946 resultados para macular carotenoids
Resumo:
With an ageing population, the number of age-related macular disease (ARMD) cases will inevitably rise. This gives greater impetus for the need to identify the disease earlier and assess treatments to slow disease progression. Differing electroretinogram (ERG) modalities have been reviewed in relation to the objective assessment of retinal function in ARMD and for monitoring the effectiveness of clinical interventions. Conflicting results have been found with regard to the efficacy of ERG findings in the investigation of ARMD in previous years. The newer multifocal ERG paradigm provides spatial topographical information about retinal function in ARMD. It has shown promising results in monitoring effectiveness of clinical interventions and studies are continuing in this area. Better knowledge of retinal function in ARMD may lead to enhanced treatments at each phase of the disease.
Resumo:
Aim: To investigate the experiences of people with macular disease within the British healthcare system. Method: The Macular Disease Society Questionnaire, a self completion questionnaire designed to survey the experiences of people with macular disease, was sent to 2000 randomly selected members of the Macular Disease Society. The questionnaire incorporated items about people's experiences with health professionals and the information and support provided by them at the time of diagnosis and thereafter. Results: Over 50% thought their consultant eye specialist was not interested in them as a person and 40% were dissatisfied with their diagnostic consultation. 185 people thought their general practitioner (GP) was well informed about macular disease but twice as many people thought their GP was not well informed. About an equal number of people thought their GP was supportive as those who thought their GP was not supportive. A total of 1247 people were told "nothing can be done to help with your macular disease." A number of negative emotional reactions were experienced by those people as a result, with 61% of them reporting feeling anxious or depressed. Of 282 people experiencing visual hallucinations after diagnosis with macular disease, only 20.9% were offered explanations for them. Concluslons: Many people with macular disease have unsatisfactory experiences of the healthcare system. Many of the reasons for dissatisfaction could be resolved by healthcare professionals if they were better informed about macular disease and had a better understanding of and empathy with patients' experiences.
Resumo:
Objective: The aim of the study is to determine the effect of lutein combined with vitamin and mineral supplementation on contrast sensitivity in people with age-related macular disease (ARMD). Design: A prospective, 9-month, double-masked randomized controlled trial. Setting: Aston University, Birmingham, UK and a UK optometric clinical practice. Subjects: Age-related maculopathy (ARM) and atrophic age-related macular degeneration (AMD) participants were randomized (using a random number generator) to either placebo (n = 10) or active (n=15) groups. Three of the placebo group and two of the active group dropped out. Interventions: The active group supplemented daily with 6 mg lutein combined with vitamins and minerals. The outcome measure was contrast sensitivity (CS) measured using the Pelli-Robson chart, for which the study had 80% power at the 5% significance level to detect a change of 0.3log units. Results: The CS score increased by 0.07 ± 0.07 and decreased by 0.02 ± 0.18 log units for the placebo and active groups, respectively. The difference between these values is not statistically significant (z = 0.903, P = 0.376). Conclusion: The results suggest that 6 mg of lutein supplementation in combination with other antioxidants is not beneficial for this group. Further work is required to establish optimum dosage levels.
Resumo:
The purpose of this study was to determine if there was an objective difference in reading between four commonly available lamps, of varying spectral radiance, for 13 subjects with age-related maculopathy (ARM) or non-exudative age-related macular degeneration (AMD) - logMAR visual acuity between 0.04 and 0.68. At a constant illuminance of 2000 lux, there was no interaction between ARM and AMD subgroups and no statistically significant difference between the lamps: standard (clear envelope) incandescent, daylight simulation (blue tint envelope) incandescent, compact fluorescent and halogen incandescent, for any reading outcome measure (threshold print size p = 0.67, critical print size p = 0.74, acuity reserve p = 0.84 and mean reading rate p = 0.78). For lamps typically used in low-vision rehabilitation, a clinically significant effect of spectral radiance on reading for people with ARM or non-exudative AMD is unlikely. © 2007 The College of Optometrists.
