877 resultados para new method


Relevância:

70.00% 70.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

70.00% 70.00%

Publicador:

Resumo:

This article introduces a new method for 3-dimensional dental cast analysis, by using a mechanical 3-dimensional digitizer, MicroScribe 3DX (Immersion, San Jose, Calif), and TIGARO software (not yet released, but available from the author at hayasaki@dent.kyushu-u.ac.jp). By digitizing points on the model, multiple measurements can be made, including tooth dimensions; arch length, width, and perimeter; curve of Spee; overjet and overbite; and anteroposterior discrepancy. The bias of the system can be evaluated by comparing the distance between 2 points as determined by the new system and as measured with digital calipers. Fifteen pairs of models were measured digitally and manually, and the bias was evaluated by comparing the variances of both methods and checking for the type of error obtained by each method. No systematic errors were found. The results showed that the method is accurate, and it can be applied to both clinical practice and research. Copyright © 2005 by the American Association of Orthodontists.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Studies carried out with glass electrode in anhydrous ethanol and ethanol-water solutions for measuring pH values have shown that this parameter depends on the solution composition, the contact time with the solution, the utilized temperature, and the type of electrolyte used. It was also observed that the glass electrode behavior in an acid medium differs from an alkaline medium. These studies provided correction factors for pH values from 2 to 12, allowing the realization of proper measurements of the hydrogen ionic activity in the ethanol-water and anhydrous ethanol solutions. However, these correction factors could not be applied to the fuel ethanol. Alternatively, a new method was developed for the correction of the pH values, which can be applied in hydrous and anhydrous fuel ethanol samples. Copyright © 2011 by ASTM International.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

This article presents a new method to detect damage in structures based on the electromechanical impedance principle. The system follows the variations in the output voltage of piezoelectric transducers and does not compute the impedance itself. The proposed system is portable, autonomous, versatile, and could efficiently replace commercial instruments in different structural health monitoring applications. The identification of damage is performed by simply comparing the variations of root mean square voltage from response signals of piezoelectric transducers, such as lead zirconate titanate patches bonded to the structure, obtained for different frequencies of the excitation signal. The proposed system is not limited by the sampling rate of analog-to-digital converters, dispenses Fourier transform algorithms, and does not require a computer for processing, operating autonomously. A low-cost prototype based on microcontroller and digital synthesizer was built, and experiments were carried out on an aluminum structure and excellent results have been obtained. © The Author(s) 2012.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Aim: This clinical report presents a new method for retrieving separated instruments from the root canal with minimally invasive procedures. Background: The presence of separated instrument in root canal may interfere in the endodontic treatment prognosis. There are several recommended methods to retrieve separated instruments, but some are difficult in clinically practice. Case report: This study describes two cases of separated instrument removal from the root canal using a stainless-steel prepared needle associated with a K-file. Case 1 presented a fractured gutta-percha condenser within the mandibular second premolar, it was separated during incorrect intracanal medication calcium hydroxide placement. Case 2 had a fractured sewing needle within the upper central incisor that the patient used to remove food debris from the root canal. After cervical preparation, the fractured instruments were fitted inside a prepared needle and then an endodontic instrument (#25 K-file) was adapted with clockwise turning motion between the needle inner wall and the fragment. Conclusion: The endodontic or atypical nonendodontic separated instrument may be easily pull on of the root canal using a single and low cost device. Clinical significance: The methods for retrieving separated instruments from root canal are difficult and destructive procedures. The present case describes a simple method to solve this problem.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

70.00% 70.00%

Publicador:

Resumo:

SUMMARY. A new method was developed to evaluate the total antioxidant activity in plant extracts, which was based on radical scavenging using 2,2’-azinobis-(3-ethylbenzothiazoline)-6-sulfonic acid. The proposed method was linear in the range of 0.86 to 26.0 μg/mL, displaying a correlation coefficient of 0.999. Moreover, the accuracy and precision analysis showed agreement with ANVISA guidelines (96.66 to 98.46 % and < 5.0%, respectively). The method demonstrated sensitivity, robustness and efficiency in detecting low concentrations of plant extracts (detection and quantification limit of 0.86 and 2.87 μg/mL, respectively) that may be present in pharmaceuticals and cosmetics preparations, again in agreement with ANVISA. In addition, the assay is inexpensive and easy to perform.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

