952 resultados para pulse measurement
Resumo:
Background: Approximately 5% of the population donates blood each year in developed countries. Recruiting and maintaining a pool of altruistic and healthy blood donors is a challenging task. Blood donation as a dynamic process must naturally co-exist with the arguably essential deferrals. Aims: To analyse a 11-year cohort of donors and blood donations in order to determine the profile of the average donor and the typical donation. Characterize the donor’s population in terms of gender, age, number of donations, most common causes for deferral and exclusion and the possible relationships between them. Establish the tendency flow of donations per year. Methods: Analysis of 95861 blood donations from 31550 donors collected between 2000 and 2010 (11 years) in the Immunohemotherapy Department of the ‘‘Centro Hospitalar Lisboa Central - Hospital de Sa˜o Jose´’’ (Lisboa, Portugal). Prior to blood donation, donors were required to fill out a form of informed consent, a questionnaire of 21 ‘‘yes or no’’ questions and were submitted to a clinical assessment and physical examination including: measurement of weight, blood pressure, pulse and capillary hemoglobin levels. Post-donation, the collected blood was tested for ALT elevation and blood-borne viral agents (HBV, HCV, HIV 1 and 2 and HTLV 1 and 2) and other infections (Treponema pallidum). Blood donors and donations were registered in a database and statistically studied in terms of: gender and age distribution, number of donations, most common causes for deferral and exclusion. The frequency of blood donations throughout the period of observation was analyzed and statistically significant relationships between the collected variables were investigated. Results: From the population of 31550 donors 61% were male and a mean age of 41.5 years (± 12.5 years) was found. From the total of 95682 blood donations collected 78% were successful while the most common causes for deferral were: donation incompatible hemoglobin levels (5% of the blood donations and 22% of deferrals), ALT elevation (3% and 14%), positive blood screening test for Treponema pallidum (1% and 6%), medication (1% and 4%), positive serological blood markers for HBV (1% and 4%), endoscopy in the previous 12 months (1% and 3%), arterial hypertension (1% and 3%), infectious conditions (1% and 3%), influenza or influenza-like symptoms (1% and 2%) and positive serological blood markers for HCV (1% and 2%). Summary/Conclusions: Several factors may have contributed to a limited number of new regular donors in the population, namely: ageing population, the alienation of the individual from the community induced by modern lifestyles and job precariousness. It is of the utmost importance to refine our blood donation campaigns according to the existing population of donors. The optimization of the blood donation potential of a population of donors must be achieved through the development of reliable and consistent screening methods. In order to appeal to new donors it is important to promote blood donations considering the profile of the regular and healthy blood donor of the existing population.
Resumo:
Dissertação para obtenção do Grau de Mestre em Engenharia Biomédica
Resumo:
PURPOSE: To determine the correlation between ocular blood flow velocities and ocular pulse amplitude (OPA) in glaucoma patients using colour Doppler imaging (CDI) waveform analysis. METHOD: A prospective, observer-masked, case-control study was performed. OPA and blood flow variables from central retinal artery and vein (CRA, CRV), nasal and temporal short posterior ciliary arteries (NPCA, TPCA) and ophthalmic artery (OA) were obtained through dynamic contour tonometry and CDI, respectively. Univariate and multiple regression analyses were performed to explore the correlations between OPA and retrobulbar CDI waveform and systemic cardiovascular parameters (blood pressure, blood pressure amplitude, mean ocular perfusion pressure and peripheral pulse). RESULTS: One hundred and ninety-two patients were included [healthy controls: 55; primary open-angle glaucoma (POAG): 74; normal-tension glaucoma (NTG): 63]. OPA was statistically different between groups (Healthy: 3.17 ± 1.2 mmHg; NTG: 2.58 ± 1.2 mmHg; POAG: 2.60 ± 1.1 mmHg; p < 0.01), but not between the glaucoma groups (p = 0.60). Multiple regression models to explain OPA variance were made for each cohort (healthy: p < 0.001, r = 0.605; NTG: p = 0.003, r = 0.372; POAG: p < 0.001, r = 0.412). OPA was independently associated with retrobulbar CDI parameters in the healthy subjects and POAG patients (healthy CRV resistance index: β = 3.37, CI: 0.16-6.59; healthy NPCA mean systolic/diastolic velocity ratio: β = 1.34, CI: 0.52-2.15; POAG TPCA mean systolic velocity: β = 0.14, CI 0.05-0.23). OPA in the NTG group was associated with diastolic blood pressure and pulse rate (β = -0.04, CI: -0.06 to -0.01; β = -0.04, CI: -0.06 to -0.001, respectively). CONCLUSIONS: Vascular-related models provide a better explanation to OPA variance in healthy individuals than in glaucoma patients. The variables that influence OPA seem to be different in healthy, POAG and NTG patients.
Resumo:
A Work Project, presented as part of the requirements for the Award of a Masters Degree in Management from the NOVA – School of Business and Economics
Resumo:
Dissertation to obtain a Master degree in Biotechnology
Resumo:
Double Degree. A Work Project presented as part of the requirements for the Award of a Masters Degree in Finance from the NOVA- School of Business and Economics and a Masters Degree in Business Engineering from Louvain school of Management
Resumo:
In any business it is very important to measure the performance and it helps to select key information to make better decisions on time. This research focuses on the design and implementation of a performance measurement system in a Portuguese medium size firm operating in the specialized health care transformation vehicles industry. From the evidence that outputs from Auto Ribeiro’s current information system is misaligned with the company’s objectives and strategy, this research tries to solve this business problem through the development of a Balanced Scorecard analysis, although there are some issues, which deserve further development.