Resumo:
The role of nutritional supplementation in prevention of onset or progression of ocular disease is of interest to health care professionals and patients. The aim of this review is to identify those antioxidants most appropriate for inclusion in an ideal ocular nutritional supplement, suitable for those with a family history of glaucoma, cataract, or age-related macular disease, or lifestyle factors predisposing onset of these conditions, such as smoking, poor nutritional status, or high levels of sunlight exposure. It would also be suitable for those with early stages of age-related ocular disease. Literature searches were carried out on Web of Science and PubMed for articles relating to the use of nutrients in ocular disease. Those highlighted for possible inclusion were vitamins A, B, C and E, carotenoids beta-carotene, lutein, and zeaxanthin, minerals selenium and zinc, and the herb, Ginkgo biloba. Conflicting evidence is presented for vitamins A and E in prevention of ocular disease; these vitamins have roles in the production of rhodopsin and prevention of lipid peroxidation respectively. B vitamins have been linked with a reduced risk of cataract and studies have provided evidence supporting a protective role of vitamin C in cataract prevention. Beta-carotene is active in the prevention of free radical formation, but has been linked with an increased risk of lung cancer in smokers. Improvements in visual function in patients with age-related macular disease have been noted with lutein and zeaxanthin supplementation. Selenium has been linked with a reduced risk of cataract and activates the antioxidant enzyme glutathione peroxidase, protecting cell membranes from oxidative damage while zinc, although an essential component of antioxidant enzymes, has been highlighted for risk of adverse effects. As well as reducing platelet aggregation and increasing vasodilation, Gingko biloba has been linked with improvements in pre-existing field damage in some patients with normal tension glaucoma. We advocate that vitamins C and E, and lutein/zeaxanthin should be included in our theoretically ideal ocular nutritional supplement.
Resumo:
Purpose: To investigate the effects of light filters on reading speed in normal and low vision due to age-related macular degeneration (AMD). Methods: Reading speed was determined for 12 subjects with normal vision and 12 subjects with non-exudative AMD using stationary lowercase nonsensical print in Times Roman font and four light filters; a yellow Corning Photochromic Filter (CPF) 450, a grey neural density (ND) filter, an individual filter obtained using the Intuitive Colorimeter® and a clear filter. Results: There was no statistically significant light filter effect on reading speed for the normal subjects. The AMD group demonstrated a statistically significant 5% average improvement in reading speed with the CPF450 compared with the other filters although some AMD subjects had improvements of 10-15%. Conclusions: Light filters obtained using the Intuitive Colorimeter® performed poorly when compared with the CPF450, ND and clear filters for both the study groups. For the AMD group, average reading speed was statistically greater with the CPF450 than the other filters, however it is questionable whether the improvement (5%) would be clinically significant. As some of the subjects with AMD had greater improvements with the CPF450 we advocate clinical assessment of light filters using existing protocols on an individual basis. © 2004 The College of Optometrists.
Resumo:
PURPOSE: To determine the objective measures of visual function that are most relevant to subjective quality of vision and perceived reading ability in patients with acquired macular disease. METHODS: Twenty-eight patients with macular disease underwent a comprehensive assessment of visual function. The patients also completed a vision-related quality-of-life questionnaire that included a section of general questions about perceived visual performance and a section with specific questions on reading. RESULTS: Results of all tests of vision correlated highly with reported vision-related quality-of-life impairment. Low-contrast tests explained most of the variance in self-reported problems with reading. Text-reading speed correlated highly with overall concern about vision. CONCLUSIONS: Reading performance is strongly associated with vision-related quality of life. High-contrast distance acuity is not the only relevant measure of visual function in relation to the perceived visual performance of a patient with macular disease. The results suggest the importance of print contrast, even over print size, in reading performance in patients with acquired macular disease.
