997 resultados para 193-1188A


Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Magmatic fluids, heat fluxes, and fluid/rock interactions associated with hydrothermal systems along spreading centers and convergent margins have a significant impact on the genesis of major sulfide deposits and biological communities. Circulation of hydrothermal fluids is one of the most fundamental processes associated with localized mineralization and is controlled by inherent porous and permeable properties of the ocean crust. Heat from magmatic intrusions drives circulation of seawater through permeable portions of the oceanic crust and upper mantle, discharging at the seafloor as both focused high-temperature (250°-400°C) fluids and diffuse lower-temperature (<250°C) fluids. This complex interaction between the circulating hydrothermal fluids and the oceanic basement greatly influences the physical properties and the composition of the crust (Thompson, 1983; Jacobson, 1992, doi:10.1029/91RG02811; Johnson and Semyan, 1994, doi:10.1029/93JB00717). During Ocean Drilling Program (ODP) Leg 193, 13 holes were drilled in the PACMANUS hydrothermal system (Binns, Barriga, Miller, et al., 2002, doi:10.2973/odp.proc.ir.193.2002). The hydrothermal system consists of isolated hydrothermal deposits lined along the main crest of the Pual Ridge, a 500- to 700-m-high felsic neovolcanic ridge in the eastern Manus Basin. The principal drilling targets were the Snowcap (Site 1188) and Roman Ruins (Site 1189) active hydrothermal fields. Samples from these two sites were used for a series of permeability, electrical resistivity, and X-ray computed tomography measurements.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Postcruise X-ray diffraction (XRD) data for 95 whole-rock samples from Holes 1188A, 1188F, 1189A, and 1189B are presented. The samples represent alteration types recovered during Leg 193. The data set is incorporated into the shipboard XRD data set. Based on the newly obtained XRD data, distribution of alteration phases were redrawn for Ocean Drilling Program Sites 1188 and 1189.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The conventional model of leaching volcanic rocks as a source of metals in a seafloor hydrothermal systems has been tested by examining the behavior of Pb and other trace elements during hydrothermal alteration. ODP Leg 193 drill sites 1188 (Snowcap) and 1189 (Roman Ruins) on Pual Ridge in the eastern Manus Basin offshore eastern Papua New Guinea provide a unique three-dimensional window into an active back-arc hydrothermal system. We investigate by means of a LA-ICP-MS microbeam technique the capacity of Pb to be leached from a host volcanic rock exposed to various types and intensities of alteration. Our results are in general agreement with previous studies that utilized bulk analytical techniques but provide a more detailed explanation of the processes. Fresh representative dacitic lavas from the Pual Ridge have an average whole rock Pb content of 5.2 ppm, an average interstitial glass Pb content of 5.6 ppm and an average plagioclase Pb content of 1.0 ppm. Altered matrix samples have highly variable Pb values ranging from 0 to 52.4 ppm. High Pb values in altered samples are associated with a low temperature chlorite and clay mineral assemblage, in some cases overprinted by a high temperature (up to 350°C) silica-rich "bleaching" alteration. Only the most highly altered matrix samples have REE patterns that differ from the fresh Pual Ridge dacite. This may represent either different lava histories or alteration characteristics that have affected normally immobile REEs. Altered samples with the highest Pb values have similar REE patterns to those of the local unaltered lavas. They are compositionally similar to typical Pual Ridge dacites indicating a genetic relationship between the main regional volcanic suite and the subseafloor hydrothermally altered, Pb-enriched material. Relative loss/gain for Pb between the analyzed altered samples and a calculated precursor show a maximum relative gain of 901%. Samples with relative Pb gain from both drill sites are associated with lower temperature alteration mineral assemblages characterized by pervasive chloritization. The related lower temperature (220-250°C) neutral to slightly acidic fluids have been ascribed by others to return circulation of hydrothermal fluids that did not interact with seawater. Because altered samples have a higher Pb content than the fresh precursor, leaching of fresh volcanic rocks cannot be the source of Pb in the hydrothermal systems.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

This report presents short-wave infrared spectroscopic data acquired from both core and powdered samples collected during Ocean Drilling Program Leg 193, from Holes 1188A, 1188F, and 1189A, using a Portable Infrared Mineral Analyzer reflectance spectrometer. The distribution of alteration minerals detected using this method for each site is presented.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

A geochemical, mineralogical, and isotopic database comprising 75 analyses of Ocean Drilling Program (ODP) Leg 193 samples has been prepared, representing the variable dacitic volcanic facies and alteration types observed in drill core from the subsurface of the PACMANUS hydrothermal system (Table T1. The data set comprises major elements, trace and rare earth elements (REE), various volatiles (S, F, Cl, S, SO4, CO2, and H2O), and analyses of 18O and 86Sr/87Sr for bulk rock and mineral separates (anhydrite). Furthermore, normative mineral proportions have been calculated based on the results of X-ray diffraction (XRD) analysis (Table T2) using the SOLVER function of the Microsoft Excel program. Several of the samples analyzed consist of mesoscopically distinctive domains, and separate powders were generated to investigate these hand specimen-scale heterogeneities. Images of all the samples are collated in Figure F1, illustrating the location of each powder analyzed and documenting which measurements were performed.