995 resultados para electronic portal imaging
Resumo:
The alternate current biosusceptometry (ACB) is a biomagnetic technique used to study some physiological parameters associated with gastrointestinal (GI) tract. For this purpose it applies an AC magnetic field and measures the response originating from magnetic marks or tracers. This paper presents an equipment based on the ACB which uses anisotropic magnetoresistive (AMR) sensors and an inexpensive electronic support. The ACB-AMR developed consists of a square array of 6x6 sensors arranged in a firstorder gradiometer configuration with one reference sensor. The equipment was applied to capture magnetic images of different phantoms and to acquire gastric contraction activity of healthy rats. The results show a reasonable sensitivity and spatial-temporal resolution, so that it may be applied for imaging of phantoms and signal acquisition of the GI tract of small animals. © 2010 IEEE.
Resumo:
Pós-graduação em Pesquisa e Desenvolvimento (Biotecnologia Médica) - FMB
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Considering the context that integrates the internet and the information, the present paper has aimed to analyze the content from the juridical portal named Migalhas, more specifically the daily information–newsletter that is sent to its readers. Starting by the passage on the pathway of the internet, cyber culture and web journalism, and some concepts of news production, it is aimed to describe and evaluate, from the content of the proposed analyzes by Laurence Bardin, about general aspects, strategies and bulletin samples. Bringing a little of its history and description of the journalistic and news main points. The present paper approaches how these criteria, news value, and tools are chosen and used to reach the effectiveness of the proposal to take specific and fast information to the readers. Questions regarded to the opinionated character from the content were also stated as a way to evaluate its expressiveness
Resumo:
Through-wall imaging (TWI) may provide vital information on interior environment in cases when physically entering such environment would pose danger to the person involved. The concept of ultra wideband radar (UWB radar) is an emerging technology, which offers high spatial resolution, as opposed to narrow band radars. Thus, TWI applications using UWB radar have become a growing field of research with several applications in the civil and defense areas such as rescue and surveillance. For this study, a prototype system of UWB radar to TWI has been built. Analyses and result to several kinds of experiments have been presented, that is, detection and visualization of metallic targets behind wooden board wall and concrete blocks wall. The results are encouraging and show the advantages of using UWB radar for TWI. (C) 2011 Wiley Periodicals, Inc. Microwave Opt Technol Lett, 54:339-344, 2012; View this article online at wileyonlinelibrary.com. DOI 10.1002/mop.26543
Resumo:
Excitation of tert-butylnitrite into the first and second UV absorption bands leads to efficient dissociation into the fragment radicals NO and tert-butoxy in their electronic ground states (2)Π and (2)E, respectively. Velocity distributions and angular anisotropies for the NO fragment in several hundred rotational and vibrational quantum states were obtained by velocity-map imaging and the recently developed 3D-REMPI method. Excitation into the well resolved vibronic progression bands (k = 0, 1, 2) of the NO stretch mode in the S(1) ← S(0) transition produces NO fragments mostly in the vibrational state with v = k, with smaller fractions in v = k - 1 and v = k - 2. It is concluded that dissociation occurs on the purely repulsive PES of S(1) without barrier. All velocity distributions from photolysis via the S(1)(nπ*) state are monomodal and show high negative anisotropy (β ≈ -1). The rotational distributions peak near j = 30.5 irrespective of the vibronic state S(1)(k) excited and the vibrational state v of the NO fragment. On average 46% of the excess energy is converted to kinetic energy, 23% and 31% remain as internal energy in the NO fragment and the t-BuO radical, respectively. Photolysis via excitation into the S(2) ← S(0) transition at 227 nm yields NO fragments with about equal populations in v = 0 and v = 1. The rotational distributions have a single maximum near j = 59.5. The velocity distributions are monomodal with positive anisotropy β ≈ 0.8. The average fractions of the excess energy distributed into translation, internal energy of NO, and internal energy of t-BuO are 39%, 23%, and 38%, respectively. In all cases ∼8500 cm(-1) of energy remain in the internal degrees of freedom of the t-BuO fragment. This is mostly assigned to rotational energy. An ab initio calculation of the dynamic reaction path shows that not only the NO fragment but also the t-BuO fragment gain large angular momentum during dissociation on the purely repulsive potential energy surface of S(2).