Resumo:
This review compares the results of studies that have investigated the impact of lutein and zeaxanthin supplementation on macular pigment optical density (MPOD) with those that have investigated the reliability of techniques used to measure macular pigment optical density. The review will focus on studies that have used heterochromatic flicker photometry for measurement of macular pigment optical density, as this is the only technique that is currently available commercially to clinicians. We identified articles that reported on supplementation with lutein and/or zeaxanthin and/or meso-zeaxanthin on macular pigment optical density measurement techniques published in peer-reviewed journals, through a multi-staged, systematic approach. Twenty-four studies have investigated the repeatability of MPOD measurements using heterochromatic flicker photometry. Of these, 10 studies provided a coefficient of repeatability or data from which the coefficient could be calculated, with a range in values of 0.06 to 0.58. The lowest coefficient of repeatability assessed on naïve subjects alone was 0.08. These values tell us that, at best, changes greater than 0.08 can be considered clinically significant and at worst, only changes greater than 0.58 can be considered clinically significant. Six studies assessed the effect of supplementation with up to 20 mg/day lutein on macular pigment optical density measured using heterochromatic flicker photometry and the mean increase in macular pigment optical density ranged from 0.025 to 0.09. It seems reasonable to conclude that the chance of eliciting an increase in macular pigment optical density during six months of daily supplementation with between 10 and 20 mg lutein that is of sufficient magnitude to be detected by using heterochromatic flicker photometry on an individual basis is small. Commercially available heterochromatic flicker photometers for macular pigment optical density assessment in the clinical environment appear to demonstrate particularly poor coefficient of repeatability values. Clinicians should exercise caution when considering the purchase of these instruments for potential monitoring of macular pigment optical density in response to supplementation in individual patients.
Resumo:
PURPOSE: To investigate the MacDQoL test-retest reliability and sensitivity to change in vision over a period of one year in a sample of patients with age-related macular degeneration (AMD). DESIGN: A prospective, observational study. METHOD: Patients with AMD from an ophthalmologist's list (n = 135) completed the MacDQoL questionnaire by telephone interview and underwent a vision assessment on two occasions, one year apart. RESULTS: Among participants whose vision was stable over one year (n = 87), MacDQoL scores at baseline and follow-up were highly correlated (r = 0.95; P < .0001). Twelve of the 22 scale items had intraclass correlations of >.80; only two were correlated <.7. There was no difference between baseline and follow-up scores (P = .85), indicating excellent test-retest reliability. Poorer quality of life (QoL) at follow-up, measured by the MacDQoL present QoL overview item, was associated with deterioration in both the better eye and binocular distance visual acuity [VA] (r = 0.29; P = .001, r = 0.21; P = .016, respectively; n = 135). There was a positive correlation between deterioration in the Mac. DQoL average weighted impact score and deterioration in both binocular near VA and reading speed (r = 0.20; P = .019, r = 0.18; P = .041, respectively; n = 135). CONCLUSION: The MacDQoL has excellent test-retest reliability. Its sensitivity to change in vision status was demonstrated in correlational analyses. The measure indicates that the negative impact of AMD on QoL increases with increasing severity of visual impairment.
Resumo:
Purpose. To assess the relationship between macular pigment optical density (MPOD) and blood markers for antioxidant defense in otherwise healthy volunteers. Methods. Forty-seven healthy volunteers were subjected to blood analysis to detect the level of circulating glutathione in its reduced (GSH) and oxidized (GSSG) forms. The level of MPOD was measured using heterochromatic flicker photometry. Systemic blood pressure (BP) parameters, heart rate (HR), body mass index (BMI), and plasma levels of total, HDL, and LDL cholesterol and triglycerides (TGs) were also determined. Results. A simple correlation model revealed that the level of MPOD correlated significantly and positively with both GSH (P < 0.001) and t-GSH (P < 0.001) levels but not with those of GSSG (P > 0.05). Age, sex, systemic BP parameters, HR, BMI, and plasma levels of cholesterol and TGs did not have any influence on either MPOD or glutathione levels (all P > 0.05). In addition, a forward stepwise multiple regression analysis showed MPOD to have a significantly and independent correlation with GSH levels (ß = 0.63; P < 0.001). Conclusions. In otherwise healthy older individuals, there is a positive correlation between local and systemic antioxidant defense mechanisms.
