840 resultados para prosthesis failure


Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE - To report the results of percutaneous occlusion of persistent ductus arteriosus with the Amplatzer prosthesis in 2 Brazilian cardiological centers. METHODS - From May 1998 to July 2000, 33 patients with clinical and laboratory diagnosis of persistent ductus arteriosus underwent attempts at percutaneous implantation of the Amplatzer prosthesis. The median age was 36 months (from 6 months to 38 years), and the median weight was 14kg (from 6 to 92kg). Sixteen patients (48.5%) were under 2 years of age at the time of the procedure. All patients were followed up with periodical clinical and echocardiographic evaluations to assess the presence and degree of residual shunt and possible complications, such as pseudocoarctation of the aorta and left pulmonary artery stenosis. RESULTS - The minimum diameter of the arterial ducts ranged from 2.5 to 7.0mm (mean of 4.0±1.0, median of 3.9). The rate of success for implantation of the prosthesis was 100%. Femoral pulse was lost in 1 patient. The echocardiogram revealed total closure prior to hospital discharge in 30 patients, and in the follow-up visit 3 months later in the 3 remaining patients. The mean follow-up duration was 6.4±3.4 months. All patients were clinically well, asymptomatic, and did not need medication. No patient had narrowing of the left pulmonary artery or of the aorta. No early or late embolic events occurred, nor did infectious endarteritis. A new hospital admission was not required for any patient. CONCLUSION - The Amplatzer prosthesis for persistent ductus arteriosus is safe and highly effective for occlusion of ductus arteriosus of varied diameters, including large ones in small symptomatic infants.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: The biventricular pacing (BVP) approach has good results in the treatment of congestive heart failure (CHF) in patients (pts) with disorders of intraventricular conduction. METHODS: We have applied BVP to 28 pts, with left ventricular pacing using minitoracotomy in 3 pts and the transvenous aproach via coronary sinus in 25 pts. The mean duration of the QRS complexes was 187 ms, in the presence of the left branch block in 22 pts, and right branch block + divisional hemiblock in 6 pts. All pts had been considerated candidates to cardiac transplantation, and were under optimized drug therapy. Sixteen pts were in Functional Class (NYHA) IV, and 12 in class III. The ejection fraction varied from 22 to 46% (average = 34%). The pacing mode employed was biventricular triple-chamber in 22 pts, and bi-ventricular dual-chamber in 6 pts (one with ICD). RESULTS: The pts were followed up for a period that ranged from 10 days to 14 months (mean 5 months). All pts presented clinical improvement after implant, chaging the NYHA Functional Class at the end of follow-up to Class I (9pts), Class II (10 pts) and Class III (6 pts). The initial mean ejection fraction have-raised to 37%. Two pts died suddenly. One patient died due to a pulmonary fungal infection. CONCLUSION: Ventricular resynchronization through BVP, improved significantly the Functional Class and, therefore, the quality of life. Assessments of myocardial function acutely performed do not reflect the clinical improvement observed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate the relationship between 24-hour ambulatory arterial blood pressure monitoring and the prognosis of patients with advanced congestive heart failure. METHODS: We studied 38 patients with NYHA functional class IV congestive heart failure, and analyzed left ventricular ejection fraction, diastolic diameter, and ambulatory blood pressure monitoring data. RESULTS: Twelve deaths occurred. Left ventricular ejection fraction (35.2±7.3%) and diastolic diameter (72.2±7.8mm) were not correlated with the survival. The mean 24-hour (SBP24), waking (SBPw), and sleeping (SBPs) systolic pressures of the living patients were higher than those of the deceased patients and were significant for predicting survival. Patients with mean SBP24, SBPv, and SBPs > or = 105mmHg had longer survival (p=0.002, p=0.01 and p=0.0007, respectively). Patients with diastolic blood pressure sleep decrements (dip) and patients with mean blood pressure dip <=6mmHg had longer survival (p=0.04 and p=0.01, respectively). In the multivariate analysis, SBPs was the only variable with an odds ratio of 7.61 (CI: 1.56; 3704) (p=0.01). Patients with mean SBP<105mmHg were 7.6 times more likely to die than those with SBP > or = 105 mmHg CONCLUSION: Ambulatory blood pressure monitoring appears to be a useful method for evaluating patients with congestive heart failure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To analyze the influence of biventricular pacing (BP) on clinical behavior, ventricular arrhythmia (VA) prevalence, and left ventricular ejection fraction (LV EF) by gated ventriculography. METHODS: Twenty-four patients with left bundle branch block (LBBB) and NYHA class III and IV underwent pacemaker implantation and were randomized either to the conventional or BP group, all receiving BP after 6 months. RESULTS: Sixteen patients were in NYHA class IV (66.6%) and 8 were in class III (33.4%). After 1-year follow-up, 14 patients were in class II (70%) and 5 were in class III (25%). Two sudden cardiac deaths occurred. A significant reduction in QRS length was found with BP (p=0.006). A significant statistical increase, from a mean of 19.13 ± 5.19% (at baseline) to 25.33 ± 5.90% (with BP) was observed in LVEF Premature ventricular contraction prevalence decreased from a mean of 10,670.00 ± 12,595.39 SD or to a mean of 3,007.00 ± 3,216.63 SD PVC/24 h with BP (p<0.05). Regarding the hospital admission rate over 1 year, we observed a significant reduction from 60. To 16 admissions with BP (p<0.05). CONCLUSION: Patients with LBBB and severe heart failure experienced, with BP, a significant NYHA class and LVEF improvement. A reduction in the hospital admission rate and VA prevalence also occurred.