906 resultados para user interface design


Relevância:

90.00% 90.00%

Publicador:

Resumo:

This thesis research describes the design and implementation of a Semantic Geographic Information System (GIS) and the creation of its spatial database. The database schema is designed and created, and all textual and spatial data are loaded into the database with the help of the Semantic DBMS's Binary Database Interface currently being developed at the FIU's High Performance Database Research Center (HPDRC). A friendly graphical user interface is created together with the other main system's areas: displaying process, data animation, and data retrieval. All these components are tightly integrated to form a novel and practical semantic GIS that has facilitated the interpretation, manipulation, analysis, and display of spatial data like: Ocean Temperature, Ozone(TOMS), and simulated SeaWiFS data. At the same time, this system has played a major role in the testing process of the HPDRC's high performance and efficient parallel Semantic DBMS.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

This poster presentation features three route planning applications developed by the Florida International University GIS Center and the Geomatics program at the University of Florida, and outlines their context based differences. The first route planner has been developed for cyclists in three Florida counties, i.e. Miami Dade County, Broward County, and Palm Beach County. The second route planner computes safe pedestrian routes to schools and has been developed for Miami Dade County. The third route planner combines pre-compiled cultural/eco routes and point-to-point route planning for the City of Coral Gables. This poster highlights the differences in design (user interface) and implementation (routing options) between the three route planners as a result of a different application context and target audience.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Stroke is nowadays one of the main causes of death in Brazil and worldwide. During the rehabilitation process, patients undergo physioterapic exercises based on repetition, which may cause them to feel little progress is being made. Focusing on themes from the areas of Human-Computer Interaction and Motor Imagery, the present work describes the development of a digital game concept aimed at motor rehabilitation to the neural rehabilitation of patients who have suffered a stroke in a playful and engaging way. The research hypothesizes that an interactive digital game based on Motor Imagery contributes to patients' raised commitment in the stroke sequel rehabilitation process. The research process entailed the investigation of 10 subjects who live with sequels caused by stroke - it was further established that subjects were over 60 years old. Using as foundation an initial survey regarding target-users' specificities, where an investigation on subjectrelated aspects was carried out through Focus Group (n=9) and Contextual Analysis (n=3), having as subjects elderly individuals, a list with the necessary requirements for the conceptualization of a digital game was fleshed out. The initial survey also enabled the establishment of preliminary interactions for the formulation of game prototypes. At first, low-resolution prototypes were used, with two distinct interaction models for the game - one with a direct approach to the Motor Imagery concept, and another using a narrative with characters and scene settings. The goal was to verify participants' receptivity regarding the addition of playful activities into game dynamics. Prototypes were analyzed while being used by five patients, through the Cooperative Evaluation technique. The tests indicated a preference for option with elements in a playful narrative. Based on these results high fidelity prototypes were created, where concepts close to the game's final version were elaborated. The High Fidelity prototype was also evaluated with four patients through the Cooperative Evaluation technique. It was concluded that elderly individuals and patients were receptive to the idea of a digital game for the rehabilitation from sequels caused by stroke; that, for the success of devices aimed at these cohorts, their contexts, needs and expectations must be respected above all; and that user-centered design is an essential approach in that regard.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Funding for this study was received from the Chief Scientist Office for Scotland. We would like to thank Asthma UK and Asthma UK Scotland for facilitating the advertisement of the study pilot and consultative user group. Thanks to Dr Mark Grindle for his helpful discussions concerning narrative. Thanks also to Mr Mark Haldane who designed the characters, backgrounds, and user interface used within the 3D computer animation. Particular thanks to the participants of the consultative user group for their enthusiasm, comments, and suggestions at all stages of the intervention design.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

A RET network consists of a network of photo-active molecules called chromophores that can participate in inter-molecular energy transfer called resonance energy transfer (RET). RET networks are used in a variety of applications including cryptographic devices, storage systems, light harvesting complexes, biological sensors, and molecular rulers. In this dissertation, we focus on creating a RET device called closed-diffusive exciton valve (C-DEV) in which the input to output transfer function is controlled by an external energy source, similar to a semiconductor transistor like the MOSFET. Due to their biocompatibility, molecular devices like the C-DEVs can be used to introduce computing power in biological, organic, and aqueous environments such as living cells. Furthermore, the underlying physics in RET devices are stochastic in nature, making them suitable for stochastic computing in which true random distribution generation is critical.

