948 resultados para deterministic safety analysis


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Risk acceptance has been broadly discussed in relation to hazardous risk activities and/or technologies. A better understanding of risk acceptance in occupational settings is also important; however, studies on this topic are scarce. It seems important to understand the level of risk that stakeholders consider sufficiently low, how stakeholders form their opinion about risk, and why they adopt a certain attitude toward risk. Accordingly, the aim of this study is to examine risk acceptance in regard to occupational accidents in furniture industries. The safety climate analysis was conducted through the application of the Safety Climate in Wood Industries questionnaire. Judgments about risk acceptance, trust, risk perception, benefit perception, emotions, and moral values were measured. Several models were tested to explain occupational risk acceptance. The results showed that the level of risk acceptance decreased as the risk level increased. High-risk and death scenarios were assessed as unacceptable. Risk perception, emotions, and trust had an important influence on risk acceptance. Safety climate was correlated with risk acceptance and other variables that influence risk acceptance. These results are important for the risk assessment process in terms of defining risk acceptance criteria and strategies to reduce risks.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Work-related musculoskeletal disorders (WMSD) became one of the biggest health problems in the workplace and one of the main concerns of ergonomics and despite all the technical improvements manual handling is still an important risk factor for WMSD. The current study was performed with the main objective of conducting an ergonomic analysis in a workplace that consists in packaging products in a pallet, in a food distribution industry, also called picking. In this perspective, the aim of the study is to identify if the tasks performed by operators present any risk of WMSD and, if so, to suggest proposals for minimizing the associated effort. The methodologies of ergonomic risk assessment that were initially applied were the Risk Reckoner and the Manual Handling Assessment Chart (MAC). Subsequently, in order to, on the one hand, complement the analysis performed using the two methods previously mentioned, and, on the other hand, allow an assessment of two important risk factors associated with this activity (work postures and loads handling), two additional methodologies were also selected: the Revised NIOSH Lifting Equation and the Rapid Entire Body Assessment (REBA). In all the performed approaches, the tasks of palletizing at lower levels were identified as the ones that most penalize workers in what regards the risk of development of WMSD. All methodologies identified levels of risk that require an immediate or short-term ergonomic intervention, aiming at ensuring the safety and health of workers performing such activity. The implementation of measures designed to eliminate or minimize the risk may involve the allocation of significant human and material resources that is increasingly necessary to manage efficiently. Taking into account the complexity and variability of the developed tasks, it is recommended that such a decision can be preceded by a new study using more accurate risk assessment methodologies, such as those that use monitoring tools.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The production of nanotechnology-based products is increasing, along with the conscience of the possible harmful effects of some nanomaterials. The “safety-by-design” approaches are getting attention as helpful tools to develop safer products and production processes. The Systematic Design Analysis Approach could help to identify the solutions to control the workplace risks by defining the emission and exposure scenarios and the possible barriers to interrupt them. By applying this approach in a photocatalytic ceramic tiles development project it was possible to identify relevant nanoparticles emission scenarios and related barriers, and defining possible ways to reduce it.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The monitoring data collected during tunnel excavation can be used in inverse analysis procedures in order to identify more realistic geomechanical parameters that can increase the knowledge about the interested formations. These more realistic parameters can be used in real time to adapt the project to the real structure in situ behaviour. However, monitoring plans are normally designed for safety assessment and not especially for the purpose of inverse analysis. In fact, there is a lack of knowledge about what types and quantity of measurements are needed to succeed in identifying the parameters of interest. Also, the optimisation algorithm chosen for the identification procedure may be important for this matter. In this work, this problem is addressed using a theoretical case with which a thorough parametric study was carried out using two optimisation algorithms based on different calculation paradigms, namely a conventional gradient-based algorithm and an evolution strategy algorithm. Calculations were carried for different sets of parameters to identify several combinations of types and amount of monitoring data. The results clearly show the high importance of the available monitoring data and the chosen algorithm for the success rate of the inverse analysis process.