939 resultados para goldfish, colour-blind, motion detection, trainingsexperiments, random dot pattern
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The aim of this study was to evaluate the intraexaminer agreement in the detection of the mandibular canal roof (MCR) and mental foramen (MF) in panoramic radiographs. Forty panoramic radiographs of edentulous patients were used. Two calibrated examiners (A and B) read the images 2 times, for both sides independently, under blind conditions. The interval between the readings was 10 days. The intraexaminer agreement in the interpretation of MCR and MF was performed by kappa statistics with linear weighting (x). The intraexaminer agreement for the detection of MCR, in the left side, was good for both examiners (A: kappa = 0.67; B: kappa = 0.71). Related to the right side, it was found to be kappa = 0.47 and kappa = 0.62, respectively to A and B. The intraexaminer agreement for the detection of MF was good for both examiners interpreting the left side (A: kappa = 0.61; B: kappa = 0.63), and in relation to the right side, it was moderate (A: kappa = 0.51) and fair (B: kappa = 0.38). The intraexaminer agreement in the detection of MCR was good and from good to fair in the detection of MF.
Resumo:
Electrical conductivity and H-1 Nuclear Magnetic Resonance (NMR) techniques were used to investigate the ion-exchanged layered lead-niobate perovskite HPb2Nb3O10. nH(2)O, over the temperature range 90-350 K. Compounds were synthesized by the sol-gel method and calcinated at 650 degreesC. Analysis of the NMR data gives activation energies for the proton motion in the range 0.14-0.40 eV, which are dependent on the water content. The frequency and temperature dependencies of the proton spin-lattice relaxation times show that the character of the motion of the: water molecules is essentially two-dimensional, reflecting the layered structure of the material. The H-1 line-narrowing transition and the single spin-lattice relaxation rate maximum, observed in the hydrated compounds, are consistent with a Grotthuss-like mechanism for the proton diffusion. (C) 2000 Elsevier B.V. B.V. All rights reserved.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Objectives: To evaluate the accuracy of three different cutoff points for the detection of high blood pressure in adolescents, given the strong relationship between overweight and high blood pressure levels.Methods: A total of 1,021 adolescents of both sexes were enrolled in the study, selected at random from public and private schools in Londrina, Brazil. Their body weight was measured using a digital balance, and their height with a portable stadiometer with a maximum extension of 2 meters. Arterial blood pressure was measured using an automatic apparatus. The capacity of body mass index to detect high blood pressure was gauged using ROC curves and their parameters (sensitivity, specificity, and area under the curve).Results: The cutoff points proposed in a Brazilian standard exhibited greater accuracy (males: 0.636 +/- 0.038; females: 0.585 +/- 0.043) than the cutoff points proposed in an international (males: 0.594 +/- 0.040; females: 0.570 +/- 0.044) and a North-American standard (males: 0.612 +/- 0.039; females: 0.578 +/- 0.044).Conclusions: The Brazilian proposal offered greatest accuracy for indicating high blood pressure levels.
Resumo:
O vírus A da videira (Grapevine virus A, GVA) e o vírus B da videira (Grapevirus virus B, GVB) estão associados à acanaladura do lenho de Kober (Kober stem grooving) e ao fendilhamento cortical da videira (grapevine corky bark), respectivamente. Este trabalho descreve o uso de sondas moleculares de cDNA na detecção de isolados do GVA (GVA-SP) e do GVB (GVB-C-SP e GVB-I-SP) em videiras (Vitis spp.) e fumo (Nicotiana occidentalis). As sondas marcadas com digoxigenina foram produzidas por RT-PCR utilizando oligonucleotídeos específicos para os genes da proteína capsidial. Os RNA totais foram extraídos de 45 plantas de diversas variedades de videira e de 13 plantas de fumo inoculadas mecanicamente com o GVB. Os RNA extraídos das plantas infetadas, indexadas biologicamente, hibridizaram com as sondas, não se verificando reação com plantas sadias. Para confirmar os resultados de hibridização, foram também feitos testes de RT-PCR. A utilização de hibridização dot-blot com sondas de cDNA mostrou-se eficaz na detecção dos vírus com especificidade e sensibilidade, ressaltando-se que, preferencialmente, folhas maduras e ramos dormentes devem ser utilizados nos testes diagnósticos para o GVB e GVA, respectivamente.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
We present a non-radioactive alternative to Southern's (J. Mol. Biol. 98: 503-517, 1975) DNA-DNA hybridization technique. The use of AMPPD - Disodium 3-(4-Methoxyspiro {1,2-dioxetane-3,2'tricyclo[3.3.1.1(3,7)]decan}-4-yl)phyenyl phosphate as an alternative substrate for AP-mediated detection of digoxigenin-11 dUTP-labeled probes made possible the simple and nonhazardous reuse of blots. We used 0.8 % agarose gels containing 30 mug per lane of Eucalyptus saligna DNA, digested with Eco RI, electrophoresed and blotted on to nylon membranes (Hybond-N, Amersham, UK), using the Southern blotting procedure, and UV irradiated for one minute for DNA fixation. The hybridizations were carried out overnight with digoxigenin labeled random inserts of E. saligna DNA by using the Genius Kit (Boehringer Mannheim). Detection of the DNA-DNA hybrids was performed in the presence of 0.5% blocking agent and the substrates NBT/BCIP were replaced by 0.26 mM AMPPD in the final alkaline assay buffer (50 mul/cm2). After membrane incubation for five minutes at room temperature in a sealed plastic bag, the AMPPD solution was retrieved and stored at 4-degrees-C for reuse. A Kodak X-BRAF QA-S film was pressed firmly onto the bag containing the wet membrane, exposed for two to six hours and then developed. After use, the probes were stripped off and the blots reutilized, three times so far, with the same results.
