997 resultados para ACTIVE METABOLITES


Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND: Risks of significant infant drug exposurethrough breastmilk are poorly defined for many drugs, and largescalepopulation data are lacking. We used population pharmacokinetics(PK) modeling to predict fluoxetine exposure levels ofinfants via mother's milk in a simulated population of 1000 motherinfantpairs.METHODS: Using our original data on fluoxetine PK of 25breastfeeding women, a population PK model was developed withNONMEM and parameters, including milk concentrations, wereestimated. An exponential distribution model was used to account forindividual variation. Simulation random and distribution-constrainedassignment of doses, dosing time, feeding intervals and milk volumewas conducted to generate 1000 mother-infant pairs with characteristicssuch as the steady-state serum concentrations (Css) and infantdose relative to the maternal weight-adjusted dose (relative infantdose: RID). Full bioavailability and a conservative point estimate of1-month-old infant CYP2D6 activity to be 20% of the adult value(adjusted by weigth) according to a recent study, were assumed forinfant Css calculations.RESULTS: A linear 2-compartment model was selected as thebest model. Derived parameters, including milk-to-plasma ratios(mean: 0.66; SD: 0.34; range, 0 - 1.1) were consistent with the valuesreported in the literature. The estimated RID was below 10% in >95%of infants. The model predicted median infant-mother Css ratio was0.096 (range 0.035 - 0.25); literature reported mean was 0.07 (range0-0.59). Moreover, the predicted incidence of infant-mother Css ratioof >0.2 was less than 1%.CONCLUSION: Our in silico model prediction is consistent withclinical observations, suggesting that substantial systemic fluoxetineexposure in infants through human milk is rare, but further analysisshould include active metabolites. Our approach may be valid forother drugs. [supported by CIHR and Swiss National Science Foundation(SNSF)]

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND: Acute blockade of the renin-angiotensin system with the parenterally active angiotensin II antagonist saralasin has been shown to effectively lower blood pressure in a large fraction of patients with essential hypertension and to improve haemodynamics in some patients with congestive heart failure. It is now possible to chronically antagonize angiotensin II at its receptor using non-peptide angiotensin II inhibitors such as losartan (DuP 753/MK-954) or TCV 116. EFFECT OF NON-PEPTIDE ANGIOTENSIN II ANTAGONISTS: When administered by mouth, DuP 753 and TCV 116 induce dose-dependent inhibition of the pressor response to exogenous angiotensin II. This effect is closely related to circulating levels of the corresponding active metabolites E3174 and CV11974. Preliminary studies performed in hypertensive patients suggest that losartan lowers blood pressure to an equivalent extent to an angiotensin converting enzyme (ACE) inhibitor. CONCLUSIONS: Further investigation is required to show whether these new angiotensin II antagonists compounds compare favourably with ACE inhibitors.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The pharmacokinetic and pharmacodynamic properties of nonpeptide angiotensin antagonists in humans are reviewed in this paper. Representatives of this new therapeutic class share common features: lipophilia, intermediate bioavailability, high affinity for plasma proteins and liver metabolism; some have active metabolites. Angiotensin II antagonists block the blood pressure response to exogenous angiotensin II in healthy volunteers, decrease baseline blood pressure in both normal and hypertensive patients, produce a marked rise in plasma renin activity and endogenous angiotensin II and increase renal blood flow without altering glomerular filtration rate. These effects are dose-dependent, but their time course varies between the drugs owing to pharmacokinetic and pharmacodynamic differences. Additionally, the extent of blood pressure reduction is dependent on physiological factors such as sodium and water balance. The characterisation of their pharmacokinetic-pharmacodynamic relationships deserves further refinement for designing optimal therapeutic regimens and proposing dosage adaptations in specific conditions.