978 resultados para ARRAY DETECTION


Relevância:

60.00% 60.00%

Publicador:

Resumo:

A pre-column derivatization method for sensitive determination of oligopeptides, using the tagging reagent 2-(9-carbazole)ethyl chloroformate (CEOC-Cl) followed by capillary electrophoresis (CE) with diode-array detection, has been developed. Maximum yield close to 100% were observed when a three to fourfold molar excess of reagent was used at pH 9.0-10.0. Excess reagent was extracted with n-hexane-ethyl acetate 9:1-10:1 (v/v); this enabled direct analysis using CE with no significant disturbance from the major fluorescent reagent degradation by-products. The effects on the results of buffer pH and of SDS and organic modifier concentrations were examined. Good baseline resolution in the separation of five CEOC-peptides was achieved with a 48.5-cm total length (effective length 40 cm) 50-mu m inner diameter capillary column.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A sensitive and specific reversed-phase high performance liquid chromatography (RP-HPLC) method with diode array detection (DAD) was established for the quantitative determination of the nine active components, namely, swertiamarin (SWM, 1), mangiferin (MA, 2), gentipicroside (GE, 3), sweroside (SWO, 4), isoorientin (IS, 5), swertisin (SWS, 6), swertianolin (SWN, 7), 7-O-[alpha-L-rhamnopyranosyl-1 -> 2)-beta-D-xylopyranosyl]-1,8-dihydroxy-3-methoxyxanthone (RX, 8), and bellidifolin (BE, 9) used as the external standard, in Tibetan folk medicinal species Swertia franchetiana. Based on the baseline chromatographic separation of most components from the methanolic extract of Swertia franchetiana on a reversed-phase Eclipse XDB-C8 column with water-acetonitrile-formic acid as mobile phase, the nine components were identified by comparison with standard samples and qualified by using the external standard method with DAD at 254 nm. The correlation coefficients of all the calibration curves were found to be higher than 0.9980. The relative standard deviations (RSDs) of the peak areas and retention times for the nine standards were less than 2.07% and 2.86%, respectively.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This paper describes the simultaneous determination of allantoin, quercetin, and 1-methyl-1,2,3,4-tetrahydro-beta-carboline-3-carboxylic acid (MTCCA) in Nitraria tangutorum Bobr seed by HPLC-APCI-MS and CE (capillary electrophoresis) methods. The final optimized chromatographic conditions were investigated in a reversed-phase Eclipse XDB-C8 column (150 x 4.6 mm, 5 mu m). A seventeen-minute gradient elution, (A: aqueous acetonitrile 20% (v/v); B: aqueous acetonitrile 60% (v/v); C: pure acetonitrile 100%) at a flow rate of 1.0 mL/min was selected for the separation of three natural products with diode array detection (DAD) at 220 nm. A CE experiment was carried out in a fused silica capillary with 32 mmol/L boric acid (pH 10), 32 mmol/L SDS and acetonitrile (10.0%, v/v). The applied potential and temperature was, respectively, set at 19 kV and 25 degrees C. After development, the validation was performed in parallel for HPLC and CE, with the same standards and sample to avoid differences due to the manipulation. The validation parameters of both techniques were adequate for the intended purpose.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The major components of the plant curcuma longa are the curcuminoids that include curcumin, demethoxycurcumin and bisdemethoxycurcumin. It has been reported the curcuminoids have some important activities. A new CZE method with diode array detection has been developed for the separation and determination of the curcumin, demethoxycurcumin and bisdemethoxycurcumin. Three curcuminoids could be readily separated within 7 min with a 15 mM sodium tetraborate buffer containing 10% methanol (v/v) at pH 10.8, 25 kV and 30 degrees C. The method has been validated and shows good performance with respect to selectivity, reproducibility, linearity, limits of detection and recovery. The proposed method was successfully applied to determine the curcuminoids in urine. (c) 2004 Elsevier B.V. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Langstaff, David; Bushell, A.; Chase, T.; Evans, D.A., (2005) 'A fully integrated multi-channel detector for electron spectroscopy', Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms 238 pp.219-223 RAE2008 Synchrotron Radiation in Materials Science ? Proceedings of the 4th Conference on Synchrotron Radiation in Materials Science 4th Conference on Synchrotron Radiation in Materials Science

