977 resultados para goodwill impairment test


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background To determine whether changes in appetite and energy intake (EI) can be detected and play a role in the effectiveness of interventions, it is necessary to identify their variability under normal conditions. We assessed the reproducibility of subjective appetite ratings and ad libitum test meal EI after a standardised pre-load in overweight and obese males. Methods Fifteen overweight and obese males (BMI 30.3 ± 4.9 kg/m2, aged 34.9 ± 10.6 years) completed two identical test days, 7 days apart. Participants were provided with a standardised fixed breakfast (1676 kJ) and 5 h later an ad libitum pasta lunch. An electronic appetite rating system was used to assess subjective ratings before and after the fixed breakfast, and periodically during the postprandial period. EI was assessed at the ad libitum lunch meal. Sample size estimates for paired design studies were calculated. Results Appetite ratings demonstrated a consistent oscillating pattern between test days, and were more reproducible for mean postprandial than fasting ratings. The correlation between ad libitum EI on the two test days was r = 0.78 (P < 0.01). Using a paired design and a power of 0.8, a minimum of 12 participants would be needed to detect a 10 mm change in 5 h postprandial mean ratings and 17 to detect a 500 kJ difference in ad libitum EI. Conclusion Intra-individual variability of appetite and ad libitum test meal EI in overweight and obese males is comparable to previous reports in normal weight adults. Sample size requirements for studies vary depending on the parameter of interest and sensitivity needed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

There is an increasing desire and emphasis to integrate assessment tools into the everyday training environment of athletes. These tools are intended to fine-tune athlete development, enhance performance and aid in the development of individualised programmes for athletes. The areas of workload monitoring, skill development and injury assessment are expected to benefit from such tools. This paper describes the development of an instrumented leg press and its application to testing leg dominance with a cohort of athletes. The developed instrumented leg press is a 45° reclining sled-type leg press with dual force plates, a displacement sensor and a CCD camera. A custom software client was developed using C#. The software client enabled near-real-time display of forces beneath each limb together with displacement of the quad track roller system and video feedback of the exercise. In recording mode, the collection of athlete particulars is prompted at the start of the exercise, and pre-set thresholds are used subsequently to separate the data into epochs from each exercise repetition. The leg press was evaluated in a controlled study of a cohort of physically active adults who performed a series of leg press exercises. The leg press exercises were undertaken at a set cadence with nominal applied loads of 50%, 100% and 150% of body weight without feedback. A significant asymmetry in loading of the limbs was observed in healthy adults during both the eccentric and concentric phases of the leg press exercise (P < .05). Mean forces were significantly higher beneath the non-dominant limb (4–10%) and during the concentric phase of the muscle action (5%). Given that symmetrical loading is often emphasized during strength training and remains a common goal in sports rehabilitation, these findings highlight the clinical potential for this instrumented leg press system to monitor symmetry in lower-limb loading during progressive strength training and sports rehabilitation protocols.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose We designed a visual field test focused on the field utilized while driving to examine associations between field impairment and motor vehicle collision involvement in 2,000 drivers ≥70 years old. Methods The "driving visual field test" involved measuring light sensitivity for 20 targets in each eye, extending 15° superiorly, 30° inferiorly, 60° temporally and 30° nasally. The target locations were selected on the basis that they fell within the field region utilized when viewing through the windshield of a vehicle or viewing the dashboard while driving. Monocular fields were combined into a binocular field based on the more sensitive point from each eye. Severe impairment in the overall field or a region was defined as average sensitivity in the lowest quartile of sensitivity. At-fault collision involvement for five years prior to enrollment was obtained from state records. Poisson regression was used to calculate crude and adjusted rate ratios examining the association between field impairment and at-fault collision involvement. Results Drivers with severe binocular field impairment in the overall driving visual field had a 40% increased rate of at-fault collision involvement (RR 1.40, 95%CI 1.07-1.83). Impairment in the lower and left fields was associated with elevated collision rates (RR 1.40 95%CI 1.07-1.82 and RR 1.49, 95%CI 1.15-1.92, respectively), whereas impairment in the upper and right field regions was not. Conclusions Results suggest that older drivers with severe impairment in the lower or left region of the driving visual field are more likely to have a history of at-fault collision involvement.