965 resultados para rapid slide agglutination test


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Polybrominated diphenyl ethers (PBDEs) are a class of brominated flame retardants (BFRs) once extensively used in the plastics of a wide range of consumer products. The listing of certain congeners that are constituents of commercial PBDE mixtures (including c-octaBDE) in the Stockholm Convention and tightening regulation of many other BFRs in recent years have created the need for a rapid and effective method of identifying BFR-containing plastics. A three-tiered testing strategy comparing results from non-destructive testing (X-ray fluorescence (XRF)) (n = 1714), a surface wipe test (n = 137) and destructive chemical analysis (n = 48) was undertaken to systematically identify BFRs in a wide range of consumer products. XRF rapidly identified bromine in 92% of products later confirmed to contain BFRs. Surface wipes of products identified tetrabromobisphenol A (TBBPA), c-octaBDE congeners and BDE-209 with relatively high accuracy (> 75%) when confirmed by destructive chemical analysis. A relationship between the amounts of BFRs detected in surface wipes and subsequent destructive testing shows promise in predicting not only the types of BFRs present but also estimating the concentrations present. Information about the types of products that may contain persistent BFRs will assist regulators in implementing policies to further reduce the occurrence of these chemicals in consumer products.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

his paper describes an improved microtiter solid-phase enzyme immunoassay for the determination of total and allergen-specific human IgE. This assay technique is unique in its use of the avidin-biotin interaction to increase sensitivity. The avidin-biotin microtiter enzyme-linked immunosorbant assay (AB-microELISA) was performed in polyvinyl chloride microtiter plates using biotinylated anti-IgE and horseradish peroxidase (HRP)-avidin conjugate. This AB-microELISA technique enabled the quantitation of human serum IgE in the range of 0.1–5 ng/ml (10–500 pg/test) in less than 3 h. Total serum IgE, whether measured by the AB-microELISA or the paper radioimmunosorbant test (PRIST) was similar (correlation coefficient, r = 0.92). Further, the presence or absence of positive skin tests to 7 specific allergens determined in serum donors generally agreed with the presence or absence of allergen-specific IgE in their sera as measured by the AB-microELISA. The quantity of short ragweed allergen-specific IgE as determined by the AB-microELISA agreed with values obtained by the radioimmunosorbant test (RAST) (correlation coefficient, r = 0.89). No significant interference by ragweed-specific IgG (blocking antibody) was observed in the quantitation of allergen-specific IgE. The AB-microELISA is not only rapid and inexpensive, but also more sensitive than other published ELISA procedures and comparable to solid-phase radioimmunoassays in the quantitation of total and allergen-specific IgE.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Volatile chemical compounds responsible for the aroma of wine are derived from a number of different biochemical and chemical pathways. These chemical compounds are formed during grape berry metabolism, crushing of the berries, fermentation processes (i.e. yeast and malolactic bacteria) and also from the ageing and storage of wine. Not surprisingly, there are a large number of chemical classes of compounds found in wine which are present at varying concentrations (ng L-1 to mg L-1), exhibit differing potencies, and have a broad range of volatilities and boiling points. The aim of this work was to investigate the potential use of near infrared (NIR) spectroscopy combined with chemometrics as a rapid and low-cost technique to measure volatile compounds in Riesling wines. Samples of commercial Riesling wine were analyzed using an NIR instrument and volatile compounds by gas chromatography (GC) coupled with selected ion monitoring mass spectrometry. Correlation between the NIR and GC data were developed using partial least-squares (PLS) regression with full cross validation (leave one out). Coefficients of determination in cross validation (R 2) and the standard error in cross validation (SECV) were 0.74 (SECV: 313.6 μg L−1) for esters, 0.90 (SECV: 20.9 μg L−1) for monoterpenes and 0.80 (SECV: 1658 ?g L-1) for short-chain fatty acids. This study has shown that volatile chemical compounds present in wine can be measured by NIR spectroscopy. Further development with larger data sets will be required to test the predictive ability of the NIR calibration models developed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