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Of novel sedimentary transformation products of bacteriochlorophyll a, 7,8-didehydro derivatives (Bacterioviridins), has been identified using high performance liquid chromatography with photodiode array detection and atmospheric pressure chemical ionisation liquid chromatography-multistage mass spectrometry. The derivatives occur in a range of sediments including Priest Pot (UK), les Salines de la Trinital, Ebre delta (Spain), Sutton-on-the-Forest (UK) and Certes (France). The Bacterioviridins are products of oxidative transformation of bacteriochlorophyll a, and their presence in sediments indicates exposure of the bacterial community to oxygen.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objective: The aim was to investigate the association between periodontal health and the serum levels of various antioxidants including carotenoids, retinol and vitamin E in a homogenous group of Western European men.
Materials and Methods: A representative sample of 1258 men aged 60-70 years, drawn from the population of Northern Ireland, was examined between 2001 and 2003. Each participant had six or more teeth, completed a questionnaire and underwent a clinical periodontal examination. Serum lipid-soluble antioxidant levels were measured by high-performance liquid chromatography with diode array detection. Multivariable analysis was carried out using logistic regression with adjustment for possible confounders. Models were constructed using two measures of periodontal status (low- and high-threshold periodontitis) as dependent variables and the fifths of each antioxidant as a predictor variable.
Results: The levels of a- and ß-carotene, ß-cryptoxanthin and zeaxanthin were highly significantly lower in the men with low-threshold periodontitis (p<0.001). These carotenoids were also significantly lower in high-threshold periodontitis. There were no significant differences in the levels of lutein, lycopene, a- and ?-tocopherol or retinol in relation to periodontitis. In fully adjusted models, there was an inverse relationship between a number of carotenoids (a- and ß-carotene and ß-cryptoxanthin) and low-threshold periodontitis. ß-Carotene and ß-cryptoxanthin were the only antioxidants that were associated with an increased risk of high-threshold severe periodontitis. The adjusted odds ratio for high-threshold periodontitis in the lowest fifth relative to the highest fifth of ß-cryptoxanthin was 4.02 (p=0.003).
Conclusion: It is concluded that low serum levels of a number of carotenoids, in particular beta-cryptoxanthin and beta-carotene, were associated with an increased prevalence of periodontitis in this homogenous group of 60-70-year-old Western European men.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Assessment of Human papillomavirus (HPV) prevalence and genotype distribution is important for monitoring the impact of prophylactic HPV vaccination. This study aimed to demonstrate the HPV genotypes predominating in pre-malignant and cervical cancers in Northern Ireland (NI) before the vaccination campaign has effect. Formalin fixed paraffin embedded tissue blocks from 2,303 women aged 16-93 years throughout NI were collated between April 2011 and February 2013. HPV DNA was amplified by PCR and HPV genotyping undertaken using the Roche® linear array detection kit. In total, 1,241 out of 1,830 eligible samples (68.0%) tested positive for HPV, with the majority of these [1,181/1,830 (64.5%)] having high-risk (HR) HPV infection; 37.4% were positive for HPV-16 (n=684) and 5.1% for HPV-18 (n=93). HPV type-specific prevalence was 48.1%, 65.9%, 81.3%, 92.2%, and 64.3% among cervical intraepithelial neoplasias (CIN) Grades I-III, squamous cell carcinomas (SCC) and adenocarcinoma (AC) cases, respectively. Most SCC cases (81.3%) had only one HPV genotype detected and almost a third (32.0%) of all cervical pathologies were HPV negative including 51.9% of CIN I (n=283), 34.1% CIN II (n=145), 18.7% of CIN III (n=146), 7.8% of SCC (n=5), and 35.7% of AC (n=5) cases. This study provides important baseline data for monitoring the effect of HPV vaccination in NI and for comparison with other UK regions. The coverage of other HR-HPV genotypes apart from 16 and 18, including HPV-45, 31, 39, and 52, and the potential for cross protection, should be considered when considering future polyvalent vaccines.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This study investigated and characterised transdermal permeation of bioactive agents from a topically applied Arnica montana tincture. Permeation experiments conducted over 48 h used polydimethylsiloxane (silastic) and human epidermal membranes mounted in Franz-type diffusion cells with a methanol-water (50:50 v/v) receptor fluid. A commercially available tincture of A. montana L. derived from dried Spanish flower heads was a donor solution. Further donor solutions prepared from this stock tincture concentrated the tincture constituents 1, 2 and 10 fold and its sesquiterpene lactones 10 fold. Permeants were assayed using a high-performance liquid chromatography method. Five components permeated through silastic membranes providing peaks with relative retention factors to an internal standard (santonin) of 0.28, 1.18, 1.45, 1.98 and 2.76, respectively. No permeant was detected within 12 h of applying the Arnica tincture onto human epidermal membranes. However, after 12 h, the first two of these components were detected. These were shown by Zimmermann reagent reaction to be sesquiterpene lactones and liquid chromatography/diode array detection/mass spectrometry indicated that these two permeants were 11,13-dihydrohelenalin (DH) analogues (methacrylate and tiglate esters). The same two components were also detected within 3 h of topical application of the 10-fold concentrated tincture and the concentrated sesquiterpene lactone extract.