Resumo:
OBJECTIVE: To determine the accuracy of magnetic resonance imaging criteria for the early diagnosis of multiple sclerosis in patients with suspected disease. DESIGN: Systematic review. DATA SOURCES: 12 electronic databases, citation searches, and reference lists of included studies. Review methods Studies on accuracy of diagnosis that compared magnetic resonance imaging, or diagnostic criteria incorporating such imaging, to a reference standard for the diagnosis of multiple sclerosis. RESULTS: 29 studies (18 cohort studies, 11 other designs) were included. On average, studies of other designs (mainly diagnostic case-control studies) produced higher estimated diagnostic odds ratios than did cohort studies. Among 15 studies of higher methodological quality (cohort design, clinical follow-up as reference standard), those with longer follow-up produced higher estimates of specificity and lower estimates of sensitivity. Only two such studies followed patients for more than 10 years. Even in the presence of many lesions (> 10 or > 8), magnetic resonance imaging could not accurately rule multiple sclerosis in (likelihood ratio of a positive test result 3.0 and 2.0, respectively). Similarly, the absence of lesions was of limited utility in ruling out a diagnosis of multiple sclerosis (likelihood ratio of a negative test result 0.1 and 0.5). CONCLUSIONS: Many evaluations of the accuracy of magnetic resonance imaging for the early detection of multiple sclerosis have produced inflated estimates of test performance owing to methodological weaknesses. Use of magnetic resonance imaging to confirm multiple sclerosis on the basis of a single attack of neurological dysfunction may lead to over-diagnosis and over-treatment.
Resumo:
BACKGROUND: Until August 2004 there were 106 forensic cases examined with postmortem multislice computed tomography (MSCT) and magnetic resonance (MR) imaging before traditional autopsy within the Virtopsy project. Intrahepatic gas (IHG) was a frequent finding in postmortem MSCT examinations. The aim of this study was to investigate its cause and significance. METHODS: There were 84 virtopsy cases retrospectively investigated concerning the occurrence, location, and volume of IHG in postmortem MSCT imaging (1.25 mm collimation, 1.25 mm thickness). We assessed and noted the occurrence of intestinal distention, putrefaction, and systemic gas embolisms and the cause of death, possible open trauma, possible artificial respiration, and the postmortem interval. We investigated the relations between the findings using the contingency table (chi2 test) and the comparison of the postmortem intervals in both groups was performed using the t test in 79 nonputrefied corpses. RESULTS: IHG was found in 47 cases (59.5%). In five of the cases, the IHG was caused or influenced by putrefaction. Gas distribution within the liver of the remaining 42 cases was as follows: hepatic arteries in 21 cases, hepatic veins in 35 cases, and portal vein branches in 13 cases; among which combinations also occurred in 20 cases. The presence of IHG was strongly related to open trauma with systemic gas. Pulmonary barotrauma as occurring under artificial respiration or in drowning also caused IHG. Putrefaction did not seem to influence the occurrence of IHG until macroscopic signs of putrefaction were noticeable. CONCLUSIONS: IHG is a frequent finding in traumatic causes of death and requires a systemic gas embolism. Exceptions are putrefied or burned corpses. Common clinical causes such as necrotic bowel diseases appear rarely as a cause of IHG in our forensic case material.
