978 resultados para high-speed measurement of polarized state


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Total immunoglobulin A in saliva (s-IgA) is normally assayed using an enzyme-linked immunosorbent assay. We have investigated methodological issues relating to the use of particle-enhanced nephelometric immunoassay (PENIA)
to measure s-IgA in whole unstimulated saliva and determine its reference range.

Methods: Whole unstimulated resting saliva was collected to determine sample stability (temperature, time, effect of a protease inhibitor), limit of quantitation (LOQ), assay precision and analytical variation. The reference range for 134 healthy adults was determined.

Results: Linearity was excellent (4–10.3 mg L21, P, 0.001; R2 ¼ 0.997) and without significant bias (mean of 20.7%). The lowest intra- and inter-analytical coefficients of variation were 1.8% and 7.5% and LOQ was 1.4 mg L21. The concentration of s-IgA is stable at room temperature for up to 6 h, at 48C for 48 h, at 248C for two weeks and at 2808C for up to 1.3 yr. There is no evidence that a protease inhibitor increases the stability or that repeated freeze–thawing cycles degrade sample quality. The reference ranges for s-IgA concentration, s-IgA secretion, s-IgA:albumin and s-IgA:osmolality were 15.9–414.5 mg L21, 7.2–234.9 mg min21, 0.4–19 and 0.6–8.9, respectively.

Conclusion:
Automated PENIA assay of s-IgA is precise and accurate. High stability of collected saliva samples and the ease and speed of the assay make this an ideal method for use in athletic and military training situations. The convenience of measuring albumin and IgA on the same analytical platform adds to the practicability of the test.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We collaborate with environmental scientists to study the hydrodynamics and water quality in an urban district, where the surface wind distribution is an essential input but undergoes high spatial and temporal variations due to the complex urban landform created by surrounding buildings. In this work, we study an optimal sensor placement scheme to measure the wind distribution over a large urban reservoir with a limited number of wind sensors. Unlike existing sensor placement solutions that assume Gaussian process of target phenomena, this study measures the wind which inherently exhibits strong non-Gaussian yearly distribution. By leveraging the local monsoon characteristics of wind, we segment a year into different monsoon seasons which follow a unique distribution respectively. We also use computational fluid dynamics to learn the spatial correlation of wind in the presence of surrounding buildings. The output of sensor placement is a set of the most informative locations to deploy the wind sensors, based on the readings of which we can accurately predict the wind over the entire reservoir surface in real time. 10 wind sensors are finally deployed around or on the water surface of an urban reservoir. The in-field measurement results of more than 3 months suggest that the proposed sensor placement and spatial prediction approach provides accurate wind measurement which outperforms the state-of-the-art Gaussian model based or interpolation based approaches.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

