958 resultados para subset consistency


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Abstract In this paper, we address the problem of picking a subset of bids in a general combinatorial auction so as to maximize the overall profit using the first-price model. This winner determination problem assumes that a single bidding round is held to determine both the winners and prices to be paid. We introduce six variants of biased random-key genetic algorithms for this problem. Three of them use a novel initialization technique that makes use of solutions of intermediate linear programming relaxations of an exact mixed integer-linear programming model as initial chromosomes of the population. An experimental evaluation compares the effectiveness of the proposed algorithms with the standard mixed linear integer programming formulation, a specialized exact algorithm, and the best-performing heuristics proposed for this problem. The proposed algorithms are competitive and offer strong results, mainly for large-scale auctions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The morphological criteria for identification of intercalated duct lesions (IDLs) of salivary glands have been defined recently. It has been hypothesised that IDL could be a precursor of basal cell adenoma (BCA). BCAs show a variety of histological patterns, and the tubular variant is the one that presents the strongest resemblance with IDLs. The aim of this study was to analyse the morphological and immunohistochemical profiles of IDLs and BCAs classified into tubular and non-tubular subtypes, to determine whether or not IDL and tubular BCA represent distinct entities. Eight IDLs, nine tubular BCAs and 19 non-tubular BCAs were studied. All tubular BCAs contained IDL-like areas, which represented 20-70% of the tumour. In non-tubular BCA, IDL-like areas were occasional and small (<5%). One patient presented IDLs, tubular BCAs and IDL/tubular BCA combined lesions. Luminal ductal cells of IDLs and tubular BCAs exhibited positivity for CK7, lysozyme, S100 and DOG1. In the non-tubular BCA group, few luminal cells exhibited such an immunoprofile; they were mainly CK14-positive. Basal/myoepithelial cells of IDLs, tubular BCAs and non-tubular BCAs were positive for CK14, calponin, α-SMA and p63; they were more numerous in BCA lesions. IDL, tubular BCA and non-tubular BCA form a continuum of lesions in which IDLs are related closely to tubular BCA. In both, the immunoprofile of luminal and myoepithelial cells recapitulates the normal intercalated duct. The difference between the adenoma-like subset of IDLs and tubular BCA rests mainly on the larger numbers of myoepithelial cells in the latter. Our findings indicate that at least some BCAs can arise via IDLs.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Use of cisplatin can induce type I hypersensitivity reactions that may also be linked to the quality of the drug utilized. We observed cases of hypersensitivity that appeared to be associated with the brand of cisplatin used. The aim of this study was to compare two different brands of cisplatin in relation to type I hypersensitivity reactions. Brand A was used in a tertiary care teaching hospital until 2012, and use of brand B started from January 2013, when the first hypersensitivity cases were observed. Patients were categorized based on symptom. Cisplatin of both brands was analysed by high-performance liquid chromatography (HPLC) and high-resolution electrospray ionization mass spectrometry (ESI-(+)-MS) and characterized according to US Pharmacopeia. There were no cases of hypersensitivity associated with the use of cisplatin brand A, whereas four of 127 outpatients that used cisplatin brand B were affected. The two brands were in accordance with the US Pharmacopeia parameters, and there was no significant difference in the total platinum levels between the two brands when analysed by HPLC. However, high-resolution ESI-(+)-MS analyses show that brand B contains approximately 2.7 times more hydrolysed cisplatin than brand A. The increase in the hydrolysed form of cisplatin found in brand B may be the cause of the hypersensitivity reaction observed in a subset of patients. We present the first study of the quality of drugs by high-resolution ESI-(+)-MS. Drug regulatory agencies and manufacturers should consider including measurement of hydrolysed cisplatin as a quality criterion for cisplatin formulations.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dysphagia is relatively common in individuals with neurological disorders. To describe the swallowing management and investigate associated factors with swallowing in a case series of patients with Parkinson's disease. It is a long-term study with 24 patients. The patients were observed in a five-year period (2006-2011). They underwent Fiberoptic Endoscopic Evaluation of Swallowing, Functional Oral Intake Scale and therapeutic intervention every three months. In the therapeutic intervention they received orientation about exercises to improve swallowing. The Chi-square, Kruskal-Wallis and Fisher's tests were used. The period of time for improvement or worsening of swallowing was described by Kaplan-Meier analysis. During the follow-up, ten patients improved, five stayed the same and nine worsened their swallowing functionality. The median time for improvement was ten months. Prior to the worsening there was a median time of 33 months of follow-up. There was no associated factor with improvement or worsening of swallowing. The maneuvers frequently indicated in therapeutic intervention were: chin-tuck, bolus consistency, bolus effect, strengthening-tongue, multiple swallows and vocal exercises. The swallowing management was characterized by swallowing assessment every three months with indication of compensatory and rehabilitation maneuvers, aiming to maintain the oral feeding without risks. There was no associated factor with swallowing functionality in this case series.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The function of lipids in human nutrition has been intensively debated in the last decade.This context reinforces the concern about controlling the trans fat ingestion, due to its negative implications on health. Interesterification provides an important alternative to modify the consistency of oils and fats without causing formation of trans isomers. This article reports research done towards production of zero trans fats by chemical interesterification, for different industrial purposes. Aspects related to the effect of trans fats on diet, their impact on health and modifications in Brazilian legislation are also covered.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The objective of this study was to quantify the effect of plonk on compressive behavior and mechanical attributes such as consistency, optimum moisture for compaction and maximum density of a Red-Yellow Latosol (Oxisol) to evaluate the effect of plonk and compaction state in splashed particles, from Lavras (MG) region. The plonk was obtained from an artisanal sugarcane brandy alembic. Undisturbed and disturbed soil samples were collected at 0 to 3 cm and 60 to 63 cm depths. Disturbed soil samples were used for soil characterization, determination of consistence limits and Normal Proctor essay after material incubation with plonk. Undisturbed soil samples were saturated with plonk or distilled water (control) during 48 hours for testing the compressibility and resistance to splash by using simulated rainfall. The plonk altered the consistence limits of studied layers. For the 0-3 cm layer, the plonk reduced the friable range, and for the 60-63 cm layer the effect was in the opposite direction. For both layers, the plonk increased Dmax and decreased Uoptimum. Regardless of the plonk treatment, both layers presented the same load support capacity. The compaction degree of samples influenced the splash erosion. The increase of the applied pressure over the samples resulted in increase of splash material quantity. At the 60-63 cm layer, the plonk treatment reduced the splash material quantity by increasing the applied pressure, mainly when the samples were at field capacity.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To compare intraocular pressure (IOP) rise in normal individuals and primary open-angle glaucoma patients and the safety and efficacy of ibopamine eye drops in different concentrations as a provocative test for glaucoma. METHODS: Glaucoma patients underwent (same eye) the ibopamine provocative test with two concentrations, 1% and 2%, in a random sequence at least 3 weeks apart, but not more than 3 months. The normal individuals were randomly submitted to one of the concentrations of ibopamine (1% and 2%). The test was considered positive if there was an IOP rise greater than 3 or 4 mmHg at 30 or 45 minutes to test which subset of the test has the best sensitivity (Se)/specificity (Sp). RESULTS: There was no statistically significant difference in any of the IOP measurements, comparing 1% with 2% ibopamine. The IOP was significantly higher at 30 and 45 minutes with both concentrations (p<0.001). The best sensitivity/specificity ratio was achieved with the cutoff point set as greater than 3 mmHg at 45 minutes with 2% ibopamine (area under the ROC curve: 0.864, Se: 84.6%; Sp:73.3%). All patients described a slight burning after ibopamine's instillation. CONCLUSION: 2% ibopamine is recommended as a provocative test for glaucoma. Because both concentrations have similar ability to rise IOP, 1% ibopamine may be used to treat ocular hypotony.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Universidade Estadual de Campinas . Faculdade de Educação Física

