947 resultados para quantization artifacts


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Team Archaeology is excited to be riding with you this year! We hope to make our participation an annual opportunity to share the story of Iowa’s amazing past. As you ride across the state you will be passing by the locations of hundreds of known archaeological sites and an as yet unknown number of new discoveries waiting to be made. These archaeological sites, and the artifacts they contain, tell the history of the first people to travel this landscape and the stories of each generation that has contributed to what we know of ourselves today. As you travel through our beautiful state, you too are now a part of that story, making history for the future to learn and wonder about! The Office of the State Archaeologist serves a unique dual role in Iowa as both a designated research unit of The University of Iowa and as a state agency. The larger mission of the OSA is to develop, disseminate, and preserve knowledge of Iowa’s human past through Midwestern and Plains archaeological research, scientific discovery, public stewardship, service, and education. It is our goal to provide all Iowans the opportunity to learn about their past. I see this as an investment in the preservation of a nonrenewable resource—the archaeological record of Iowa. Look for the Team Archeology members as you ride and be sure to ask them about Iowa archeology. Please help yourself to free materials about our shared past from our information tables at each overnight town and get one of the free Iowa Archeology wrist bands. There will also be free public talks by local archaeologists each afternoon, as well as flintknapping and other demonstrations of archaeological interest, so keep this booklet as your guide to the week’s activities. Most of all, ride smart, be safe, and when you get home tell your friends and neighbors about Iowa archaeology!

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this work we present a first feasibility study of the ClearPEM technology for simultaneous PET-MR imaging. The mutual electromagnetic interference (EMI) effects between both systems were evaluated on a 7 T magnet by characterizing the response behavior of the ClearPEM detectors and front-end electronics to pulsed RF power and switched magnetic field gradients; and by analyzing the MR system performance degradation from noise pickup into the RF receiver chain, and from magnetic susceptibility artifacts caused by PET front-end materials.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We consider adaptive sequential lossy coding of bounded individual sequences when the performance is measured by the sequentially accumulated mean squared distortion. Theencoder and the decoder are connected via a noiseless channel of capacity $R$ and both are assumed to have zero delay. No probabilistic assumptions are made on how the sequence to be encoded is generated. For any bounded sequence of length $n$, the distortion redundancy is defined as the normalized cumulative distortion of the sequential scheme minus the normalized cumulative distortion of the best scalarquantizer of rate $R$ which is matched to this particular sequence. We demonstrate the existence of a zero-delay sequential scheme which uses common randomization in the encoder and the decoder such that the normalized maximum distortion redundancy converges to zero at a rate $n^{-1/5}\log n$ as the length of the encoded sequence $n$ increases without bound.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: Recent work practices in the conservation and restoration involve the use of cyclododecane (CDD, CAS 294-62-2) to protect fragile artifacts during their handling or transportation. Little is known about its toxicity, and no previous exposure has been reported. A short field investigation was conducted to characterize the exposure conditions to both CDD vapors and aerosols.METHODS: Measurements were conducted in the laboratory of conservation and restoration of the archeological service in Bern (Switzerland). Three indoor and four outdoor typical work situations, either during brush or spray gun applications, were investigated. Measurements were performed on charcoal adsorbent tube and analyzed by a gas chromatograph equipped with a flame ionization detector.RESULTS: Measurements have been conducted during both brush and spray gun applications. Indoor exposures were of 0.75-15.5 mg/m(3), while outdoors exposures were 19.5-53.9 mg/m(3). Exposures appear to be extremely localized due to both physicochemical properties and application methods of the CDD. Vapor exposure increases dramatically with the confinement of the workplace.CONCLUSION: Preventive measures should be undertaken to limit as much as possible these exposures. Field work in confined areas (ditches, underground) is of particular concern. CDD-coated artifacts or materials should be stored in ventilated areas to avoid delayed exposures. [Authors]

Relevância:

10.00% 10.00%

Publicador:

Resumo:

