1000 resultados para espectrometria de massa com fonte de plasma indutivamente acoplado
Resumo:
The goal of this study was to evaluate the feasibility of direct introduction of clay slurries in an inductively coupled plasma optical emission spectrometer with axial view configuration. Calibration was performed using a certified reference material with a mean particle size of 13 µm (IPT-42) and the analytical curve was applied for quantification of two others reference materials (IPT-28 and IPT-32) and four samples. It was demonstrated that the analytical curve thus obtained was not completely suitable for IPT-28 and samples due to different mineralogical phases determined by X-ray diffraction. After considering this effect, it was possible for most elements to obtain results in agreement with certified values or with values obtained by a conventional technique at a 95% confidence level. It was demonstrated that the ICP-OES with axial view configuration did not present any incompatibility with the direct introduction of a complex inorganic suspension.
Resumo:
The most important features of the CE-ICP hyphenation, as well as its advantages and drawbacks as a tool for speciation are discussed. The fundamental principles of capillary electrophoresis and inductively coupled plasma mass spectrometry are also presented. Some applications involving different designs proposed in the literature to couple CE and ICP system for elemental speciation are reviewed.
Resumo:
An analytical method for the isolation based on matrix solid-phase dispersion technique and gas chromatographic determination of pesticides in cattle plasma is presented. It was fortified 0.25 g of plasma with pesticides and blended with 1 g each C18 and Na2SO4. The homogenized matter was transferred to a SPE cartridge, which contained 1 g of activated florisil with 5 mL acetonitrile. The analites were eluted under vaccum with 15 mL acetonitrile, the extract was analyzed by gas chromatography-mass spectrometry. The limit of quantification of the method was 0.04 mg L-1 for chlorphenvinfos and fipronil and 0.02 mg L-1 for cypermethrin..
Resumo:
Neste trabalho foram investigados diferentes métodos de preparação de amostra para a determinação de níquel e vanádio em óleo cru usando a espectrometria de absorção atômica com forno de grafite (GF AAS). Investigou-se o uso de xileno como diluente, o qual foi inadequado devido à baixa estabilidade de níquel nas soluções e resultando na contaminação do equipamento. As soluções diluídas em isobutilmetilcetona apresentaram melhor estabilidade, mas não houve reprodutibilidade das medidas com os padrões orgânicos de níquel. Melhores resultados foram obtidos com emulsões óleo-em-água, usando Triton X-100 como surfactante. Também foi estudado o uso de padrões aquosos (inorgânicos) para o preparo das emulsões. Após o estabelecimento de curvas de pirólise para padrão e amostra de óleo cru, observou-se diferença no comportamento térmico do níquel na matriz de óleo cru. Foi então realizada uma investigação usando um espectrômetro de absorção atômica com fonte contínua de alta resolução (HR-CS AAS), equipamento com elevada capacidade de correção de fundo, e constatou-se que cerca de 50 % do analito é perdido em temperaturas abaixo de 400 ºC, enquanto que o restante é termicamente estável até pelo menos 1200 ºC. A fim de resolver o problema de perda de níquel volátil, foi investigado o uso de paládio como modificador químico. Através de curvas de pirólise com e sem paládio, observou-se que a mesma perda também ocorreu para o vanádio. Após a otimização da melhor quantidade de paládio, verificou-se que foi necessária uma quantidade de 20 µg de paládio para estabilização de níquel e vanádio. A determinação de níquel e vanádio total em amostras de óleo cru foi realizada usando-se paládio como modificador químico. A especiação destes elementos foi possível através da determinação das espécies estáveis, provavelmente compostos salinos não porfirínicos de níquel e vanádio, sem a adição de paládio, e a fração de compostos voláteis (provavelmente porfirinas de níquel e vanádio) foi calculada por diferença. Estabeleceram-se as figuras de mérito obtendo-se valores de massa característica de 19 e 33 pg e limite de detecção de 43 e 113 pg para níquel e vanádio, respectivamente. Esses resultados são compatíveis com dados reportados na literatura. A exatidão deste procedimento foi verificada pela análise dos materiais de referência certificados de metais traço em óleo residual (SRM 1634c) para níquel e vanádio e o petróleo (RM 8505) somente para vanádio e também por comparação com os resultados obtidos por HR-CS AAS para várias amostras de óleo cru. A aplicação do teste estatístico t-student aos resultados de níquel e vanádio total obtidos por GF AAS e HR-CS AAS mostrou que os mesmos não são significativamente diferentes a um nível de 95% de confiança.
