994 resultados para transmission measurement


Relevância:

20.00% 20.00%

Publicador:

Resumo:

To investigate the ability of ultrasonography to estimate musactivity, we measured architectural parameters (pennation angles, fascicle lengths, and muscle thickness) of several human muscles (tibialis anterior, biceps brachii, brachialis, transversus abdominis, obliquus internus abdominis, and obliquus externus abdominis) during isometric contractions of from 0 to 100% maximal voluntary contraction (MVC). Concurrently, electromyographic (EMG) activity was measured with surface (tibialis anterior only) or fine-wire electrodes. Most architectural parameters changed markedly with contractions up to 30% MVC but changed little at higher levels of contraction. Thus, ultrasound imaging can be used to detect low levels of muscle activity but cannot discriminate between moderate and strong contractions. Ultrasound measures could reliably detect changes in EMG of as little as 4% MVC (biceps muscle thickness), 5% MVC (brachialis muscle thickness), or 9% MVC (tibialis anterior pennation angle). They were generally less sensitive to changes in abdominal muscle activity, but it was possible to reliably detect contractions of 12% MVC in transversus abdominis (muscle length) and 22% MVC in obliquus internus (muscle thickness). Obliquus externus abdominis thickness did not change consistently with muscle contraction, so ultrasound measures of thickness cannot be used to detect activity of this muscle. Ultrasound imaging can thus provide a non-invasive method of detecting isometric muscle contractions of certain individual muscles.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a review of the time-domain polarization measurement techniques for the condition assessment of aged transformer insulation. The polarization process is first described with appropriate dielectric response theories and then commonly used polarization methods are described with special emphasis on the most widely used return voltage(rv) measurement. Most recent emphasis has been directed to techniques of determining moisture content of insulation indirectly by measuring rv parameters. The major difficulty still lies with the accurate interpretation of return voltage results. This paper investigates different thoughts regarding the interpretation of rv results for different moisture and ageing conditions. Other time domain polarization measurement techniques and their results are also presented in this paper.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Frequency deviation is a common problem for power system signal processing. Many power system measurements are carried out in a fixed sampling rate assuming the system operates in its nominal frequency (50 or 60 Hz). However, the actual frequency may deviate from the normal value from time to time due to various reasons such as disturbances and subsequent system transients. Measurement of signals based on a fixed sampling rate may introduce errors under such situations. In order to achieve high precision signal measurement appropriate algorithms need to be employed to reduce the impact from frequency deviation in the power system data acquisition process. This paper proposes an advanced algorithm to enhance Fourier transform for power system signal processing. The algorithm is able to effectively correct frequency deviation under fixed sampling rate. Accurate measurement of power system signals is essential for the secure and reliable operation of power systems. The algorithm is readily applicable to such occasions where signal processing is affected by frequency deviation. Both mathematical proof and numerical simulation are given in this paper to illustrate robustness and effectiveness of the proposed algorithm. Crown Copyright (C) 2003 Published by Elsevier Science B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to evaluate and establish the mean values of IOP in healthy adult sheep using an applanation tonometer. Information on age, sex, and breed was obtained for all animals included in this study. Twenty five healthy sheep (Ovis aries), of the same breed (Texel), male or female, with three years of age, received an ophthalmic examination in both eyes, including pupillary reflexes, Schirmer tear test, slit lamp biomicroscopy, and fluorescein staining. For all ophthalmic testing, animals were gently physically restrained, with no pressure in the jugular area and the eyelids were carefully open. IOP was measured by applanation tonometry (Tonopen XL). The same examiner performed the tonometry; measurements were taken three times for each eye, and their average was recorded as the IOP of the animal. Statistical analysis was performed using paired t-test and values of P < 0.05 were considered significant. The mean intraocular pressure in the whole group of 50 eyes was of 16.36 +/- 2.19 mm Hg. The mean (SD) IOP in the right eye was of 15.96 +/- 2.02 mm Hg, while the mean (SD) IOP in the left eye was of 16.76 +/- 2.32 mm Hg. Significant differences in IOP were not found between right and left eyes. The applanation tonometer was adequate for measuring the intraocular pressure in sheep. Reference data will assist in diagnosing testing for ophthalmic disease in sheep, as¹ well as promote further studies in this area.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Performance measurement of police services is complicated by ambiguous and complex goal- and objectives-setting, and by the difficulties of measuring outputs. This article looks at the organizational and management changes being made in Portuguese police forces. The authors fill a gap in the literature on performance measurement in Portugal by taking a national approach to the study of how law enforcement agencies are introducing new management accounting changes. The article therefore widens the debate on performance measurement and performance improvements in law enforcement.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Websites are, nowadays, the face of institutions, but they are often neglected, especially when it comes to contents. In the present paper, we put forth an investigation work whose final goal is the development of a model for the measurement of data quality in institutional websites for health units. To that end, we have carried out a bibliographic review of the available approaches for the evaluation of website content quality, in order to identify the most recurrent dimensions and the attributes, and we are currently carrying out a Delphi Method process, presently in its second stage, with the purpose of reaching an adequate set of attributes for the measurement of content quality.