In this paper, a new algebraic-graph method for identification of islanding in power system grids is proposed. The proposed method identifies all the possible cases of islanding, due to the loss of a equipment, by means of a factorization of the bus-branch incidence matrix. The main features of this new method include: (i) simple implementation, (ii) high speed, (iii) real-time adaptability, (iv) identification of all islanding cases and (v) identification of the buses that compose each island in case of island formation. The method was successfully tested on large-scale systems such as the reduced south Brazilian system (45 buses/72 branches) and the south-southeast Brazilian system (810 buses/1340 branches). (C) 2011 Elsevier Ltd. All rights reserved.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Chromosomal translocations require formation and joining of DNA double strand breaks (DSBs). These events disrupt the integrity of the genome and are involved in producing leukemias, lymphomas and sarcomas. Translocations are frequent, clonal and recurrent in mature B cell lymphomas, which bear a particularly high DNA damage burden by virtue of activation-induced cytidine deaminase (AID) expression. Despite the ubiquity of genomic rearrangements, the forces that underlie their genesis are not well understood. Here, we provide a detailed description of a new method for studying these events, translocation capture sequencing (TC-Seq). TC-Seq provides the means to document chromosomal rearrangements genome-wide in primary cells, and to discover recombination hotspots. Demonstrating its effectiveness, we successfully estimate the frequency of c-myc/IgH translocations in primary B cells, and identify hotspots of AID-mediated recombination. Furthermore. TC-Seq can be adapted to generate genome-wide rearrangement maps in any cell type and under any condition. (C) 2011 Elsevier B.V. All rights reserved.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Pollen traps used for harvesting pollen from Apis mellifera do not work for stingless bees, as most species have small entrances and rapidly deposit large quantities of propolis at any barrier in front of the nest. Some stingless beekeepers harvest pollen by removing it directly from pollen pots, but this pollen is normally fermented and unpalatable. The aim of this study was to test a new method for harvesting pollen from stingless bee colonies before it begins to ferment. Colonies of Scaptotrigona depilis were removed and replaced by empty hives, which were occupied by the returning foragers and used for storing pollen and nectar. After one week, the pollen and honey were harvested directly from the storing pots and weighed. On average, the colonies produced 8.7 g of honey and 54.2 g of unfermented pollen (n = 10). This method is a viable option for harvesting unfermented pollen from stingless bees, especially with species that harvest large amounts of pollen. The unfermented pollen of S. depilis was well received in taste tests, receiving higher scores than fermented pollen, and similar scores to A. mellifera pollen, so could have great commercial possibilities. It is also a good method for studying the foraging of stingless bees because the amount of harvested food can be easily and precisely quantified.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

This paper addresses the m-machine no-wait flow shop problem where the set-up time of a job is separated from its processing time. The performance measure considered is the total flowtime. A new hybrid metaheuristic Genetic Algorithm-Cluster Search is proposed to solve the scheduling problem. The performance of the proposed method is evaluated and the results are compared with the best method reported in the literature. Experimental tests show superiority of the new method for the test problems set, regarding the solution quality. (c) 2012 Elsevier Ltd. All rights reserved.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

A new method for analysis of scattering data from lamellar bilayer systems is presented. The method employs a form-free description of the cross-section structure of the bilayer and the fit is performed directly to the scattering data, introducing also a structure factor when required. The cross-section structure (electron density profile in the case of X-ray scattering) is described by a set of Gaussian functions and the technique is termed Gaussian deconvolution. The coefficients of the Gaussians are optimized using a constrained least-squares routine that induces smoothness of the electron density profile. The optimization is coupled with the point-of-inflection method for determining the optimal weight of the smoothness. With the new approach, it is possible to optimize simultaneously the form factor, structure factor and several other parameters in the model. The applicability of this method is demonstrated by using it in a study of a multilamellar system composed of lecithin bilayers, where the form factor and structure factor are obtained simultaneously, and the obtained results provided new insight into this very well known system.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

This thesis is based on five papers addressing variance reduction in different ways. The papers have in common that they all present new numerical methods. Paper I investigates quantitative structure-retention relationships from an image processing perspective, using an artificial neural network to preprocess three-dimensional structural descriptions of the studied steroid molecules. Paper II presents a new method for computing free energies. Free energy is the quantity that determines chemical equilibria and partition coefficients. The proposed method may be used for estimating, e.g., chromatographic retention without performing experiments. Two papers (III and IV) deal with correcting deviations from bilinearity by so-called peak alignment. Bilinearity is a theoretical assumption about the distribution of instrumental data that is often violated by measured data. Deviations from bilinearity lead to increased variance, both in the data and in inferences from the data, unless invariance to the deviations is built into the model, e.g., by the use of the method proposed in paper III and extended in paper IV. Paper V addresses a generic problem in classification; namely, how to measure the goodness of different data representations, so that the best classifier may be constructed. Variance reduction is one of the pillars on which analytical chemistry rests. This thesis considers two aspects on variance reduction: before and after experiments are performed. Before experimenting, theoretical predictions of experimental outcomes may be used to direct which experiments to perform, and how to perform them (papers I and II). After experiments are performed, the variance of inferences from the measured data are affected by the method of data analysis (papers III-V).