872 resultados para validation interne


Relevância:

20.00% 20.00%

Publicador:

Resumo:

We have previously shown that a 28-amino acid peptide derived from the BRC4 motif of BRCA2 tumor suppressor inhibits selectively human RAD51 recombinase (HsRad51). With the aim of designing better inhibitors for cancer treatment, we combined an in silico docking approach with in vitro biochemical testing to construct a highly efficient chimera peptide from eight existing human BRC motifs. We built a molecular model of all BRC motifs complexed with HsRad51 based on the crystal structure of the BRC4 motif-HsRad51 complex, computed the interaction energy of each residue in each BRC motif, and selected the best amino acid residue at each binding position. This analysis enabled us to propose four amino acid substitutions in the BRC4 motif. Three of these increased the inhibitory effect in vitro, and this effect was found to be additive. We thus obtained a peptide that is about 10 times more efficient in inhibiting HsRad51-ssDNA complex formation than the original peptide.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Earlobe Arterialized Blood Collector® is a minimally invasive system able to perform arterialized capillary blood gas analysis from the earlobe (EL). A prospective validation study was performed in 55 critical ill patients. Sampling failure rate was high (53.6%). Risk factors were age > 65 years, diabetes, vasoactive drug therapy and noradrenaline (NA) doses above 0.22 μg / kg / min. Multivariate analysis showed age > 65 years was the only factor independently associated with failure. Concordance analysis with arterial blood gases and Bland-Altman agreement evaluation were insufficient for validating the new system for all gasometrical variables.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to present the initial validation of a new questionnaire, the Transition to Retirement Questionnaire (TRQ) and to study its relationship with resistance to change and personality dimensions. Based on Schlossberg's typology of the retired, the TRQ is designed to assess five dimensions related to personal perceptions of transition to retirement, retirement, and personal plans and activities. The sample consisted of 1,054 professionally active or retired adults from the Swiss French-speaking Canton of Vaud. Exploratory principal components and confirmatory factor analyses highlighted a five-factor solution that fit coherently with Schlossberg's typology. Moreover, TRQ dimensions were related to resistance to change tendencies and personality dimensions. The TRQ seems to be an interesting tool for use in research but also for interventions with young retirees or people preparing for retirement.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Principal mechanisms of resistance to azole antifungals include the upregulation of multidrug transporters and the modification of the target enzyme, a cytochrome P450 (Erg11) involved in the 14alpha-demethylation of ergosterol. These mechanisms are often combined in azole-resistant Candida albicans isolates recovered from patients. However, the precise contributions of individual mechanisms to C. albicans resistance to specific azoles have been difficult to establish because of the technical difficulties in the genetic manipulation of this diploid species. Recent advances have made genetic manipulations easier, and we therefore undertook the genetic dissection of resistance mechanisms in an azole-resistant clinical isolate. This isolate (DSY296) upregulates the multidrug transporter genes CDR1 and CDR2 and has acquired a G464S substitution in both ERG11 alleles. In DSY296, inactivation of TAC1, a transcription factor containing a gain-of-function mutation, followed by sequential replacement of ERG11 mutant alleles with wild-type alleles, restored azole susceptibility to the levels measured for a parent azole-susceptible isolate (DSY294). These sequential genetic manipulations not only demonstrated that these two resistance mechanisms were those responsible for the development of resistance in DSY296 but also indicated that the quantitative level of resistance as measured in vitro by MIC determinations was a function of the number of genetic resistance mechanisms operating in any strain. The engineered strains were also tested for their responses to fluconazole treatment in a novel 3-day model of invasive C. albicans infection of mice. Fifty percent effective doses (ED(50)s) of fluconazole were highest for DSY296 and decreased proportionally with the sequential removal of each resistance mechanism. However, while the fold differences in ED(50) were proportional to the fold differences in MICs, their magnitude was lower than that measured in vitro and depended on the specific resistance mechanism operating.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This article presents the Antenatal Perceived Stress Inventory. The originality of this scale is to assess the impact of events experienced during pregnancy on the stress perceived by mothers. Scale validation was performed using data from 150 French-speaking nulliparous mothers and collected between 36 and 39 weeks of gestation (T1), and between 2 days (T2) and 6 weeks postpartum (T3). Factor analysis revealed a hierarchical three-factor structure that closely fit the data, including medical and obstetric risks/fetal health (F1), psychosocial changes (F2), and the prospect of childbirth (F3). The Antenatal Perceived Stress Inventory is a valid French prenatal stress scale with good psychometric properties.