996 resultados para APICAL FORAMEN


Relevância:

70.00% 70.00%

Publicador:

Resumo:

Pós-graduação em Odontologia Restauradora - ICT

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The aim of this study was to assess, in vivo, the accuracy of the NovApex (R) electronic foramen locator in determining working length (WL) in vital and necrotic posterior teeth. The NovApex (R) was used in 144 canals: 35 teeth with vital pulps (68 canals) and 42 teeth with necrotic pulps (76 canals). WL was measured with the NovApex (R) locator and confirmed using the radiographic method. Differences between electronic and radiographic measurements ranging between 0.0 and 0.4 millimeters were classified as acceptable; differences equal to or greater than 0.5 millimeter were considered unacceptable. Pearson's chi-square test was used to assess the influence of pulp condition on the accuracy of NovApex (R) (alpha = 0.05). Regardless of pulp condition, differences between electronic and radiographic WL measurements were acceptable in 73.61% of the canals. No statistically significant differences in accuracy were observed when comparing vital and necrotic canals (p > 0.05). There were 38 unacceptable measurements. In none of these cases was the file tip located beyond the radiographic apex; in 32, it was located short of the NovApex (R) measurement. Pulp condition had no significant effect on the accuracy of NovApex (R).

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Objective: The aim of this study was to evaluate, ex vivo, the precision of five electronic root canal length measurement devices (ERCLMDs) with different operating systems: the Root ZX, Mini Apex Locator, Propex II, iPex, and RomiApex A-15, and the possible influence of the positioning of the instrument tips short of the apical foramen. Material and Methods: Forty-two mandibular bicuspids had their real canal lengths (RL) previously determined. Electronic measurements were performed 1.0 mm short of the apical foramen (-1.0), followed by measurements at the apical foramen (0.0). The data resulting from the comparison of the ERCLMD measurements and the RL were evaluated by the Wilcoxon and Friedman tests at a significance level of 5%. Results: Considering the measurements performed at 0.0 and -1.0, the precision rates for the ERCLMDs were: 73.5% and 47.1% (Root ZX), 73.5% and 55.9% (Mini Apex Locator), 67.6% and 41.1% (Propex II), 61.7% and 44.1% (iPex), and 79.4% and 44.1% (RomiApex A-15), respectively, considering ±0.5 mm of tolerance. Regarding the mean discrepancies, no differences were observed at 0.0; however, in the measurements at -1.0, the iPex, a multi-frequency ERCLMD, had significantly more discrepant readings short of the apical foramen than the other devices, except for the Propex II, which had intermediate results. When the ERCLMDs measurements at -1.0 were compared with those at 0.0, the Propex II, iPex and RomiApex A-15 presented significantly higher discrepancies in their readings. Conclusions: Under the conditions of the present study, all the ERCLMDs provided acceptable measurements at the 0.0 position. However, at the -1.0 position, the ERCLMDs had a lower precision, with statistically significant differences for the Propex II, iPex, and RomiApex A-15.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Besides the risk of filling material extrusion throughout the apex, a satisfactory apical seal can be difficult to achieve in canals with open apices or iatrogenic enlargements of the apical constriction. These situations pose a challenge to root canal filling. This paper describes the root canal filling of a maxillary right canine with an overinstrumented apex, complete loss of the apical stop, extensive canal transportation and apical periodontitis. A 5 mm calcium hydroxide apical plug was placed before root canal filling. The plug was made by soaking paper points with saline, dipping the points in calcium hydroxide powder and then applying it to the apex several times, until a consistent apical plug was obtained. The canal was then irrigated with saline in order to remove any residual calcium hydroxide from the root canal walls, dried with paper points and obturated with an inverted #80 gutta-percha cone and zinc oxide-eugenol based sealer by the lateral condensation technique. An 8-year radiographic follow-up showed formation of mineralized tissue sealing the apical foramen, apical remodeling and no signs of apical periodontitis.