Resumo:
BACKGROUND AND AIMS: The splanchnic circulation has an important function in the body under both physiological and pathophysiological conditions. Despite its importance, no reliable noninvasive procedures for estimating splanchnic circulation have been established. The aim of this study was to evaluate MRI as a tool for assessing intra-abdominal blood flows of the aorta, portal vein (VPO) and the major intestinal and hepatic vessels. METHODS: In nine healthy volunteers, the proximal aorta (AOP) and distal abdominal aorta (AOD), superior mesenteric artery (SAM), celiac trunk (CTR), hepatic arteries (common and proper hepatic arteries, AHC and AHP, respectively), and VPO were localized on contrast-enhanced magnetic resonance angiography images. Volumetric flow was measured using a two-dimensional cine echocardiogram-gated phase contrast technique. Measurements were taken before and 30 min after continuous intravenous infusion of somatostatin (250 microg/h) and were independently evaluated by two investigators. RESULTS: Blood flow measured by MRI in the VPO, SAM, AOP, AHP, and CTR significantly decreased after drug infusion. Flows in the AOD and AHC showed a tendency to decrease (P>0.05). Interrater agreement on flows in MRI was very good for large vessels (VPO, AOP, and AOD), with a concordance correlation coefficient of 0.94, as well as for smaller vessels such as the CTR, AHC, AHP, and SAM (concordance correlation coefficient =0.78). CONCLUSION: Somatostatin-induced blood flow changes in the splanchnic region were reliably detected by MRI. MRI may be useful for the noninvasive assessment of blood flow changes in the splanchnic region.
Resumo:
Purpose: To assess liver remnant volume regeneration and maintenance, and complications in the long-time follow-up of donors after living donor liver transplantation using CT and MRI. Materials and Methods: 47 donors with a mean age of 33.5 years who donated liver tissue for transplantation and who were available for follow-up imaging were included in this retrospective study. Contrast-enhanced CT and MR studies were acquired for routine follow-up. Two observers evaluated pre- and postoperative images regarding anatomy and pathological findings. Volumes were manually measured on contrast-enhanced images in the portal venous phase, and potential postoperative complications were documented. Pre- and postoperative liver volumes were compared for evaluating liver remnant regeneration. Results: 47 preoperative and 89 follow-up studies covered a period of 22.4 months (range: 1 - 84). After right liver lobe (RLL) donation, the mean liver remnant volume was 522.0 ml (± 144.0; 36.1 %; n = 18), after left lateral section (LLS) donation 1,121.7 ml (± 212.8; 79.9 %; n = 24), and after left liver lobe (LLL) donation 1,181.5 ml (± 279.5; 72.0 %; n = 5). Twelve months after donation, the liver remnant volume were 87.3 % (RLL; ± 11.8; n = 11), 95.0 % (LS; ± 11.6; n = 18), and 80.1 % (LLL; ± 2.0; n = 2 LLL) of the preoperative total liver volume. Rapid initial regeneration and maintenance at 80 % of the preoperative liver volume were observed over the total follow-up period. Minor postoperative complications were found early in 4 patients. No severe or late complications or mortality occurred. Conclusion: Rapid regeneration of liver remnant volumes in all donors and volume maintenance over the long-term follow-up period of up to 84 months without severe or late complications are important observations for assessing the safety of LDLT donors. Key Points: Liver remnant volumes of LDLT donors rapidly regenerated after donation and volumes were maintained over the long-term follow-up period of up to 84 months without severe or late complications.
Resumo:
OBJECTIVE The aim of the present study was to evaluate a dose reduction in contrast-enhanced chest computed tomography (CT) by comparing the three latest generations of Siemens CT scanners used in clinical practice. We analyzed the amount of radiation used with filtered back projection (FBP) and an iterative reconstruction (IR) algorithm to yield the same image quality. Furthermore, the influence on the radiation dose of the most recent integrated circuit detector (ICD; Stellar detector, Siemens Healthcare, Erlangen, Germany) was investigated. MATERIALS AND METHODS 136 Patients were included. Scan parameters were set to a thorax routine: SOMATOM Sensation 64 (FBP), SOMATOM Definition Flash (IR), and SOMATOM Definition Edge (ICD and IR). Tube current was set constantly to the reference level of 100 mA automated tube current modulation using reference milliamperes. Care kV was used on the Flash and Edge scanner, while tube potential was individually selected between 100 and 140 kVp by the medical technologists at the SOMATOM Sensation. Quality assessment was performed on soft-tissue kernel reconstruction. Dose was represented by the dose length product. RESULTS Dose-length product (DLP) with FBP for the average chest CT was 308 mGy*cm ± 99.6. In contrast, the DLP for the chest CT with IR algorithm was 196.8 mGy*cm ± 68.8 (P = 0.0001). Further decline in dose can be noted with IR and the ICD: DLP: 166.4 mGy*cm ± 54.5 (P = 0.033). The dose reduction compared to FBP was 36.1% with IR and 45.6% with IR/ICD. Signal-to-noise ratio (SNR) was favorable in the aorta, bone, and soft tissue for IR/ICD in combination compared to FBP (the P values ranged from 0.003 to 0.048). Overall contrast-to-noise ratio (CNR) improved with declining DLP. CONCLUSION The most recent technical developments, namely IR in combination with integrated circuit detectors, can significantly lower radiation dose in chest CT examinations.