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Dissertação de mestrado integrado em Engenharia Civil

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The presence of mycotoxins in foodstuff is a matter of concern for food safety. Mycotoxins are toxic secondary metabolites produced by certain molds, being ochratoxin A (OTA) one of the most relevant. Wines can also be contaminated with these toxicants. Several authors have demonstrated the presence of mycotoxins in wine, especially ochratoxin A (OTA) [1]. Its chemical structure is a dihydro-isocoumarin connected at the 7-carboxy group to a molecule of L--phenylalanine via an amide bond. As these toxicants can never be completely removed from the food chain, many countries have defined levels in food in order to attend health concerns. OTA contamination of wines might be a risk to consumer health, thus requiring treatments to achieve acceptable standards for human consumption [2]. The maximum acceptable level of OTA in wines is 2.0 g/kg according to the Commission regulation No. 1881/2006 [3]. Therefore, the aim of this work was to reduce OTA to safer levels using different fining agents, as well as their impact on white wine physicochemical characteristics. To evaluate their efficiency, 11 commercial fining agents (mineral, synthetic, animal and vegetable proteins) were used to get new approaches on OTA removal from white wine. Trials (including a control without addition of a fining agent) were performed in white wine artificially supplemented with OTA (10 µg/L). OTA analysis were performed after wine fining. Wine was centrifuged at 4000 rpm for 10 min and 1 mL of the supernatant was collected and added of an equal volume of acetonitrile/methanol/acetic acid (78:20:2 v/v/v). Also, the solid fractions obtained after fining, were centrifuged (4000 rpm, 15 min), the resulting supernatant discarded, and the pellet extracted with 1 mL of the above solution and 1 mL of H2O. OTA analysis was performed by HPLC with fluorescence detection according to Abrunhosa and Venâncio [4]. The most effective fining agent in removing OTA (80%) from white wine was a commercial formulation that contains gelatine, bentonite and activated carbon. Removals between 10-30% were obtained with potassium caseinate, yeast cell walls and pea protein. With bentonites, carboxymethylcellulose, polyvinylpolypyrrolidone and chitosan no considerable OTA removal was verified. Following, the effectiveness of seven commercial activated carbons was also evaluated and compared with the commercial formulation that contains gelatine, bentonite and activated carbon. The different activated carbons were applied at the concentration recommended by the manufacturer in order to evaluate their efficiency in reducing OTA levels. Trial and OTA analysis were performed as explained previously. The results showed that in white wine all activated carbons except one reduced 100% of OTA. The commercial formulation that contains gelatine, bentonite and activated carbon (C8) reduced only 73% of OTA concentration. These results may provide useful information for winemakers, namely for the selection of the most appropriate oenological product for OTA removal, reducing wine toxicity and simultaneously enhancing food safety and wine quality.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: To assess safety and efficacy of coronary angioplasty with stent implantation in unstable coronary syndromes. METHODS: Retrospective analysis of in-hospital and late evolution of 74 patients with unstable coronary syndromes (unstable angina or infarction without elevation of the ST segment) undergoing coronary angioplasty with stent placement. These 74 patients were compared with 31 patients with stable coronary syndromes (stable angina or stable silent ischemia) undergoing the same procedure. RESULTS: No death and no need for revascularization of the culprit artery occurred in the in-hospital phase. The incidences of acute non-Q-wave myocardial infarction were 1.4% and 3.2% (p=0.6) in the unstable and stable coronary syndrome groups, respectively. In the late follow-up (11.2±7.5 months), the incidences of these events combined were 5.7% in the unstable coronary syndrome group and 6.9% (p=0.8) in the stable coronary syndrome group. In the multivariate analysis, the only variable with a tendency to significance as an event predictor was diabetes mellitus (p=0.07; OR=5.2; 95% CI=0.9-29.9). CONCLUSION: The in-hospital and late evolutions of patients with unstable coronary syndrome undergoing angioplasty with intracoronary stent implantation are similar to those of the stable coronary syndrome group, suggesting that this procedure is safe and efficacious when performed in unstable coronary syndrome patients.