In order to determine a valid configuration of chromophores for the C-DEV, we developed a systematic process based on user-guided design space pruning techniques and built-in simulation tools. We show that our C-DEV is 15x better than C-DEVs designed using ad hoc methods that rely on limited data from prior experiments. We also show ways in which the C-DEV can be improved further and how different varieties of C-DEVs can be combined to form more complex logic circuits. Moreover, the systematic design process can be used to search for valid chromophore network configurations for a variety of RET applications.

We also describe a feasibility study for a technique used to control the orientation of chromophores attached to DNA. Being able to control the orientation can expand the design space for RET networks because it provides another parameter to tune their collective behavior. While results showed limited control over orientation, the analysis required the development of a mathematical model that can be used to determine the distribution of dipoles in a given sample of chromophore constructs. The model can be used to evaluate the feasibility of other potential orientation control techniques.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The observation chart is for many health professionals (HPs) the primary source of objective information relating to the health of a patient. Information Systems (IS) research has demonstrated the positive impact of good interface design on decision making and it is logical that good observation chart design can positively impact healthcare decision making. Despite the potential for good observation chart design, there is a paucity of observation chart design literature, with the primary source of literature leveraging Human Computer Interaction (HCI) literature to design better charts. While this approach has been successful, this design approach introduces a gap between understanding of the tasks performed by HPs when using charts and the design features implemented in the chart. Good IS allow for the collection and manipulation of data so that it can be presented in a timely manner that support specific tasks. Good interface design should therefore consider the specific tasks being performed prior to designing the interface. This research adopts a Design Science Research (DSR) approach to formalise a framework of design principles that incorporates knowledge of the tasks performed by HPs when using observation charts and knowledge pertaining to visual representations of data and semiology of graphics. This research is presented in three phases, the initial two phases seek to discover and formalise design knowledge embedded in two situated observation charts: the paper-based NEWS chart developed by the Health Service Executive in Ireland and the electronically generated eNEWS chart developed by the Health Information Systems Research Centre in University College Cork. A comparative evaluation of each chart is also presented in the respective phases. Throughout each of these phases, tentative versions of a design framework for electronic vital sign observation charts are presented, with each subsequent iteration of the framework (versions Alpha, Beta, V0.1 and V1.0) representing a refinement of the design knowledge. The design framework will be named the framework for the Retrospective Evaluation of Vital Sign Information from Early Warning Systems (REVIEWS). Phase 3 of the research presents the deductive process for designing and implementing V0.1 of the framework, with evaluation of the instantiation allowing for the final iteration V1.0 of the framework. This study makes a number of contributions to academic research. First the research demonstrates that the cognitive tasks performed by nurses during clinical reasoning can be supported through good observation chart design. Secondly the research establishes the utility of electronic vital sign observation charts in terms of supporting the cognitive tasks performed by nurses during clinical reasoning. Third the framework for REVIEWS represents a comprehensive set of design principles which if applied to chart design will improve the usefulness of the chart in terms of supporting clinical reasoning. Fourth the electronic observation chart that emerges from this research is demonstrated to be significantly more useful than previously designed charts and represents a significant contribution to practice. Finally the research presents a research design that employs a combination of inductive and deductive design activities to iterate on the design of situated artefacts.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The inherent analogue nature of medical ultrasound signals in conjunction with the abundant merits provided by digital image acquisition, together with the increasing use of relatively simple front-end circuitries, have created considerable demand for single-bit  beamformers in digital ultrasound imaging systems. Furthermore, the increasing need to design lightweight ultrasound systems with low power consumption and low noise, provide ample justification for development and innovation in the use of single-bit  beamformers in ultrasound imaging systems. The overall aim of this research program is to investigate, establish, develop and confirm through a combination of theoretical analysis and detailed simulations, that utilize raw phantom data sets, suitable techniques for the design of simple-to-implement hardware efficient  digital ultrasound beamformers to address the requirements for 3D scanners with large channel counts, as well as portable and lightweight ultrasound scanners for point-of-care applications and intravascular imaging systems. In addition, the stability boundaries of higher-order High-Pass (HP) and Band-Pass (BP) Σ−Δ modulators for single- and dual- sinusoidal inputs are determined using quasi-linear modeling together with the describing-function method, to more accurately model the  modulator quantizer. The theoretical results are shown to be in good agreement with the simulation results for a variety of input amplitudes, bandwidths, and modulator orders. The proposed mathematical models of the quantizer will immensely help speed up the design of higher order HP and BP Σ−Δ modulators to be applicable for digital ultrasound beamformers. Finally, a user friendly design and performance evaluation tool for LP, BP and HP  modulators is developed. This toolbox, which uses various design methodologies and covers an assortment of  modulators topologies, is intended to accelerate the design process and evaluation of  modulators. This design tool is further developed to enable the design, analysis and evaluation of  beamformer structures including the noise analyses of the final B-scan images. Thus, this tool will allow researchers and practitioners to design and verify different reconstruction filters and analyze the results directly on the B-scan ultrasound images thereby saving considerable time and effort.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