Resumo:
A new concept of fault detection and isolation using robust observation for systems with random noises is presented. The method selects the parameters from components that may fault during the process and constructs well conditioned robust observers, considering sensors faults. To isolate component failures via robust observation, a bank of detection observers is constructed, where each observer is only sensitive to one specified component failure while robust to all other component failures.
Resumo:
This work presents an electroanalytical method based on square-wave voltammetry (SWV) for the determination of quinizarine (QNZ) in a mixture of Britton-Robinson buffer 0.08 mol L-1 with 30% of acetonitrile. The QNZ was oxidized at glassy carbon electrode in and the well-defined peak at +0.45 V vs. Ag/AgCl can be used for its determination as colour marker in fuel samples. All parameters were optimized and analytical curves can be constructed for QNZ concentrations ranging from 2.0 x 10(-6) mol L-1 to 1.4 x 10(-5) mol L-1, using f = 60 Hz and E-sw = 25 mV. The method offers a limit detection of 4.12 x 10(-7) mol L-1 and a standard deviation of 4.5% when six measurements of 1.25 x 10(-5) mol L-1 are compared. The method was successfully applied for determining QNZ in gasoline and diesel oil and the obtained results showed good agreement with those reported previously. (c) 2006 Elsevier Ltd. All rights reserved.
Resumo:
A new concept of fault detection and isolation using robust observation for systems with random noises is presented. The method selects the parameters from components that may fault during the process and constructs well conditioned robust observers, considering sensors faults. To isolate component failures via robust observation, a bank of detection observers is constructed, where each observer is only sensitive to one specified component failure while robust to all other component failures.
Resumo:
This study aimed to evaluate the effectiveness of low intensity laser therapy (LILT) in 30 patients presenting temporomandibular joint (TMJ) pain and mandibular dysfunction in a random and double-blind research design. The sample, divided into experimental group (1) and placebo group (2), was submitted to the treatment with infrared laser (780 nm, 30 mW, 10 s, 6.3 J/cm2) at three TMJ points. The treatment was evaluated throughout six sessions and 15, 30 and 60 days after the end of the therapy, through visual analogue scale (VAS), range of mandibular movements and TMJ pressure pain threshold. The results showed a reduction in VAS (p < 0.001) and through the ANOVA with repeated measures it was observed that the groups did not present statistically significant differences (P = 0.2060), as the averages of the evaluation times (P = 0.3955) and the interaction groups evaluation times (P = 0.3024), considering the MVO. The same occurred for RLE (P = 0.2988, P = 0.1762 and P = 0.7970), LLE (P = 0.3265, P = 0.4143 and P = 0.0696), PPTD (P = 0.1558, P = 0.4695 and P = 0.0737) and PPTE (P = 0.2376, P = 0.3203 and P = 0.0624). For PE, there were not statistically significant differences for groups (P = 0.7017) and the interaction groups evaluation times (P = 0.6678), even so in both groups the PE varied with time (P = 0.0069). © 2005 Blackwell Publishing Ltd.
