967 resultados para 02290717 TM-2
Resumo:
The objective of this work was to investigate the factors that inhibit the use of Environmental Techniques in the Gas Station of the city of Natal/RN. For this, a survey with the aid of a questionnaire was used like research instrument. It s used a sample for convenience, not probabilistic. For collection of the data, it was used directly application of the questionnaire to the Managers or Assistant managers of the gas station, in accordance with its availability or presence. The data was collected in all the regions of Natal (North, South, East and West). The population in accordance with the data of the ANP of September 2005 is of 111 ranks and the collected sample was of 86. To carry through the analysis of the data of this research had been used softwares Excel and Statistic version 5.0, for Windows. The analysis of data is divided in two parts; descriptive analysis and analysis of groupings (clusters). The results showed that bigger part of the interviewed ones has between 30 and 39 years of age; they have second grade completed; they had declared to have little between and reasonable knowledge how much to the use of Clean Technology (CT) in gas station; and a small part of the interviewed ones had informed to have much knowledge how much the resolutions of the CONAMA established for the Gas Station. Of the searched ranks, the majority is national(76.7%); the most accurate practice environmental used in the gas station are: it collects selective of oil used or contaminated and ecological tanks - coated with strengthened fibre glass; great part of the interviewed ones (33.8%) informed that never the TL makes planning of referring future action; about of the half of the interviewed ones (84.9%) they had more declared that its employees have of none to a reasonable level of training for deal with problems that compromise the environment; the majority of the ranks (72.1%) functions has for more then six years. It is observed that almost all the interviewed ones (96.5%) evaluate as being important or very important the implantation of CT in Gas Station and the great majority (82.1%) evaluates the difficulty in if implanting these technologies in Gas Station as being easy or very easy. In the analysis of cluster, it was verified existence of two groupings (as much in the variable of the barriers and benefits), being that inside of each clusters exists homogeneity and between clusters exists heterogeneity. In reality, everything is important or very important in the opinion of the interviewed ones. There only exists a small significant difference that separates them in clusters
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Objective: This study aimed at evaluating the degree of conversion (DC) of four composite resins, being one nanofilled and 3 microhybrid resins, photo-activated with second- and third-generation light-emitting diodes (LEDs). Material and methods: Filtek (TM) Z350 nanofilled composite resins and Amelogen (R) Plus, Vit-l-escence (TM) and Opallis microhybrid resins were photo-activated with two second-generation LEDs (Radii-cal and Elipar Free Light (TM) 2) and one third-generation LED (Ultra-Lume LED 5) by continuous light mode, and a quartz halogen-tungsten bulb (QHT, control). After 24 h of storage, the samples were pulverized into fine powder and 5 mg of each material were mixed with 100 mg of potassium bromide (KBr). After homogenization, they were pressed, which resulted in a pellet that was evaluated using an infrared spectromer (Nexus 470, Thermo Nicolet) equipped with TGS detector using diffuse reflectance (32 scans, resolution of 4 cm(-1)) coupled to a computer. The percentage of unreacted carbon-carbon double bonds (% C=C) was determined from the ratio of absorbance intensities of aliphatic C=C (peak at 1637 cm-1) against internal standard before and after curing of the specimen: aromatic C-C (peak at 1610 cm-1). Results: The ANOVA showed a significant effect on the interaction between the light-curing units (LCUs) and the composite resins (p<0.001). The Tukey's test showed that the nanofilled resin (Filtek (TM) Z350) and Opallis when photo-activated by the halogen lamp (QTH) had the lowest DC compared with the other microhybrid composite resins. The DC of the nanofilled resin (Filtek (TM) Z350) was also lower using LEDs. The highest degrees of conversion were obtained using the third-generation LED and one of second-generation LEDs (Elipar Free Light (TM) 2). Conclusions: The nanofilled resin showed the lowest DC, and the Vit-l-escence (TM) microhybrid composite resin showed the highest DC. Among the LCUs, it was not possible to establish an order, even though the second-generation LED Radii-cal provided the lowest DC.
Resumo:
O objetivo foi identificar os determinantes da saúde ruim em populações ribeirinhas menores de dois anos, residentes no Pará, Brasil. Foram avaliadas 202 crianças, considerando-se saúde ruim como variável desfecho, sendo composta pela combinação do estado nutricional, desenvolvimento físico-motor e intercorrências no último mês. Utilizou-se modelo multinível de análise hierárquica, considerando-se como preditoras da saúde ruim variáveis com p < 0,05 após ajuste. A razão de chance bruta apontou que o estado de saúde ruim é maior para as crianças de famílias que têm casa própria, são de maior idade e têm probabilidade de aleitamento materno exclusivo aos dois, três, quatro e cinco meses. Após ajuste, observa-se que crianças provenientes de famílias com casa própria têm 2,76 vezes mais chance de ter saúde ruim; esta também aumenta com a idade, chegando a ser 5,04 vezes maior entre as crianças de 18 a 23 meses, comparativamente às menores de 7 meses. Ter casa própria e mais idade representam, nessas comunidades, mais tempo de exposição ao risco de saúde ruim.
Resumo:
Objective: This study aimed at evaluating the degree of conversion (DC) of four composite resins, being one nanofilled and 3 microhybrid resins, photo-activated with second- and third-generation light-emitting diodes (LEDs). Material and methods: Filtek (TM) Z350 nanofilled composite resins and Amelogen (R) Plus, Vit-l-escence (TM) and Opallis microhybrid resins were photo-activated with two second-generation LEDs (Radii-cal and Elipar Free Light (TM) 2) and one third-generation LED (Ultra-Lume LED 5) by continuous light mode, and a quartz halogen-tungsten bulb (QHT, control). After 24 h of storage, the samples were pulverized into fine powder and 5 mg of each material were mixed with 100 mg of potassium bromide (KBr). After homogenization, they were pressed, which resulted in a pellet that was evaluated using an infrared spectromer (Nexus 470, Thermo Nicolet) equipped with TGS detector using diffuse reflectance (32 scans, resolution of 4 cm(-1)) coupled to a computer. The percentage of unreacted carbon-carbon double bonds (% C=C) was determined from the ratio of absorbance intensities of aliphatic C=C (peak at 1637 cm-1) against internal standard before and after curing of the specimen: aromatic C-C (peak at 1610 cm-1). Results: The ANOVA showed a significant effect on the interaction between the light-curing units (LCUs) and the composite resins (p<0.001). The Tukey's test showed that the nanofilled resin (Filtek (TM) Z350) and Opallis when photo-activated by the halogen lamp (QTH) had the lowest DC compared with the other microhybrid composite resins. The DC of the nanofilled resin (Filtek (TM) Z350) was also lower using LEDs. The highest degrees of conversion were obtained using the third-generation LED and one of second-generation LEDs (Elipar Free Light (TM) 2). Conclusions: The nanofilled resin showed the lowest DC, and the Vit-l-escence (TM) microhybrid composite resin showed the highest DC. Among the LCUs, it was not possible to establish an order, even though the second-generation LED Radii-cal provided the lowest DC.