409 resultados para elevator shaft


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The teaching and learning of mathematics through alternative methods make Mathematics more enjoyable, accessible and meaningful. Through teaching resource storytelling the student becomes the protagonist of the construction of their knowledge. With the use of books and writings of Malba Tahan is possible to work with mathematics, as a curriculum component, fostering the development of skills and Mathematics skills in students. Thus, this study aims to understand which skills and Mathematics skills can be developed with the storytelling of The Case of the Four Fours in Basic Education. Through the telling of this story, students develop the skills related to the block / shaft Numbers and Operations, present in official documents, and other skills and mathematics skills

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper discusses the influence of the design parameters in the operation and construction of an internal combustion engine. A theoretical analysis was developed using a standard crank-connecting rod-piston to verify the behavior of the stresses generated in the combustion and transformed into rotational energy of the crank shaft. Design parameters directly influence not only the final result of the characteristics of power and torque, but how the engine must be built to withstand different loads. The choice of parameters of a combustion engine is directly linked with the application of the engine and the final result expected of it function

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Disposição construtiva aplicada em cadeira antropométrica. Patente de modelo de utilidade para uma cadeira antropométrica constituída de uma estrutura (1) que sustenta uma pluralidade de instrumentos de medição, sendo que a parte posterior da cadeira é provida de dois instrumentos de medição compostos por duas hastes, sendo uma delas para medida da altura tronco-encefálica (2) e a outra para a medida do assento até a região renal (4), de modo que cada uma dessas hastes possui uma escala numérica, sendo ora interna (3), ora externa (5). O assento (6) da cadeira (1) é composto por um anteparo com uma canaleta interna e dois cursores laterais deslizantes para a direita e para a esquerda, que possuem escala numérica.; O assento é provido de referências métricas sendo uma no sentido da largura do assento (8) e outra no sentido da profundidade do assento (9), sendo a escala (8) dividida em duas escalas, onde o ponto zero é exatamente o meio do assento. O assento (6) também possui acoplada uma haste frontal, com deslizamento no sentido antero-posterior (10), a qual contém uma escala interna embutida na peça, de modo que a soma entre a medida da profundidade do assento com a medida obtida pela haste deslizante horizontal (10) totalizam a medida sacro-poplítea. Para a tomada da medida da altura poplítea, há uma outra haste (11), integrada à superfície anterior da cadeira, cujo deslizamento é vertical, sendo que essa haste (11) possui uma escala numérica interna uma externa (12).; A base da cadeira (13) possui um dispositivo de acionamento lateral com o pé (16), que é conectado ao assento (6) por meio de um macaco hidráulico, permitindo a elevação do assento, sendo que a outra alavanca (17), ao ser girada, realiza a descida do assento (6).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