Resumo:
The pulsed plasma nitriding is a solution currently used in the metallurgical industry to resolve problems earlier in the processing of parts by using plasma DC voltage. These problems consisted mainly of edge effect and opening arches caused due to non-uniformity of electric fields on uneven surfaces. By varying the pulse width can reduce these effects. However, variations in pulse width can drastically affect the population of the plasma species and hence the final microstructure of the nitrided layer. In literature, little is known about the effect of process parameters on the properties of the plasma species and, consequently, the surface properties. We have developed a system of nitriding with pulsed source with fixed period of 800 pulse width is variable. Examined the variation of these parameters on the properties of nitrided surface when keeping constant temperature, gas composition, flow, pressure and power. It was found that the values of width and pulse repetition time of considerable influence in the intensities of the species present in plasma. Moreover, we observed the existence of the edge effect for some values of pulse widths, as well as changes in surface roughness and hardness
Resumo:
This work deals with the development of an experimental study on a power supply of high frequency that provides the toch plasmica to be implemented in PLASPETRO project, which consists of two static converters developed by using Insulated Gate Bipolar Transistor (IGBT). The drivers used to control these keys are triggered by Digital Signal Processor (DSP) through optical fibers to reduce problems with electromagnetic interference (EMI). The first stage consists of a pre-regulator in the form of an AC to DC converter with three-phase boost power factor correction which is the main theme of this work, while the second is the source of high frequency itself. A series-resonant inverter consists of four (4) cell inverters operating in a frequency around 115 kHz each one in soft switching mode, alternating itself to supply the load (plasma torch) an alternating current with a frequency of 450 kHz. The first stage has the function of providing the series-resonant inverter a DC voltage, with the value controlled from the power supply provided by the electrical system of the utility, and correct the power factor of the system as a whole. This level of DC bus voltage at the output of the first stage will be used to control the power transferred by the inverter to the load, and it may vary from 550 VDC to a maximum of 800 VDC. To control the voltage level of DC bus driver used a proportional integral (PI) controller and to achieve the unity power factor it was used two other proportional integral currents controllers. Computational simulations were performed to assist in sizing and forecasting performance. All the control and communications needed to stage supervisory were implemented on a DSP
Resumo:
The chemical recycling of polyolefins has been the focus of increasing attention owing potential application as a fuel and as source chemicals. The use of plastic waste contributes to the solution of pollution problems.The use of catalysts can enhance the thermal degradation of synthetic polymers, which may be avaliated by Themogravimetry (TG) and mass spectrometry (MS) combined techniques. This work aims to propose alternatives to the chemistry recycling of low-density polyethylene (LDPE) on mesoporous silica type SBA-15 and AlSBA-15.The mesoporous materials type SBA-15 and AlSBA-15 were synthesized through the hydrothermal method starting from TEOS, pseudobohemite, cloridric acid HCl and water. As structure template was used Pluronic P123. The syntheses were accomplished during the period of three days. The best calcination conditions for removal of the organic template (P123) were optimized by thermal analysis (TG/DTG) and through analyses of Xray diffraction (XRD), infrared spectroscopy (FT-IR), nitrogen adsorption and scanning electron microscopy (SEM) was verified that as much the hydrothermal synthesis method as the calcination by TG were promising for the production of mesoporous materials with high degree of hexagonal ordination. The general analysis of the method of Analog Scan was performed at 10oC/min to 500 oC to avoid deterioration of capillary with very high temperatures. Thus, with the results, we observed signs mass/charge more evident and, using the MID method, was obtained curve of evolution of these signals. The addition of catalysis produced a decrease in temperature of polymer degradation proportional to the acidity of the catalyst. The results showed that the mesoporous materials contributed to the formation of compounds of lower molecular weight and higher value in the process of catalytic degradation of LDPE, representing an alternative to chemical recycling of solid waste
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Pós-graduação em Química - IQ
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Diversas estratégias para preparo de amostra, determinação e fracionamento, tais como espectrometria de absorção atômica com atomização eletrotérmica em forno de grafite (GF AAS) e espectrometria de emissão óptica com plasma acoplado indutivamente com configuração axial (ICP OES), foram empregadas para o fracionamento de bário em Castanha-do-Pará. Esse alimento é amplamente apreciado tanto pelo valor nutricional, quanto pelo sabor agradável. A análise química de Castanha-do-Pará não é trivial devido à matriz complexa. O fracionamento de bário em Castanha-do-Pará foi estudado devido à toxicidade desse elemento e a correlação entre a forma química e a absorção. Os teores totais de bário nas amostras de Castanha-do-Pará variaram entre 860 e 2084 mg kg-1. Extrações sequenciais foram feitas com base na solubilidade em diferentes meios e composição química envolvendo lipídios, proteínas e compostos de baixa massa molecular (LMW). Teores mais elevados de bário foram determinados nas frações LMW e insolúvel em água que variaram entre 778-1606 e 551-1520 mg kg-1, respectivamente. Esses resultados indicaram a indisponibilidade de bário presente nesse alimento ao organismo humano. Baseando-se nos teores de bário e enxofre nas diferentes frações e em cálculos estequiométricos para as possíveis reações envolvidas pode-se inferir que bário se encontra principalmente na forma de BaSO4. Experimentos termogravimétricos também confirmaram essa suposição.
Resumo:
Pós-graduação em Química - IQ
Resumo:
O estresse oxidativo é um dos fatores mais importantes na diminuição da qualidade do sêmen, pois leva a perda da integridade da membrana dos espermatozóides e de danos estruturais ao DNA através da cascata de lipoperoxidação. Os danos funcionais relacionados ao estresse oxidativo como a diminuição da motilidade e da viabilidade do espermatozóide são algumas das principais causas de infertilidade masculina. Ainda, os lipídios que compõe a membrana plasmática são macromoléculas que, além de estarem envolvidas em complexos sistemas biológicos e processos metabólicos da célula, são altamente susceptíveis ao processo de lipoperoxidação desencadeado pelo estresse oxidativo. Neste contexto, este projeto propôs o estudo das alterações no perfil lipídico do plasma seminal que pudessem estar relacionadas ao estresse oxidativo e posterior comparação destes perfis em busca de biomarcadores de infertilidade. Para isso, foram coletadas amostras de sêmen de 116 pacientes que procuraram o setor de Reprodução Humana da Universidade Federal de São Paulo. Estas amostras foram submetidas a técnica de TBARS para quantificação dos produtos finais do estresse oxidativo e separação dos grupos, e em seguida, ao protocolo de extração de lipídios para obtenção dos espectros de massa através da técnica de MALDI (Matrix Assisted Laser Disorption Ionization). Com esta análise foi possível a identificação de 31 lipídeos super representados nos diferentes grupos e que, futuramente, poderão vir a ser utilizados na avaliação da qualidade seminal