In this thesis, novel analog-to-digital and digital-to-analog generalized time-interleaved variable bandpass sigma-delta modulators are designed, analysed, evaluated and implemented that are suitable for high performance data conversion for a broad-spectrum of applications. These generalized time-interleaved variable bandpass sigma-delta modulators can perform noise-shaping for any centre frequency from DC to Nyquist. The proposed topologies are well-suited for Butterworth, Chebyshev, inverse-Chebyshev and elliptical filters, where designers have the flexibility of specifying the centre frequency, bandwidth as well as the passband and stopband attenuation parameters. The application of the time-interleaving approach, in combination with these bandpass loop-filters, not only overcomes the limitations that are associated with conventional and mid-band resonator-based bandpass sigma-delta modulators, but also offers an elegant means to increase the conversion bandwidth, thereby relaxing the need to use faster or higher-order sigma-delta modulators. A step-by-step design technique has been developed for the design of time-interleaved variable bandpass sigma-delta modulators. Using this technique, an assortment of lower- and higher-order single- and multi-path generalized A/D variable bandpass sigma-delta modulators were designed, evaluated and compared in terms of their signal-to-noise ratios, hardware complexity, stability, tonality and sensitivity for ideal and non-ideal topologies. Extensive behavioural-level simulations verified that one of the proposed topologies not only used fewer coefficients but also exhibited greater robustness to non-idealties. Furthermore, second-, fourth- and sixth-order single- and multi-path digital variable bandpass digital sigma-delta modulators are designed using this technique. The mathematical modelling and evaluation of tones caused by the finite wordlengths of these digital multi-path sigmadelta modulators, when excited by sinusoidal input signals, are also derived from first principles and verified using simulation and experimental results. The fourth-order digital variable-band sigma-delta modulator topologies are implemented in VHDL and synthesized on Xilinx® SpartanTM-3 Development Kit using fixed-point arithmetic. Circuit outputs were taken via RS232 connection provided on the FPGA board and evaluated using MATLAB routines developed by the author. These routines included the decimation process as well. The experiments undertaken by the author further validated the design methodology presented in the work. In addition, a novel tunable and reconfigurable second-order variable bandpass sigma-delta modulator has been designed and evaluated at the behavioural-level. This topology offers a flexible set of choices for designers and can operate either in single- or dual-mode enabling multi-band implementations on a single digital variable bandpass sigma-delta modulator. This work is also supported by a novel user-friendly design and evaluation tool that has been developed in MATLAB/Simulink that can speed-up the design, evaluation and comparison of analog and digital single-stage and time-interleaved variable bandpass sigma-delta modulators. This tool enables the user to specify the conversion type, topology, loop-filter type, path number and oversampling ratio.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Esta investigación aborda el consumo que los jóvenes universitarios de España y Brasil realizan de las publicaciones para tabletas. A través del estudio de seis casos –las revistas españolas Don, VisàVis y Quality Sport, y los vespertinos brasileños O Globo a Mais, de Río de Janeiro; Estadão Noite, de Sao Paulo; y Diário do Nordeste Plus, de Fortaleza– se aplica una metodología cualitativa, el test de usabilidad, para detectar qué aspectos ralentizan y entorpecen la navegación en las nuevas generaciones de usuarios de medios móviles. A pesar de la influencia de las revistas impresas en la configuración de las publicaciones para tableta, los datos muestran que el usuario necesita “entrenarse” para conocer unas opciones de interacción a veces poco intuitivas o para las que carece de la madurez visual necesaria. Por ello las publicaciones más sencillas obtienen los mejores resultados de usabilidad.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