Resumo:
Background/aims. The MacuScope uses a psychophysical technique called heterochromic flicker photometry to measure macular pigment optical density (MPOD). Our aim was to determine the measurement variability (noise) of the MacuScope. Methods. Thirty-eight normally sighted participants who ranged in age from 19 to 46 years (25.7±7.6 years) were recruited from staff and students of Aston University. Data were collected by two operators, HB and JA, in two sessions separated by 1 week in order to assess test repeatability and reproducibility. Results. The overall mean MPOD for the cohort was 0.47±0.14. There was a significant negative correlation between MacuScope MPOD readings and age (r=-0.368, p=0.023). Coefficients were 0.45 and 0.58 for repeatability, and 0.49 and 0.36 for reproducibility. For each pair of results, there was a significant positive correlation between mean and difference MPOD values. Conclusions. If MPOD is being monitored over time then any change less than 0.58 units should not be considered clinically significant as it is very likely to be due to instrument noise. The size of the coefficient appears to be positively correlated with MPOD.
Resumo:
Background: Age-related macular degeneration (ARMD) is the leading cause of visual disability in people over 60 years of age in the developed world. The success of treatment deteriorates with increased latency of diagnosis. The purpose of this study was to determine the reliability of the macular mapping test (MMT), and to investigate its potential as a screening tool. Methods: The study population comprised of 31 healthy eyes of 31 participants. To assess reliability, four macular mapping test (MMT) measurements were taken in two sessions separated by one hour by two practitioners, with reversal of order in the second session. MMT readings were also taken from 17 age-related maculopathy (ARM), and 12 AMD affected eyes. Results: For the normal cohort, average MMT scores ranged from 85.5 to 100.0 MMT points. Scores ranged from 79.0 to 99.0 for the ARM group and from 9.0 to 92.0 for the AMD group. MMT scores were reliable to within ± 7.0 points. The difference between AMD affected eyes and controls (z = 3.761, p = < 0.001) was significant. The difference between ARM affected eyes and controls was not significant (z = -0.216, p = 0.829). Conclusion: The reliability data shows that a change of 14 points or more is required to indicate a clinically significant change. This value is required for use of the MMT as an outcome measure in clinical trials. Although there was no difference between MMT scores from ARM affected eyes and controls, the MMT has the advantage over the Amsler grid in that it uses a letter target, has a peripheral fixation aid, and it provides a numerical score. This score could be beneficial in office and home monitoring of AMD progression, as well as an outcome measure in clinical research. © 2005 Bartlett et al; licensee BioMed Central Ltd.
Resumo:
As a research group with no commercial interest in any macular pigment optical density (MPOD) measurement devices or nutritional supplements, we feel that we were well-placed to carry out an independent clinical assessment of the reliability of the MPS 9000 (Tinsley Precision Instruments, Redhill, Surrey, UK). Our study was prompted by the fact that we could not find any reported coefficient of repeatability value within the literature, and none was provided by the manufacturer.1 We had planned to use this instrument in our own research studies investigating the impact of nutritional supplementation on MPOD. For this purpose, we needed …
Resumo:
A literature review revealed that very little work has been conducted to investigate the possible benefits of coloured interventions on reading performance in low vision due to ARMD, under conditions that are similar to the real world reading environment. Further studies on the use of colour, as a rehabilitative intervention in low vision would therefore be useful. A series of objective, subject based, age-similar controlled experiments were used to address the primary aims. Trends in some of the ARMD data suggested better reading performance with blue or green illuminance but there were also some individuals who performed better with yellow, or with illuminance of reduced intensity. Statistically, better reading in general occurred with a specialised yellow photochromic lens and also a clear lens than with a fixed lens or a neutral density filter. No reading advantage was gained from using the coloured screen facility of a video-magnifier. Some subjects with low vision were found to have co-existent binocular vision anomalies, which may have caused reading difficulties similar to those produced by ARMD. Some individuals with ARMD benefited from the use of increased local illuminance produced by either a standard tungsten or compact fluorescent lamp. No reading improvement occurred with a daylight simulation tungsten lamp. The Intuitive Colorimeter® can be used to detect and map out colour vision discrimination deficiency in ARMD and the Humphrey 630 Visual Field Analyser can be used to analyse the biocular visual field in subjects with ARMD. Some experiments highlighted a positive effect of a blue intervention in reading with ARMD.
Resumo:
Macular pigment has been the focus of much attention in recent years, as a potential modifiable risk factor for age-related macular degeneration. This interest has been heightened by the ability to measure macular pigment optical density (MPOD) in vivo.