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The ambiguity acceptance test is an important quality control procedure in high precision GNSS data processing. Although the ambiguity acceptance test methods have been extensively investigated, its threshold determine method is still not well understood. Currently, the threshold is determined with the empirical approach or the fixed failure rate (FF-) approach. The empirical approach is simple but lacking in theoretical basis, while the FF-approach is theoretical rigorous but computationally demanding. Hence, the key of the threshold determination problem is how to efficiently determine the threshold in a reasonable way. In this study, a new threshold determination method named threshold function method is proposed to reduce the complexity of the FF-approach. The threshold function method simplifies the FF-approach by a modeling procedure and an approximation procedure. The modeling procedure uses a rational function model to describe the relationship between the FF-difference test threshold and the integer least-squares (ILS) success rate. The approximation procedure replaces the ILS success rate with the easy-to-calculate integer bootstrapping (IB) success rate. Corresponding modeling error and approximation error are analysed with simulation data to avoid nuisance biases and unrealistic stochastic model impact. The results indicate the proposed method can greatly simplify the FF-approach without introducing significant modeling error. The threshold function method makes the fixed failure rate threshold determination method feasible for real-time applications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

With the variety of PV inverter types and the number of transformerless PV inverters on the Australian market increasing, we revisit some of the issues associated with these topologies. A recent electric shock incident in Queensland (luckily without serious outcome) associated with a transformerless PV system, highlights the need for earthing PV array structures and PV module frames to prevent capacitive leakage currents causing electric shock. The presented test results of the relevant voltages associated with leakage currents of five transformerless PV inverters stress this requirement, which is currently being addressed by both the Clean Energy Council and Standards Australia. DC current injection tests were performed on the same five inverters and were used to develop preliminary recommendations for a more meaningful DC current test procedure for AS4777 Part 2. The test circuit, methodology and results are presented and discussed. A notable temperature dependency of DC current injections with three of the five inverters suggests that DC current injection should be tested at high and low internal inverter temperatures whereas the power dependency noted only for one inverter does not seem to justify recommendations for a (rather involved) standard test procedure at different power levels.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Postural instability is one of the major complications found in stroke survivors. Parameterising the functional reach test (FRT) could be useful in clinical practice and basic research. OBJECTIVES: To analyse the reliability, sensitivity, and specificity in the FRT parameterisation using inertial sensors for recording kinematic variables in patients who have suffered a stroke. DESIGN: Cross-sectional study. While performing FRT, two inertial sensors were placed on the patient's back (lumbar and trunk). PARTICIPANTS: Five subjects over 65 who suffer from a stroke. MEASUREMENTS: FRT measures, lumbosacral/thoracic maximum angular displacement, maximum time of lumbosacral/thoracic angular displacement, time return initial position, and total time. Speed and acceleration of the movements were calculated indirectly. RESULTS: FRT measure is  12.75±2.06 cm. Intrasubject reliability values range from 0.829 (time to return initial position (lumbar sensor)) to 0.891 (lumbosacral maximum angular displacement). Intersubject reliability values range from 0.821 (time to return initial position (lumbar sensor)) to 0.883 (lumbosacral maximum angular displacement). FRT's reliability was 0.987 (0.983-0.992) and 0.983 (0.979-0.989) intersubject and intrasubject, respectively. CONCLUSION: The main conclusion could be that the inertial sensors are a tool with excellent reliability and validity in the parameterization of the FRT in people who have had a stroke.