908 resultados para Absent or reversed end-diastolic velocity


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective-To evaluate pulsed-wave Doppler spectral parameters as a method for distinguishing between neoplastic and inflammatory peripheral lymphadenopathy in dogs. Sample Population-40 superficial lymph nodes from 33 dogs with peripheral lymphadenopathy. Procedures-3 Doppler spectral tracings were recorded from each node. Spectral Doppler analysis including assessment of the resistive index, peak systolic velocity-to-end diastolic velocity (S:D) ratio, diastolic notch velocity-to-peak systolic velocity (N:S) ratio, and end diastolic velocity-to-diastolic notch velocity ratio was performed for each tracing. Several calculation methods were used to determine the Doppler indices for each lymph node. After the ultrasonographic examination, fine needle aspirates or excisional biopsy specimens of the examined lymph nodes were obtained, and lymphadenopathy was classified as either inflammatory or neoplastic (lymphomatous or metastatic) via cytologic or histologic examination. Results of Doppler analysis were compared with cytologic or histopathologic findings. Results-The Doppler index with the highest diagnostic accuracy was the S:D ratio calculated from the first recorded tracing; a cutoff value of 3.22 yielded sensitivity of 91%, specificity of 100%, and negative predictive value of 89% for detection of neoplasia. Overall diagnostic accuracy was 95%. At a sensitivity of 100%, the most accurate index was the N:S ratio calculated from the first recorded tracing; a cutoff value of 0.45 yielded specificity of 67%, positive predictive value of 81%, and overall diagnostic accuracy of 86.5%. Conclusions and Clinical Relevance-Results suggested that noninvasive Doppler spectral analysis may be useful in the diagnosis of neoplastic versus inflammatory peripheral lymphadenopathy in dogs.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: The aim of this retrospective study was to determine optimal duplex sonographic criteria for use in our institution for diagnosing severe carotid stenoses and to correlate those findings with angiographic measurements obtained by the European Carotid Surgery Trial (ECST), North American Symptomatic Carotid Endarterectomy Trial (NASCET), and Common Carotid (CC) methods of grading carotid stenoses. METHODS: We analyzed the angiographic data using the ECST, NASCET, and CC methods and compared the results with the duplex sonographic findings. We then calculated the sensitivity, specificity, positive and negative predictive values, and accuracy of the duplex sonographic method. Taking these parameters into account, the optimal intrastenotic peak systolic velocity (PSV) and end diastolic velocity (EDV) were derived for diagnosing severe stenoses according to the 3 angiographic methods. RESULTS: Optimal PSV and EDV values for diagnosing a 70% or greater stenosis in our laboratory were as follows: with the NASCET method of angiographic grading of stenoses, PSV 220 cm/second or greater and EDV 80 cm/second or greater, and with the ECST and CC methods, PSV 190 cm/second or greater, and EDV 65 cm/second or greater. The optimal PSV and EDV for diagnosing a stenosis of 80% or greater with the ECST grading method were 215 cm/second or greater and 90 cm/second or greater, respectively. CONCLUSIONS: Duplex sonography is a sensitive and accurate tool for evaluating severe carotid stenoses. Optimal PSVs and EDVs vary according to the angiographic method used to grade the stenosis. They are similar for stenoses 70% or greater with the NASCET method and for stenoses 80% or greater with the ECST method.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES Decisions to use condoms are made within partnerships. We examined the associations between inconsistent or no condom use and individual and partnership characteristics. We also examined the relative importance of individual versus partnership factors. METHODS Cross-sectional study of heterosexual individuals enrolled from the sexually transmitted infections (STI) outpatient clinic in Amsterdam, the Netherlands, from May to August 2010. Participants completed a questionnaire about sexual behaviour with the last four partners in the preceding year. Participant and partnership factors associated with inconsistent or no condom use in steady and casual partnerships were identified. RESULTS 2144 individuals were included, reporting 6401 partnerships; 54.7% were female, the median age was 25 (IQR 22-30) years and 79.9% were Dutch. Inconsistent or no condom use occurred in 13.9% of 2387 steady partnerships and in 33.5% of 4014 casual partnerships. There was statistical evidence of associations between inconsistent condom use in steady partnerships and ethnic concordance, longer duration, higher number of sex acts, practising anal sex, and sex-related drug use. In casual partnerships, associations were found with having an older partner, ethnic concordance, longer duration, higher number of sex acts, anal sex, sex-related drug use, ongoing partnerships and concurrency. In multivariable models, partnership factors explained 50.9% of the variance in steady partnerships and 70.1% in casual partnerships compared with 10.5% and 15.4% respectively for individual factors. CONCLUSIONS Among heterosexual STI clinic attendees in Amsterdam, partnership factors are more important factors related with inconsistent condom use than characteristics of the individual.