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: This study evaluated the effects of a new method of mitral valve replacement on left ventricular (LV) remodeling and heart failure functional class. METHODS: Eight patients (6 men) with severe mitral regurgitation from end-stage dilated cardiomyopathy underwent surgery. Five patients were in functional class (FC) IV, 2 were in FC III and 1 was in FC III/IV. Age ranged from 33 to 63 years. Both the anterior and posterior leaflets of the mitral valve were divided into hemileaflets. The resultant 4 pedicles were displaced under traction toward the left atrium and anchored between the mitral annulus and an implanted valvular prosthesis. The beating heart facilitated ideal chordae tendineae positioning. RESULTS: All patients survived and were discharged from the hospital. After a mean follow-up period of 6.5 months (1-12 m), 5 patients were in FC I; 2 in FC I/II; and 1 in FC II. The preoperative ejection fraction ranged from 19% to 30% (mean: 25.7±3.4 %), and the postoperative ejection fraction ranged from 21% to 40% (mean: 31.1± 5.8%). Doppler echocardiography showed evidence of LV remodeling in 4 patients, including lateral wall changes and a tendency of the LV cavity to return to its elliptical shape. CONCLUSION: This technique of mitral valve replacement, involving new positioning of the chordae tendineae, allowed LV remodeling and improvement in FC during this brief follow-up period.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To report the hemodynamic and functional responses obtained with clinical optimization guided by hemodynamic parameters in patients with severe and refractory heart failure. METHODS: Invasive hemodynamic monitoring using right heart catheterization aimed to reach low filling pressures and peripheral resistance. Frequent adjustments of intravenous diuretics and vasodilators were performed according to the hemodynamic measurements. RESULTS: We assessed 19 patients (age = 48±12 years and ejection fraction = 21±5%) with severe heart failure. The intravenous use of diuretics and vasodilators reduced by 12 mm Hg (relative reduction of 43%) pulmonary artery occlusion pressure (P<0.001), with a concomitant increment of 6 mL per beat in stroke volume (relative increment of 24%, P<0.001). We observed significant associations between pulmonary artery occlusion pressure and mean pulmonary artery pressure (r=0.76; P<0.001) and central venous pressure (r=0.63; P<0.001). After clinical optimization, improvement in functional class occurred (P< 0.001), with a tendency towards improvement in ejection fraction and no impairment to renal function. CONCLUSION: Optimization guided by hemodynamic parameters in patients with refractory heart failure provides a significant improvement in the hemodynamic profile with concomitant improvement in functional class. This study emphasizes that adjustments in blood volume result in imme-diate benefits for patients with severe heart failure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: The 6-minute walk test is an way of assessing exercise capacity and predicting survival in heart failure. The 6-minute walk test was suggested to be similar to that of daily activities. We investigated the effect of motivation during the 6-minute walk test in heart failure. METHODS: We studied 12 males, age 45±12 years, ejection fraction 23±7%, and functional class III. Patients underwent the following tests: maximal cardiopulmonary exercise test on the treadmill (max), cardiopulmonary 6-minute walk test with the walking rhythm maintained between relatively easy and slightly tiring (levels 11 and 13 on the Borg scale) (6EB), and cardiopulmonary 6-minute walk test using the usual recommendations (6RU). The 6EB and 6RU tests were performed on a treadmill with zero inclination and control of the velocity by the patient. RESULTS: The values obtained in the max, 6EB, and 6RU tests were, respectively, as follows: O2 consumption (ml.kg-1.min-1) 15.4±1.8, 9.8±1.9 (60±10%), and 13.3±2.2 (90±10%); heart rate (bpm) 142±12, 110±13 (77±9%), and 126±11 (89±7%); distance walked (m) 733±147, 332±66, and 470±48; and respiratory exchange ratio (R) 1.13±0.06, 0.9±0.06, and 1.06±0.12. Significant differences were observed in the values of the variables cited between the max and 6EB tests, the max and 6RU tests, and the 6EB and 6RU tests (p<0.05). CONCLUSION: Patients, who undergo the cardiopulmonary 6-minute walk test and are motivated to walk as much as they possibly can, usually walk almost to their maximum capacity, which may not correspond to that of their daily activities. The use of the Borg scale during the cardiopulmonary 6-minute walk test seems to better correspond to the metabolic demand of the usual activities in this group of patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PhD in Sciences Specialty in Physics