At 3 T, the effective wavelength of the RF field is comparable to the dimension of the human body, resulting in B1 standing wave effects and extra variations in phase. This effect is accompanied by an increase in B0 field inhomogeneity compared to 1.5 T. This combination results in nonuniform magnetization preparation by the composite MLEV weighted T2 preparation (T2 Prep) sequence used for coronary magnetic resonance angiography (MRA). A new adiabatic refocusing T2 Prep sequence is presented in which the magnetization is tipped into the transverse plane with a hard RF pulse and refocused using a pair of adiabatic fast-passage RF pulses. The isochromats are subsequently returned to the longitudinal axis using a hard RF pulse. Numerical simulations predict an excellent suppression of artifacts originating from B1 inhomogeneity while achieving good contrast enhancement between coronary arteries and surrounding tissue. This was confirmed by an in vivo study, in which coronary MR angiograms were obtained without a T2 Prep, with an MLEV weighted T2 Prep and the proposed adiabatic T2 Prep. Improved quantitative and qualitative coronary MRA image measurement was achieved using the adiabatic T2 Prep at 3 T.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The objective of this study was to evaluate the prenatal detection of chromosomal abnormalities by fetal ultrasonographic examination in a large database provided by 19 Registries of Congenital Anomalies from 11 European countries. This study included 1738 cases of chromosomal abnormalities, liveborn, stillborn or termination of pregnancy regardless of maternal age from a population of 664,340 births during the period 1996 - 1998. The most frequent chromosomal anomalies were Down syndrome (n=1050), trisomy 18 (n=191), Turner syndrome (n=125), trisomy 13 (n=86), and triploidy (n=56). Fetal ultrasonographic examination resulted in the prenatal detection of 37.7% of the chromosomal abnormalities, thereby resulting in a reduction of 28.6% in their prevalence at birth due to terminations of pregnancy. The detection rate by ultrasound examination varied according to local policies of prenatal diagnosis : it was lower in countries where routine scan were not performed and higher in countries in which at least one routine anomaly scan during the second trimester of pregnancy was performed. The ultrasound detection varied according to the specific chromosomal anomaly and was lowest for Klinefelter syndrome (5.7%) and highest for triploidy (78.6%). For Down syndrome it was 26.4%. Termination of pregnancy was performed in 75.9% of the cases. Among the 655 cases detected by ultrasound, the most frequent ultrasound signs by category of chromosomal abnormalities were analysed. This study shows that ultrasound screening is an important tool in the prenatal detection of chromosomal abnormalities in Europe, leading to a significant reduction in the prevalence of livebirth children with chromosomal anomalies.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Among numerous magnetic resonance imaging (MRI) techniques, perfusion MRI provides insight into the passage of blood through the brain's vascular network non-invasively. Studying disease models and transgenic mice would intrinsically help understanding the underlying brain functions, cerebrovascular disease and brain disorders. This study evaluates the feasibility of performing continuous arterial spin labeling (CASL) on all cranial arteries for mapping murine cerebral blood flow at 9.4 T. We showed that with an active-detuned two-coil system, a labeling efficiency of 0.82 ± 0.03 was achieved with minimal magnetization transfer residuals in brain. The resulting cerebral blood flow of healthy mouse was 99 ± 26 mL/100g/min, in excellent agreement with other techniques. In conclusion, high magnetic fields deliver high sensitivity and allowing not only CASL but also other MR techniques, i.e. (1)H MRS and diffusion MRI etc, in studying murine brains.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Coronary in-stent restenosis cannot be directly assessed by magnetic resonance angiography (MRA) because of the local signal void of currently used stainless steel stents. The aim of this study was to investigate the potential of a new, dedicated, coronary MR imaging (MRI) stent for artifact-free, coronary MRA and in-stent lumen and vessel wall visualization. METHODS AND RESULTS: Fifteen prototype stents were deployed in coronary arteries of 15 healthy swine and investigated with a double-oblique, navigator-gated, free-breathing, T2-prepared, 3D cartesian gradient-echo sequence; a T2-prepared, 3D spiral gradient-echo sequence; and a T2-prepared, 3D steady-state, free-precession coronary MRA sequence. Furthermore, black-blood vessel wall imaging by a dual-inversion-recovery, turbo spin-echo sequence was performed. Artifacts of the stented vessel segment and signal intensities of the coronary vessel lumen inside and outside the stent were assessed. With all investigated sequences, the vessel lumen and wall could be visualized without artifacts, including the stented vessel segment. No signal intensity alterations inside the stent when compared with the vessel lumen outside the stent were found. CONCLUSIONS: The new, coronary MRI stent allows for completely artifact-free coronary MRA and vessel wall imaging.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In studying and forming an understanding of Iowa’s transportation history, we must surely develop a reverence for the lifestyles which preceded ours. Achieving a greater understanding of our past, we are better prepared to plan our future as we say farewell to the 20th century and move forward into the 21st. In the words of Oliver Wendell Holmes: “I believe the greatest thing in this world is not so much where we stand as in what direction we are moving... and the further backward you can look, the farther forward you can see.” To help Iowans gain a better understanding of our state’s rich transportation past, the Iowa Department of Transportation has produced a collection of materials including this booklet, the 1999-2000 Iowa Transportation Map, a video entitled A History of Iowa’s Rivers, Roads, Rails and Runways, and a traveling photo exhibit. In addition, Iowa is fortunate to have many local organizations, and the state-owned museum and historic sites, working to preserve the history of our state. Listed in the back section of this booklet are the addresses and descriptions of many sites that offer visitors an opportunity to see a wide range of transportation- related artifacts. The information and photographs are organized in time sequence. However, you will note that many of the transportation eras overlap. The booklet begins with Iowa’s pre-settlement era and concludes with the historic highway and transit program that was signed into law by President Clinton in 1998. As you can imagine, condensing this much Iowa history into a booklet-sized resource was a monumental challenge. Making selections and abbreviating the information resulted in some difficult editorial choices. However, we hope this publication will inspire readers to learn more about our rich, rewarding past and to visit and experience some of Iowa’s historic sites.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

