979 resultados para heating


Relevância:

20.00% 20.00%

Publicador:

Resumo:

With the building sector accounting for around 40% of the total energy consumption in the EU, energy efficiency in buildings is and continues to be an important issue. Great progress has been made in reducing the energy consumption in new buildings, but the large stock of existing buildings with poor energy performance is probably an even more crucial area of focus. This thesis deals with energy efficiency measures that can be suitable for renovation of existing houses, particularly low-temperature heating systems and ventilation systems with heat recovery. The energy performance, environmental impact and costs are evaluated for a range of system combinations, for small and large houses with various heating demands and for different climates in Europe. The results were derived through simulation with energy calculation tools. Low-temperature heating and air heat recovery were both found to be promising with regard to increasing energy efficiency in European houses. These solutions proved particularly effective in Northern Europe as low-temperature heating and air heat recovery have a greater impact in cold climates and on houses with high heating demands. The performance of heat pumps, both with outdoor air and exhaust air, was seen to improve with low-temperature heating. The choice between an exhaust air heat pump and a ventilation system with heat recovery is likely to depend on case specific conditions, but both choices are more cost-effective and have a lower environmental impact than systems without heat recovery. The advantage of the heat pump is that it can be used all year round, given that it produces DHW. Economic and environmental aspects of energy efficiency measures do not always harmonize. On the one hand, lower costs can sometimes mean larger environmental impact; on the other hand there can be divergence between different environmental aspects. This makes it difficult to define financial subsidies to promote energy efficiency measures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Exploiting solar energy technology for both heating and cooling purposes has the potential of meeting an appreciable portion of the energy demand in buildings throughout the year. By developing an integrated, multi-purpose solar energy system, that can operate all twelve months of the year, a high utilisation factor can be achieved which translates to more economical systems. However, there are still some techno-economic barriers to the general commercialisation and market penetration of such technologies. These are associated with high system and installation costs, significant system complexity, and lack of knowledge of system implementation and expected performance. A sorption heat pump module that can be integrated directly into a solar thermal collector has thus been developed in order to tackle the aforementioned market barriers. This has been designed for the development of cost-effective pre-engineered solar energy system kits that can provide both heating and cooling. This thesis summarises the characterisation studies of the operation of individual sorption modules, sorption module integrated solar collectors and a full solar heating and cooling system employing sorption module integrated collectors. Key performance indicators for the individual sorption modules showed cooling delivery for 6 hours at an average power of 40 W and a temperature lift of 21°C. Upon integration of the sorption modules into a solar collector, measured solar radiation energy to cooling energy conversion efficiencies (solar cooling COP) were between 0.10 and 0.25 with average cooling powers between 90 and 200 W/m2 collector aperture area. Further investigations of the sorption module integrated collectors implementation in a full solar heating and cooling system yielded electrical cooling COP ranging from 1.7 to 12.6 with an average of 10.6 for the test period. Additionally, simulations were performed to determine system energy and cost saving potential for various system sizes over a full year of operation for a 140 m2 single-family dwelling located in Madrid, Spain. Simulations yielded an annual solar fraction of 42% and potential cost savings of €386 per annum for a solar heating and cooling installation employing 20m2 of sorption integrated collectors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Emissions from residential combustion appliances vary significantly depending on the firing behaviours and combustion conditions, in addition to combustion technologies and fuel quality. Although wood pellet combustion in residential heating boilers is efficient, the combustion conditions during start-up and stop phases are not optimal and produce significantly high emissions such as carbon monoxide and hydrocarbon from incomplete combustion. The emissions from the start-up and stop phases of the pellet boilers are not fully taken into account in test methods for ecolabels which primarily focus on emissions during operation on full load and part load. The objective of the thesis is to investigate the emission characteristics during realistic operation of residential wood pellet boilers in order to identify when the major part of the annual emissions occur. Emissions from four residential wood pellet boilers were measured and characterized for three operating phases (start-up, steady and stop). Emissions from realistic operation of combined solar and wood pellet heating systems was continuously measured to investigate the influence of start-up and stop phases on total annual emissions. Measured emission data from the pellet devices were used to build an emission model to predict the annual emission factors from the dynamic operation of the heating system using the simulation software TRNSYS. Start-up emissions are found to vary with ignition type, supply of air and fuel, and time to complete the phase. Stop emissions are influenced by fan operation characteristics and the cleaning routine. Start-up and stop phases under realistic operation conditions contribute 80 – 95% of annual carbon monoxide (CO) emission, 60 – 90% total hydrocarbon (TOC), 10 – 20% of nitrogen oxides (NO), and 30 – 40% particles emissions. Annual emission factors from realistic operation of tested residential heating system with a top fed wood pelt boiler can be between 190 and 400 mg/MJ for the CO emissions, between 60 and 95 mg/MJ for the NO, between 6 and 25 mg/MJ for the TOC, between 30 and 116 mg/MJ for the particulate matter and between 2x10-13 /MJ and 4x10-13 /MJ for the number of particles. If the boiler has the cleaning sequence with compressed air such as in boiler B2, annual CO emission factor can be up to 550 mg/MJ. Average CO, TOC and particles emissions under realistic annual condition were greater than the limits values of two eco labels. These results highlight the importance of start-up and stop phases in annual emission factors (especially CO and TOC). Since a large or dominating part of the annual emissions in real operation arise from the start-up and stop sequences, test methods required by the ecolabels should take these emissions into account. In this way it will encourage the boiler manufacturers to minimize annual emissions. The annual emissions of residential pellet heating system can be reduced by optimizing the number of start-ups of the pellet boiler. It is possible to reduce up to 85% of the number of start-ups by optimizing the system design and its controller such as switching of the boiler pump after it stops, using two temperature sensors for boiler ON/OFF control, optimizing of the positions of the connections to the storage tank, increasing the mixing valve temperature in the boiler circuit and decreasing the pump flow rate. For 85 % reduction of start-ups, 75 % of CO and TOC emission factors were reduced while 13% increase in NO and 15 % increase in particle emissions was observed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