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The present study compared the accuracy of three electronic apex locators (EALs) - Elements Diagnostic®, Root ZX® and Apex DSP® - in the presence of different irrigating solutions (0.9% saline solution and 1% sodium hypochlorite). The electronic measurements were carried out by three examiners, using twenty extracted human permanent maxillary central incisors. A size 10 K file was introduced into the root canals until reaching the 0.0 mark, and was subsequently retracted to the 1.0 mark. The gold standard (GS) measurement was obtained by combining visual and radiographic methods, and was set 1 mm short of the apical foramen. Electronic length values closer to the GS (± 0.5 mm) were considered as accurate measures. Intraclass correlation coefficients (ICCs) were used to verify inter-examiner agreement. The comparison among the EALs was performed using the McNemar and Kruskal-Wallis tests (p < 0.05). The ICCs were generally high, ranging from 0.8859 to 0.9657. Similar results were observed for the percentage of electronic measurements closer to the GS obtained with the Elements Diagnostic® and the Root ZX® EALs (p > 0.05), independent of the irrigating solutions used. The measurements taken with these two EALs were more accurate than those taken with Apex DSP®, regardless of the irrigating solution used (p < 0.05). It was concluded that Elements Diagnostic® and Root ZX® apex locators are able to locate the cementum-dentine junction more precisely than Apex DSP®. The presence of irrigating solutions does not interfere with the performance of the EALs.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objective. In this study, presence of dentin infection in root canals, obturated with 4 techniques submitted to the bacterial leakage test, was evaluated using histologic methods. Study design. The canals of palatal roots of 160 molars were instrumented and divided into different groups, according to the obturation technique used (lateral condensation, MicroSeal system, Touch `n Heat + Ultrafil, and Tagger`s hybrid technique) and extent of the remaining obturation material (5 mm and 10 mm). Ten additional roots were used as control samples. The roots were sterilized in ethylene oxide and mounted on a device for evaluation of bacterial leakage using the bacteria Enterococcus faecalis for 120 days. After the leakage test, roots were microscopically analyzed for the presence of dentin infection in the root canals and dentinal tubules. Results. A total of 154 specimens were analyzed using both methodologies in the experimental groups; 50 root canals (32.4%) showed bacterial leakage at the end of the experimental period, and 118 (76.6%) showed the presence of bacteria in the root canals using the histologic criteria. The lateral condensation technique allowed lower penetration of bacteria in the root canals and dentinal tubules, followed by Touch `n Heat + Ultrafil, MicroSeal, and Tagger`s hybrid technique, which allowed significantly greater penetration of bacteria. Root canals with 10 mm of remaining obturation material presented similar bacterial penetration as root canals with 5 mm. Conclusions. Even when an adequate seal of the apical foramen was shown by the absence of turbidity in the bacterial leakage test, E. faecalis dentin infection was present in a high percentage of the root canals after 120 days of root filling exposure to the bacteria. Tagger`s hybrid technique presented greater quantity of bacteria in histologic sections than root canals obturated with the other techniques. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2010; 109: 788-794)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