To test the robustness and validity of our prototype LPS-specific multiplex PCR on P. multocida field isolates and develop the PCR into a diagnostic test capable of accurately and reliably typing P. multocida strains.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Nitrogen (N) is an essential nutrient in mango, influencing both productivity and fruit quality. In Australian mango orchards, tree N is traditionally assessed once a year at the dormant pre-flowering stage using laboratory analysis of leaf N. This single assessment is insufficient to determine tree N status at all stages of the annual phenological cycle. Development of a field-based rapid N test would allow more frequent monitoring of tree N status and improved fertiliser management. These experiments examined the accuracy and useability of several devices used in other horticultural crops to rapidly assess mango leaf N in the field; the Konica Minolta 'SPAD-502 chlorophyll meter', Horiba 'Cardy Meter' and the Merck 'RQflex 10.' Regression and correlation analyses were used to determine the relationship between total leaf N and the measurements from the rapid test devices. The relationship between the chlorophyll index measured by the SPAD-502 meter and leaf N was highly significant at late fruit set (R 2=0.72, n=40) and post-harvest (R 2=0.81, n=40) stages and significant at the flowering stage (R 2=0.51, n=40) in the cultivar 'Kensington Pride', indicating the device can be used to rapidly assess mango leaf N in the field. Correlation analysis indicated the relationship between petiole sap measured with the Cardy or Merck devices and leaf N was non-significant.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Pasteurella multocida is a Gram-negative bacterial pathogen that is the causative agent of a wide range of diseases in many animal species, including humans. A widely used method for differentiation of P. multocida strains involves the Heddleston serotyping scheme. This scheme was developed in the early 1970s and classifies P. multocida strains into 16 somatic or lipopolysaccharide (LPS) serovars using an agar gel diffusion precipitin test. However, this gel diffusion assay is problematic, with difficulties reported in accuracy, reproducibility, and the sourcing of quality serovar-specific antisera. Using our knowledge of the genetics of LPS biosynthesis in P. multocida, we have developed a multiplex PCR (mPCR) that is able to differentiate strains based on the genetic organization of the LPS outer core biosynthesis loci. The accuracy of the LPS-mPCR was compared with classical Heddleston serotyping using LPS compositional data as the "gold standard." The LPS-mPCR correctly typed 57 of 58 isolates; Heddleston serotyping was able to correctly and unambiguously type only 20 of the 58 isolates. We conclude that our LPS-mPCR is a highly accurate LPS genotyping method that should replace the Heddleston serotyping scheme for the classification of P. multocida strains.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Testing for mutagenicity and carcinogenicity has become an integral part of the toxicological evaluation of drugs and chemicals. Standard carcinogenicity tests in vivo require both large numbers of animals and prolonged experiments. To circumvent these problems, several rapid tests have been developed for preliminary screening of mutagens and carcinogens in vitro. Ames and his associates, the first to develop a mutation test, used mutant strains of Salmonella typhimurium [1]. Mutation tests with Escherichia coli, Bacillus subtilis, Neurospora crassa and Saccharomyces cerevisiae, and DNA-repair tests with E. coli and B. subtilis, have been developed. Cytogenetic assays, in vivo as well as in vitro, in both plant and animal systems, are also used to detect potential mutagens and carcinogens. Transfection is inhibited by base mutation, cleavage of DNA, loss of cohesive ends, interaction with histones, spermidine, nalidixic acid, etc. [3]. The efficiency of transfection is affected by temperature, DNA structure and the condition of the competence of the recipient cells [3]. Transfection assays with phages MS: RNA and ~i, x 174-DNA have been reported [15]. A fast and easy transfection assay using colitis bacteriophage DNA is reported in this communication.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A sensitive and rapid bioassay of inhibin is described. Swiss albino female mice, 27 days old, weighing 25-30 g, were primed with 20 IU hCG, given in 2 equal doses, administered at 0900 h and 1800 h. An increment of 200% in uterine weight could be observed when the animals were autopsied the next day at 1000 h. The validity of the endpoint chosen, as a function dependent on FSH, was shown by the fact that neutralization of endogenous FSH by FSH antiserum led to an inhibition of uterine weight increase. Further injection of the inhibin material caused an actual reduction in the heightened levels of FSH (ng/ml) brought about by hCG: Control, 207 ± 13.6; hCG, 365 ± 28.8 and hCG inhibin, below the detection level of radioimmunoassay. Inhibin preparation from ovine testicular extract when tested at 3 dose levels showed a dose dependent and significant suppression in uterine weight increase. The assay was statistically validε = 2.5; slope = 23.9; λ = 0.104 and intra- and interassay variation = 8.3% and 11.7%, respectively. Since the mouse uterine weight assay is specific, has greater sensitivity and is uniformly reproducible, it is suggested that this assay procedure is ideally suited to assess the activity of different inhibin test preparations as well as to follow the purification of inhibin activity from crude material.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Allergens from the pollen of Parthenium hysterophorus (American feverfew), responsible for high incidence of allergic rhinitis, were found by immunoprint analysis to be localized on the surface of the pollen grains. The allergens were released very rapidly when extracted in vitro. The allergenic activity of the rapid (10 s) and slowly (20 h) released pollen proteins was comparable by in vivo skin test and ELISA inhibition assay. The isoelectric focusing patterns of the rapid and slowly released proteins, were also identical. SDS-PAGE and Western blot analysis revealed that all the major pollen allergens with molecular weight 14, 28, 31, 37 and 45 kDa were eluted within 10 s of extraction. Periodate-Schiff staining showed that the 28, 31 and 45 kDa components of the pollen extract are glycoproteins. The pollen allergens released after different periods of extraction lost 75% of IgE binding activity when subjected to in situ sodium m-periodate oxidation under controlled conditions, while 80% of the allergenic activity was still retained after extensive proteolysis. Our results support the clinical observation of a rapid onset of symptoms of allergic rhinitis in patients sensitive to Parthenium pollen, mediated predominantly by glycoproteins.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The determination of consolidation characteristics forms an important aspect in the design of foundations and other earth-retaining structures. The conventional consolidation test as originally proposed by Teaaghi takes considerable time (more than 15 days in highly compressible soils with low coefficient of consolidation) and effort. Any effort to reduce the duration of testing will be desirable from several considerations. In this paper, an attempt has been made to propose a rapid method of consolidation testing. In the proposed method, the next load increment is applied as soon as the necessary time required to identify the percent consolidation is reached and to evaluate the coefficient of consolidation by one of the popular curve-fitting procedures. The rectangular hyperbola method has been used to identify the percent consolidation reached after any load increment, and to determine the coefficient of consolidation, before making the next load increment. The time required to complete the test using the rapid consolidation method could be as low as 4-5 h compared with 1 or 2 weeks in the case of the conventional consolidation test.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A rapid and cost effective DNA test is described to identify European eel (Anguilla anguilla) and North American eel (Anguilla rostrata). By means of polymerase chain reaction (PCR) technique parts of the mitochondrial cytochrome b gene are amplified with species specific primers which are designed to produce PCR fragments of different characteristic sizes for European and American eel. The size differences can easily be made visible by agarose gel electrophoresis