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Paracetamol is among the most worldwide consumed pharmaceuticals. Although its occurrence in the environment is well documented, data about the presence of its metabolites and transformation products is very scarce. The present work describes the development of an analytical method for the simultaneous determination of paracetamol, its principal metabolite (paracetamol-glucuronide) and its main transformation product (p-aminophenol) based on solid phase extraction (SPE) and high performance liquid chromatography coupled to diode array detection (HPLC-DAD). The method was applied to analysis of river waters, showing to be suitable to be used in routine analysis. Different SPE sorbents were compared and the use of two Oasis WAX cartridges in tandem proved to be the most adequate approach for sample clean up and pre-concentration. Under optimized conditions, limits of detection in the range 40–67 ng/L were obtained, as well as mean recoveries between 60 and 110% with relative standard deviations (RSD) below 6%. Finally, the developed SPE-HPLC/DAD method was successfully applied to the analysis of the selected compounds in samples from seven rivers located in the north of Portugal. Nevertheless all the compounds were detected, it was the first time that paracetamol-glucuronide was found in river water at concentrations up to 3.57 μg/L.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Surface flavonoids in nine species of Origanum, representing taxa from all three of the currently recognised subgeneric groups, were examined both by HPLC coupled to diode-array detection and APCI-MS. Many of the flavonoids present were characterised by O-substituent at C-6 (OH, OMe) and/or C-8 (OMe). In total, 25 flavones and flavanones are described in this study, of which 13 are new to the genus and 5,4'-dihydroxy-6,7,3'-trimethoxyflavanone is reported for the first time. Taxa in subgeneric Group A accumulated flavonoids with methoxyl groups at both C-6 and C-4'; however, taxa in subgeneric Group B did not accumulate 4'-methoxylated compounds, and taxa in Group C did not accumulate 6-methoxylated compounds. (C) 2008 Elsevier Ltd. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This study investigated and characterised transdermal permeation of bioactive agents from a topically applied Arnica montana tincture. Permeation experiments conducted over 48 h used polyclimethylsiloxane (silastic) and human epidermal membranes mounted in Franz-type diffusion cells with a methanol-water (50:50 v/v) receptor fluid. A commercially available tincture of A. montana L. derived from dried Spanish flower heads was a donor solution. Further donor solutions prepared from this stock tincture concentrated the tincture constituents 1, 2 and 10 fold and its sesquiterpene lactones 10 fold. Permeants were assayed using a high-performance liquid chromatography method. Five components permeated through silastic membranes providing peaks with relative retention factors to an internal standard (santonin) of 0.28, 1.18, 1.45, 1.98 and 2.76, respectively. No permeant was detected within 12 h of applying the Arnica tincture onto human epidermal membranes. However, after 12 h, the first two of these components were detected. These were,shown by Zimmermann reagent reaction to be sesquiterpene lactones and liquid chromatography/diode array detection/mass spectrometry indicated that these two permeants were 11,13-dihydrohelenalin (DH) analogues (methacrylate and tiglate esters). The same two components were also detected within 3 h of topical application of the 10-fold concentrated tincture and the concentrated sesquiterpene lactone extract.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND: Chloroform, ethyl acetate and methanol extracts of a sample of red propolis from the state of Alagoas (northeast Brazil) were analyzed by gas chromatography-mass spectrometry and high-performance liquid chromatography-diode array detection-electrospray ionization-mass spectrometry. Antimicrobial and antioxidant activities were also obtained. RESULTS: The propolis sample contained low content of narigenin-8-C-hexoside, this being the first report of a C-glycoside in propolis. The main constituent found was characterized as 3,4,2`,3`-tetrahydroxychalcone. Other important constituents were the chalcone isoliquiritigenin, the isoflavans (3S)-vestitol, (3S)-7-O-methylvestitol, the pterocarpan medicarpin, the phenylpropenes trans-anethol, methyl eugenol, elimicin, methoxyeugenol and cis-asarone, and the triterpenic alcohols lupeol and alpha- and beta- amyrins. The methanol extract exhibited high antioxidant activities by 2,2-diphenyl-1-picrylhydrazyl and beta-carotene/linoleic acid assay methods, and antimicrobial activity toward Gram-positive and Gram-negative bacteria. CONCLUSION: Structures are suggested for new substances never before seen in any kind of propolis. This is the first report of 3,4,2`,3`-tetrahydroxychalcone and a flavone C-glycoside in a propolis sample. (C) 2011 Society of Chemical Industry