ABSTRACTPostmortem injuries are a source of misinterpretations in forensic analysis and therefore are subject matter of taphonomic interest. Many types of injuries can cause different artifacts, which deserve attention of the forensic pathologists when evaluating corpses, either at the crime scene or during an autopsy. Insects can be important biotaphonomic agents and their activity may result in artifacts that resemble antemortem injuries. Here, we describe postmortem injuries caused by the Neotropical wasp Agelaia fulvofasciata (Degeer, 1773) on domestic pig carcasses weighting 15 kg. The specimens showed extensive injuries to the lower lip, similar to lacerations, and some minor lesions on the snout and anus. In addition, we observed the same wasp species preying on larvae of Sarcophagidae (Peckia sp.). Besides causing postmortem injuries, the ability of this species to detect carcasses in the early and fresh decomposition stages should be noted. Thus, future applications aiming criminal, any biotaphonomic events caused by carrion insects need to be disclosed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Multidetector computed tomography is becoming more widespread in forensic medicine. In most services, autopsy assistants perform the radiological examination. We introduced professional radiographers into the legal medicine service and hypothesized they would also be able to take over duties currently reserved for other specialists. The aims of this study were to evaluate if radiographers could be trained as "forensic radiographers" by (1) integrating graduated medical radiographers into the legal medicine service, (2) investigating the advantages of this collaboration, and (3) defining the duties of the forensic radiographers.The study was performed prospectively on a group of 8 recruited radiographers who underwent a testing period with special training. They learned the basics of medicolegal case treatment, the autonomous execution of postmortem computed tomography angiography, and postprocessing of data. Seven of 8 radiographers finished the training and were integrated into our service. Although all radiographers were able to fulfill the duties demanded after the training period, some radiographers could not enter or complete the program because they were unable to work with dead bodies.Our study presents the advantages of integrating radiographers into the medicolegal team and proposes how to train the forensic radiographers. In addition, the duties and responsibilities of these new specialists are defined.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper presents a differential synthetic apertureradar (SAR) interferometry (DIFSAR) approach for investigatingdeformation phenomena on full-resolution DIFSAR interferograms.In particular, our algorithm extends the capabilityof the small-baseline subset (SBAS) technique that relies onsmall-baseline DIFSAR interferograms only and is mainly focusedon investigating large-scale deformations with spatial resolutionsof about 100 100 m. The proposed technique is implemented byusing two different sets of data generated at low (multilook data)and full (single-look data) spatial resolution, respectively. Theformer is used to identify and estimate, via the conventional SBAStechnique, large spatial scale deformation patterns, topographicerrors in the available digital elevation model, and possibleatmospheric phase artifacts; the latter allows us to detect, onthe full-resolution residual phase components, structures highlycoherent over time (buildings, rocks, lava, structures, etc.), as wellas their height and displacements. In particular, the estimation ofthe temporal evolution of these local deformations is easily implementedby applying the singular value decomposition technique.The proposed algorithm has been tested with data acquired by theEuropean Remote Sensing satellites relative to the Campania area(Italy) and validated by using geodetic measurements.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Three-dimensional (3D) navigator-gated and prospectively corrected free-breathing coronary magnetic resonance angiography (MRA) allows for submillimeter image resolution but suffers from poor contrast between coronary blood and myocardium. Data collected over >100 ms/heart beat are also susceptible to bulk cardiac and respiratory motion. To address these problems, we examined the effect of a T2 preparation prepulse (T2prep) for myocardial suppression and a shortened acquisition window on coronary definition. METHODS AND RESULTS: Eight healthy adult subjects and 5 patients with confirmed coronary artery disease (CAD) underwent free-breathing 3D MRA with and without T2prep and with 120- and 60-ms data-acquisition windows. The T2prep resulted in a 123% (P<0. 001) increase in contrast-to-noise ratio (CNR). Coronary edge definition was improved by 33% (P<0.001). Acquisition window shortening from 120 to 60 ms resulted in better vessel definition (11%; P<0.001). Among patients with CAD, there was a good correspondence with disease. CONCLUSIONS: Free-breathing, T2prep, 3D coronary MRA with a shorter acquisition window resulted in improved CNR and better coronary artery definition, allowing the assessment of coronary disease. This approach offers the potential for free-breathing, noninvasive assessment of the major coronary arteries.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