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE The aim of this present study was to evaluate the sonographic correlation between Doppler flow characteristics of the uterine arteries and tumor size in patients with cervical cancer, in order to establish a new potential marker to monitor treatment response. METHODS This was a retrospective cohort study of 25 patients who underwent a sonographic evaluation of Doppler flow characteristics of the uterine arteries before surgery or radiochemotherapy for early and locally advanced/advanced cervical cancer, respectively, was analyzed. The primary outcome was the correlation between Doppler flow characteristics of the uterine arteries and tumor size in patients with cervical cancer. RESULTS Median age was 49 (range 26-85) years, and mean tumor size was 40.8 ± 17 mm. A significant positive correlation was found between tumor diameter and the uterine artery end-diastolic velocity (r = 0.47, p < 0.05) as well as the peak systolic velocity (r = 0.41, p < 0.05). No correlation was found between tumor size and the pulsatility index or resistance index. CONCLUSIONS In cervical cancer, uterine artery velocity parameters are associated with tumor size. This finding could become particularly useful in the follow-up of locally advanced cervical cancer patients undergoing radiochemotherapy or in corroborating the selection of women with more possibility of a high response rate during neoadjuvant chemotherapy before surgery.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

INTRODUCTION The appearance of end-diastolic flow velocities (EDF) in the umbilical artery (UA), usually between 10 and 14 weeks of gestation, has been associated with the opening of the spiral arteries and consequently of the intervillous space. OBJECTIVES The aim of our study was to compare first trimester UA pulsatility index (PI) and EDF between women who developed preeclampsia (cases) and controls. METHODS Our database was searched for cases who had UA Doppler between 10-14 weeks. UA PI and EDF were compared between cases and two gestational age (GA) matched controls. RESULTS 15 cases with severe preeclampsia (PE) were matched to 30 controls. GA with negative EDF was lower than with positive EDF (12.1±0.79 vs. 12.8±0.34; p=0.001). UA PI in cases was higher than in controls, although not significant (cases: 2.18±0.6 vs. CONTROLS 1.92±0.48; p=0.12). However, comparing groups with negative EDF, the difference became significant (PI cases: 2.45±0.57 vs. PI controls: 1.94±0.56; p=0.038), while no difference was found comparing groups with positive EDF. CONCLUSION First trimester UA PI is significantly higher in women which will develop PE than in controls. Interestingly, the timing of screening for PE by UA Doppler seems to play an important issue.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Carbon dioxide concentrations in the surface ocean are increasing owing to rising CO2 concentrations in the atmosphere. Higher CO2 levels are predicted to affect essential physiological processes of many aquatic organisms, leading to widespread impacts on marine diversity and ecosystem function, especially when combined with the effects of global warming. Yet the ability for marine species to adjust to increasing CO2 levels over many generations is an unresolved issue. Here we show that ocean conditions projected for the end of the century (approximately 1,000 µatm CO2 and a temperature rise of 1.5-3.0 °C) cause an increase in metabolic rate and decreases in length, weight, condition and survival of juvenile fish. However, these effects are absent or reversed when parents also experience high CO2 concentrations. Our results show that non-genetic parental effects can dramatically alter the response of marine organisms to increasing CO2 and demonstrate that some species have more capacity to acclimate to ocean acidification than previously thought.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In a communication to the Parliament and the Council entitled “Towards a modern, more European copyright framework” and dated 9 December 2015,1 the European Commission confirmed its intention to progressively remove the main obstacles to the functioning of the Digital Single Market for copyrighted works. The first step of this long-term plan, which was first announced in Juncker’s Political Guidelines2 and the Communication on “A Digital Single Market strategy for Europe”,3 is a proposal for a regulation aimed at ensuring the so-called ‘cross-border portability’ of online services giving access to content such as music, games, films and sporting events.4 In a nutshell, the proposed regulation seeks to enable consumers with legal access to such online content services in their country of residence to use the same services also when they are in another member state for a limited period of time. On the one hand, this legislative proposal has the full potential to resolve the (limited) issue of portability, which stems from the national dimension of copyright and the persisting territorial licensing and distribution of copyright content.5 On the other hand, as this commentary shows, the ambiguity of certain important provisions in the proposed regulation might affect its scope and effectiveness and contribute to the erosion of the principle of copyright territoriality.