During the development of a new treatment space for the UK emergency ambulance participatory observations with front-line clinicians revealed the need for an integrated patient monitoring, communication and navigation system. The research identified the different information touch-points and requirements through modes of use analysis, day-in-the-life study and simulation workshops with clinicians. Emergency scenario and role-play with paramedics identified 5 distinct ambulance modes of use. Information flow diagrams were created and checked by paramedics and digital User Interface (UI) wireframes were developed and evaluated by clinicians during clinical evaluations. Feedback from clinicians defined UI design specification further leading to a final design proposal. This research was a further development from the 2007 EPSRC funded “Smart Pods” project. The resulting interactive prototype was co-designed in collaboration with ambulance crews and provides a vision of what could be achieved by integrating well-proven IT technologies and protocols into a package relevant in the emergency medicine field. The system has been reviewed by over 40 ambulance crews and is part of a newly co-designed ambulance treatment space.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Chicken Run, an experimental project still in development, sees designers and scientists working together to explore ideas to improve poultry welfare in commercial facilities, applying user-centred design to all key stakeholders: farmer, consumer and chicken. Exploring various aspects of the chicken’s journey from egg to plate, the process has allowed researchers to better understand their needs and to maximise joined-up positive impact. The paper describes the ongoing process where Initial proposals including perches, bales and an app to enable consumers to make the right chicken purchase choices have been developed and tested. Co-authored by leaders of the design and scientific communities involved in the project, the paper describes the issues, design methods used, as well as some of the learning from the cross-disciplinary process. It also provides an update on progress of selected design ideas that are currently being developed with a commercial poultry farm, drawing out the challenges and successes encountered.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