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Universidade Estadual de Campinas . Faculdade de Educação Física

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Universidade Estadual de Campinas. Faculdade de Educação Física

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Universidade Estadual de Campinas . Faculdade de Educação Física

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Universidade Estadual de Campinas . Faculdade de Educação Física

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Noncarious cervical lesions (NCCLs) are considered to be of multifactorial origin, normally associated with inadequate brushing. This study assessed the influence in vitro of simulated brushing on NCCL formation. Fifteen human premolars were submitted to brushing in the cementoenamel junction region, using hard-, medium- and soft-bristled brushes associated with a toothpaste of medium abrasiveness under a 200 g load, at a speed of 356 rpm for 100 minutes. The surface topography of the region was analyzed before and after brushing, by means of a laser interferometer, using "cut-off" values of 0.25 and considering roughness values in mm. The initial roughness (mm) results for dentin (D / bristle consistency: 1 - soft, 2 - medium and 3 - hard) were as follows: (D1) 1.25 ± 0.45; (D2) 1.12 ± 0.44; (D3) 1.05 ± 0.41. For enamel (E / bristle consistency: 1 - soft, 2 - medium and 3 - hard), the initial results were: (E1) 1.18 ± 0.35; (E2) 1.32 ± 0.25; (E3) 1.50 ± 0.38. After brushing, the following were the values for dentin: (D1) 2.32 ± 1.99; (D2) 3.30 ± 0.96; (D3) Over 500. For enamel, the values after brushing were: (E1) 1.37 ± 0.31; (E2) 2.15 ± 0.90; (E3) 1.22 ± 0.47. Based on the results of the ANOVA and Tukey statistical analyses (a = .05) it was concluded that soft, medium and hard brushes are not capable of abrading enamel, whereas dentin showed changes in surface roughness by the action of medium- and hard-bristled brushes.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Este estudo teve como objetivo realizar a adaptação cultural do The Environmental Stressor Questionnaire - (ESQ) para a língua portuguesa do Brasil e verificar sua confiabilidade e validade. Foram empregadas as etapas metodológicas recomendadas pela literatura para adaptação cultural. A versão brasileira do ESQ foi aplicada a 106 pacientes de Unidade de Terapia Intensiva (UTI) de dois hospitais, público e privado, do interior do Estado de São Paulo. A confiabilidade foi avaliada quanto à consistência interna e estabilidade (teste e reteste); a validade convergente foi verificada por meio da correlação entre o ESQ e questão genérica sobre estresse em UTI. A confiabilidade foi satisfatória com Alfa de Crombach=0,94 e Coeficiente de Correlação Intraclasse=0,861 (IC95% 0,723; 0,933). Constatou-se correlação entre o escore total do ESQ e a questão genérica sobre estresse (r=0,70), confirmando a validade convergente. A versão brasileira do ESQ mostrou-se uma ferramenta confiável e válida para avaliação de estressores em UTI.