Resumo:
The Centro de Micro-Análisis de Materiales (CMAM) in the Universidad Autónoma de Madrid is carrying out an extensive research program on the processes induced by high energy heavy mass ions (SHI) on dielectric materials and their photonic applications [1?21]. A significant part of this activity constitutes a relevant contribution to the scientific program associated to the TECHNOFUSION project. It is performed in collaboration with the Instituto de Fusion Nuclear at the UPM, the CIEMAT, the Departamento de Física de Materiales at UAM and several other national institutions (INTA) and international laboratories (GANIL, France), Legnaro Italy, Grenoble?. The program has led to a large number of publications in reputed international journals.
Resumo:
Para a adequada implantação de um Programa de Concessão, Adaptação e Acompanhamento do Sistema FM em estudantes com deficiência auditiva nas escolas brasileiras é necessário um trabalho intersetorial, caracterizado por uma cuidadosa articulação entre os Sistemas Educacional e de Saúde. As ações em rede integrarão os diferentes níveis de atenção da pessoa com deficiência auditiva, conforme a nova política interministerial Viver Sem Limites. O objetivo deste estudo foi desenvolver e analisar a eficácia de um ambiente virtual de transmissão de informações sobre Sistema FM para profissionais utilizando a Teleducação Interativa. Devido à distribuição geográfica dos profissionais que atuam com a adaptação do Sistema FM em alunos usuários de Sistema FM foi proposto o acesso aos módulos à distância (Teleducação) via internet por meio do Portal Sistema FM disponibilizado em endereço eletrônico http://portalsistemafm.fob.usp.br/. O portal é composto por 7 módulos, sendo que todos os materiais foram transformados em infográficos, com possibilidade de download. Realizaram o cadastro no Portal Sistema FM 50 profissionais que atuam em Serviços de Saúde Auditiva credenciados pelo SUS, sendo que 31 fonoaudiólogos avaliaram o Portal Sistema FM. Para a avaliação do programa de capacitação foram propostos os instrumentos Ficha de Pesquisa Motivacional, Escala de Autoavaliação de Impacto do Treinamento no trabalho - medida de amplitude e um Questionário sobre o conteúdo teórico, todos contidos em um módulo do Portal. Os fonoaudiólogos, respondendo a Ficha de Pesquisa Motivacional, consideraram o Portal Sistema FM com expectativa para o sucesso. A Escala de Impacto no Trabalho demonstrou que o acesso aos módulos do Portal Sistema FM gerou um impacto no trabalho dos participantes, quando aplicado após o primeiro acesso e dois meses depois, porém não foi indicada diferença estatisticamente significante quando comparadas. No questionário sobre o conteúdo teórico os participantes obtiveram uma média de 79,03% de acerto. O Portal Sistema FM foi criado e encontra-se disponível no endereço eletrônico http://portalsistemafm.fob.usp.br/, sendo avaliado como um portal impressionante quanto à motivação dos participantes. O acesso aos módulos trouxe impacto no trabalho dos profissionais.
Resumo:
Nanometer-sized metallic necks have the unique ability to sustain extreme uniaxial loads (about 20 times greater than the bulk material). We present an experimental and theoretical study of the electronic transport properties under such extreme conditions. Conductance measurements on gold and aluminum necks show a strikingly different behavior: While gold shows the expected conductance decrease with increasing elastic elongation of the neck, aluminum necks behave in the opposite way. We have performed first-principles electronic-structure calculations which reproduce this behavior, showing that it is an intrinsic property of the bulk band structure under high uniaxial strain.