Relevância:

60.00% 60.00%

Publicador:

Resumo:

in this work, a simple method for the simultaneous determination of cocaine (COC) and five COC metabolites (benzoylecgonine, cocaethylene (CET), anhydroecgonine, anhydroecgonine methyl ester and ecgonine methyl ester) in human urine using CE coupled to MS via electrospray ionization (CE-ESI-MS) was developed and validated. Formic acid at 1 mol/L concentration was used as electrolyte whereas formic acid at 0.05 mol/L concentration in 1:1 methanol:water composed the coaxial sheath liquid at the ESI nozzle. The developed method presented good linearity in the dynamic range from 250 ng/mL to 5000 ng/mL (coefficient of determination greater than 0.98 for all compounds). LODs (signal-to-noise ratio of 3) were 100 ng/mL for COC and CET and 250 ng/mL for the other studied metabolites whereas LOQ`s (signal-to-noise ratio of 10) were 250 ng/mL for COC and CET and 500 ng/mL for all other compounds. Intra-day precision and recovery tests estimated at three different concentration levels (500, 1500 and 5000 ng/mL) provided RSD lower than 10% (except anhydroecgonine, 18% RSD) and recoveries from 83-109% for all analytes. The method was successfully applied to real cases. For the positive urine samples, the presence of COC and its` metabolites was further confirmed by MS/MS experiments.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A column switching LC method is presented for the analysis of fluoxetine (FLU) and norfluoxetine (NFLU) by direct injection of human plasma using a lab-made restricted access media (RAM) column. A RAM-BSA-octadecyl silica (C-18) column (40 min x 4.6 mm, 10 mu m) is evaluated in both backflush and foreflush elution modes and coupled with a C-18 lab-made (50 mm x 4.6 mm, 3 pm) analytical column in order to perform online sample preparation. Direct injection of 100 mu L, of plasma samples is possible with the developed approach. In addition, reduction of sample handling is obtained when compared with traditional liquid-liquid extraction (LLE) and SPE. The total analysis time is around 20 min. A LOQ of 15 ng/mL is achieved in a concentration range of 15-500 ng/mL, allowing the therapeutic drug monitoring of clinical samples. The precision values achieved are lower than 15% for all the evaluated points with adequate recovery and accuracy. Furthermore, no matrix interferences are found in the analysis and the proposed method shows to be an adequate alternative for analysis of FLU in plasma.