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Poor outcomes of invasive candidiasis (IC) are associated with the difficulty in establishing the microbiological diagnosis at an early stage. New scores and laboratory tests have been developed in order to make an early therapeutic intervention in an attempt to reduce the high mortality associated with invasive fungal infections. Candida albicans IFA IgG has been recently commercialized for germ tube antibody detection (CAGTA). This test provides a rapid and simple diagnosis of IC (84.4% sensitivity and 94.7% specificity). The aim of this study is to identify the patients who could be benefited by the use of CAGTA test in critical care setting. Methods: A prospective, cohort, observational multicentre study was carried out in six medical/surgical Intensive care units (ICU) of tertiary-care Spanish hospitals. Candida albicans Germ Tube Antibody test was performed twice a week if predetermined risk factors were present, and serologically demonstrated candidiasis was considered if the testing serum dilution was >= 1: 160 in at least one sample and no other microbiological evidence of invasive candidiasis was found. Results: Fifty-three critically ill non-neutropenic patients (37.7% post surgery) were included. Twenty-two patients (41.5%) had CAGTA-positive results, none of them with positive blood culture for Candida. Neither corrected colonization index nor antifungal treatment had influence on CAGTA results. This finding could corroborate that the CAGTA may be an important biomarker to distinguish between colonization and infection in these patients. The presence of acute renal failure at the beginning of the study was more frequent in CAGTA-negative patients. Previous surgery was statistically more frequent in CAGTA-positive patients. Conclusions: This study identified previous surgery as the principal clinical factor associated with CAGTA-positive results and emphasises the utility of this promising technique, which was not influenced by high Candida colonization or antifungal treatment. Our results suggest that detection of CAGTA may be important for the diagnosis of invasive candidiasis in surgical patients admitted in ICU.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The content of free formaldehyde (FA) in minced fish muscle was measured by the following procedure: A mixture of minced fish muscle and water was deproteinized by means of the Carrez reagent. The FA content of the filtrate was determined reflectometrically using the Reflectoquant test strips and the RQflex. The results agreed well with the colorimetrically (Nash test) measured FA content. Der Gehalt an freiem Formaldehyd (FA)in Fischerzeugnissen wurde mit folgender Methode bestimmt: Zerkleinertes Fischfleisch wurde mit Wasser homogenisiert und mit Carrez-Reagenz enteiweißt. Der Formaldehydgehalt des Filtrates wurde reflektometrisch unter Verwendung von Reflectoquant-Teststätbchen und des RQflex ermittelt. Die Ergebnisse stimmten gut mit kolorimetrisch (Nash Test) gemessenen FA-Gehalten überein.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Chapter I

