981 resultados para 3 CLASSIC CRITERIA
Resumo:
This paper explored a new approach to prepare phase change microcapsules using carbon-based particles via Pickering emulsions for energy storage applications. Rice-husk-char, a by-product in biofuel production, containing 53.58 wt% of carbon was used as a model carbon-based material to encapsulate hexadecane. As a model phase change material, hexadecane was emulsified in aqueous suspensions of rice-husk-char nanoparticles. Water soluble polymers poly(diallyldimethyl-ammonium chloride) and poly(sodium styrene sulfonate) were used to fix the rice-husk-char nanoparticles on the emulsion droplets through layer-by-layer assembly to enhance the structural stability of the microcapsules. The microcapsules formed are composed of a thin shell encompassing a large core consisting of hexadecane. Thermal gravimetrical and differential scanning calorimeter analyses showed the phase change enthalpy of 80.9 kJ kg−1 or 120.0 MJ m−3. Design criteria of phase change microcapsules and preparation considerations were discussed in terms of desired applications. This work demonstrated possible utilisations of biomass-originated carbon-based material for thermal energy recovery and storage applications, which can be a new route of carbon capture and utilisation.
Resumo:
Aims of the study: 1) Cardiovascular risk assessment of a cohort of children with a clinical diagnosis of FH; 2) Identification of biomarkers to distinguish between monogenic and polygenic/environmental dyslipidemia in clinical settings; 3) Clinical criteria improvement to identify FH children.
Resumo:
The thesis deals with the problem of Model Selection (MS) motivated by information and prediction theory, focusing on parametric time series (TS) models. The main contribution of the thesis is the extension to the multivariate case of the Misspecification-Resistant Information Criterion (MRIC), a criterion introduced recently that solves Akaike’s original research problem posed 50 years ago, which led to the definition of the AIC. The importance of MS is witnessed by the huge amount of literature devoted to it and published in scientific journals of many different disciplines. Despite such a widespread treatment, the contributions that adopt a mathematically rigorous approach are not so numerous and one of the aims of this project is to review and assess them. Chapter 2 discusses methodological aspects of MS from information theory. Information criteria (IC) for the i.i.d. setting are surveyed along with their asymptotic properties; and the cases of small samples, misspecification, further estimators. Chapter 3 surveys criteria for TS. IC and prediction criteria are considered for: univariate models (AR, ARMA) in the time and frequency domain, parametric multivariate (VARMA, VAR); nonparametric nonlinear (NAR); and high-dimensional models. The MRIC answers Akaike’s original question on efficient criteria, for possibly-misspecified (PM) univariate TS models in multi-step prediction with high-dimensional data and nonlinear models. Chapter 4 extends the MRIC to PM multivariate TS models for multi-step prediction introducing the Vectorial MRIC (VMRIC). We show that the VMRIC is asymptotically efficient by proving the decomposition of the MSPE matrix and the consistency of its Method-of-Moments Estimator (MoME), for Least Squares multi-step prediction with univariate regressor. Chapter 5 extends the VMRIC to the general multiple regressor case, by showing that the MSPE matrix decomposition holds, obtaining consistency for its MoME, and proving its efficiency. The chapter concludes with a digression on the conditions for PM VARX models.
Resumo:
Background. One of the most diffused types of arthrities is Knee Osteoarthritis. Among symptoms found correlated to this disorder are: pain, joint stiffness, decresed muscle strenght. All these symptoms lead to a decreased function, difficulty in partcipation in physical activity, and decreased quality of life. Is Hydrotherapy increases strenght and mobility of patients for a better quality of life and society partecipation? Outcome. The aim of this Systematic Review is to verify efficacy of Hydrotherapy on upmentioned factors compared to conservative physical rehabilitation and self physical treatment. Study design. Systematc Review following The preffered Reporting Itemes For Systematic Reviews and Meta-analyses (PRISMA) statement checklist [3] Eligibility criteria. Chioice of RCTs which investigate changes in patients’ outcome who suffer from knee osteoarthritis applying Hydrotherapy treatment compared to conservative physical therapy treatment and self physical treatment. Method. Database research: PubMed, PEDro, Cochrane Central Register of Controlled Trial. Results. These reviewed studies show that Hydrotherapy induces improvements comparable with only gym treatment on muscle strenght, and step kinematic parameters, and it’s an ally of reduction of pain. Inaddition, Hydrotherapy is considered more effective physical treatment for knee orsteoarthrtis than the only conservative physical treatment and self physical treatment regarding parameters above mentioned. Conclusion. Hydrotherapy may be a valid alternative compared to only gym treatment, better than self physical treatment in pain relief and increases patients’ general physical health. Key words. Rehabilitation, Hydrotherapy, knee osteoarthritis, aquatic exercise, pain, self care, gait, balance.