By coating textiles with electrically conductive organic polymers, we are able to produce functional, intelligent fabrics. These fabrics can be utilised in applications such as gas sensors, actuators, electromagnetic shielding, radar absorption, selected frequency filtering in indoor wireless applications, and heating applications where vital parts of the body can be heated without embedding any wiring through the fabric.

Heat generation in fabrics coated with the conductive polymer polypyrrole was investigated. The fabrics were coated by chemical synthesis methods by oxidizing the pyrrole monomer in the presence of the fabric substrate. Ferric chloride was selected as the oxidizing agent and anthraquinone-2-sulfonic acid (AQSA) sodium salt monohydrate as the dopant.

Conductive fabrics were characterized by resistivity measurements, scanning electron microscopy, thermal imaging, current transmission over a period of time and calculations of power density per unit area. Effects of reaction conditions on the electrical properties and heat generated are presented. Polypyrrole coated fabrics were stable and possessed high electrical conductivity. Resistivity values ranged from 100-500 ohms/square depending on the reaction parameters. When subjected to a constant voltage of 24V, the polypyrrole coated polyester-Lycra® fabric doped with AQSA reached a maximum temperature of 42°C and a power density per unit area of 430 W/m2 was achieved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The alternant heat transfer induced by particle packet and gas bubbles on an object surface in a gas fluidised bed is computationally studied. The particle packet and bubble are modelled by a DPPM (double particle-layer and Porous Medium) model and a hemispherical model, respectively. Different meshing schemes are applied and different mesh sizes are used in meshing particle packet and heated object and a very large geometrical size difference between them was considered. Two parallel solver processes were proposed to perform the simulation of heat transfer for different purposes and implemented with the Fluent CFD package.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The literature over the past 25 years indicates that there has been a continued interest in using passive and active solar technologies to reduce the conventional energy required to maintain water temperatures in small recirculation aquaculture systems. Although all of the experimental systems reviewed report favourable results, there is little information available to guide system designers. This paper describes the use of a simulation model to predict the annual conventional energy consumption of a 10.6 m3 RAS enclosed in a double layer polyethylene greenhouse in two different climates. The water was maintained at 22.5 °C and the recirculation rate was 10% of tank volume per day. Simple unglazed solar collectors have also been combined with the greenhouse to further reduce energy consumption. The effect of increasing collector area on the solar fraction and utilization of useful energy was predicted. Finally, the model was used to investigate the relationship between the occurrence of condensation on the inner cover, ventilation rates and energy use. It was found that in a hot dry climate, the greenhouse alone was sufficient to reduce the conventional energy requirements by 87%; while in the cooler temperate climate reductions of 66% were possible. When solar collectors were added to the system, conventional energy requirements were reduced further and depended on the area of collector used. For example, in the temperate climate location, conventional energy requirements were reduced to 23% of a RAS enclosed in a non-solar building when 26 m2 of solar collector inclined at the optimum angle for winter energy collection were used. Although condensation could be successfully reduced by ventilation of the greenhouse, this increased conventional energy requirements because the potential for evaporation was increased. Covering the tanks at night was found to be a more effective strategy because it reduced condensation and conventional energy use simultaneously.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Development of civil aerospace composites is key to future “greener” aircraft. Aircraft manufacturers must improve efficiency of their product and manufacturing processes to remain viable. The aerospace industry is undergoing a materials revolution in the design and manufacture of composite airframes. The Airbus A350 and Boeing 787 (both due to enter service in the latter part of this decade) will push utilisation levels of  composite materials beyond 50% of the total airframe by weight. This  change requires massive investment in materials technology, manufacturing capability and skills development. The Quickstep process provides the ability to rapidly cure aerospace standard composite materials whilst providing enhanced mechanical properties. Utilising fluid to transfer heat to the   composite component during the curing process allows far higher heat rates than with conventional cure techniques. The rapid heat-up rates reduce the viscosity of the resin system greatly to provide a longer processing window introducing greater flexibility and removing the need for high pressure during cure. Interlaminar fracture toughness (Mode I) and Interfacial Shear Strength of aerospace standard materials cured using Quickstep have been    compared to autoclave cured laminates. Results suggest an improvement in fibre-matrix adhesion.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Wildfires can induce or enhance soil water repellency under a range of vegetation communities. According to mainly USA-based laboratory studies, repellency is eliminated at a maximum soil temperature (T) of 280–400°C. Knowledge of T reached during a wildfire is important in evaluating post-fire soil physical properties, fertility and seedbed status. T is, however, notoriously difficult to ascertain retrospectively and often based on indicative observations with a large potential error. Soils under fire-prone Australian eucalypt forests tend to be water repellent when dry or moderately moist even if long unburnt. This study aims to quantify the temperature of water repellency destruction for Australian topsoil material sampled under three sites with contrasting eucalypt cover (Eucalyptus sieberi, E. ovata and E. baxteri). Soil water repellency was present prior to heating in all samples, increased during heating, but was abruptly eliminated at a specific T between 260 and 340°C. Elimination temperature varied somewhat between samples, but was found to be dependent on heating duration, with longest duration resulting in lowest elimination temperature. Results suggest that post-fire water repellency may be used as an aid in hindcasting soil temperature reached during the passage of a fire within repellency-prone environments.