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: To assess safety, feasibility, and the results of early exercise testing in patients with chest pain admitted to the emergency room of the chest pain unit, in whom acute myocardial infarction and high-risk unstable angina had been ruled out. METHODS: A study including 1060 consecutive patients with chest pain admitted to the emergency room of the chest pain unit was carried out. Of them, 677 (64%) patients were eligible for exercise testing, but only 268 (40%) underwent the test. RESULTS: The mean age of the patients studied was 51.7±12.1 years, and 188 (70%) were males. Twenty-eight (10%) patients had a previous history of coronary artery disease, 244 (91%) had a normal or unspecific electrocardiogram, and 150 (56%) underwent exercise testing within a 12-hour interval. The results of the exercise test in the latter group were as follows: 34 (13%) were positive, 191 (71%) were negative, and 43 (16%) were inconclusive. In the group of patients with a positive exercise test, 21 (62%) underwent coronary angiography, 11 underwent angioplasty, and 2 underwent myocardial revascularization. In a univariate analysis, type A/B chest pain (definitely/probably anginal) (p<0.0001), previous coronary artery disease (p<0.0001), and route 2 (patients at higher risk) correlated with a positive or inconclusive test (p<0.0001). CONCLUSION: In patients with chest pain and in whom acute myocardial infarction and high-risk unstable angina had been ruled out, the exercise test proved to be feasible, safe, and well tolerated.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectives Nosocomial Pseudomonas aeruginosa pneumonia remains a major concern in critically ill patients. We explored the potential impact of microorganism-targeted adjunctive immunotherapy in such patients. Patients and methods This multicentre, open pilot Phase 2a clinical trial (NCT00851435) prospectively evaluated the safety, pharmacokinetics and potential efficacy of three doses of 1.2 mg/kg panobacumab, a fully human monoclonal anti-lipopolysaccharide IgM, given every 72 h in 18 patients developing nosocomial P. aeruginosa (serotype O11) pneumonia. Results Seventeen out of 18 patients were included in the pharmacokinetic analysis. In 13 patients receiving three doses, the maximal concentration after the third infusion was 33.9 ± 8.0 μg/mL, total area under the serum concentration-time curve was 5397 ± 1993 μg h/mL and elimination half-life was 102.3 ± 47.8 h. Panobacumab was well tolerated, induced no immunogenicity and was detected in respiratory samples. In contrast to Acute Physiology and Chronic Health Evaluation II (APACHE II) prediction, all 13 patients receiving three doses survived, with a mean clinical resolution in 9.0 ± 2.7 days. Two patients suffered a recurrence at days 17 and 20. Conclusions These data suggest that panobacumab is safe, with a pharmacokinetic profile similar to that in healthy volunteers. It was associated with high clinical cure and survival rates in patients developing nosocomial P. aeruginosa O11 pneumonia. We concluded that these promising results warrant further trials.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: The number of requests to pre-hospital emergency medical services (PEMS) has increased in Europe over the last 20 years, but epidemiology of PEMS interventions has little be investigated. The aim of this analysis was to describe time trends of PEMS activity in a region of western Switzerland. METHODS: Use of data routinely and prospectively collected for PEMS intervention in the Canton of Vaud, Switzerland, from 2001 to 2010. This Swiss Canton comprises approximately 10% of the whole Swiss population. RESULTS: We observed a 40% increase in the number of requests to PEMS between 2001 and 2010. The overall rate of requests was 35/1000 inhabitants for ambulance services and 10/1000 for medical interventions (SMUR), with the highest rate among people aged ≥ 80. Most frequent reasons for the intervention were related to medical problems, predominantly unconsciousness, chest pain respiratory distress, or cardiac arrest, whereas severe trauma interventions decreased over time. Overall, 89% were alive after 48 h. The survival rate after 48 h increased regularly for cardiac arrest or myocardial infarction. CONCLUSION: Routine prospective data collection of prehospital emergency interventions and monitoring of activity was feasible over time. The results we found add to the understanding of determinants of PEMS use and need to be considered to plan use of emergency health services in the near future. More comprehensive analysis of the quality of services and patient safety supported by indicators are also required, which might help to develop prehospital emergency services and new processes of care.