acid Y = 0,516x + 0,422, which permit, by interpolating, the determination of the ascorbic acid content in plant materials.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fifty years after the clinical introduction of total parenteral nutrition (TPN) the Arvid Wretlind lecture is an opportunity to critically analyse the evolution and changes that have marked its development and clinical use. The standard crystalline amino acid solutions, while devoid of side effects, remain incomplete regarding their composition (e.g. glutamine). Lipid emulsions have evolved tremendously and are now included in bi- and tri-compartmental feeding bags enabling a true "total" PN provided daily micronutrients are prescribed. The question of exact individual energy, macro- and micro-nutrient requirements is still unsolved. Many complications attributed to TPN are in fact the consequence of under- or over-feeding: the historical hyperalimentation concept is the main cause, along with the use of fixed weight based predictive equations (incorrect in 70% of the critically ill patients). In the late 80's many complications (hyperglycemia, sepsis, fatty liver, exacerbation of inflammation, mortality) were attributed to TPN leading to its near abandon in favour of enteral nutrition (EN). Enteral feeding, although desirable for many reasons, is difficult causing a worldwide recurrence of malnutrition by insufficient feed delivery. TPN indications have evolved towards its use either alone or in combination with EN: several controversial trials published 2011-13 have investigated TPN timing, an issue which is not yet resolved. The initiation time varies according to the country between admission (Australia and Israel), day 4 (Swiss) and day 7 (Belgium, USA). The most important issue may prove to be and individualized and time dependent prescription of feeding route, energy and substrates.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Työssä tutkittiin korkean leimahduspisteen laimentimien vaikutusta uuton tehokkuuteen ja turvallisuuteen. Kirjallisuusosa sisältää katsauksen uuttolaitoksilla tapahtuneista suuronnettomuuksista, staattisen sähkön aiheuttamista vaaroista uuttolaitoksilla ja kaupallisesti saatavista laimentimista. Lisäksi kirjallisuusosassa tarkastellaan hiilivetyjen molekyylirakenteen vaikutusta niiden leimahduspisteeseen, haihtuvuuteen, viskositeettiin ja liuotinominaisuuksiin. Kokeellisessa osassa tutkittiin uuton tehokkuutta kuvaavia ominaisuuksia, joita olivat sekoituksen pisarakoko, faasien selkeytymisnopeus,uuton ja takaisinuuton kinetiikka, orgaanisen faasin viskositeetti ja tiheys. Uuttoliuosten turvallisuusominaisuuksia tutkittiin mittaamalla synteettisten uuttoliuosten ja laimentimien leimahduspisteitä sekä sähköisesti varattujen laimentimien relaksaatioaikoja. Korkean leimahduspisteen laimentimena käytettiin Orfom SX 11-laimenninta. Vertailukohteena käytettiin Shellsol D70- ja Escaid 100- laimentimia. Malliuuttona käytettiin kuparin uuttoa hydroksioksiimireagensilla happamasta sulfaattiliuoksesta. Kokeissa havaittiin, että korkean leimahduspisteen laimentimen viskositeetti oli huomattavasti suurempi kuin Shellsol D70- laimentimella. Korkea viskositeetti hidasti faasien selkeytymistä uutossa, mutta sillä ei ollut vaikutusta uuton kinetiikkaan tai sekoituksen aiheuttamaan pisarakokoon. Uuttoliuoksen reagenssipitoisuudella havaittiin olevan vaikutusta uuttoliuoksen leimahduspisteeseen, mutta uuttoliuoksen latausasteella ei havaittu olevan vaikutusta. Sähköisesti varattujen laimentimien varauksien relaksaatioajoissa oli hieman eroja, mutta relaksaatioajat olivat kaikilla laimentimilla liian pitkiä staattisen sähkön aiheuttaman vaaran poistamiseksi.