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background. To evaluate the haemodynamic features of young healthy myopes and emmetropes, in order to ascertain the perfusion profile of human myopia and its relationship with axial length prior to reaching a degenerative state. Methods The retrobulbar, microretinal and pulsatile ocular blood flow (POBF) of one eye of each of twenty-two high myopes (N=22, mean spherical equivalent (MSE) =-5.00D), low myopes (N=22, MSE-1.00 to-4.50D) and emmetropes (N=22, MSE±0.50D) was analyzed using color Doppler Imaging, Heidelberg retinal flowmetry and ocular blood flow analyser (OBF) respectively. Intraocular pressure, axial length (AL), systemic blood pressure, and body mass index were measured. Results. When compared to the emmetropes and low myopes, the AL was greater in high myopia (p<0.0001). High myopes showed higher central retinal artery resistance index (CRA RI) (p=0.004), higher peak systolic to end diastolic velocities ratio (CRA ratio) and lower end diastolic velocity (CRA EDv) compared to low myopes (p=0.014, p=0.037). Compared to emmetropes, high myopes showed lower OBFamplitude (OBFa) (p=0.016). The POBF correlated significantly with the systolic and diastolic blood velocities of the CRA (p=0.016, p=0.036). MSE and AL correlated negatively with OBFa (p=0.03, p=0.003), OBF volume (p=0.02, p<0.001), POBF (p=0.01, p<0.001) and positively with CRA RI (p=0.007, p=0.05). Conclusion. High myopes exhibited significantly reduced pulse amplitude and CRA blood velocity, the first of which may be due to an OBF measurement artefact or real decreased ocular blood flow pulsatility. Axial length and refractive error correlated moderately with the ocular pulse and with the resistance index of the CRA, which in turn correlated amongst themselves. It is hypothesized that the compromised pulsatile and CRA haemodynamics observed in young healthy myopes is an early feature of the decrease in ocular blood flow reported in pathological myopia. Such vascular features would increase the susceptibility for vascular and age-related eye diseases.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: To evaluate the relationship between ocular perfusion pressure and color Doppler measurements in patients with glaucoma. MATERIALS AND METHODS: Twenty patients with primary open-angle glaucoma with visual field deterioration in spite of an intraocular pressure lowered below 21 mm Hg, 20 age-matched patients with glaucoma with stable visual fields, and 20 age-matched healthy controls were recruited. After a 20-minute rest in a supine position, intraocular pressure and color Doppler measurements parameters of the ophthalmic artery and the central retinal artery were obtained. Correlations between mean ocular perfusion pressure and color Doppler measurements parameters were determined. RESULTS: Patients with glaucoma showed a higher intraocular pressure (P <.0008) and a lower mean ocular perfusion pressure (P <.0045) compared with healthy subjects. Patients with deteriorating glaucoma showed a lower mean blood pressure (P =.033) and a lower end diastolic velocity in the central retinal artery (P =.0093) compared with normals. Mean ocular perfusion pressure correlated positively with end diastolic velocity in the ophthalmic artery (R = 0.66, P =.002) and central retinal artery (R = 0.74, P <.0001) and negatively with resistivity index in the ophthalmic artery (R = -0.70, P =.001) and central retinal artery (R = -0.62, P =.003) in patients with deteriorating glaucoma. Such correlations did not occur in patients with glaucoma with stable visual fields or in normal subjects. The correlations were statistically significantly different between the study groups (parallelism of regression lines in an analysis of covariance model) for end diastolic velocity (P =.001) and resistivity index (P =.0001) in the ophthalmic artery, as well as for end diastolic velocity (P =.0009) and resistivity index (P =. 001) in the central retinal artery. CONCLUSIONS: The present findings suggest that alterations in ocular blood flow regulation may contribute to the progression in glaucomatous damage.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective - The purpose of this study was to assess cardiac function and cell damage in intrauterine growth-restricted (IUGR) fetuses across clinical Doppler stages of deterioration. Study Design - One hundred twenty appropriate-for-gestational-age and 81 IUGR fetuses were classified in stages 1/2/3 according umbilical artery present/absent/reversed end-diastolic blood flow, respectively. Cardiac function was assessed by modified-myocardial performance index, early-to-late diastolic filling ratios, cardiac output, and cord blood B-type natriuretic peptide; myocardial cell damage was assessed by heart fatty acid–binding protein, troponin-I, and high-sensitivity C-reactive protein. Results - Modified-myocardial performance index, blood B-type natriuretic peptide, and early-to-late diastolic filling ratios were increased in a stage-dependent manner in IUGR fetuses, compared with appropriate-for-gestational-age fetuses. Heart fatty acid–binding protein levels were higher in IUGR fetuses at stage 3, compared with control fetuses. Cardiac output, troponin-I, and high-sensitivity C-reactive protein did not increase in IUGR fetuses at any stage. Conclusion - IUGR fetuses showed signs of cardiac dysfunction from early stages. Cardiac dysfunction deteriorates further with the progression of fetal compromise, together with the appearance of biochemical signs of cell damage.