618 resultados para farmacología
Resumo:
Colors of special-effect coatings have strong dependence on illumination/viewing geometry and an appealing appearance. An open question is to ask about the minimum number of measurement geometries required to completely characterize their observed color shift. A recently published principal components analysis (PCA)-based procedure to estimate the color of special-effect coatings at any geometry from measurements at a reduced set of geometries was tested in this work by using the measurement geometries of commercial portable multiangle spectrophotometers X-Rite MA98, Datacolor FX10, and BYK-mac as reduced sets. The performance of the proposed PCA procedure for the color-shift estimation for these commercial geometries has been examined for 15 special-effect coatings. Our results suggest that for rendering the color appearance of 3D objects covered with special-effect coatings, the color accuracy obtained with this procedure may be sufficient. This is the case especially if geometries of X-Rite MA98 or Datacolor FX10 are used.
Resumo:
Lectures about the course module "Advanced techniques for the human eye study: ocular aberrometry".
Resumo:
La línea de actuación prioritaria, en la presente edición, que es la cuarta, de nuestra “Red para la colaboración con centros de secundaria para la formación experimental de alumnos de bachillerato”, sigue siendo el fomento del intercambio de experiencias en diferentes campos del conocimiento dirigidas al alumnado que cursa Bachillerato o estudios de Secundaria. En este marco, este curso hemos recibido en nuestros laboratorios, para la realización de diferentes prácticas, en las que los alumnos han sido los verdaderos protagonistas, a 14 centros de la provincia de Alicante, en los meses de Enero y Febrero, durante el periodo de exámenes de los alumnos de grado. En total han sido 265 alumnos los que han realizado bajo nuestra supervisión las prácticas de laboratorio que previamente habían sido ofertadas en esta edición a los centros. Como en anteriores ediciones, los resultados obtenidos han sido plenamente satisfactorios tanto para los alumnos como para todos los profesores integrantes de la Red.
Resumo:
En el marco del EEES el sistema de evaluación debe valorar las competencias adquiridas por el estudiante en una determinada materia, según los conocimientos, las habilidades y las aptitudes que ha desarrollado a lo largo del proceso de enseñanza-aprendizaje. Además de las pruebas escritas diseñadas para evaluar los conocimientos y las capacidades de razonamiento, las distintas actividades de las nuevas asignaturas, como seminarios, prácticas de ordenador y de laboratorio o tutorías, se deben valorar con distintos modelos evaluadores, que dependerán a su vez de la metodología docente empleada. El objetivo de este estudio fue revisar los métodos de evaluación empleados en diversas asignaturas del Grado en Nutrición Humana y Dietética y del Grado en Óptica y Optometría de la Universidad de Alicante y analizar su contribución en los resultados globales de las asignaturas. Se han tenido en cuenta los diversos métodos de evaluación de las actividades así como las distintas formas de aplicar la evaluación continua y su influencia cualitativa en la calificación global.
Resumo:
Objetivo: Evaluar la eficacia del tratamiento en 3 casos de exotropia intermitente (XT(i)) mediante ejercicios de terapia visual, completando la exploración clínica con Videooculografia-30 y evidenciar la potencial aplicabilidad de esta tecnología para dicho propósito. Métodos: Exponemos los cambios ocurridos tras ejercicios de terapia visual en una mujer de 36 años con XT(i) de -25 dioptrías prismáticas (dp) de lejos y 18 dp de cerca; Un niño de 10 años de edad con 8 dp de XT(i) en posición primaria, asociados a +6 dp de hipotropia izquierda; y un hombre de 63 años con XT(i) de 6 dp en posición primaria asociada a +7 dp de hipertropia derecha. Todos los pacientes presentaron buena agudeza visual corregida en ambos ojos. La inestabilidad de la desviación ocular se evidenció mediante análisis de VOG-30, revelando la presencia de components verticales y torsionales. Se realizaron ejercicios de terapia visual, incluyendo diferentes tipos de ejercicios de vergencias, acomodación y percepción de la diplopía. Resultados: Tras la terapia visual se obtuvieron excelentes rangos de vergencias fusionales y de punto próximo de convergencia («hasta la nariz»). El examen mediante VOG-3D (Sensoro Motoric lnstruments, Teltow, Germany) confirmó la compensación de la desviación con estabilidad del alineamiento ocular. Se observó una significativa mejora después de la terapia en los components verticals y torsionales, lo cuales se hicieron más estables. Los pacientes se mostraron muy satisfechos de los resultados obtenidos. Conclusión: La VOG-3D es una técnica útil para dotamos de un método objetivo de registro de la compensación y estabilidad de la desviación ocular después de realizar ejercicios de terapia visual en casos de XT(i), ofreciéndonos un detallado análisis de la mejoría de los components verticales y torsionales.