Theories for organic donor-acceptor (DA) complexes in solution and in the solid state are reviewed, and compared with the available experimental data. As shown by McConnell et al. (Proc. Natl. Acad. Sci. U.S., 53, 46-50 (1965)), the DA crystals fall into two classes, the holoionic class with a fully or almost fully ionic ground state, and the nonionic class with little or no ionic character. If the total lattice binding energy 2ε1 (per DA pair) gained in ionizing a DA lattice exceeds the cost 2εo of ionizing each DA pair, ε1 + εo less than 0, then the lattice is holoionic. The charge-transfer (CT) band in crystals and in solution can be explained, following Mulliken, by a second-order mixing of states, or by any theory that makes the CT transition strongly allowed, and yet due to a small change in the ground state of the non-interacting components D and A (or D+ and A-). The magnetic properties of the DA crystals are discussed.

Chapter II

A computer program, EWALD, was written to calculate by the Ewald fast-convergence method the crystal Coulomb binding energy EC due to classical monopole-monopole interactions for crystals of any symmetry. The precision of EC values obtained is high: the uncertainties, estimated by the effect on EC of changing the Ewald convergence parameter η, ranged from ± 0.00002 eV to ± 0.01 eV in the worst case. The charge distribution for organic ions was idealized as fractional point charges localized at the crystallographic atomic positions: these charges were chosen from available theoretical and experimental estimates. The uncertainty in EC due to different charge distribution models is typically ± 0.1 eV (± 3%): thus, even the simple Hückel model can give decent results.

EC for Wurster's Blue Perchl orate is -4.1 eV/molecule: the crystal is stable under the binding provided by direct Coulomb interactions. EC for N-Methylphenazinium Tetracyanoquino- dimethanide is 0.1 eV: exchange Coulomb interactions, which cannot be estimated classically, must provide the necessary binding.

