967 resultados para bloqueio femoral


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mechanical properties of human trabecular bone play an important role in age-related bone fragility and implant stability. Micro-finite element (microFE) analysis allows computing the apparent elastic properties of trabecular bone biopsies, but the results depend on the type of applied boundary conditions (BCs). In this study, 167 femoral trabecular cubic biopsies with a side length of 5.3 mm were analyzed using microFE analysis to compare their stiffness systematically with kinematic uniform boundary conditions (KUBCs) and periodicity-compatible mixed uniform boundary conditions (PMUBCs). The obtained elastic constants were then used in the volume fraction and fabric-based orthotropic Zysset-Curnier model to identify their respective model parameters. As expected, PMUBCs lead to more compliant apparent elastic properties than KUBCs, especially in shear. The differences in stiffness decreased with bone volume fraction and mean intercept length. Unlike KUBCs, PMUBCs were sensitive to heterogeneity of the biopsies. The Zysset-Curnier model predicted apparent elastic constants successfully in both cases with adjusted coefficients of determination of 0.986 for KUBCs and 0.975 for PMUBCs. The role of these boundary conditions in finite element analyses of whole bones and bone-implant systems will need to be investigated in future work.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Trabecular bone plays an important mechanical role in bone fractures and implant stability. Homogenized nonlinear finite element (FE) analysis of whole bones can deliver improved fracture risk and implant loosening assessment. Such simulations require the knowledge of mechanical properties such as an appropriate yield behavior and criterion for trabecular bone. Identification of a complete yield surface is extremely difficult experimentally but can be achieved in silico by using micro-FE analysis on cubical trabecular volume elements. Nevertheless, the influence of the boundary conditions (BCs), which are applied to such volume elements, on the obtained yield properties remains unknown. Therefore, this study compared homogenized yield properties along 17 load cases of 126 human femoral trabecular cubic specimens computed with classical kinematic uniform BCs (KUBCs) and a new set of mixed uniform BCs, namely periodicity-compatible mixed uniform BCs (PMUBCs). In stress space, PMUBCs lead to 7–72 % lower yield stresses compared to KUBCs. The yield surfaces obtained with both KUBCs and PMUBCs demonstrate a pressure-sensitive ellipsoidal shape. A volume fraction and fabric-based quadric yield function successfully fitted the yield surfaces of both BCs with a correlation coefficient R2≥0.93. As expected, yield strains show only a weak dependency on bone volume fraction and fabric. The role of the two BCs in homogenized FE analysis of whole bones will need to be investigated and validated with experimental results at the whole bone level in future studies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Finite element (FE) analysis is an important computational tool in biomechanics. However, its adoption into clinical practice has been hampered by its computational complexity and required high technical competences for clinicians. In this paper we propose a supervised learning approach to predict the outcome of the FE analysis. We demonstrate our approach on clinical CT and X-ray femur images for FE predictions ( FEP), with features extracted, respectively, from a statistical shape model and from 2D-based morphometric and density information. Using leave-one-out experiments and sensitivity analysis, comprising a database of 89 clinical cases, our method is capable of predicting the distribution of stress values for a walking loading condition with an average correlation coefficient of 0.984 and 0.976, for CT and X-ray images, respectively. These findings suggest that supervised learning approaches have the potential to leverage the clinical integration of mechanical simulations for the treatment of musculoskeletal conditions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND Complex proximal femoral deformities, including an elevated greater trochanter, short femoral neck, and aspherical head-neck junction, often result in pain and impaired hip function resulting from intra-/extraarticular impingement. Relative femoral neck lengthening may address these deformities, but mid-term results of this approach have not been widely reported. QUESTIONS/PURPOSES Do patients who have undergone relative femoral neck lengthening show (1) less hip pain and greater function; (2) improved radiographic parameters; (3) significant complications requiring subsequent surgery; and (4) progression of osteoarthrosis (OA) or conversion to total hip arthroplasty (THA) at mid-term followup? METHODS We retrospectively reviewed 40 patients (41 hips) with isolated relative femoral neck lengthening between 1998 and 2006 with sequelae of Legg-Calvé-Perthes disease (38 hips [93%]), slipped capital femoral epiphysis (two hips [5%]), and postseptic arthritis (one hip [2%]). During this time, the general indications for this procedure included a high-riding greater trochanter with a short femoral neck with abductor weakness and symptomatic intra-/extraarticular impingement. Mean patient followup was 8 years (range, 5-13 years), and complete followup was available in 38 patients (39 hips [95%]). We evaluated pain and function with the impingement test, limp, abductor force, Merle d'Aubigné-Postel score, and range of