Resumo:
Indirect ELISA and IFAT have been reported to be more sensitive and specific than agglutination tests. However, MAT is cheaper, easier than the others and does not need special equipment. The purpose of this study was to compare an enzyme linked immunosorbent assay using crude rhoptries of Toxoplasma gondii as coating wells (r-ELISA) with indirect fluorescence antibody test (IFAT) and modified agglutination test (MAT) to detect anti-T. gondii antibodies in sera of experimentally infected pigs. Ten mixed breed pigs between 6.5 and 7.5 weeks old were used. All pigs were negative for the presence of T. gondii antibodies by IFAT (titre < 16), r-ELISA (OD < 0.295) and MAT (titre < 16). Animals received 7 × 107 viable tachyzoites of the RH strain by intramuscular (IM) route at day 0. Serum samples were collected at days -6, 0, 7, 14, 21, 28, 35, 42, 50, and 57. IFAT detected anti-T. gondii antibodies earlier than r-ELISA and MAT. The average of antibody levels was higher at day 35 in IFAT (Log10 = 2.9) and in MAT (Log10 = 3.5), and at day 42 in r-ELISA (OD = 0.797). The antibody levels remained high through the 57th day after inoculation in MAT, and there was a decrease tendency in r-ELISA and IFAT. IFAT was used as gold standard and r-ELISA demonstrated a higher prevalence (73.3%), sensitivity (94.3%), negative predictive value (83.3%), and accuracy (95.6%) than MAT. Kappa agreements among tests were calculated, and the best results were shown by r-ELISA × IFAT (κ = 0.88, p < 0.001). Cross-reaction with Sarcocystis miescheriana was investigated in r-ELISA and OD mean was 0.163 ± 0.035 (n = 65). Additionally, none of the animals inoculated with Sarcocystis reacted positively in r-ELISA. Our results indicate that r-ELISA could be a good method for serological detection of T. gondii infection in pigs. © 2005 Elsevier Inc. All rights reserved.
Resumo:
In the present study, we evaluated three techniques, mouse bioassay, histopathology, and polymerase chain reaction (PCR) to detect Toxoplasma gondii infection in tissues from experimentally infected pigs. Twelve mixed breed pigs, seronegative for T. gondii using an indirect immunofluorescent antibody test (IFAT), were used. Ten pigs were infected with 4 × 104 VEG strain oocysts, and two were maintained as uninfected controls. Animals were killed 60 days pos infection. Muscle (heart, tongue, diaphragm, and masseter) and brain samples were collected to investigate the presence of T. gondii tissue cysts by the different assay methods. For the bioassay, samples of brain (50 g) and pool of muscle samples (12.5 g of tongue, masseter, diaphragm, and heart) were used. PCR was performed using Tox4 and Tox5 primers which amplified a 529 bp fragment. The DNA extraction and PCR were performed three times, and all tissue samples were tested individually (brain, tongue, masseter, diaphragm, and heart). For histopathology, fragments of tissues were fixed in 10% of buffered formal saline and stained with HE. Histopathological results were all negative. PCR showed 25/150 (16.6%) positive samples, being 17/120 (14.1%) and 8/30 (26.6%) from muscle, and brain tissues, respectively. Tissue cysts of T. gondii were identified by mouse bioassay in 54/98 (55.1%) samples, being 31/48 (64.6%) from muscle samples, and 23/50 (46.0%) from brain samples. Toxoplasma gondii isolation in muscle samples by mouse bioassay was higher than in PCR (P < 0.01). Results indicate that DNA from pig tissues interfered with 529-bp-PCR sensitivity, and mouse bioassay was better than PCR in detecting T. gondii in tissues from pigs. © 2006 Elsevier Inc. All rights reserved.
Resumo:
DNA biosensors have gained increased attention over traditional diagnostic methods due to their fast and responsive operation and cost-effective design. The specificity of DNA biosensors relies on single-stranded oligonucleotide probes immobilized to a transduction platform. Here, we report the development of biosensors to detect the hippuricase gene (hipO) from Campylobacter jejuni using direct covalent coupling of thiol- and biotin-labeled single-stranded DNA (ssDNA) on both surface plasmon resonance (SPR) and diffraction optics technology (DOT, dotLab) transduction platforms. This is the first known report of the dotLab to detect targeted DNA. Application of 6-mercapto-1-hexanol as a spacer thiol for SPR gold surface created a self-assembled monolayer that removed unbound ssDNA and minimized non-specific detection. The detection limit of SPR sensors was shown to be 2.5 nM DNA while dotLab sensors demonstrated a slightly decreased detection limit of 5.0 nM (0.005 μM). It was possible to reuse the SPR sensor due to the negligible changes in sensor sensitivity (∼9.7 × 10 -7 ΔRU) and minimal damage to immobilized probes following use, whereas dotLab sensors could not be reused. Results indicated feasibility of optical biosensors for rapid and sensitive detection of the hipO gene of Campylobacter jejuni using specific ssDNA as a probe. © 2011 Elsevier B.V.