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Polyethyleneterephtalate–polypyrrole (PET–PPy) textile complexes incorporating different anionic dopants have been heat treated at 60 °C, 80 °C, 105 °C, 125 °C and 150 °C to investigate effects of short-term heating on conductivity and stability. In most cases heat treatments below 80 °C did not significantly change the final resistance of the conducting textiles. Only the anionic dye-dopant Indigo Carmine acted in a heat-stabilizing manner during treatment at 150 °C, while all samples containing other anionic dopant underwent some degradation. A treatment temperature of 125 °C was the most effective for lowering the final resistance, with sulphonic group containing dopants being particularly effective in improving conductivity and stability. A 29% decrease in the final resistance of a PET–PPy/para-toluene-2-sulphonic acid (pTSA) sample was achievable after 900 s at 125 °C.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The effect of heating rate on the cure behaviour and phase separation of thermoplastic-modified epoxy systems was investigated. Polyethersulphone (PES) modified multifunctional epoxies, triglycidyl-aminophenol (TGAP) and tetraglycidyldiaminodiphenylmethane (TGDDM), as well T300/914 prepreg were used. It was shown that heating rate had a significant influence on the cure kinetics and phase structures of investigated systems. Greater heating rate causes higher epoxy conversion. The domain size of the macrophases formed from phase separation increases with the increase of heating rate. A more complete phase separation is achieved by fast heated thermoplastic-modified epoxy blends.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The bond strength of various metal multilayers produced by cold rolling of metal foils with different thermal conductivity was investigated. Results indicated that the metallic multilayer system with low thermal conductivity exhibited relative high bond strength while high thermal conductivity metal system may fail to be roll-bonded together. The relationship between the deformation-induced localized heating and the bond strength were discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Greenhouse heating costs for some commercial growers in southern Australia are now a significant production cost. This is particularly the case for those operators who installed heating systems using liquefied petroleum gas (LPG) when this fuel was relatively inexpensive. Heat pump systems used in various configurations have been suggested as an option for reducing energy use and costs for greenhouse heating, particularly if off-peak electricity is used. This paper investigates the financial and environmental viability of an air-to-water heat pump system for a 4000 m2 greenhouse, located 120 km north of Melbourne, Victoria. The simulation software, TRNSYS, was used to predict the performance of the system. The heat pump system was found to have a simple payback period of approximately six years and reduce LPG consumption by 16%. Greenhouse gas emissions were 3% higher using the heat pump system, compared to the existing LPG boiler.