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The likelihood of significant exposure to drugs in infants through breast milk is poorly defined, given the difficulties of conducting pharmacokinetics (PK) studies. Using fluoxetine (FX) as an example, we conducted a proof-of-principle study applying population PK (popPK) modeling and simulation to estimate drug exposure in infants through breast milk. We simulated data for 1,000 mother-infant pairs, assuming conservatively that the FX clearance in an infant is 20% of the allometrically adjusted value in adults. The model-generated estimate of the milk-to-plasma ratio for FX (mean: 0.59) was consistent with those reported in other studies. The median infant-to-mother ratio of FX steady-state plasma concentrations predicted by the simulation was 8.5%. Although the disposition of the active metabolite, norfluoxetine, could not be modeled, popPK-informed simulation may be valid for other drugs, particularly those without active metabolites, thereby providing a practical alternative to conventional PK studies for exposure risk assessment in this population.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Two related and significant issues may elicit perplexity in medicinal chemists and are discussed here. First, a broad presentation of the pharmacological and toxicological consequences of drug metabolism should justify the significance of drug metabolism and serve as an incentive to further study. When comparing the pharmacological activities of a drug and its metabolite(s), a continuum is found which ranges from soft drugs (no active metabolites) to prodrugs (inactive per se, as illustrated here with clopidogrel and prasugrel). Innumerable intermediate cases document drugs whose activity is shared by one or more metabolites, as exemplified with tamoxifen. The toxicological consequences of metabolism at the molecular, macromolecular, and macroscopic levels are manyfold. A brief overview is offered together with a summary of the reactions of toxification and detoxification of the antiepileptic valproic acid. The second issue discussed in the review is a comparison of the relative significance of cytochromes P450 and other oxidoreductases (EC 1), hydrolases (EC 3), and transferases (EC 2) in drug metabolism, based on a 'guesstimate' of the number of drug metabolites that are known to be produced by them. The conclusion is that oxidoreductases are the main enzymes responsible for the formation of toxic or active metabolites, whereas transferases play the major role in producing inactive and nontoxic metabolites.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Five selective serotonin reuptake inhibitors (SSRIs) have been introduced recently: citalopram, fluoxetine, fluvoxamine, paroxetine and sertraline. Although no therapeutic window has been defined for SSRIs, in contrast to tricyclic antidepressants, analytical methods for therapeutic drug monitoring of SSRIs are useful in several instances. SSRIs differ widely in their chemical structure and in their metabolism. The fact that some of them have N-demethylated metabolites, which are also SSRIs, requires that methods be available which allow therapeutic drug monitoring of the parent compounds and of these active metabolites. most procedures are based on prepurification of the SSRIs by liquid-liquid extraction before they are submitted to separation by chromatographic procedures (high-performance liquid chromatography, gas chromatography, thin layer chromatography) and detection by various detectors (UV, fluorescence, electrochemical detector, nitrogen-phosphorus detector, mass spectrometry). This literature review shows that most methods allow quantitative determination of SSRIs in plasma, in the lower ng/ml range, and that they are, therefore, suitable for therapeutic drug monitoring purposes of this category of drugs.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

It is widely recognized that pharmacokinetic optimization needs to be addressed early in drug discovery to reduce the high failure rate in bringing drugs to market. Poor absorption, too short duration of action due to high elimination rate, or the presence of active metabolites are examples of properties that can potentially lead to unsuccessful clinical programmes. Here I describe a brief overview of advantages and molecular strategies for improving metabolic and pharmacokinetic properties applied to the discovery of fluconazol, beta-blockers, ritonavir and ezetimibe and to the development of the prodrugs enalapril and bambuterol.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A new polymeric coating consisting of a dual-phase, polydimethylsiloxane (PDMS) and polypyrrole (PPY) was developed for the stir bar sorptive extraction (SBSE) of antidepressants (mirtazapine, citalopram, paroxetine, duloxetine, fluoxetine and sertraline) from plasma samples, followed by liquid chromatography analysis (SBSE/LC-UV). The extractions were based on both adsorption (PPY) and sorption (PDMS) mechanisms. SBSE variables, such as extraction time, temperature, pH of the matrix, and desorption time were optimized, in order to achieve suitable analytical sensitivity in a short time period. The PDMS/PPY coated stir bar showed high extraction efficiency (sensitivity and selectivity) toward the target analytes. The quantification limits (LOQ) of the SBSE/LC-UV method ranged from 20 ng mL(-1) to 50 ng mL(-1), and the linear range was from LOQ to 500 ng mL(-1), with a determination coefficient higher than 0.99. The inter-day precision of the SBSE/LC-UV method presented a variation coefficient lower than 15%. The efficiency of the SBSE/LC-UV method was proved by analysis of plasma samples from elderly depressed patients. (C) 2008 Elsevier B.V. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In den letzten Jahren stieg in Deutschland der Gebrauch bzw. Missbrauch von Opioid-Analgetika zunehmend an. Das entwickelte Verfahren sollte unter Einbeziehung neuer Substanzen möglichst viele verschiedene Opioide und auch ihre pharmakologisch aktiven Stoffwechselprodukte berücksichtigen.rnVor Analyse wurden Blut-, Serum- oder Urinproben mit Phosphatpuffer versetzt und mittels Festphasenextraktion an C18-Säulenmaterial aufgearbeitet. Post-Mortem-Gewebematerial wurde mit isotonischer Kochsalzlösung versetzt, homogenisiert und anschließend durch eine Festphasenextraktion aufgereinigt. Haarproben wurden nach Zerkleinerung mit Methanol unter Ultrabeschallung extrahiert. Die Flüssigchromatographie gekoppelt mit Tandem-Massenspektrometrie (Elektrosprayionisation im positiven Modus) erwies sich als geeignetes Verfahren für die simultane Bestimmung der Opioide in biologischem Probenmaterial (Körperflüssigkeiten, Gewebe und Haaren). Der Multi-Analyt Assay erlaubt die quantitative Analyse von 35 verschiedenen Opioiden. Die Analyten wurden durch eine Phenyl-Hexyl Säule und einen Wasser/Acetonitril Gradienten durch eine UPLC 1290 Infinity gekoppelt mit einem 6490 Triple Quadrupol von Agilent Technologies separiert.rnDie LC/MS Methode zur simultanen Bestimmung von 35 Opioiden in Serum und Haaren wurde nach den Richtlinien der Gesellschaft für Toxikologische und Forensische Chemie (GTFCh) validiert. Im Fall der Serumvalidierung lagen die Nachweisgrenzen zwischen 0.02 und 0.6 ng/ml und die Bestimmungsgrenzen im Bereich von 0.1 bis 2.0 ng/ml. Die Kalibrationskurven waren für die Kalibrationslevel 1 bis 6 linear. Wiederfindungsraten lagen für alle Verbindungen zwischen 51 und 88 %, außer für Alfentanil, Bisnortiliidn, Pethidin und Morphin-3-Glucuronid. Der Matrixeffekt lag zwischen 86 % (Ethylmorphin) und 105 % (Desomorphin). Für fast alle Analyten konnten akzeptable Werte bei der Bestimmung der Genauigkeit und Richtigkeit nach den Richtlinien der GTFCh erhalten werden. Im Fall der Validierung der Haarproben lagen die Nachweisgrenzen zwischen 0.004 und 0.6 ng/Probe und die Bestimmungsgrenzen zwischen 0.1 ng/Probe und 2.0 ng/Probe. Für die Kalibrationslevel 1 bis 6 waren alle Kalibrationsgeraden linear. Die Wiederfindungsraten lagen für die Opioide im Bereich von 73.5 % (Morphin-6-Glucuronid) und 114.1 % (Hydrocodon). Die Werte für die Bestimmung der Richtigkeit lagen zwischen - 6.6 % (Methadon) und + 11.7 % (Pholcodin). Präzisionsdaten wurden zwischen 1.0 % für Dextromethorphan und 11.5 % für Methadon ermittelt. Die Kriterien der GTFCh konnten bei Ermittlung des Matrixeffekts für alle Substanzen erfüllt werden, außer für 6-Monoacetylmorphin, Bisnortilidin, Meperidin, Methadon, Morphin-3-glucuronid, Morphin-6-glucuronid, Normeperidin, Nortilidin und Tramadol.rnZum Test des Verfahrens an authentischem Probenmaterial wurden 206 Proben von Körperflüssigkeiten mit Hilfe der simultanen LC/MS Screening Methode untersucht. Über 150 Proben wurden im Rahmen von forensisch-toxikologischen Untersuchungen am Instituts für Rechtsmedizin Mainz analysiert. Dabei konnten 23 der 35 Opioide in den realen Proben nachgewiesen werden. Zur Untersuchung der Pharmakokinetik von Opioiden bei Patienten der anästhesiologischen Intensivstation mit Sepsis wurden über 50 Blutproben untersucht. Den Patienten wurde im Rahmen einer klinischen Studie einmal täglich vier Tage lang Blut abgenommen. In den Serumproben wurde hauptsächlich Sufentanil (0.2 – 0.8 ng/ml in 58 Fällen) und Piritramid (0.4 – 11 ng/ml in 56 Fällen) gefunden. Außerdem wurden die Proben von Körperflüssigkeiten und Gewebe von 13 verschiedenen Autopsiefällen mit Hilfe des Multi-Analyt Assays auf Opioide untersucht.rnIn einem zweiten Schritt wurde die Extraktions- und Messmethode zur Quantifizierung der 35 Opioide am Forensic Medicine Center in Ho Chi Minh City (Vietnam) etabliert. Insgesamt wurden 85 Herzblutproben von Obduktionsfällen mit Verdacht auf Opiatintoxikation näher untersucht. Der überwiegende Teil der untersuchten Fälle konnte auf eine Heroin- bzw. Morphin-Vergiftung zurückgeführt werden. Morphin wurde in 68 Fällen im Konzentrationsbereich 1.7 – 1400 ng/ml und der Heroinmetabolit 6-Monoactetylmorphin in 34 Fällen (0.3 – 160 ng/ml) nachgewiesen werden.rnSchließlich wurden noch 15 Haarproben von Patienten einer psychiatrischen Klinik, die illegale Rauschmittel konsumiert hatten, mit Hilfe der simultanen Opioid-LC/MS Screeningmethode gemessen. Die Ergebnisse der Untersuchung wurden mit früheren Auswertungen von gaschromatographischen Analysen verglichen. Es zeigte sich eine weitgehende Übereinstimmung der Untersuchungsergebnisse für die Opioide 6-Monoacetylmorphin, Morphin, Codein, Dihydrocodein und Methadon. Mit der LC/MS Methode konnten weitere Substanzen, wie zum Beispiel Bisnortilidin, Dextromethorphan und Tramadol in den Haarproben gefunden werden, die bislang nicht entdeckt worden waren.rn

