998 resultados para test device


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: The present study aimed to investigate the feasibility and practicalities or testing children in special school settings using transient evoked otoacoustic emissions (TEOAE) and tympanometry. Children studying in special schools, particularly those with intellectual impairment, may be highly susceptible to hearing pathologies and can be difficult to assess using traditional test batteries. Researchers have recently suggested the possible applicability of TEOAE testing. in lieu of conventional behavioral methods, as a hearing screening device for persons with intellectual impairment. However, to date. few publications have detailed the particulars and results of such testing. Methods: A total of 489 children, with a mean age of 9.6 years, were tested in 15 special schools. Case information was obtained regarding birth history, medical history and type,degree of impairment, for later comparison with screening results. TEOAEs were collected using Quickscreen mode of the ILO292 Otodynamics Analyzer, whilst tympanometry was performed utilizing a Madsen Zodiac 901 Middle Ear Analyzer. Results: In total, 80% of students were able to be tested using TEOAEs. Average test time per ear was 2 min. However, a large proportion (40 of those able to be tested) failed TEOAE testing in at least one ear. No significant effects were found between could-not-test (CNT) cases and case history factors, A significant difference in TEOAE failure rates was found across history of neonatal special care nursery residency and history of parental concern regarding possible hearing impairment. Failure rates were higher for those who indicated positive histories. A total of 74% of subjects could be tested using tympanometry, with 25% of those able to be tested failing in at least one ear. Notably, neither type nor degree of impairment had any significant bearing on CNT or failure rates for tympanometry or TEOAE screening. Conclusions: Findings of the present investigation lend support to the review of hearing screening programs for children in special schools. with TEOAEs presenting as a potential alternative procedure. Further examination of the performance measures of protocols incorporating TEOAEs would now be advantageous. (C) 2002 Elsevier Science Ireland Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Involvement of nerve tissue may contribute to the persistence of pain following a whiplash injury. This study aimed to investigate responses to the brachial plexus provocation test (BPPT) in 156 subjects with chronic whiplash associated disorder (WAD) with and without associated arm pain and 95 asymptomatic control subjects. The range of elbow extension (ROM) and visual analogue scale (VAS) pain scores were measured. Subjects with chronic WAD demonstrated significantly less ROM and higher VAS scores with the BPPT than the asymptomatic subjects (P

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To establish a noncontagious control for the Ray thioglycollate test for the detection of Perkinsus in mollusks we evaluated nonviable stages of P. olseni for enlargement of hypnospores and blue/black iodine stain. Trophozoites made nonviable with formalin, irradiation or colchicine failed to swell in thioglycollate. They remained small and did not differentially stain in iodine. Trophozoites that had already developed into hypnospores in thioglycollate were rendered inactive by freezing, ethanol or formalin immersion. They retained their iodinophilic properties and thus could provide a partial control for the Ray Test.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A 20kg, 10-month-old male Kelpie developed a rapid onset of profound paresis progressing to flaccid paralysis and dyspnoea, followed by death about 36 hours after chewing on a partly discharged anti-bloat capsule from a dead cow. Intoxication by monensin in the capsule was considered the cause of death. No Lodes holocyclus were found on the dog. Evidence of muscle damage was seen in clinical biochemistry assays of plasma, but consent for necropsy was not obtained. The median lethal dose for Beagle dogs of the material contained in anti-bloat capsules is 0.5-1.0g. As this represents a serious toxicity risk if dogs chew these devises, the manufacturer includes a warning on potential dog toxicity in product literature.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Concussion severity grades according to the Cantu, Colorado Medical Society, and American Academy of Neurology systems were not clearly related to the presence or duration of impaired neuropsychological test performance in 21 professional rugby league athletes. The use of concussion severity guidelines and neuropsychological testing to assist return to play decisions requires further investigation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper tests the explanatory capacities of different versions of new institutionalism by examining the Australian case of a general transition in central banking practice and monetary politics: namely, the increased emphasis on low inflation and central bank independence. Standard versions of rational choice institutionalism largely dominate the literature on the politics of central banking, but this approach (here termed RC1) fails to account for Australian empirics. RC1 has a tendency to establish actor preferences exogenously to the analysis; actors' motives are also assumed a priori; actor's preferences are depicted in relatively static, ahistorical terms. And there is the tendency, even a methodological requirement, to assume relatively simple motives and preference sets among actors, in part because of the game theoretic nature of RC1 reasoning. It is possible to build a more accurate rational choice model by re-specifying and essentially updating the context, incentives and choice sets that have driven rational choice in this case. Enter RC2. However, this move subtly introduces methodological shifts and new theoretical challenges. By contrast, historical institutionalism uses an inductive methodology. Compared with deduction, it is arguably better able to deal with complexity and nuance. It also utilises a dynamic, historical approach, and specifies (dynamically) endogenous preference formation by interpretive actors. Historical institutionalism is also able to more easily incorporate a wider set of key explanatory variables and incorporate wider social aggregates. Hence, it is argued that historical institutionalism is the preferred explanatory theory and methodology in this case.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To determine which species and populations of Anopheles transmit malaria in any given situation, immunological assays for malaria sporozoite antigen can replace traditional microscopical examination of freshly dissected Anopheles. We developed a wicking assay for use with mosquitoes that identifies the presence or absence of specific peptide epitopes of circumsporozoite (CS) protein of Plasmodium falciparum and two strains of Plasmodium vivax (variants 210 and 247). The resulting assay (VecTest(TM) Malaria) is a rapid, one-step procedure using a 'dipstick' test strip capable of detecting and distinguishing between P. falciparum and P. vivax infections in mosquitoes. The objective of the present study was to test the efficacy, sensitivity, stability and field-user acceptability of this wicking dipstick assay. In collaboration with 16 test centres world-wide, we evaluated more than 40 000 units of this assay, comparing it to the standard CS ELISA. The 'VecTest(TM) Malaria' was found to show 92% sensitivity and 98.1% specificity, with 97.8% accuracy overall. In accelerated storage tests, the dipsticks remained stable for >15 weeks in dry conditions up to 45degreesC and in humid conditions up to 37degreesC. Evidently, this quick and easy dipstick test performs at an acceptable level of reliability and offers practical advantages for field workers needing to make rapid surveys of malaria vectors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A literature review has highlighted the need to measure flotation froth rheology in order to fully characterise the role of the froth in the flotation process. The initial investigation using a coaxial cylinder viscometer for froth rheology measurement led to the development of a new device employing a vane measuring head. The modified rheometer was used in industrial scale flotation tests at Mt. Isa Copper Concentrator. The measured froth rheograms show a non-Newtonian nature for the flotation froths (pseudoplastic flow). The evidence of the non-Newtonian flow has questioned the validity of application of the Laplace equation in froth motion modelling as used by a number of researchers, since the assumption of irrotational flow is violated. Correlations between the froth rheology and the froth retention time, water hold-up in the froth and concentrate grades have been found. These correlations are independent of air flow rate (test data at various air flow rates fall on one similar trend line). This implies that froth rheology may be used as a lumped parameter for other operating variables in flotation modelling and scale up. (C) 2003 Elsevier Science B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to quantify the sagittal angular displacement of the head (cranio-cervical flexion) for the five incremental stages of the cranio-cervical flexion test (CCFT). Range of cranio-cervical flexion during the CCFT was measured using a digital imaging method in 20 healthy volunteer subjects. The intra- and inter-rater reliability of the digital imaging technique for the assessment of this movement were also examined. The results of this study demonstrated a linear relationship between the incremental pressure targets of the CCFT and the percentages of full range cranio-cervical flexion range of motion (ROM) measured in the supine lying position of the test using a digital imaging technique. A mean of 22.9% full range cranio-cervical flexion was used to reach the first pressure target of the CCFT followed by linear increments up to 76.6% for the last stage of the test. An increasing amount of cranio-cervical flexion ROM was used to achieve the five successive stages of the CCFT reflecting an increasing contractile demand on the deep cervical flexor muscles. Excellent inter-rater (ICC = 0.994) and intra-rater reliability (ICC = 0.988-0.998) were demonstrated for the angular measurements using this digital imaging technique. (C) 2003 Elsevier Science Ltd. All rights reserved.