Resumo:
ECG criteria for left ventricular hypertrophy (LVH) have been almost exclusively elaborated and calibrated in white populations. Because several interethnic differences in ECG characteristics have been found, the applicability of these criteria to African individuals remains to be demonstrated. We therefore investigated the performance of classic ECG criteria for LVH detection in an African population. Digitized 12-lead ECG tracings were obtained from 334 African individuals randomly selected from the general population of the Republic of Seychelles (Indian Ocean). Left ventricular mass was calculated with M-mode echocardiography and indexed to body height. LVH was defined by taking the 95th percentile of body height-indexed LVM values in a reference subgroup. In the entire study sample, 16 men and 15 women (prevalence 9.3%) were finally declared to have LVH, of whom 9 were of the reference subgroup. Sensitivity, specificity, accuracy, and positive and negative predictive values for LVH were calculated for 9 classic ECG criteria, and receiver operating characteristic curves were computed. We also generated a new composite time-voltage criterion with stepwise multiple linear regression: weighted time-voltage criterion=(0.2366R(aVL)+0.0551R(V5)+0.0785S(V3)+ 0.2993T(V1))xQRS duration. The Sokolow-Lyon criterion reached the highest sensitivity (61%) and the R(aVL) voltage criterion reached the highest specificity (97%) when evaluated at their traditional partition value. However, at a fixed specificity of 95%, the sensitivity of these 10 criteria ranged from 16% to 32%. Best accuracy was obtained with the R(aVL) voltage criterion and the new composite time-voltage criterion (89% for both). Positive and negative predictive values varied considerably depending on the concomitant presence of 3 clinical risk factors for LVH (hypertension, age >/=50 years, overweight). Median positive and negative predictive values of the 10 ECG criteria were 15% and 95%, respectively, for subjects with none or 1 of these risk factors compared with 63% and 76% for subjects with all of them. In conclusion, the performance of classic ECG criteria for LVH detection was largely disparate and appeared to be lower in this population of East African origin than in white subjects. A newly generated composite time-voltage criterion might provide improved performance. The predictive value of ECG criteria for LVH was considerably enhanced with the integration of information on concomitant clinical risk factors for LVH.
Resumo:
PURPOSE: To evaluate 2 left ventricular mass index (LVMI) normality criteria for the prevalence of left ventricular geometric patterns in a hypertensive population ( HT ) . METHODS: 544 essential hypertensive patients, were evaluated by echocardiography, and different left ventricular hypertrophy criteria were applied: 1 - classic : men - 134 g/m² and women - 110 g/m² ; 2- obtained from the 95th percentil of LVMI from a normotensive population (NT). RESULTS: The prevalence of 4 left ventricular geometric patterns, respectively for criteria 1 and 2, were: normal geometry - 47.7% and 39.3%; concentric remodelying - 25.4% and 14.3%; concentric hypertrophy - 18.4% and 27.7% and excentric hypertrophy - 8.8% and 16.7%, which confered abnormal geometry to 52.6% and 60.7% of hypertensive. The comparative analysis between NT and normal geometry hypertensive group according to criteria 1, detected significative stuctural differences,"( *p < 0.05):LVMI- 78.4 ± 1.50 vs 85.9 ±0.95 g/m² *; posterior wall thickness -8.5 ± 0.1 vs 8.9 ± 0.05 mm*; left atrium - 33.3 ± 0.41 vs 34.7 ± 0.30 mm *. With criteria 2, significative structural differences between the 2 groups were not observed. CONCLUSION: The use of a reference population based criteria, increased the abnormal left ventricular geometry prevalence in hypertensive patients and seemed more appropriate for left ventricular hypertrophy detection and risk stratification.