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: Exercise training programs have been proposed as adjuncts to treatment of heart failure. The effects of a 3-month-exercise-training-program with 3 exercise sessions per week were assessed in patients with stable systolic chronic heart failure. METHODS: We studied 24 patients with final left ventricle diastolic diameter of 70±10mm and left ventricular ejection fraction of 37±4%. Mean age was 52±16 years. Twelve patients were assigned to an exercise training group (G1), and 12 patients were assigned to a control group (G2). Patients underwent treadmill testing, before and after exercise training, to assess distance walked, heart rate, systolic blood pressure, and double product. RESULTS: In G2 group, before and after 3 months, we observed, respectively distance walked, 623±553 and 561± 460m (ns); peak heart rate, 142±23 and 146± 33b/min (ns); systolic blood pressure, 154±36 and 164±26 mmHg (ns); and double product, 22211± 6454 and 24293±7373 (ns). In G1 group, before and after exercise, we observed: distance walked, 615±394 and 970± 537m (p<0.003) peak heart rate, 143±24 and 143±29b/min (ns); systolic blood pressure, 136±33 and 133±24 mmHg (ns); and double product, 19907± 7323 and 19115±5776, respectively. Comparing the groups, a significant difference existed regarding the variation in the double product, and in distance walked. CONCLUSION: Exercise training programs in patients with heart failure can bring about an improvement in physical capacity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To assess the relation between P-wave and QT dispersions in elderly patients with heart failure. METHODS: Forty-seven elderly patients (75.6±6 years) with stable heart failure in NYHA functional classes II or III and with ejection fractions of 37±6% underwent body surface mapping to analyze P-wave and QT dispersions. The degree of correlation between P-wave and QT dispersions was assessed, and P-wave dispersion values in patients with QT dispersion greater than and smaller than 100 ms were compared. RESULTS: The mean values of P-wave and QT dispersions were 54±14 ms and 68±27 ms, respectively. The correlation between the 2 variables was R=0.41 (p=0.04). In patients with QT dispersion values > 100 ms, P-wave dispersion was significantly greater than in those with QT dispersion values < 100 ms (58±16 vs 53±12 ms, p=0.04 ). CONCLUSION: Our results suggest that, in elderly patients with heart failure, a correlation between the values of P-wave and QT dispersions exists. These findings may have etiopathogenic, pathophysiologic, prognostic, and therapeutic implications, which should be investigated in other studies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To determine the utility of B-type natriuretic peptide (BNP) in the diagnosis of congestive heart failure (CHF) in patients presenting with dyspnea to an emergency department (ED). METHODS: Seventy patients presenting with dyspnea to an ED from April to July 2001 were included in the study. Mean age was 72±16 years and 33 (47%) were male. BNP was measured in all patients at the moment of admission to the ED. Emergency-care physicians, blinded to BNP values, were required to assign a probable initial diagnosis. A cardiologist retrospectively reviewed the data (blinded to BNP measurements) and assigned a definite diagnosis, which was considered the gold standard for assessing the diagnostic performance of BNP. RESULTS: The mean BNP concentration was higher in patients with CHF (n=36) than in those with other diagnoses (990±550 vs 80±67 pg/mL, p<0.0001). Patients with systolic dysfunction had higher BNP levels than those with preserved systolic function (1,180±641 vs 753±437 pg/mL, p=0.03). At a blood concentration of 200 pg/mL, BNP showed a sensitivity of 100%, specificity of 97.1%, positive predictive value of 97.3%, and negative predictive value of 100%. The application of BNP could have potentially corrected all 16 cases in which the diagnosis was missed by the emergency department physician. CONCLUSION: BNP measurement is a useful tool in the diagnosis of CHF in patients presenting to the ED with dyspnea.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To differentiate the nature of functional cardiorespiratory limitations during exercise in individuals with chronic obstructive pulmonary disease (COPD) or congestive heart failure (CHF) and to determine indicators that may help their classifications. METHODS: The study comprised 40 patients: 23 with COPD and 17 with CHF. All individuals underwent maximal cardiopulmonary exercise testing on a treadmill. RESULTS: The values of peak gas exchange ratio (R peak), peak carbon dioxide production (VCO2 peak), and peak oxygen ventilatory equivalent (V E O2 peak) were higher in the patients with CHF than in those with COPD, and, therefore, those were the variables that characterized the differences between the groups. For group classification, the differentiating functions with the R peak, VCO2 peak (L/min), and V E O2 peak variables were used as follows: group COPD: - 44.886 + 78.832 x R peak + 5.442 x VCO2 peak + 0.336 x V E O2 peak; group CHF: - 69.251 + 89.740 x R peak + 8.461 x VCO2 peak + 0.574 x V E O2 peak. The differentiating function, whose result is greater, correctly classifies the patient's group as 90%. CONCLUSION: The R peak, VCO2 peak, and V E O2 peak values may be used to identify the cause of the functional cardiorespiratory limitations in patients with COPD and CHF.