ObjectiveThis study aimed to evaluate the benefit and specifically the feasibility of using ultrasound in ophthalmologic periconal block, and the occurrence of complications.Study designProspective experimental study.AnimalsTen healthy New Zealand White rabbits (6-8months of age), weighing 2.0-3.5kg.MethodsRabbits were anesthetized by intramuscular injection of acepromazine (1mgkg(-1)), ketamine (30mgkg(-1)) and xylazine (3mgkg(-1)). Ultrasound-assisted periconal block with lidocaine was performed on 18 eyes. Intraocular pressure was measured by applanation tonometry whereas corneal sensitivity was assessed using an esthesiometer, before and after each periconal anesthesia.ResultsIn all 18 eyes, it was possible to adequately visualize the needle shaft within the periconal space, as well as muscular cone, optic nerve and local anesthetic solution spread. Lidocaine 2% without epinephrine (0.790.19mL) was injected into the periconal space. There was no statistical difference between the intraocular pressure (meanSD) measured before (10.9 +/- 2.9mmHg) and after (11.9 +/- 3.8mmHg) the periconal anesthesia (p=0.38). The effectiveness of the ultrasound-assisted technique was shown according to the values for corneal sensitivity, assessed before and after periconal anesthesia (p<0.0001). Complications were not observed in this study.ConclusionsEye ultrasonography allowed visualization of all anatomic structures necessary to perform a periconal block, as well as the needle insertion and anesthetic spread in real time. Further studies are required to prove the real potential of ultrasound for reducing the incidence of complications associated with ophthalmic blocks, especially when anatomic disorders of the eye could potentially increase the risk.Clinical relevanceUltrasonography is a painless, noninvasive tool that may improve safety of ophthalmic regional blocks, potentially by reducing the prevalence of globe perforation or penetration of the optic nerve associated with the needle-based techniques.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Soil compaction is one of the limiting factors in areas subjected to direct seeding. The method used to break up the compacted layer should disturb the soil as little as possible, as well as maintain the ground cover. The aim of this study was to evaluate the influence of subsoiling, scarification and use of shaft-type furrowing mechanisms when sowing, on preserving the ground cover, water content and soil density, as well as the effects on maize yield in a dystroferic Red Nitosol, cultivated under a system of direct seeding for ten years. The experimental design was of randomised blocks, with eight soil management treatments: subsoiling to a depth of 0.40 m before sowing the winter crop, subsoiling to 0.40 m before sowing the maize, scarification to 0.30 m before the winter crop, scarification to 0.30 m before the maize, scarification to 0.20 m before the winter crop, scarification to 0.20 m before the maize, direct seeding of the maize with a shaft-type furrowing mechanism and direct seeding of the maize using a double disc furrower. There were four replications. Subsoiling and scarification influenced the preservation of the ground cover, soil density and water content immediately after sowing, but did not interfere in plant development or grain yield in the maize crop. The use of shaft-type furrowing mechanisms in the sowing operation had no effect on any of the parameters under study.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Natural frequencies were analyzed (axial, torsional and flexural) and frequency response of a vertical rotor with a hard disk at the edge through the classical and complex modal analysis. The mathematical modeling was based on the theory of Euler-Bernoulli beam. The equation that rules the movement was obtained through the Lagrangian formulation. The model considered the effects of bending, torsion and axial deformation of the shaft, besides the gravitational and gyroscopic effects. The finite element method was used to discretize the structure into hollow cylindrical elements with 12 degrees of freedom. Mass, stiffness and gyroscopic matrices were explained consistently. This type of tool, based on the use of complex coordinates to describe the dynamic behavior of rotating shaft, allows the decomposition of the system in two submodes, backward and forward. Thus, it is possible to clearly visualize that the orbit and direction of the precessional motion around the line of the rotating shaft is not deformed. A finite element program was developed using Matlab ®, and numerical simulations were performed to validate this model.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Most of the primary pulmonary tumors in dogs are malignant and from epithelial origin, being bronchioalveolar tumors more prevalent. Adenocarcinoma of clear cells, however, is a very rare pulmonary tumor and its origin is still unknown. It is related to several clinical abnormalities, including hypertrophic osteopathy, an unusual paraneoplastic syndrome characterized by a periosteal reaction along the shaft of long bones. Because of the unusual presentation of the pulmonary adenocarcinoma, the aim of this study was to describe the radiographic, histopathological, and immunohistochemical fi ndings of a dog affl icted with hypertrophic osteopathy secondary to an undifferentiated pulmonary adenocarcinoma of clear cells. Case: A 12-year-old, 45 kg, not castrated male Great Dane dog was presented with painful swelling of all four limbs and moderate respiratory distress. Radiographic examination and computed tomography of the limbs showed palisade-like periosteal bone proliferation involving radius, ulna, femur, patella, tibia, fi bula, tarsus, metacarpal, metatarsal and digits, suggesting hypertrophic osteopathy. Radiographic examination and computed tomography of the lungs also showed a round mass well delimited localized in the right diaphragmatic lobe. A lobectomy of the right diaphragmatic lobe and partial lobectomy of accessory lobe were performed. A poorly differentiated clear squamous cell carcinoma was diagnosed by histological examination. An immune-panel of CK5/CK6, CK7, p63 and TTF-1 was used for immunophenotyping. Immunostaining was weakly positive for CK5/CK6 and negative to all others. Therefore, the diagnosis was poorly differentiated clear cell adenocarcinoma. The dog showed improvement in clinical signs seven days after surgery. One month postoperatively, radiographic examination of the limbs showed less intense periosteal reaction and initiation of bone remodeling. Discussion: Primary pulmonary tumors are considered very infrequent in small animals, but its true incidence rate is dif- fi cult to establish in animal populations. The histological origin of the tumor in the present case, as verifi ed in the literature, is not well established by histological analysis. In these situations, the immunohistochemistry panel may be useful. The modifi cation of the diagnosis between histological analysis and by immunohistochemistry, among other factors, might be due to transdifferentiation from one phenotype to another at various stages in the neoplastic process. The clear cell appearance observed in this case may be verifi ed in all types of carcinoma due to intracellular accumulation of glycogen, most of which is dissolved during the preparation of paraffi n sections. This uncommon neoplasm apparently did not infl uence the radiographic or tomographic fi ndings of the hypertrophic osteopathy in the present case. The frequency of metastases depends on the histological type of the tumor, being common in the pulmonary adenocarcinoma and usually to tracheobronchial lymph nodes and pulmonary parenchyma. Although in this case the imaging studies did not show metastases to other pulmonary lobes, the histological exams showed metastatic lesions that may be associated to the dog’s death after the surgery.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Mecânica - FEG

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Elétrica - FEIS

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A gear Box in a Baja SAE vehicle is required due to the objectives of the SAE competitions, which the vehicles are challenged to pass through different obstacles. A powertrain system has as the main objective the extension of the torque for the traction shaft of the vehicle, when compared to that one available in the engine. The Objective of this thesis is the description of a gear box project for a Baja SAE vehicle of the Piratas do Vale Team of Unesp Guaratinguetá. In the development of the thesis, a flowchart, developed by the team, was used, which includes a theory part and also the choice of shelf components. In this Project, the type of gearbox was chosen, besides the calculation of axles, gears, bearings and sealers, and software simulations were done for the critical parts. The transmission, developed in this thesis, is more complex than the current one used by the team, but the new one shows improvements, as a new reverse gear with high torque

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this work the main concepts to apply to dynamic signal analysis technique for rotating machines known as order analysis, discussing their characteristics and applying it on an experimental test rig. It aims to characterize the dynamic behavior of experimental test rig in run up and run down tests, it's operational speed range and the identification of the critical speed of shaft rotation. The results of the critical speed and stationary natural frequency of the shaft are discussed