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Study design:Cross-sectional validation study.Objectives:To develop and validate a self-report version of the Spinal Cord Independence Measure (SCIM III).Setting:Two SCI rehabilitation facilities in Switzerland.Methods:SCIM III comprises 19 questions on daily tasks with a total score between 0 and 100 and subscales for 'self-care', 'respiration & sphincter management' and 'mobility'. A self-report version (SCIM-SR) was developed by expert discussions and pretests in individuals with spinal cord injury (SCI) using a German translation. A convenience sample of 99 inpatients with SCI was recruited. SCIM-SR data were analyzed together with SCIM III data obtained from attending health professionals.Results:High correlations between SCIM III and SCIM-SR were observed. Pearson's r for the total score was 0.87 (95% confidence interval (CI) 0.82-0.91), for the subscales self-care 0.87 (0.81-0.91); respiration & sphincter management 0.81 (0.73-0.87); and mobility 0.87 (0.82-0.91). Intraclass correlations were: total score 0.90 (95% CI 0.85-0.93); self-care 0.86 (0.79-0.90); respiration & sphincter management 0.80 (0.71-0.86); and mobility 0.83 (0.76-0.89). Bland-Altman plots showed that patients rated their functioning higher than professionals, in particular for mobility. The mean difference between SCIM-SR and SCIM III for the total score was 5.14 (point estimate 95% CI 2.95-7.34), self-care 0.89 (0.19-1.59), respiration & sphincter management 1.05 (0.18-2.28 ) and mobility 3.49 (2.44-4.54). Particularly patients readmitted because of pressure sores rated their independence higher than attending professionals.Conclusion:Our results support the criterion validity of SCIM-SR. The self-report version may facilitate long-term evaluations of independence in persons with SCI in their home situation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study examined the validity and reliability of the French version of two observer-rated measures developed to assess cognitive errors (cognitive errors rating system [CERS]) [6] and coping action patterns (coping action patterns rating system [CAPRS]) [22,24]. The CE measures 14 cognitive errors, broken down according to their valence positive or negative (see the definitions by A.T. Beck), and the CAP measures 12 coping categories, based on an comprehensive review literature, each broken down into three levels of action (affective, behavioural, cognitive). Thirty (N = 30) subjects recruited in a community sample participated in the study. They were interviewed according to a standardized clinical protocol: these interviews were transcribed and analysed with both observer-rated systems. Results showed that the inter-rater reliability of the two measures is good and that their internal validity is satisfactory, due to a non-significant canonical correlation between CAP and CE. With regard to discriminant validity, we found a non-significant canonical correlation between CAPRS and CISS, one of most widely used self-report questionnaire measuring coping. The same can be said for the correlation with a self-report questionnaire measuring symptoms (SCL-90-R). These results confirm the absence of confounds in the assessment of cognitive errors and of coping as assessed by these observer-rated scales and add an argument in favour of the French validation of the CE-CAP rating scales. (C) 2010 Elsevier Masson SAS. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background The PEmb-QoL is a validated 40-item questionnaire to quantify health-related quality of life in patients having experienced pulmonary embolism (PE). It covers six health dimensions: frequency of complaints, activities of daily living limitations, work-related problems, social limitations, intensity of complaints, and emotional complaints. Originally developed in Dutch and English, we sought to prospectively validate the psychometric properties of a French version of the PEmb-QoL.MethodsWe performed a forward and backward translation of the English version of the PEmb-QoL into French. French-speaking consecutive adult patients with an acute, objectively confirmed PE admitted to the emergency department of a Swiss university hospital between 08/2009 and 09/2011 were recruited telephonically. We used standard psychometric tests and criteria to evaluate the acceptability, reliability, and validity of the French version of the PEmb-QoL. We also performed an exploratory factor analysis.ResultsOverall, 102 patients were enrolled in the study. The French version of the PEmb-QoL showed good reliability (internal consistency, item¿total and inter-item correlations), reproducibility (test-retest reliability), and validity (convergent, discriminant) in French-speaking patients with PE. The exploratory factor analysis suggested three underlying dimensions: limitations in daily activity (items 4b-m, 5a-d), symptoms (items 1a-h and 7), and emotional complaints (items 9a-f and j).ConclusionWe successfully validated the French version of the PEmb-QoL questionnaire in patients with PE. Our results show that the PEmb-QoL is a valuable tool for assessing health-related quality of life after PE in French-speaking patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Training new doctors in general internal medicine represents a challenge. This requires to define future needs, which result from interest that are not necessarily convergent between patients, doctors, insurers and politicians. Problems related to medical demography in Switzerland, with the ageing of the population, the increase in health care costs and the place of Switzerland within the European Community require the implementation of specific objectives to train new physicians in general internal medicine. The success of these opportunities depends on social factors, political choices and choices from physician's association. In this article we will approach these challenges by formulating some proposals--nonexhaustive--in order to guarantee sufficient renewal in general internal medicine.