Resumo:
OBJECTIVES: The aim of this study was to evaluate new electrocardiographic (ECG) criteria for discriminating between incomplete right bundle branch block (RBBB) and the Brugada types 2 and 3 ECG patterns. BACKGROUND: Brugada syndrome can manifest as either type 2 or type 3 pattern. The latter should be distinguished from incomplete RBBB, present in 3% of the population. METHODS: Thirty-eight patients with either type 2 or type 3 Brugada pattern that were referred for an antiarrhythmic drug challenge (AAD) were included. Before AAD, 2 angles were measured from ECG leads V(1) and/or V(2) showing incomplete RBBB: 1) α, the angle between a vertical line and the downslope of the r'-wave, and 2) β, the angle between the upslope of the S-wave and the downslope of the r'-wave. Baseline angle values, alone or combined with QRS duration, were compared between patients with negative and positive results on AAD. Receiver-operating characteristic curves were constructed to identify optimal discriminative cutoff values. RESULTS: The mean β angle was significantly smaller in the 14 patients with negative results on AAD compared to the 24 patients with positive results on AAD (36 ± 20° vs. 62 ± 20°, p < 0.01). Its optimal cutoff value was 58°, which yielded a positive predictive value of 73% and a negative predictive value of 87% for conversion to type 1 pattern on AAD; α was slightly less sensitive and specific compared with β. When the angles were combined with QRS duration, it tended to improve discrimination. CONCLUSIONS: In patients with suspected Brugada syndrome, simple ECG criteria can enable discrimination between incomplete RBBB and types 2 and 3 Brugada patterns.
Resumo:
PURPOSE: Cardiovascular magnetic resonance (CMR) has become a robust and important diagnostic imaging modality in cardiovascular medicine. However,insufficient image quality may compromise its diagnostic accuracy. No standardized criteria are available to assess the quality of CMR studies. We aimed todescribe and validate standardized criteria to evaluate the quality of CMR studies including: a) cine steady-state free precession, b) delayed gadoliniumenhancement, and c) adenosine stress first-pass perfusion. These criteria will serve for the assessment of the image quality in the setting of the Euro-CMR registry.METHOD AND MATERIALS: First, a total of 45 quality criteria were defined (35 qualitative criteria with a score from 0-3, and 10 quantitative criteria). Thequalitative score ranged from 0 to 105. The lower the qualitative score, the better the quality. The quantitative criteria were based on the absolute signal intensity (delayed enhancement) and on the signal increase (perfusion) of the anterior/posterior left ventricular wall after gadolinium injection. These criteria were then applied in 30 patients scanned with a 1.5T system and in 15 patients scanned with a 3.0T system. The examinations were jointly interpreted by 3 CMR experts and 1 study nurse. In these 45 patients the correlation between the results of the quality assessment obtained by the different readers was calculated.RESULTS: On the 1.5T machine, the mean quality score was 3.5. The mean difference between each pair of observers was 0.2 (5.7%) with a mean standarddeviation of 1.4. On the 3.0T machine, the mean quality score was 4.4. The mean difference between each pair of onservers was 0.3 (6.4%) with a meanstandard deviation of 1.6. The quantitative quality assessments between observers were well correlated for the 1.5T machine: R was between 0.78 and 0.99 (pCONCLUSION: The described criteria for the assessment of CMR image quality are robust and have a low inter-observer variability, especially on 1.5T systems.CLINICAL RELEVANCE/APPLICATION: These criteria will allow the standardization of CMR examinations. They will help to improve the overall quality ofexaminations and the comparison between clinical studies.
Resumo:
Le syndrome de Brugada, une affection rythmique du sujet jeune potentiellement fatale, se manifeste sur l'ECG par un bloc de branche droit (BBD) complet, avec sus-décalage majeur du segment ST et inversion des ondes 32; de V1 à V3 appelé pattern de type 1. Cette présentation peut être intermittente. Les manifestations incomplètes du syndrome de Brugada sont appelées patterns de types 2 ou 3, et sont caractérisées par un BBD incomplet et un sus-décalage ST plus ou moins prononcé dans les dérivations V-, et V2 de l'ECG. Cette description, cependant, est aussi celle du BBD incomplet fréquemment rencontré chez les sujets jeunes, de moins de 40 ans, et présent dans 3% de la population. Bo nombre de ces sujets sont donc référés pour une recherche de syndrome de Brugada. Le but de cette thèse est donc d'évaluer de nouveaux critères permettant de discriminer les BBD incomplets, banals, des sujets porteurs d'un syndrome de Brugada de types 2 ou 3. Trente-huit patients avec un pattern de Brugada de types 2 et 3, référés pour un test médicamenteux utilisant un antiarythmique révélant un pattern de type 1 chez les sujets porteurs, ont été inclus dans l'étude. Avant le test médicamenteux, deux angles ont été mesurés sur les dérivations Vi et/ou V2 : a, l'angle entre une ligne verticale et la descente de l'onde r', et β, l'angle entre la montée de l'onde S et la descente de l'onde r'. Les mesure à l'état basai des deux angles, seules ou combinées avec la durée du QRS, on été comparées entre les patients avec une