P>Aim To investigate the internal and external anatomy of extracted human mandibular canines with two roots and two distinct canals using micro-computed tomography (mu CT). Methodology Fourteen two-rooted human mandibular canines were scanned using a high-resolution mu CT system (SkyScan 1174v2; SkyScan N.V., Kontich, Belgium). The images were processed to evaluate the size of the roots, the furcation regions, the presence of accessory canals, the mean distances between several anatomical landmarks, the position of the apical foramina, the direction of root curvatures, the cross-sectional appearances (SMI index), the volume and surface areas of the root canals. Results Root bifurcation was located in both apical (44%, n = 6) and middle (58%, n = 8) thirds of the root. The size of the buccal and lingual roots was similar in 29% of the sample. From a buccal view, no curvature towards the lingual or buccal direction occurred in either roots. From a proximal view, no straight lingual root occurred. In both views, S-shaped roots were found in 21% of the specimens. Location of the apical foramen varied considerably, tending to the mesio-buccal aspect of both roots. Lateral and furcation canals were observed mostly in the cervical third in 29% and 65% of the sample, respectively. The structure model index (SMI) index ranged from 1.87 to 3.86, with a mean value of 2.93 +/- 0.46. Mean volume and area of the root canals were 11.52 +/- 3.44 mm3 and 71.16 +/- 11.83 mm2, respectively. Conclusions The evaluation of two-rooted mandibular canines revealed that bifurcations occurred in the apical and middle third. S-shaped roots were found in 21% of the specimens. Mean volume, surface area and SMI index of the root canals were 11.52 mm3, 71.16 mm2 and 2.93, respectively.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The purpose of this study was to evaluate ex vivo the accuracy an electronic apex locator during root canal length determination in primary molars. Methods: One calibrated examiner determined the root canal length in 15 primary molars (total=34 root canals) with different stages of root resorption. Root canal length was measured both visually, with the placement of a K-file 1 mm short of the apical foramen or the apical resorption bevel, and electronically using an electronic apex locator (Digital Signal Processing). Data were analyzed statistically using the intraclass correlation (ICC) test. Results: Comparing the actual and electronic root canal length measurements in the primary teeth showed a high correlation (ICC=0.95) Conclusions: The Digital Signal Processing apex locator is useful and accurate for apex foramen location during root canal length measurement in primary molars. (Pediatr Dent 200937:320-2) Received April 75, 2008 vertical bar Lost Revision August 21, 2008 vertical bar Revision Accepted August 22, 2008

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Aim To evaluate ex vivo the accuracy of two electronic apex locators during root canal length determination in primary incisor and molar teeth with different stages of physiological root resorption. Methodology One calibrated examiner determined the root canal length in 17 primary incisors and 16 primary molars (total of 57 root canals) with different stages of root resorption based on the actual canal length and using two electronic apex locators. Root canal length was measured both visually, with the placement of a K-file 1 mm short of the apical foramen or the apical resorption bevel, and electronically using two electronic apex locators (Root ZX II - J. Morita Corp. and Mini Apex Locator - SybronEndo) according to the manufacturers` instructions. Data were analysed statistically using the intraclass correlation (ICC) test. Results Comparison of the actual root canal length and the electronic root canal length measurements revealed high correlation (ICC = 0.99), regardless of the tooth type (single-rooted and multi-rooted teeth) or the presence/absence of physiological root resorption. Conclusions Root ZX II and Mini Apex Locator proved useful and accurate for apex foramen location during root canal length measurement in primary incisors and molars.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