Resumo:
The spinning rotor gauge (SRG) is one of the most interesting vacuum gauges ever made, covering a pressure range of over seven orders of magnitude, with minimal gas interference (no pumping, ionization or heating of the measured gas), and a great stability of less than 1% drift per year. But despite its remarkable properties, apparently the SRG has not been further developed since the eighties, when it gained commercial interest. In this context, this dissertation aims at providing a starting point for a new line of investigation regarding this instrument, focused on the rotor itself. A brief study of different rotor geometries is provided, including a comparison between a cylindrical rotor and a spherical one. A cylindrical spinning rotor gauge (CSRG) is then proposed, based on the original SRG, but requiring a completely new lateral damping system. A prototype was built and tested against a non calibrated reference gauge.
Resumo:
Evaluation of Cyclosporin A (CyA) blood concentration is imperative in solid organ transplantation in order to achieve maximal immunosuppression with the least side effects. We compared the results of whole blood concentrations of CyA in 50 blood samples simultaneously evaluated by the fluorescent polarization immune assay (TDx) and the enzymatic competitive immune assay (EMIT 2000). There was a strong correlation between both kits for any range of CyA blood concentration (R=0.99, p<0.001). The within-run and between-days coefficient of variation were less than 4% for both assays. The cost for each CyA measurement was 50% lower for the EMIT assay when compared to the TDx assay. We concluded that the EMIT is as accurate as the TDx in measuring CyA blood concentration and has the advantage of a lower cost, as well as the possibility of widespread access to the EMIT methodology in contrast to the TDx equipment, allowing the laboratory to perform several routines within a working day.
Resumo:
The authors report a case of a 19-year-old woman admitted for the investigation of fever and hemolytic anemia for the previous 2 months. As an inpatient, she had convulsions and sudden loss of consciousness, developing hemoptysis, hypoxia, and respiratory insufficiency. Examination showed pericardial effusions on the echocardiogram and bilateral alveolar condensations on the thoracic radiograph. A hypothetical diagnosis of systemic lupus erythematosus was made, and measurement of the antinuclear factor was requested along with daily pulse therapy methylprednisolone, in spite of which the outcome was fatal. Afterwards, the result of the antinuclear factor test was positive, with a titer of 1:5120, showing a fine punctiform pattern, fulfilling the criteria for systemic lupus erythematosus according to the American College of Rheumatology. Secondary pulmonary hemorrhage in this connective tissue disease is an uncommon but serious complication that involves a high level of mortality in spite of intensive treatment, as is also reported in the literature.
Resumo:
The effects of PMSs on the people’s behaviour represent a high degree of relevance in the context of an organization performance and success. Thus, motivational and behavioural consequences of performance measurements are far from being totally understood (Franco-Santos et al., 2012). This work project (WP) purposes going further regarding the consequences/effects on people’s behaviour of using PMSs in organizations. The researcher conducted 11 interviews to managers during a nine-month internship as a controller in a Portuguese multi-national company. The evidence from this WP suggests that the way how managers understand a PMS determines a lot the way how they behave. Data also supports that PMSs influences in several ways motivation, perceptions, participation and job-related stress of managers.
Resumo:
The innovative Horizon 2020 program sponsored by the European Union (EU) aims to promote and develop processes of waste integration in construction materials. However, several potential health hazards caused by building materials have been identified and, there-fore, there is an ongoing need to develop new recycling methods for hazardous wastes and effi-cient barriers in order to prevent toxic releases from the new construction solutions with wastes. This paper presents an overview that focus on two main aspects: the identification of the health risks related to radioactivity and heavy metals present in building materials and identification of these toxic substances in new construction solutions that contain recycled wastes. Different waste materials were selected and distinct methodologies of toxicity evaluation are presented to analyse the potential hazardous, the feasibility of using those wastes and the achievement of op-timal construction solutions involving wastes.
Resumo:
The jet energy scale (JES) and its systematic uncertainty are determined for jets measured with the ATLAS detector using proton–proton collision data with a centre-of-mass energy of s√=7 TeV corresponding to an integrated luminosity of 4.7 fb −1 . Jets are reconstructed from energy deposits forming topological clusters of calorimeter cells using the anti- kt algorithm with distance parameters R=0.4 or R=0.6 , and are calibrated using MC simulations. A residual JES correction is applied to account for differences between data and MC simulations. This correction and its systematic uncertainty are estimated using a combination of in situ techniques exploiting the transverse momentum balance between a jet and a reference object such as a photon or a Z boson, for 20≤pjetT<1000 GeV and pseudorapidities |η|<4.5 . The effect of multiple proton–proton interactions is corrected for, and an uncertainty is evaluated using in situ techniques. The smallest JES uncertainty of less than 1 % is found in the central calorimeter region ( |η|<1.2 ) for jets with 55≤pjetT<500 GeV . For central jets at lower pT , the uncertainty is about 3 %. A consistent JES estimate is found using measurements of the calorimeter response of single hadrons in proton–proton collisions and test-beam data, which also provide the estimate for pjetT>1 TeV. The calibration of forward jets is derived from dijet pT balance measurements. The resulting uncertainty reaches its largest value of 6 % for low- pT jets at |η|=4.5 . Additional JES uncertainties due to specific event topologies, such as close-by jets or selections of event samples with an enhanced content of jets originating from light quarks or gluons, are also discussed. The magnitude of these uncertainties depends on the event sample used in a given physics analysis, but typically amounts to 0.5–3 %.