976 resultados para 120-749


Relevância:

30.00% 30.00%

Publicador:

Relevância:

30.00% 30.00%

Publicador:

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Calcareous nannofossils are abundant in the Paleogene sediments recovered during Ocean Drilling Program Leg 120. Although no continuous Paleogene section was obtained, Sites 747 through 751 complemented each other so as to provide a virtually complete composite stratigraphic section. The calcareous nannofossil biostratigraphy at Sites 747, 748, and 749 is discussed. Correlation of calcareous nannofossil biozones and magnetozones at these sites suggests some diachrony with low-latitude areas, as well as on a regional basis. Changes in calcareous nannofossil diversity throughout the Paleogene are analyzed and interpreted as reflecting major paleoclimatic events.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We are pleased to present the papers from the Australasian Health Informatics and Knowledge Management (HIKM) conference stream held on 20 January 2011 in Perth as a session of the Australasian Computer Science Week (ASCW) 2011. Formerly HIKM was named Health Data and Knowledge Management, however the inclusion of the health informatics term is timely given the current health reform. The submissions to HIKM 2011 demonstrated that Australasian researchers lead with many research and development innovations coming to fruition. Some of these innovations can be seen here, and we believe further recognition will accomplish by continuation to HIKM in the future. The HIKM conference is a review of health informatics related research, development and education opportunities. The conference papers were written to communicate with other researchers and share research findings, capturing each and every aspect of the health informatics field. They are namely: conceptual models and architectures, privacy and quality of health data, health workflow management patient journey analysis, health information retrieval, analysis and visualisation, data integration/linking, systems for integrated or coordinated care, electronic health records (EHRs) and personally controlled electronic health records (PCEHRs), health data ontologies, and standardisation in health data and clinical applications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The flow around a 120 degrees blunt cone model with a base radius of 60mm has been visualised at Mach 14.8 and 9.1 using argon as the test gas, at the newly established high speed schlieren facility in the IISc hypersonic shock tunnel HST2. The experimental shock stand off distance around the blunt cone is compared with that obtained using a commercial CFD package. The computed values of shock stand off distance of the blunt cone is found to agree reasonably well with the experimental data.