In modern society, the body health is a very important issue to everyone. With the development of the science and technology, the new and developed body health monitoring device and technology will play the key role in the daily medical activities. This paper focus on making progress in the design of the wearable vital sign system. A vital sign monitoring system has been proposed and designed. The whole detection system is composed of signal collecting subsystem, signal processing subsystem, short-range wireless communication subsystem and user interface subsystem. The signal collecting subsystem is composed of light source and photo diode, after emiting light of two different wavelength, the photo diode collects the light signal reflected by human body tissue. The signal processing subsystem is based on the analog front end AFE4490 and peripheral circuits, the collected analog signal would be filtered and converted into digital signal in this stage. After a series of processing, the signal would be transmitted to the short-range wireless communication subsystem through SPI, this subsystem is mainly based on Bluetooth 4.0 protocol and ultra-low power System on Chip(SoC) nRF51822. Finally, the signal would be transmitted to the user end. After proposing and building the system, this paper focus on the research of the key component in the system, that is, the photo detector. Based on the study of the perovskite materials, a low temperature processed photo detector has been proposed, designed and researched. The device is made up of light absorbing layer, electron transporting and hole blocking layer, hole transporting and electron blocking layer, conductive substrate layer and metal electrode layer. The light absorbing layer is the important part of whole device, and it is fabricated by perovskite materials. After accepting the light, the electron-hole pair would be produced in this layer, and due to the energy level difference, the electron and hole produced would be transmitted to metal electrode and conductive substrate electrode through electron transporting layer and hole transporting layer respectively. In this way the response current would be produced. Based on this structure, the specific fabrication procedure including substrate cleaning; PEDOT:PSS layer preparation; pervoskite layer preparation; PCBM layer preparation; C60, BCP, and Ag electrode layer preparation. After the device fabrication, a series of morphological characterization and performance testing has been done. The testing procedure including film-forming quality inspection, response current and light wavelength analysis, linearity and response time and other optical and electrical properties testing. The testing result shows that the membrane has been fabricated uniformly; the device can produce obvious response current to the incident light with the wavelength from 350nm to 800nm, and the response current could be changed along with the light wavelength. When the light wavelength keeps constant, there exists a good linear relationship between the intensity of the response current and the power of the incident light, based on which the device could be used as the photo detector to collect the light information. During the changing period of the light signal, the response time of the device is several microseconds, which is acceptable working as a photo detector in our system. The testing results show that the device has good electronic and optical properties, and the fabrication procedure is also repeatable, the properties of the devices has good uniformity, which illustrates the fabrication method and procedure could be used to build the photo detector in our wearable system. Based on a series of testing results, the paper has drawn the conclusion that the photo detector fabricated could be integrated on the flexible substrate and is also suitable for the monitoring system proposed, thus made some progress on the research of the wearable monitoring system and device. Finally, some future prospect in system design aspect and device design and fabrication aspect are proposed.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Bikeshares promote healthy lifestyles and sustainability among commuters, casual riders, and tourists. However, the central pillar of modern systems, the bike station, cannot be easily integrated into a compact college campus. Fixed stations lack the flexibility to meet the needs of college students who make quick, short-distance trips. Additionally, the necessary cost of implementing and maintaining each station prohibits increasing the number of stations for user convenience. Therefore, the team developed a stationless bikeshare based on a smartlock permanently attached to bicycles in the system. The smartlock system design incorporates several innovative approaches to provide usability, security, and reliability that overcome the limitations of a station centered design. A focus group discussion allowed the team to receive feedback on the early lock, system, and website designs, identify improvements and craft a pleasant user experience. The team designed a unique, two-step lock system that is intuitive to operate while mitigating user error. To ensure security, user access is limited through near field ii communications (NFC) technology connected to a mechatronic release system. The said system relied on a NFC module and a servo working through an Arduino microcontroller coded in the Arduino IDE. To track rentals and maintain the system, each bike is fitted with an XBee module to communicate with a scalable ZigBee mesh network. The network allows for bidirectional, real-time communication with a Meteor.js web application, which enables user and administrator functions through an intuitive user interface available on mobile and desktop. The development of an independent smartlock to replace bike stations is essential to meet the needs of the modern college student. With the goal of creating a bikeshare that better serves college students, Team BIKES has laid the framework for a system that is affordable, easily adaptable, and implementable on any university expressing an interest in bringing a bikeshare to its campus.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

A inovação tecnológica e as facilidades que gera tem tido um impacto crescente em diversas área, inclusivamente na medicina. A rápida evolução por parte de algumas tecnologias, como é o caso da Realidade Aumentada (RA), criam excelentes oportunidades, nomeadamente para intervenções cirúrgicas laparoscópicas, que apresentam especialmente problemas ao nível da exposição do doente a radiação. O presente documento detalha todo o processo de investigação e desenvolvimento realizado com a pretensão de criar um sistema de navegação por RA que auxilie o procedimento cirúrgico laparoscópico de remoção de pedras nos rins. Com este objetivo em perspetiva, e numa parceria com a empresa ECmedica LTD, foram desenvolvidos quatro protótipo funcionais. Com o intuito de compreender as melhores práticas de sistemas de input, interface e sistema de registo a aplicar, estes integraram aspetos inovadores tais como a utilização de uma sonda ultra-som, como substituta do raioX, e um registo feito através de sensores magnéticos. Apoiados numa metodologia de design centrado no utilizador e em instrumentos de análise como entrevistas e observação natural, os protótipos foram testados, obtendo respostas esclarecedoras relativamente ao objetivos dos protótipos. Foi observado que a RA é vista pelos médicos como uma solução com potencial, com as soluções apresentadas ao nível de inputs, interface e registo a serem bem recebidas. A projeção bidimensional oferecida pela imagem ultra-som foi encarada como insuficientes, sendo sugerida a sua substituição por um aumento tridimensional capaz de facilitar a correta inserção da agulha.