P>Aim To evaluate ex vivo the accuracy of the iPex multi-frequency electronic apex locator (NSK Ltd, Tokyo, Japan) for working length determination in primary molar teeth. Methodology One calibrated examiner determined the working length in 20 primary molar teeth (total of 33 root canals). Working length was measured both visually, with the placement of a K-file 1 mm short of the apical foramen or the most coronal limit of root resorption, and electronically using the electronic apex locator iPex, according to the manufacturers` instructions. Data were analysed statistically using the intraclass correlation (ICC) test. Results Comparison of the actual and the electronic measurements revealed high correlation (ICC = 0.99) between the methods, regardless of the presence or absence of physiological root resorption. Conclusions In this laboratory study, the iPex accurately identified the apical foramen or the apical opening location for working length measurement in primary molar teeth.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objective: the ability of the laser irradiation to promote the cleaning and disinfection of the radicular canal system has become this type of treatment in a viable and real alternative in endodontics. The purpose of this study was to evaluate the apical marginal sealing of root canal fillings after the irradiation with the laser of Nd:YAG or of Er:YAG. Materials and Methods: Forty-two human, extracted single-rooted teeth had their crowns sectioned and the root canals prepared with a no. 70 K-file. Then, they were dried and divided into three groups according to canal wall treatment: group 1: the canals were filled with EDTA for 3 min, followed by irrigation with 1% sodium hypochlorite solution; group 2: the canal walls were irradiated with Nd:YAG laser; and group 3: the canal walls were irradiated with Er:YAG laser. Afterwards, the root canals were obturated by the lateral condensation technique. The roots were externally waterproof, except in the apical foramen and immerged in 2% methylene blue aqueous solution during 48 hours. Results: the results showed that the largest infiltrations happened in the group 3-Er:YAG (7.3 mm), proceeded by the group 1-EDTA (1.6 mm) and by the group 2-Nd:YAG (0.6 mm). The group Er:YAG differed statistically of the others (p < 0.05). Conclusion: It was concluded that the Er:YAG laser intracanal irradiation previously to the root canal filling must be used with caution until future research is define the best parameters for it's use.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The aim of this study was to evaluate the effect of 1% sodium hypochlorite and five intracanals medications on Candida albicans harvested inside root canals. The contaminated canals were irrigated with sterile saline solution and then treated as follows: (i) filled with Calen paste (calcium hydroxide/glycol polyethylene paste); (ii) filled with camphorated paramonochloro phenol (CPMC); (iii) filled with 2% iodine-iodate solution; (iv) filled with tricresol formalin; (v) filled with Calen and CPMC pastes; (vi) irrigation with 1% sodium hypochlorite and filled with no intracanal medication; and (vii) no intracanal medication was used. Canal access and the apical foramen were then sealed with Cavit and the roots were stored in a humid chamber at 37 +/- 1 degreesC for 14 days. The canals were reinstrumented and irrigated with sterile saline solution. Sterile paper points were used to transfer the root canal contents to test tubes containing sterile saline solution. Part of the suspension was harvested in Sabouraud dextrose agar with chloramphenicol and incubated at 37 +/- 1 degreesC for 48 h, CPMC was effective in 100% of the samples followed in decreasing order of effectiveness by calcium hydroxide with CPMC (70% effective), 1% sodium hypochlorite (70% effective) (p < 0.05), tricresol formalin (60% effective), 2% iodine-iodate solution (50% effective), calcium hydroxide paste (30% effective), and saline + no intracanal medication.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This study was conducted to observe the reaction of apical tissues of dogs' teeth after root canal filling with gutta-percha and mineral trioxide aggregate (MTA) or a glass ionomer (Ketac-Endo) as a sealer. The root canals were instrumented and filled by the lateral condensation technique with the sealers studied. Animals were killed 6 months later, and the specimens were removed and prepared for histological analysis. Results showed no inflammatory reaction of apical tissue and total closure of the apical foramen of all the teeth sealed with MTA. The teeth sealed with Ketac-Endo showed two cases of partial closure and different degrees of chronic inflammatory reaction. In conclusion, MTA exhibited better biological properties than Ketac-Endo. Copyright © 1999 by The American Association of Endodontists.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The objective of this study was to evaluate periapical and apical repair using calcium hydroxide root canal dressings for different lengths of times in teeth with induced chronic periapical lesions. A total of 61 root canals of maxillary and mandibular premolars from 4 dogs were used. After mechanical preparation of the root canals using the crown-down technique, and 5.25% NaOCl as irrigating solution, the apical foramen was enlarged in all cases. A calcium hydroxide root canal dressing was applied. The control group did not receive a root canal dressing. The animals were killed at 7, 15 or 30 days. After histological preparation, serial sections were stained with hematoxylin-eosin and Mallory's trichrome. The best histopathological results occurred at 15 and 30 days, and the worst results occurred at 7 days and in the control group.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This aim of this study was to evaluate the root apex of mandibular premolars regarding the presence of main and accessory foramina. The root apexes from fifty extracted mandibular single-rooted premolars were examined by scanning electron microscopy (SEM). The apical openings had their diameter measured and were identified as main or accessory foramina. Double blinded and calibrated examiners analyzed the SEM photographs and classified the premolar roots into three types, based on the presence and size of the apical openings. Type I: roots with a single main apical foramen and no accessory foramina; type II: roots with a main foramen and one or more accessory foramina; type III: roots with accessory foramina only. For the first premolar, 16 roots were classified as type I (48.48%), 4 as type II (12.12%) and 13 as type III (39.40%). For the second premolars, 10 roots were classified as type I (58.83%), 3 as type II (17.65%) and 4 as type III (23.52%). The high incidence of roots with accessory foramina only (type III), mainly in the first premolar, warns of the need for caution during working length determination and apical debridement.