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Many public organisations have been under great pressure in recent years to increase the efficiency and transparency of outputs, to rationalise the use of public resources, and to increase the quality of service delivery. In this context, public organisations were encouraged to introduce the New Public Management reforms with the goal of improving the efficiency and effectiveness of the performance organisation through a new public management model. This new public management model is based on measurement by outputs and outcomes, a clear definition of responsibilities, the transparency and accountability of governmental activities, and on a greater value for citizens. What type of performance measurement systems are used in police services? Based on the literature, we see that multidimensional models, such as the Balanced Scorecard, are important in many public organisations, like municipalities, universities, and hospitals. Police services are characterised by complex, diverse objectives and stakeholders. Therefore, performance measurement of these public services calls for a specific analysis. Based on a nationwide survey of all police chiefs of the Portuguese police force, we find that employee performance measurement is the main form of measurement. Also, we propose a strategic map for the Portuguese police service.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In order to obtain evidence on the size of the impact of the Hong Kong/68 variant of influenza A2 virus on the population of São Paulo, Brazil, serum samples taken in 1967 before this variant appeared and during successive years after it appeared were examined for their antibody content. Haemagglutination-inhibition tests performed on a total of 2726 serum samples from adults showed a sharp decrease in 1969 of the proportion of sera without antibody to the Hong Kong/68 variant and a corresponding mercase in the proportion with high titres. It was concluded that about three-quarters of the adult population became infected at some time after the variant appeared, the majority in the first year of prevalence.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper we present results on the optimization of multilayered a-SiC:H heterostructures that can be used as optical transducers for fluorescent proteins detection using the Fluorescence Resonance Energy Transfer approach. Double structures composed by pin based aSiC:H cells are analyzed. The color discrimination is achieved by ac photocurrent measurement under different externally applied bias. Experimental data on spectral response analysis, current-voltage characteristics and color and transmission rate discrimination are reported. An electrical model, supported by a numerical simulation gives insight into the device operation. Results show that the optimized a-SiC:H heterostructures act as voltage controlled optical filters in the visible spectrum. When the applied voltages are chosen appropriately those optical transducers can detect not only the selective excitation of specimen fluorophores, but also the subsequent weak acceptor fluorescent channel emission.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O sector dos edifícios é responsável por uma percentagem significativa dos consumos de energia primária e de energia eléctrica em Portugal, associada principalmente ao conforto térmico dos seus ocupantes. A União Europeia pretende uma redução de 20%, até 2020, dos consumos de energia e consequentes emissões de CO2 através da melhoria da eficiência energética dos edifícios públicos e residenciais. Em Portugal, o Plano Nacional para a Eficiência Energética (PNAEE) tem por objectivo obter uma poupança anual de energia de pelo menos 1% até ao ano de 2016, tomando como base a média de consumos de energia final, registados entre 2001 e 2005. Neste contexto, os edifícios anteriores a 1990 (primeira versão do RCCTE) podem apresentar um potencial significativo de melhoria da sua eficiência energética com base na sua reabilitação. Os edifícios “Gaioleiros” (1880 – 1930) constituindo uma parte importante do património histórico da cidade de Lisboa, para os quais a informação sobre o seu desempenho térmico é limitada, considerou-se pertinente efectuar um estudo destinado à sua caracterização experimental e numérica, face à especificidade do comportamento térmico das suas paredes caracterizadas pela elevada espessura. No presente trabalho, apresenta-se a metodologia e os resultados experimentais da medição da resistência térmica das paredes e da medição das necessidades térmicas de aquecimento da habitação. Estes resultados experimentais foram utilizados na validação do modelo de simulação térmica da habitação, que posteriormente serviu para avaliar as suas necessidades térmicas de aquecimento (Nic) e de arrefecimento (Nvc), identificar oportunidades de melhoria e avaliar o respectivo potencial de reabilitação. Neste trabalho, como contributos para uma reabilitação sustentável, apresentam-se avaliações de oportunidades de melhoria com base em estratégias de reforço do isolamento térmico. Dos resultados obtidos concluiu-se que melhorando o isolamento térmico das paredes e vãos envidraçados é possível baixar consideravelmente os consumos de energia associados à habitação, cumprindo assim as exigências estabelecidas no RCCTE ao nível dos requisitos de qualidade térmica da envolvente e consumos energéticos para edifícios novos e grandes reabilitações.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Este trabalho apresenta um estudo sobre o comportamento dinâmico das bicicletas com o principal objectivo de quantificar o conforto de um ciclista. Neste trabalho serão estudados dois tipos de bicicletas: uma apenas com suspensão dianteira e outra com suspensão dianteira e traseira (ou suspensão total), e três classes de pavimento: um mais sinuoso, um mais suave e um intermédio. Para cada uma destas situações o que se pretende é analisar a quantidade de vibração que é transmitida para o corpo do ciclista através dos três pontos de contacto existentes entre ambos: Assento, guiador e pedais. Os valores obtidos são comparados entre os vários casos e também com valores referência, fornecidos por normas, afim de analisar a situação de conforto do ciclista. Após a realização dos estudos o que se verificou é que o ciclista está numa situação mais desconfortável em pisos mais sinuosos, e que nesta situação se utilizar uma bicicleta de suspensão total está sujeito a vibrações inferiores. No entanto, o mais importante a concluir é que em qualquer uma das situações estudadas o ciclista encontra-se sempre dentro de uma zona conforto segundo as normas utilizadas.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The importance of Social Responsibility (SR) is higher if this business variable is related with other ones of strategic nature in business activity (competitive success that the company achieved, performance that the firms develop and innovations that they carries out). The hypothesis is that organizations that focus on SR are those who get higher outputs and innovate more, achieving greater competitive success. A scale for measuring the orientation to SR has defined in order to determine the degree of relationship between above elements. This instrument is original because previous scales do not exist in the literature which could measure, on the one hand, the three classics sub-constructs theoretically accepted that SR is made up and, on the other hand, the relationship between SR and the other variables. As a result of causal relationships analysis we conclude with a scale of 21 indicators, validated scale with a sample of firms belonging to the Autonomous Community of Extremadura and it is the first empirical validation of these dimensions we know so far, in this context.