épreuve pharmacologique positive et ceux dont l'épreuve s'est révélée négative (i.e. servant de groupe contrôle car porteur d'un véritable BBD incomplet). Des courbes ROC ont été établies afin de déterminer les valeurs d'angles les plus discriminantes. La moyenne des angles β était significativement plus petite chez les 14 patients avec un test pharmacologique négatif comparé aux 24 patients avec un test positif. La valeur optimale pour l'angle β était de 58°, ce qui donnait une valeur prédictive positive de 73% et une valeur prédictive négative de 97% pour une conversion en pattern de type 1 lors du test pharmacologique. L'angle α était un peu moins sensible et spécifique que β. Quand les angles étaient combinés à la durée du QRS, on observait une discrète amélioration de la discrimination entre les deux populations. Notre travail permet donc, chez des patients suspects d'un syndrome de Brugada, de discriminer entre un BBD incomplet et les patterns de Brugada types 2 et 3 en utilisant un critère simple basé sur l'ECG de surface potentiellement applicable au lit du patient
Resumo:
In the previous study, moisture loss indices were developed based on the field measurements from one CIR-foam and one CIR-emulsion construction sites. To calibrate these moisture loss indices, additional CIR construction sites were monitored using embedded moisture and temperature sensors. In addition, to determine the optimum timing of an HMA overlay on the CIR layer, the potential of using the stiffness of CIR layer measured by geo-gauge instead of the moisture measurement by a nuclear gauge was explored. Based on the monitoring the moisture and stiffness from seven CIR project sites, the following conclusions are derived: 1. In some cases, the in-situ stiffness remained constant and, in other cases, despite some rainfalls, stiffness of the CIR layers steadily increased during the curing time. 2. The stiffness measured by geo-gauge was affected by a significant amount of rainfall. 3. The moisture indices developed for CIR sites can be used for predicting moisture level in a typical CIR project. The initial moisture content and temperature were the most significant factors in predicting the future moisture content in the CIR layer. 4. The stiffness of a CIR layer is an extremely useful tool for contractors to use for timing their HMA overlay. To determine the optimal timing of an HMA overlay, it is recommended that the moisture loss index should be used in conjunction with the stiffness of the CIR layer.
Resumo:
The objective of this work was to determine soybean resistance inheritance to Heterodera glycines Ichinohe (soybean cyst nematode - SCN) races 3 and 9, as well as to evaluate the efficiency of direct and indirect selection in a soybean population of 112 recombinant inbred lines (RIL) derived from the resistant cultivar Hartwig. The experiment was conducted in a completely randomized design, in Londrina, PR, Brazil. The estimated narrow-sense heritabilities for resistance to races 3 and 9 were 80.67 and 77.97%. The genetic correlation coefficient (r g = 0.17; p<0.01) shows that some genetic components of resistance to these two races are inherited together. The greatest genetic gain by indirect selection was obtained to race 9, selecting to race 3 due to simpler inheritance of resistance to race 9 and not because these two races share common resistance genes. The resistance of cultivar Hartwig to races 3 and 9 is determined by 4 and 2 genes, respectively. One of these genes confers resistance to both races, explaining a fraction of the significant genetic correlation found between resistance to these SCN races. The inheritance pattern described indicates that selection for resistance to SCN must be performed for each race individually.
Resumo:
Objective To compare the diagnostic accuracy of the classic Meisels cytologic criteria and the Schneider secondary criteria relative to the hybrid capture method for diagnosing HPV infection. Methods This was a retrospective study performed at a public university hospital. A total of 41 patients with a cytologic diagnosis of HPV infection and 40 HPV-negative patients were selected for review of the cervical-vaginal smears seeking to classical and secondary criteria. A single pathologist reviewed the slides in search of the criteria. The classical and secondary cytologic criteria were compared with the hybrid capture for diagnosing HPV infection. Bartleti test was applied for the age analysis, and Fisher's exact test was used to compare proportions. The tests were considered significant when the probability of rejecting the null hypothesis was less than 5% (p < 0.05). Results The Meisels criteria were less sensitive (34.0%) than the secondary Schneider criteria (57.5%) when compared with the hybrid capture (p < 0.0001), although the specificity of the former criteria was non-significantly higher (91.2% and 67.7%, respectively). In cases of moderate or intense inflammation, the sensitivity and specificity of the Schneider criteria were decreased, 33.3% and 50.0% respectively (p = 0.0115). Conclusions Compared with hybrid capture for diagnosis of HPV infection, the sensitivity of the secondary Schneider criteria was higher than the classical Meisels criteria.Moderate or intense inflammation reduces the sensitivity and specificity of the secondary Schneider criteria for diagnosing HPV infection using the hybrid capture as the gold standard.