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Pathogen reduction of platelets (PRT-PLTs) using riboflavin and ultraviolet light treatment has undergone Phase 1 and 2 studies examining efficacy and safety. This randomized controlled clinical trial (RCT) assessed the efficacy and safety of PRT-PLTs using the 1-hour corrected count increment (CCI(1hour) ) as the primary outcome. STUDY DESIGN AND METHODS: A noninferiority RCT was performed where patients with chemotherapy-induced thrombocytopenia (six centers) were randomly allocated to receive PRT-PLTs (Mirasol PRT, CaridianBCT Biotechnologies) or reference platelet (PLT) products. The treatment period was 28 days followed by a 28-day follow-up (safety) period. The primary outcome was the CCI(1hour) determined using up to the first eight on-protocol PLT transfusions given during the treatment period. RESULTS: A total of 118 patients were randomly assigned (60 to PRT-PLTs; 58 to reference). Four patients per group did not require PLT transfusions leaving 110 patients in the analysis (56 PRT-PLTs; 54 reference). A total of 541 on-protocol PLT transfusions were given (303 PRT-PLTs; 238 reference). The least square mean CCI was 11,725 (standard error [SE], 1.140) for PRT-PLTs and 16,939 (SE, 1.149) for the reference group (difference, -5214; 95% confidence interval, -7542 to -2887; p<0.0001 for a test of the null hypothesis of no difference between the two groups). CONCLUSION: The study failed to show noninferiority of PRT-PLTs based on predefined CCI criteria. PLT and red blood cell utilization in the two groups was not significantly different suggesting that the slightly lower CCIs (PRT-PLTs) did not increase blood product utilization. Safety data showed similar findings in the two groups. Further studies are required to determine if the lower CCI observed with PRT-PLTs translates into an increased risk of bleeding.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: We analysed 5-year treatment with agalsidase alfa enzyme replacement therapy in patients with Fabry's disease who were enrolled in the Fabry Outcome Survey observational database (FOS). METHODS: Baseline and 5-year data were available for up to 181 adults (126 men) in FOS. Serial data for cardiac mass and function, renal function, pain, and quality of life were assessed. Safety and sensitivity analyses were done in patients with baseline and at least one relevant follow-up measurement during the 5 years (n=555 and n=475, respectively). FINDINGS: In patients with baseline cardiac hypertrophy, treatment resulted in a sustained reduction in left ventricular mass (LVM) index after 5 years (from 71.4 [SD 22.5] g/m(2.7) to 64.1 [18.7] g/m(2.7), p=0.0111) and a significant increase in midwall fractional shortening (MFS) from 14.3% (2.3) to 16.0% (3.8) after 3 years (p=0.02). In patients without baseline hypertrophy, LVM index and MFS remained stable. Mean yearly fall in estimated glomerular filtration rate versus baseline after 5 years of enzyme replacement therapy was -3.17 mL/min per 1.73 m(2) for men and -0.89 mL/min per 1.73 m(2) for women. Average pain, measured by Brief Pain Inventory score, improved significantly, from 3.7 (2.3) at baseline to 2.5 (2.4) after 5 years (p=0.0023). Quality of life, measured by deviation scores from normal EuroQol values, improved significantly, from -0.24 (0.3) at baseline to -0.17 (0.3) after 5 years (p=0.0483). Findings were confirmed by sensitivity analysis. No unexpected safety concerns were identified. INTERPRETATION: By comparison with historical natural history data for patients with Fabry's disease who were not treated with enzyme replacement therapy, long-term treatment with agalsidase alfa leads to substantial and sustained clinical benefits. FUNDING: Shire Human Genetic Therapies AB.