Resumo:
Los títulos de Formación Profesional (FP) de Grado Superior permiten el acceso a estudios universitarios; de hecho, es frecuente encontrar estudiantes que se matriculan en FP con este propósito. Para finalizar el Ciclo Formativo el último módulo que han de superar es el de Formación en Centros de Trabajo (FCT) en el que ponen en práctica los conocimientos adquiridos en las clases teóricas. Estas prácticas, además de mejorar sus capacidades profesionales, también suponen su primera inserción en el mundo laboral. Este contacto con la realidad les puede hacer cambiar su vocación inicial, reformulando su proyecto de futuro. En este estudio se lanzó una encuesta a nivel nacional a profesores y alumnos de FP para identificar y cuantificar el perfil de los estudiantes que cambian de idea, analizando qué les ha llevado a modificar su planteamiento inicial. Los resultados –aun provisionales- muestran que a lo largo de las prácticas, (1) aumenta el número de estudiantes que deciden continuar sus estudios en la Universidad y (2) uno de cada cinco cambia de preferencia sobre qué titulación le gustaría cursar.
Resumo:
Actualmente la medida y gestión de la calidad de color de materiales gonio-aparentes es compleja, pero altamente demandada desde varios sectores industriales, como automoción, cosmética, etc. Desde la Universidad de Alicante, para el curso 2013-14, se va a organizar el primer postgrado (título de Máster) en Tecnología del Color para el Sector Automoción, con un diseño de contenidos que cubre la colorimetría CIE y la percepción visual, instrumentación y software de gestión del color, fundamentos de pinturas y plásticos, y, formulación de pigmentos, con una pretensión clara de cubrir las competencias demandadas por el sector a nivel mundial. El plan de estudios, con 60 ECTS, está diseñado para impartirse en solamente dos semestres: de septiembre a febrero para las actividades teóricas y prácticas semi-presenciales, y, desde marzo a junio las estancias en empresas e instituciones colaboradoras, tanto nacionales como internacionales, para realizar prácticas en empresa (máximo 300 horas), y con ello elaborar, exponer y defender el trabajo fin de máster. De esta forma, al finalizar la primera promoción de este máster propio de alta especialización profesional, esperamos aportar mayores vías de empleabilidad laboral a unos postgraduados en un sector industrial de gran importancia socioeconómica a nivel mundial.
Resumo:
Day of Chemistry, Invited conference, San Alberto Magno 2014
Resumo:
Background: The pupillary light reflex characterizes the direct and consensual response of the eye to the perceived brightness of a stimulus. It has been used as indicator of both neurological and optic nerve pathologies. As with other eye reflexes, this reflex constitutes an almost instantaneous movement and is linked to activation of the same midbrain area. The latency of the pupillary light reflex is around 200 ms, although the literature also indicates that the fastest eye reflexes last 20 ms. Therefore, a system with sufficiently high spatial and temporal resolutions is required for accurate assessment. In this study, we analyzed the pupillary light reflex to determine whether any small discrepancy exists between the direct and consensual responses, and to ascertain whether any other eye reflex occurs before the pupillary light reflex. Methods: We constructed a binocular video-oculography system two high-speed cameras that simultaneously focused on both eyes. This was then employed to assess the direct and consensual responses of each eye using our own algorithm based on Circular Hough Transform to detect and track the pupil. Time parameters describing the pupillary light reflex were obtained from the radius time-variation. Eight healthy subjects (4 women, 4 men, aged 24–45) participated in this experiment. Results: Our system, which has a resolution of 15 microns and 4 ms, obtained time parameters describing the pupillary light reflex that were similar to those reported in previous studies, with no significant differences between direct and consensual reflexes. Moreover, it revealed an incomplete reflex blink and an upward eye movement at around 100 ms that may correspond to Bell’s phenomenon. Conclusions: Direct and consensual pupillary responses do not any significant temporal differences. The system and method described here could prove useful for further assessment of pupillary and blink reflexes. The resolution obtained revealed the existence reported here of an early incomplete blink and an upward eye movement.
Resumo:
Purpose. To evaluate the usefulness of microperimetry in the early detection of the ocular anomalies associated with the use of hydroxychloroquine. Methods. Prospective comparative case series study comprising 14 healthy eyes of 7 patients (group A) and 14 eyes of 7 patients under treatment with hydroxychloroquine for the treatment of rheumatologic diseases and without fundoscopic or perimetric anomalies (group B). A comprehensive ophthalmological examination including microperimetry (MP) and spectraldomain optical coherence tomography was performed in both groups. Results. No significant differences were found in mean MP foveal sensitivity between groups (P = 0.18). However, mean MP overall sensitivity was significantly higher in group A (29.05 ± 0.57 dB versus group B, 26.05 ± 2.75 dB; P < 0.001). Significantly higher sensitivity values were obtained in group A in comparison to group B for the three eccentric loci evaluated (P < 0.001). Conclusion. Microperimetry seems to be a useful tool for the early detection of retinal damage in patients treated with hydroxychloroquine.