MOTIVATION: High-throughput sequencing technologies enable the genome-wide analysis of the impact of genetic variation on molecular phenotypes at unprecedented resolution. However, although powerful, these technologies can also introduce unexpected artifacts. Results: We investigated the impact of library amplification bias on the identification of allele-specific (AS) molecular events from high-throughput sequencing data derived from chromatin immunoprecipitation assays (ChIP-seq). Putative AS DNA binding activity for RNA polymerase II was determined using ChIP-seq data derived from lymphoblastoid cell lines of two parent-daughter trios. We found that, at high-sequencing depth, many significant AS binding sites suffered from an amplification bias, as evidenced by a larger number of clonal reads representing one of the two alleles. To alleviate this bias, we devised an amplification bias detection strategy, which filters out sites with low read complexity and sites featuring a significant excess of clonal reads. This method will be useful for AS analyses involving ChIP-seq and other functional sequencing assays.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We present an open-source ITK implementation of a directFourier method for tomographic reconstruction, applicableto parallel-beam x-ray images. Direct Fourierreconstruction makes use of the central-slice theorem tobuild a polar 2D Fourier space from the 1D transformedprojections of the scanned object, that is resampled intoa Cartesian grid. Inverse 2D Fourier transform eventuallyyields the reconstructed image. Additionally, we providea complex wrapper to the BSplineInterpolateImageFunctionto overcome ITKâeuro?s current lack for image interpolatorsdealing with complex data types. A sample application ispresented and extensively illustrated on the Shepp-Loganhead phantom. We show that appropriate input zeropaddingand 2D-DFT oversampling rates together with radial cubicb-spline interpolation improve 2D-DFT interpolationquality and are efficient remedies to reducereconstruction artifacts.