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND AND PURPOSE: To assess whether the combined analysis of all phase III trials of nonvitamin-K-antagonist (non-VKA) oral anticoagulants in patients with atrial fibrillation and previous stroke or transient ischemic attack shows a significant difference in efficacy or safety compared with warfarin. METHODS: We searched PubMed until May 31, 2012, for randomized clinical trials using the following search items: atrial fibrillation, anticoagulation, warfarin, and previous stroke or transient ischemic attack. Studies had to be phase III trials in atrial fibrillation patients comparing warfarin with a non-VKA currently on the market or with the intention to be brought to the market in North America or Europe. Analysis was performed on intention-to-treat basis. A fixed-effects model was used as more appropriate than a random-effects model when combining a small number of studies. RESULTS: Among 47 potentially eligible articles, 3 were included in the meta-analysis. In 14 527 patients, non-VKAs were associated with a significant reduction of stroke/systemic embolism (odds ratios, 0.85 [95% CI, 074-0.99]; relative risk reduction, 14%; absolute risk reduction, 0.7%; number needed to treat, 134 over 1.8-2.0 years) compared with warfarin. Non-VKAs were also associated with a significant reduction of major bleeding compared with warfarin (odds ratios, 0.86 [95% CI, 075-0.99]; relative risk reduction, 13%; absolute risk reduction, 0.8%; number needed to treat, 125), mainly driven by the significant reduction of hemorrhagic stroke (odds ratios, 0.44 [95% CI, 032-0.62]; relative risk reduction, 57.9%; absolute risk reduction, 0.7%; number needed to treat, 139). CONCLUSIONS: In the context of the significant limitations of combining the results of disparate trials of different agents, non-VKAs seem to be associated with a significant reduction in rates of stroke or systemic embolism, hemorrhagic stroke, and major bleeding when compared with warfarin in patients with previous stroke or transient ischemic attack.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: The RCP is a 14 French collapsable percutaneous cardiovascular support device positioned in the descending part of the thoracic aorta via the femoral artery. A 10 patient first in man study demonstrated device safety and significant improvement in renal function among high risk PCI patients. We now report haemodynamic and renal efficacy in patients with ADHF.Methods: Prospective non randomised study seeking to recruit 20 patients with ADHF with a need for inotropic or mechanical circulatory support with: i) EF < 30% ii)Cardiac index(CI) < 2.2 L / min / m2 Outcome measures included: 1) Cardiac index (CI) 2) Pulmonary Capillary Wedge Pressure (PCWP) 3) Urine output / serum creatinine 4) Vascular / device complications 5) 30 day mortalityResults: INTERIM ANALYSIS (n=12) The mean age of the study group was 64 years, with a mean baseline creatinine of 193 umol/L, eGFR 38 ml/min. The intended RCP treatment period was 24 hours. During RCP treatment there was a significant mean reduction of PCWP at 4 hours of 17% (25 to 21 mmHg p=0.04). Mean CI increased at 12 hours by 11%, though not reaching significance (1.78 to 1.96 L/min/m2 p=0.08). RCP insertion prompted substantial diuresis. Urine output tripled over the first 12 hours compared to baseline (55 ml/hr vs 213 ml/hr p=0.03). This was associated with significantly improved renal function, a 28% reduction in serum creatinine at 12 hours (193 to 151 umol/L p=0.003), and a increase in eGFR from 38 ml/min to 50 ml/min (p=0.0007). 2 patients previously refused cardiac transplantation were reassessed and successfully transplanted within 9 months of RCP treatment on the basis of demonstrable renal reversibility. There were no vascular or device complications. There were 2 deaths at 30 days, one from multi-organ failure and sepsis, and one from intractable heart failure - neither were device related.Conclusion: RCP support in ADHF patients was associated with improved haemodynamics, and an improvement in renal function. The Reitan Catheter Pump may have a role in providing percutaneous cardiovascular and renal support in the acutely decompensated cardiac patient, and may have a role in suggesting renal reversibility in potential cardiac transplant patients. Further data will be reported at recruitment completion.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE OF REVIEW: The mechanisms involved in the formation of red blood cell (RBC) microparticles in vivo as well as during erythrocyte storage are reviewed, and the potential role of microparticles in transfusion medicine is described. RECENT FINDINGS: Microparticles release is an integral part of the erythrocyte ageing process, preventing early removal of RBCs. Proteomics analyses have outlined the key role of band 3-ankyrin anchoring complex and the occurrence of selective RBC membrane remodelling mechanisms in microparticles formation. The presence of several RBC antigens, expressed on microparticles, has been demonstrated. The potential deleterious effects of RBC microparticles in transfused recipients, including hypercoagulability, microcirculation impairment and immunosuppression, are discussed. SUMMARY: Formation and role of RBC microparticles are far from being completely understood. Combining various approaches to elucidate these mechanisms could improve blood product quality and transfusion safety. Implementation of RBC microparticles as biomarkers in the laboratory routine needs to overcome technical barriers involved in their analysis.