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ambiguity validation as an important procedure of integer ambiguity resolution is to test the correctness of the fixed integer ambiguity of phase measurements before being used for positioning computation. Most existing investigations on ambiguity validation focus on test statistic. How to determine the threshold more reasonably is less understood, although it is one of the most important topics in ambiguity validation. Currently, there are two threshold determination methods in the ambiguity validation procedure: the empirical approach and the fixed failure rate (FF-) approach. The empirical approach is simple but lacks of theoretical basis. The fixed failure rate approach has a rigorous probability theory basis, but it employs a more complicated procedure. This paper focuses on how to determine the threshold easily and reasonably. Both FF-ratio test and FF-difference test are investigated in this research and the extensive simulation results show that the FF-difference test can achieve comparable or even better performance than the well-known FF-ratio test. Another benefit of adopting the FF-difference test is that its threshold can be expressed as a function of integer least-squares (ILS) success rate with specified failure rate tolerance. Thus, a new threshold determination method named threshold function for the FF-difference test is proposed. The threshold function method preserves the fixed failure rate characteristic and is also easy-to-apply. The performance of the threshold function is validated with simulated data. The validation results show that with the threshold function method, the impact of the modelling error on the failure rate is less than 0.08%. Overall, the threshold function for the FF-difference test is a very promising threshold validation method and it makes the FF-approach applicable for the real-time GNSS positioning applications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives To evaluate relationships between self-reported physical activity, proportions of long-chain omega-3 polyunsaturated fatty acids (LCn3) in erythrocyte content (percentage of total fatty acids) and risk of mild cognitive impairment (MCI) in older adults. Method A cross-sectional study was conducted. Community-dwelling male and female (n = 84) participants over the age of 65 years with and without MCI were tested for erythrocyte proportions of the LCn3s eicosapentaenoic acid (EPA) and docosahexaenoic acid (DHA). Physical activity was measured using a validated questionnaire. Results The interaction between erythrocyte EPA, but not DHA, and increased physical activity was associated with increased odds of a non-MCI classification. Conclusion An interaction between physical activity and erythrocyte EPA content (percentage of fatty acids) significantly predicted MCI status in older adults. Randomised control trials are needed to examine the potential for supplementation with EPA in combination with increased physical activity to mitigate the risk of MCI in ageing adults.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Automotive interactive technologies represent an exemplar challenge for user experience (UX) designers, as the concerns for aesthetics, functionality and usability add up to the compelling issues of safety and cognitive demand. This extended abstract presents a methodology for the user-centred creation and evaluation of novel in-car applications, involving real users in realistic use settings. As a case study, we present the methodologies of an ideation workshop in a simulated environment and the evaluation of six design idea prototypes for in-vehicle head up display (HUD) applications using a semi-naturalistic drive. Both methods rely on video recordings of real traffic situations that the users are familiar with and/or experienced themselves. The extended abstract presents experiences and results from the evaluation and reflection on our methods.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Many researchers in the field of civil structural health monitoring (SHM) have developed and tested their methods on simple to moderately complex laboratory structures such as beams, plates, frames, and trusses. Fieldwork has also been conducted by many researchers and practitioners on more complex operating bridges. Most laboratory structures do not adequately replicate the complexity of truss bridges. Informed by a brief review of the literature, this paper documents the design and proposed test plan of a structurally complex laboratory bridge model that has been specifically designed for the purpose of SHM research. Preliminary results have been presented in the companion paper.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives The objective of this study was to develop process quality indicators (PQIs) to support the improvement of care services for older people with cognitive impairment in emergency departments (ED). Methods A structured research approach was taken for the development of PQIs for the care of older people with cognitive impairment in EDs, including combining available evidence with expert opinion (phase 1), a field study (phase 2), and formal voting (phase 3). A systematic review of the literature identified ED processes targeting the specific care needs of older people with cognitive impairment. Existing relevant PQIs were also included. By integrating the scientific evidence and clinical expertise, new PQIs were drafted and, along with the existing PQIs, extensively discussed by an advisory panel. These indicators were field tested in eight hospitals using a cohort of older persons aged 70 years and older. After analysis of the field study data (indicator prevalence, variability across sites), in a second meeting, the advisory panel further defined the PQIs. The advisory panel formally voted for selection of those PQIs that were most appropriate for care evaluation. Results In addition to seven previously published PQIs relevant