To assess stable effects of self-management programs, measurement instruments should primarily capture the attributes of interest, for example, the self-management skills of the measured persons. However, measurements of psychological constructs are always influenced by both aspects of the situation (states) and aspects of the person (traits). This study tests whether the Health Education Impact Questionnaire (heiQ™), an instrument assessing a wide range of proximal outcomes of self-management programs, is primarily influenced by person factors instead of situational factors. Furthermore, measurement invariance over time, changes in traits and predictors of change for each heiQ™ scale were examined.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We study the water quality in an urban district, where the surface wind distribution is an essential input but undergoes high spatial and temporal variations due to the impact of surrounding buildings. In this work, we develop an optimal sensor placement scheme to measure the wind distribution over a large urban reservoir using a limited number of wind sensors. Unlike existing solutions that assume Gaussian process of target phenomena, this study measures the wind that inherently exhibits strong non-Gaussian yearly distribution. By leveraging the local monsoon characteristics of wind, we segment a year into different monsoon seasons that follow a unique distribution respectively. We also use computational fluid dynamics to learn the spatial correlation of wind. The output of sensor placement is a set of the most informative locations to deploy the wind sensors, based on the readings of which we can accurately predict the wind over the entire reservoir in real time. Ten wind sensors are deployed. The in-field measurement results of more than 3 months suggest that the proposed sensor placement and spatial prediction scheme provides accurate wind measurement that outperforms the state-of-the-art Gaussian model based on interpolation-based approaches.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The methanolic extract of the leaves of the medicinal plant Byrsonima crassa (Malpighiaceae) contain flavonoids with antioxidant activity. They were separated in a preparative scale using high-speed counter-current chromatography. The optimum solvent system used was composed of a mixture of ethyl acetate-n-propanol-water (140:8:80 (v/v/v)) and led to a successful separation between monoglucosilated flavonoids (quercetin-3-O-alpha-L-arabinoside, quercetin-3-O-beta-D-galactoside) and the biflavonoid amentoflavone in only 3.5 h. The purities of quercetin-3-O-alpha-L-arabinoside (95 mg), quercetin-3-O-beta-D-galactoside (16 mg) and the biflavonoid amentoflavone (114 mg) were all isolated at purity over 95%. Identification was performed by H-1 NMR, C-13 NMR and UV analyses. (C) 2004 Published by Elsevier B.V.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Statement of problem. The use of ultrasonic tips has become an alternative for cavity preparation. However, there are concerns about this type of device, particularly with respect to intrapulpal temperatures and cavity preparation time.Purpose. The purpose of this study was to analyze pulpal temperature increases generated by an ultrasonic cavity preparation with chemical vapor deposition (CVD) tips, in comparison to preparation with a high-speed handpiece with a diamond rotary cutting instrument. The time required to complete the cavity preparation with each system was also evaluated.Material and methods. Thermocouples were positioned in the pulp chamber of 20 extracted human third molars. Slot-type cavities (3 x 3 x 2 mm) were prepared on the buccal and the lingual surfaces of each tooth. The test groups were: high-speed cavity preparation with diamond rotary cutting instruments (n = 20) and ultrasonic cavity preparation with CVD points (n = 20). During cavity preparation, the increases In pulpal temperature, and the time required for the preparation, were recorded and analyzed by Student's t test for paired samples (alpha = .05).Results. The average pulpal temperature increases were 4.3 degrees C for the high-speed preparation and 3.8 degrees C for the ultrasonic preparation, which were statistically similar (P = .052). However, significant differences were found (P < .001) for the time expended (3.3 minutes for the high-speed bur and 13.77 minutes for the ultrasound device).Conclusions. The intrapulpal temperatures produced during cavity preparation by ultrasonic tips versus high-speed bur preparation were similar. However, the use of the ultrasonic device required 4 times longer for the completion of a cavity preparation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We present a measurement of the top quark pair production cross section in p (p) over bar collisions at root s=1.96 TeV utilizing 425 pb(-1) of data collected with the D0 detector at the Fermilab Tevatron Collider. We consider the final state of the top quark pair containing one high-p(T) electron or muon and at least four jets. We exploit specific kinematic features of t (t) over bar events to extract the cross section. For a top quark mass of 175 GeV, we measure sigma(t (t) over bar)=6.4(-1.2)(+1.3)(stat)+/- 0.7(syst)+/- 0.4(lum) pb, in good agreement with the standard model prediction.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We present a measurement of the top quark mass with the matrix element method in the lepton+jets final state. As the energy scale for calorimeter jets represents the dominant source of systematic uncertainty, the matrix element likelihood is extended by an additional parameter, which is defined as a global multiplicative factor applied to the standard energy scale. The top quark mass is obtained from a fit that yields the combined statistical and systematic jet energy scale uncertainty. Using a data set of 0.4 fb(-1) taken with the D0 experiment at Run II of the Fermilab Tevatron Collider, the mass of the top quark is measured using topological information to be: m(top)(center dot+jets)(topo)=169.2(-7.4)(+5.0)(stat+JES)(-1.4)(+1.5)(syst) GeV, and when information about identified b jets is included: m(top)(center dot+jets)(b-tag)=170.3(-4.5)(+4.1)(stat+ JES)(-1.8)(+1.2)(syst) GeV. The measurements yield a jet energy scale consistent with the reference scale.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)