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Practice guidelines for examining febrile patients presenting upon returning from the tropics were developed to assist primary care physicians in decision making. Because of the low level of evidence available in this field, there was a need to validate them and assess their feasibility in the context they have been designed for. OBJECTIVES: The objectives of the study were to (1) evaluate physicians' adherence to recommendations; (2) investigate reasons for non-adherence; and (3) ensure good clinical outcome of patients, the ultimate goal being to improve the quality of the guidelines, in particular to tailor them for the needs of the target audience and population. METHODS: Physicians consulting the guidelines on the Internet (www.fevertravel.ch) were invited to participate in the study. Navigation through the decision chart was automatically recorded, including diagnostic tests performed, initial and final diagnoses, and clinical outcomes. The reasons for non-adherence were investigated and qualitative feedback was collected. RESULTS: A total of 539 physician/patient pairs were included in this study. Full adherence to guidelines was observed in 29% of the cases. Figure-specific adherence rate was 54.8%. The main reasons for non-adherence were as follows: no repetition of malaria tests (111/352) and no presumptive antibiotic treatment for febrile diarrhea (64/153) or abdominal pain without leukocytosis (46/101). Overall, 20% of diversions from guidelines were considered reasonable because there was an alternative presumptive diagnosis or the symptoms were mild, which means that the corrected adherence rate per case was 40.6% and corrected adherence per figure was 61.7%. No death was recorded and all complications could be attributed to the underlying illness rather than to adherence to guidelines. CONCLUSIONS: These guidelines proved to be feasible, useful, and leading to good clinical outcomes. Almost one third of physicians strictly adhered to the guidelines. Other physicians used the guidelines not to forget specific diagnoses but finally diverged from the proposed attitudes. These diversions should be scrutinized for further refinement of the guidelines to better fit to physician and patient needs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conventional methods of gene prediction rely on the recognition of DNA-sequence signals, the coding potential or the comparison of a genomic sequence with a cDNA, EST, or protein database. Reasons for limited accuracy in many circumstances are species-specific training and the incompleteness of reference databases. Lately, comparative genome analysis has attracted increasing attention. Several analysis tools that are based on human/mouse comparisons are already available. Here, we present a program for the prediction of protein-coding genes, termed SGP-1 (Syntenic Gene Prediction), which is based on the similarity of homologous genomic sequences. In contrast to most existing tools, the accuracy of SGP-1 depends little on species-specific properties such as codon usage or the nucleotide distribution. SGP-1 may therefore be applied to nonstandard model organisms in vertebrates as well as in plants, without the need for extensive parameter training. In addition to predicting genes in large-scale genomic sequences, the program may be useful to validate gene structure annotations from databases. To this end, SGP-1 output also contains comparisons between predicted and annotated gene structures in HTML format. The program can be accessed via a Web server at http://soft.ice.mpg.de/sgp-1. The source code, written in ANSI C, is available on request from the authors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Descriptors based on Molecular Interaction Fields (MIF) are highly suitable for drug discovery, but their size (thousands of variables) often limits their application in practice. Here we describe a simple and fast computational method that extracts from a MIF a handful of highly informative points (hot spots) which summarize the most relevant information. The method was specifically developed for drug discovery, is fast, and does not require human supervision, being suitable for its application on very large series of compounds. The quality of the results has been tested by running the method on the ligand structure of a large number of ligand-receptor complexes and then comparing the position of the selected hot spots with actual atoms of the receptor. As an additional test, the hot spots obtained with the novel method were used to obtain GRIND-like molecular descriptors which were compared with the original GRIND. In both cases the results show that the novel method is highly suitable for describing ligand-receptor interactions and compares favorably with other state-of-the-art methods.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: Cardiovascular magnetic resonance (CMR) has become a robust and important diagnostic imaging modality in cardiovascular medicine. However,insufficient image quality may compromise its diagnostic accuracy. No standardized criteria are available to assess the quality of CMR studies. We aimed todescribe and validate standardized criteria to evaluate the quality of CMR studies including: a) cine steady-state free precession, b) delayed gadoliniumenhancement, and c) adenosine stress first-pass perfusion. These criteria will serve for the assessment of the image quality in the setting of the Euro-CMR registry.METHOD AND MATERIALS: First, a total of 45 quality criteria were defined (35 qualitative criteria with a score from 0-3, and 10 quantitative criteria). Thequalitative score ranged from 0 to 105. The lower the qualitative score, the better the quality. The quantitative criteria were based on the absolute signal intensity (delayed enhancement) and on the signal increase (perfusion) of the anterior/posterior left ventricular wall after gadolinium injection. These criteria were then applied in 30 patients scanned with a 1.5T system and in 15 patients scanned with a 3.0T system. The examinations were jointly interpreted by 3 CMR experts and 1 study nurse. In these 45 patients the correlation between the results of the quality assessment obtained by the different readers was calculated.RESULTS: On the 1.5T machine, the mean quality score was 3.5. The mean difference between each pair of observers was 0.2 (5.7%) with a mean standarddeviation of 1.4. On the 3.0T machine, the mean quality score was 4.4. The mean difference between each pair of onservers was 0.3 (6.4%) with a meanstandard deviation of 1.6. The quantitative quality assessments between observers were well correlated for the 1.5T machine: R was between 0.78 and 0.99 (pCONCLUSION: The described criteria for the assessment of CMR image quality are robust and have a low inter-observer variability, especially on 1.5T systems.CLINICAL RELEVANCE/APPLICATION: These criteria will allow the standardization of CMR examinations. They will help to improve the overall quality ofexaminations and the comparison between clinical studies.