to the care of older persons, 15 new indicators were created. These 22 PQIs were then field tested. PQIs designed specifically for the older ED population with cognitive impairment were only scored for patients with identified cognitive impairment. Following formal voting, a total of 11 PQIs were included in the set. These PQIs targeted cognitive screening, delirium screening, delirium risk assessment, evaluation of acute change in mental status, delirium etiology, proxy notification, collateral history, involvement of a nominated support person, pain assessment, postdischarge follow-up, and ED length of stay. Conclusions This article presents a set of PQIs for the evaluation of the care for older people with cognitive impairment in EDs. The variation in indicator triggering across different ED sites suggests that there are opportunities for quality improvement in care for this vulnerable group. Applied PQIs will identify an emergency services' implementation of care strategies for cognitively impaired older ED patients. Awareness of the PQI triggers at an ED level enables implementation of targeted interventions to improve any suboptimal processes of care. Further validation and utility of the indicators in a wider population is now indicated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives The purpose of this study was to identify the structural quality of care domains and to establish a set of structural quality indicators (SQIs) for the assessment of care of older people with cognitive impairment in emergency departments (EDs). Methods A structured approach to SQI development was undertaken including: 1) a comprehensive search of peer-reviewed and gray literature focusing on identification of evidence-based interventions targeting structure of care of older patients with cognitive impairment and existing SQIs; 2) a consultative process engaging experts in the care of older people and epidemiologic methods (i.e., advisory panel) leading to development of a draft set of SQIs; 3) field testing of drafted SQIs in eight EDs, leading to refinement of the SQI set, and; 4) an independent voting process among the panelists for SQI inclusion in a final set, using preestablished inclusion and exclusion criteria. Results At the conclusion of the process, five SQIs targeting the management of older ED patients with cognitive impairment were developed: 1) the ED has a policy outlining the management of older people with cognitive impairment during the ED episode of care; 2) the ED has a policy outlining issues relevant to carers of older people with cognitive impairment, encompassing the need to include the (family) carer in the ED episode of care; 3) the ED has a policy outlining the assessment and management of behavioral symptoms, with specific reference to older people with cognitive impairment; 4) the ED has a policy outlining delirium prevention strategies, including the assessment of patients' delirium risk factors, and; 5) the ED has a policy outlining pain assessment and management for older people with cognitive impairment. Conclusions This article presents a set of SQIs for the evaluation of performance in caring for older people with cognitive impairment in EDs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background The Spine Functional Index (SFI) is a patient reported outcome measure with sound clinimetric properties and clinical viability for the determination of whole-spine impairment. To date, no validated Turkish version is available. The purpose of this study is to cross-culturally adapted the SFI for Turkish-speaking patients (SFI-Tk) and determine the psychometric properties of reliability, validity and factor structure in a Turkish population with spine musculoskeletal disorders. Methods The SFI English version was culturally adapted and translated into Turkish using a double forward and backward method according to established guidelines. Patients (n = 285, cervical = l29, lumbar = 151, cervical and lumbar region = 5, 73% female, age 45 ± 1) with spine musculoskeletal disorders completed the SFI-Tk at baseline and after a seven day period for test-retest reliability. For criterion validity the Turkish version of the Functional Rating Index (FRI) was used plus the Neck Disability Index (NDI) for cervical patients and the Oswestry Disability Index (ODI) for back patients. Additional psychometric properties were determined for internal consistency (Chronbach’s α), criterion validity and factor structure. Results There was a high degree of internal consistency (α = 0.85, item range 0.80-0.88) and test-retest reliability (r = 0.93, item range = 0.75-0.95). The factor analysis demonstrated a one-factor solution explaining 24.2% of total variance. Criterion validity with the ODI was high (r = 0.71, p < 0.001) while the FRI and NDI were fair (r = 0.52 and r = 0.58, respectively). The SFI-Tk showed no missing responses with the ‘half-mark’ option used in 11.75% of total responses by 77.9% of participants. Measurement error from SEM and MDC90 were respectively 2.96% and 7.12%. Conclusions The SFI-Tk demonstrated a one-factor solution and is a reliable and valid instrument. The SFI-Tk consists of simple and easily understood wording and may be used to assess spine region musculoskeletal disorders in Turkish speaking patients.