Resumo:
The mechanical response of the cornea subjected to a non-contact air-jet tonometry diagnostic test represents an interplay between its geometry, the corneal material behavior and the loading. The objective is to study this interplay to better understand and interpret the results obtained with a non-contact tonometry test. A patient-specific finite element model of a healthy eye, accounting for the load free configuration, was used. The corneal tissue was modeled as an anisotropic hyperelastic material with two preferential directions. Three different sets of parameters within the human experimental range obtained from inflation tests were considered. The influence of the IOP was studied by considering four pressure levels (10–28 mmHg) whereas the influence of corneal thickness was studied by inducing a uniform variation (300–600 microns). A Computer Fluid Dynamics (CFD) air-jet simulation determined pressure loading exerted on the anterior corneal surface. The maximum apex displacement showed a linear variation with IOP for all materials examined. On the contrary, the maximum apex displacement followed a cubic relation with corneal thickness. In addition, a significant sensitivity of the apical displacement to the corneal stiffness was also obtained. Explanation to this behavior was found in the fact that the cornea experiences bending when subjected to an air-puff loading, causing the anterior surface to work in compression whereas the posterior surface works in tension. Hence, collagen fibers located at the anterior surface do not contribute to load bearing. Non-contact tonometry devices give useful information that could be misleading since the corneal deformation is the result of the interaction between the mechanical properties, IOP, and geometry. Therefore, a non-contact tonometry test is not sufficient to evaluate their individual contribution and a complete in-vivo characterization would require more than one test to independently determine the membrane and bending corneal behavior.
Resumo:
In this paper we present a novel image processing algorithm providing good preliminary capabilities for in vitro detection of malaria. The proposed concept is based upon analysis of the temporal variation of each pixel. Changes in dark pixels mean that inter cellular activity happened, indicating the presence of the malaria parasite inside the cell. Preliminary experimental results involving analysis of red blood cells being either healthy or infected with malaria parasites, validated the potential benefit of the proposed numerical approach.
Resumo:
La diferencia de alineación de los ejes visuales en la Disparidad de Fijación en la gran mayoría de situaciones se produce como un efecto fisiológico no produciendo sintomatología al paciente. Sin embargo, existen ciertas situaciones en las que la Disparidad de Fijación sí que produce sintomatología al paciente, produciéndose como consecuencia del estrés de los sistemas de vergencia y acomodativo con el objetivo de mantener la visión binocular. Existen además evidencias científicas de que determinados hábitos de lectura, patologías como las migrañas y pacientes disléxicos con problemas de lectura y de aprendizaje pueden observar un incremento significativo de la Disparidad de Fijación, estando asociados a Disparidades de Fijación anormales. Debido a la información que proporciona la medida de la Disparidad de Fijación resulta de especial interés la cuantificación de la misma en la práctica clínica, existiendo en la actualidad diferentes tests y dispositivos clínicos que se utilizan comúnmente para la medida de la Disparidad de Fijación, como la Curva de Vergencias Forzadas, el Disparómetro de Sheedy, la Unidad de Mallet y la Carta de Wesson entre otros.
Resumo:
We investigated the diffraction behavior of plasmonic Bessel beams propagating in metal-dielectric stratified materials and wire media. Our results reveal various regimes in which polarization singularities are selectively maintained. This polarization-pass effect can be controlled by appropriately setting the filling factor of the metallic inclusions and its internal periodic distribution. These results may have implications in the development of devices at the nanoscale level for manipulation of polarization and angular momentum of cylindrical vector beams.
Resumo:
For suitable illumination and observation conditions, sparkles may be observed in metallic coatings. The visibility of these sparkles depends critically on their intensity, and on the paint medium surrounding the metallic flakes. Based on previous perception studies from other disciplines, we derive equations for the threshold for sparkles to be visible. The resulting equations show how the visibility of sparkles varies with the luminosity and distance of the light source, the diameter of the metallic flakes, and the reflection properties of the paint medium. The predictions are confirmed by common observations on metallic sparkle. For example, under appropriate conditions even metallic flakes as small as 1 μm diameter may be visible as sparkle, whereas under intense spot light the finer grades of metallic coatings do not show sparkle. We show that in direct sunlight, dark coarse metallic coatings show sparkles that are brighter than the brightest stars and planets in the night sky. Finally, we give equations to predict the number of visually distinguishable flake intensities, depending on local conditions. These equations are confirmed by previous results. Several practical examples for applying the equations derived in this article are provided.