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To analyze the effects of 100 mg of sildenafil citrate (Viagra®) on the retrobulbar circulation and visual field. Methods: A double masked, placebo controlled study was conducted in 10 males with a mean age of 27.7 + 5.68 years. The right eye of each volunteer underwent orbital color Doppler imaging and automated perimetry (Humphrey, program 30-2, Full-Threshold Strategy) at 3 occasions: baseline, 1 hour after placebo and 1 hour after 100 mg of sildenafil. The foveal threshold and the mean deviation (MD) were analyzed by automated perimetry on the three occasions. Color Doppler imaging allowed the measurement of the peak systolic velocity (PSV), end diastolic velocity (EDV) and Pourcelot index (PI) in the central retinal artery and ophthalmic artery. Results: The foveal threshold and the mean deviation did not show a significant change following the administration of sildenafil. The ophthalmic artery peak systolic velocity and end diastolic velocity significantly increased after the administration of sildenafil (p<0.001). The hemodynamic parameters in the central retinal artery and the ophthalmic artery PI did not significantly change. Conclusions: Sildefanil citrate increased the blood flow velocities in the ophthalmic artery in normal subjects, with no significant changes in the foveal threshold and mean deviation in the automated perimetry.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives: To evaluate the intratumoral reliability of color Doppler parameters and the contribution of Doppler sonography to the gray-scale differential diagnosis of ovarian masses. Methods: An observational study was performed including 67 patients, 15 (22.4%) with malignant ovarian neoplasm and 52 (77.6%) with benign ovarian diseases. We performed the Doppler evaluation in two distinct vessels selected after decreasing the Doppler gain to sample only vessels with higher velocity flow. Doppler measurements were obtained from each identified vessel, and resistive index (RI), pulsatility index (PI), peak systolic velocity (PSV), and end-diastolic velocity (EDV) were measured. Intraclass coefficient of correlation (ICC), sensitivity, specificity, and potential improvement in gray-scale ultrasound performance were calculated. Results: The general ICC were 0.60 (95% CI 0.42- 0.73) for RI, 0.65 (95% CI 0.49- 0.77) for PI, 0.07 (95% CI- 0.17-0.30) for PSV, and 0.19 (95% CI -0.05-0.41) for EDV. The sensitivity and specificity were respectively 84.6% and 86.7% for RI, 69.2% and 93.3% for PI, 80.0% and 65.4% for gray-scale sonography, and 93.3% and 65.4% for gray-scale plus RI (p = 0.013). Conclusions: Gynecologists must be careful in interpreting results from Doppler evaluation of ovarian masses because PSV and EDV present poor intratumoral reliability. The lower RI value, evaluated in at least two distinct sites of the tumor, was able to improve the performance of gray-scale ultrasound in differential diagnosis of ovarian masses.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study aimed to assess whether there are differences in Doppler velocimetry parameters between different sizes. Twenty dogs were equally divided into small and large groups used in this study. The dogs were evaluated using Triplex ultrasound. Testicular artery was located by Colour Doppler in the spermatic cord, marginal to the testes and intratesticular segments and then, spectral Doppler were used to calculate: peak systolic velocity (PSV), end diastolic velocity (EDV), resistance index (RI) and pulsatility index (PI). The mean testicular volume in the left side was significantly higher than the right side, in both groups. Doppler examination showed higher velocities (EDV) at spermatic cord in large dogs; marginal to the testes was observed higher velocities in small dogs; intratesticular region no differences were observed (P < 0.05) and within the groups differences between segments of the artery were also observed for each parameter. The results showed that there are differences in Doppler velocimetry parameters between different sizes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Perception of our own bodies is based on integration of visual and tactile inputs, notably by neurons in the brain’s parietal lobes. Here we report a behavioural consequence of this integration process. Simply viewing the arm can speed up reactions to an invisible tactile stimulus on the arm. We observed this visual enhancement effect only when a tactile task required spatial computation within a topographic map of the body surface and the judgements made were close to the limits of performance. This effect of viewing the body surface was absent or reversed in tasks that either did not require a spatial computation or in which judgements were well above performance limits. We consider possible mechanisms by which vision may influence tactile processing.