EWALD was also used to test the McConnell classification of DA crystals. For the holoionic (1:1)-(N,N,N',N'-Tetramethyl-para- phenylenediamine: 7,7,8,8-Tetracyanoquinodimethan) EC = -4.0 eV while 2εo = 4.65 eV: clearly, exchange forces must provide the balance. For the holoionic (1:1)-(N,N,N',N'-Tetramethyl-para- phenylenediamine:para-Chloranil) EC = -4.4 eV, while 2εo = 5.0 eV: again EC falls short of 2ε1. As a Gedankenexperiment, two nonionic crystals were assumed to be ionized: for (1:1)-(Hexamethyl- benzene:para-Chloranil) EC = -4.5 eV, 2εo = 6.6 eV; for (1:1)- (Napthalene:Tetracyanoethylene) EC = -4.3 eV, 2εo = 6.5 eV. Thus, exchange energies in these nonionic crystals must not exceed 1 eV.

Chapter III

A rapid-convergence quantum-mechanical formalism is derived to calculate the electronic energy of an arbitrary molecular (or molecular-ion) crystal: this provides estimates of crystal binding energies which include the exchange Coulomb inter- actions. Previously obtained LCAO-MO wavefunctions for the isolated molecule(s) ("unit cell spin-orbitals") provide the starting-point. Bloch's theorem is used to construct "crystal spin-orbitals". Overlap between the unit cell orbitals localized in different unit cells is neglected, or is eliminated by Löwdin orthogonalization. Then simple formulas for the total kinetic energy Q^(XT)_λ, nuclear attraction [λ/λ]XT, direct Coulomb [λλ/λ'λ']XT and exchange Coulomb [λλ'/λ'λ]XT integrals are obtained, and direct-space brute-force expansions in atomic wavefunctions are given. Fourier series are obtained for [λ/λ]XT, [λλ/λ'λ']XT, and [λλ/λ'λ]XT with the help of the convolution theorem; the Fourier coefficients require the evaluation of Silverstone's two-center Fourier transform integrals. If the short-range interactions are calculated by brute-force integrations in direct space, and the long-range effects are summed in Fourier space, then rapid convergence is possible for [λ/λ]XT, [λλ/λ'λ']XT and [λλ'/λ'λ]XT. This is achieved, as in the Ewald method, by modifying each atomic wavefunction by a "Gaussian convergence acceleration factor", and evaluating separately in direct and in Fourier space appropriate portions of [λ/λ]XT, etc., where some of the portions contain the Gaussian factor.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Up-converting phosphor technology (UPT)-based lateral-flow immunoassay has been developed for quantitative detection of Yersinia pestis rapidly and specifically. In this assay, 400 nm up-converting phosphor particles were used as the reporter. A sandwich immumoassay was employed by using a polyclonal antibody against F1 antigen of Y. pestis immobilized on the nitrocellulose membrane and the same antibody conjugated to the UPT particles. The signal detection of the strips was performed by the UPT-based biosensor that could provide a 980 nm IR laser to excite the phosphor particles, then collect the visible luminescence emitted by the UPT particles and finally convert it to the voltage as a signal. V-T and V-c stand for the multiplied voltage units for the test and the control line, respectively, and the ratio V-T/V-C is directly proportional to the number of Y pestis in a sample. We observed a good linearity between the ratio and log CFU/ml of Y pestis above the detection limit, which was approximately 10(4) CFU/mI. The precision of the intra- and inter-assay was below 15% (coefficient of variation, CV). Cross-reactivity with related Gram-negative enteric bacteria was not found. The UPT-LF immunoassay system presented here takes less than 30 min to perform from the sample treatment to the data analysis. The current paper includes only preliminary data concerning the biomedical aspects of the assay, but is more concentrated on the technical details of establishing a rapid manual assay using a state-of-the-art label chemistry. (c) 2006 Elsevier B.V. All rights reserved.