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND Systemic approaches are needed to understand how variations in the genes associated with opioid pharmacokinetics and response can be used to predict patient outcome. The application of pharmacogenetic analysis to two cases of life-threatening opioid-induced respiratory depression is presented. The usefulness of genotyping in the context of these cases is discussed. METHODS A panel of 20 functional candidate polymorphisms in genes involved in the opioid biotransformation pathway (CYP2D6, UGT2B7, ABCB1, OPRM1, COMT) were genotyped in these two patients using commercially available genotyping assays. RESULTS In case 1, the patient experienced adverse outcomes when administered codeine and morphine, but not hydromorphone. Genetic test results suggested that this differential response may be due to an inherent propensity to generate active metabolites from both codeine and morphine. These active metabolites are not generated with hydromorphone. In case 2, the patient experienced severe respiratory depression during postoperative recovery following standard doses of morphine. The patient was found to carry genetic variations that result in decreased morphine efflux transporter activity at the blood-brain barrier and increased sensitivity to opioids. CONCLUSIONS Knowledge of the relative contribution of pharmacogenetic biomarkers and their influence on opioid response are continually evolving. Pharmacogenetic analysis, together with clinical history, has the potential to provide mechanistic insight into severe respiratory depressive events in patients who receive opioids at therapeutic doses.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The goal of this study was to investigate the cellular and molecular mechanisms by which glutathione (GSH) is involved in the process of apoptosis induced by cisplatin [cis-diamminedichloroplatinum(II), cis-DDP] in the HL60 human promyelocytic leukemia cell line. The data show that during the onset or induction of apoptosis, GSH levels in cisplatin-treated cells increased 50% compared to control cells. The increase in intracellular GSH was associated with enhanced expression of γ-glutamylcysteine synthetase (γ-GCS), the enzyme that catalyzes the rate- limiting step in the biosynthesis of glutathione. After depletion of intracellular GSH with D,L-buthionine-(S,R)-sulfoximine (BSO), an inhibitor of γ-GCS, biochemical and morphological analysis revealed that the mechanism of cell death had switched from apoptosis to necrosis. In contrast, when intracellular GSH was elevated by exposure of cells to a GSH-ethyl-ester and then treatment with cisplatin, no change in the induction and kinetics of apoptosis were observed. However, when cells were exposed to cisplatin before intracellular GSH levels were increased, apoptosis was observed to occur 6 hours earlier compared to cells without GSH elevation. To further examine the molecular aspects of these effects of GSH on the apoptotic process, changes in the expression of bcl-2 and bax, were investigated in cells with depleted and elevated GSH. Using reverse transcription polymerase chain reaction, no significant change in the expression of bcl-2 gene transcripts was observed in cells in either the GSH depleted or elevated state; however, a 75% reduction in GSH resulted in a 40% decrease in the expression of bax gene transcripts. In contrast, a 6-fold increase in GSH increased the expression of bax by 3-fold relative to controls. Similar results were obtained for bax gene expression and protein synthesis by northern analysis and immunoprecipitation, respectively. These results suggest that GSH serves a dual role in the apoptotic process. The first role which is indirect, involves the protection of the cell from extensive damage following exposure to a specific toxicant so as to prevent death by necrosis, possibly by interacting with the DNA damaging agent and/or its active metabolites. The second role involves a direct involvement of GSH in the apoptotic process that includes upregulation of bax expression. ^