motion. Radiographic parameters included trochanteric height, alpha angle, and progression of OA. Subsequent surgeries, complications, and conversion to THA were summarized. RESULTS The proportion of positive anterior impingement tests decreased from 93% (38 of 41 hips) preoperatively to 49% (17 of 35 hips) at latest followup (p = 0.002); the proportion of limp decreased from 76% (31 of 41 hips) to 9% (three of 35 hips; p < 0.001); the proportion of normal abductor strength increased from 17% (seven of 41 hips) to 91% (32 of 35 hips; p < 0.001); mean Merle d'Aubigné-Postel score increased from 14 ± 1.7 (range, 9-17) to 17 ± 1.5 (range, 13-18; p < 0.001); mean internal rotation increased to 25° ± 15° (range, 0°-60°; p = 0.045), external rotation to 32° ± 14° (range, 5°-70°; p = 0.013), and abduction to 37° ± 13° (range, 10°-50°; p = 0.004). Eighty percent of hips (33 of 41 hips) showed normal trochanteric height; alpha angle improved to 42° ± 10° (range, 27°-90°). Two hips (5%) had subsequent surgeries as a result of lack of containment; four of 41 hips (10%) had complications resulting in reoperation. Fourteen of 35 hips (40%) showed progression of OA; four of 40 hips (10%) converted to THA. CONCLUSIONS Relative femoral neck lengthening in hips with combined intra- and extraarticular impingement results in reduced pain, improved function, and improved radiographic parameters of the proximal femur. Although lack of long-term complications is gratifying, progression of OA was not prevented and remains an area for future research.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND In some hips with cam-type femoroacetabular impingement (FAI), we observed a morphology resembling a more subtle form of slipped capital femoral epiphysis (SCFE). Theoretically, the morphology in these hips should differ from hips with a primary cam-type deformity. QUESTIONS/PURPOSES We asked if (1) head-neck offset; (2) epiphyseal angle; and (3) tilt angle differ among hips with a slip-like morphology, idiopathic cam, hips after in situ pinning of SCFE, and normal hips; and (4) what is the prevalence of a slip-like morphology among cam-type hips? METHODS We retrospectively compared the three-dimensional anatomy of hips with a slip-like morphology (29 hips), in situ pinning for SCFE (eight hips), idiopathic cam deformity (171 hips), and 30 normal hips using radial MRI arthrography. Normal hips were derived from 17 asymptomatic volunteers. All other hips were recruited from a series of 277 hips (243 patients) seen at a specialized academic hip center between 2006 and 2010. Forty-one hips with isolated pincer deformity were excluded. Thirty-six of 236 hips had a known cause of cam impingement (secondary cam), including eight hips after in situ pinning of SCFE (postslip group). The 200 hips with a primary cam were separated in hips with a slip-like morphology (combination of positive fovea sign [if the neck axis did not intersect with the fovea capitis] and a tilt angle [between the neck axis and perpendicular to the basis of the epiphysis] exceeding 4°) and hips with an idiopathic cam. We evaluated offset ratio, epiphyseal angle (angle between the neck axis and line connecting the center of the femoral head and the point where the physis meets the articular surface), and tilt angle circumferentially around the femoral head-neck axis. Prevalence of slip-like morphology was determined based on the total of 236 hips with cam deformities. RESULTS Offset ratio was decreased anterosuperiorly in idiopathic cam, slip-like, and postslip (eg, 1 o'clock position with a mean offset ranging from 0.00 to 0.14; p < 0.001 for all groups) compared with normal hips (0.25 ± 0.06 [95% confidence interval, 0.13-0.37]) and increased posteroinferiorly in slip-like (eg, 8 o'clock position, 0.5 ± 0.09 [0.32-0.68]; p < 0.001) and postslip groups (0.55 ± 0.12 [0.32-0.78]; p < 0.001) and did not differ in idiopathic cam (0.32 ± 0.09 [0.15-0.49]; p = 0.323) compared with normal (0.31 ± 0.07 [0.18-0.44]) groups. Epiphyseal angle was increased anterosuperiorly in the slip-like (eg, 1 o'clock position, 70° ± 9° [51°-88°]; p < 0.001) and postslip groups (75° ± 13° [49°-100°]; p = 0.008) and decreased in idiopathic cam (50° ± 8° [35°-65°]; p < 0.001) compared with normal hips (58° ± 8° [43°-74°]). Posteroinferiorly, epiphyseal angle was decreased in slip-like (eg, 8 o'clock position, 54° ± 10° [34°-74°]; p < 0.001) and postslip (44° ± 11° [23°-65°]; p < 0.001) groups and did not differ in idiopathic cam (76° ± 8° [61°-91°]; p = 0.099) compared with normal (73° ± 7° [59°-88°]) groups. Tilt angle increased in slip-like (eg, 2/8 o'clock position, 14° ± 8° [-1° to 30°]; p < 0.001) and postslip hips (29° ± 10° [9°-48°]; p < 0.001) and decreased in hips with idiopathic cam (-7° ± 5° [-17° to 4°]; p < 0.001) compared with normal (-1° ± 5° [-10° to 8°]) hips. The prevalence of a slip-like morphology was 12%. CONCLUSIONS The slip-like morphology is the second most frequent pathomorphology in hips with primary cam deformity. MRI arthrography of the hip allows identifying a slip-like morphology, which resembles hips after in situ pinning of SCFE and distinctly differs from hips with idiopathic cam. These results support previous studies reporting that SCFE might be a risk factor for cam-type FAI.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES To examine whether circulating levels of matrix metalloproteinase 9 (MMP-9) were associated with ultrasound-assessed intima-media thickness (IMT) and echolucent plaques in the carotid and femoral arteries. To examine preanalytical sources of variability in MMP-9 concentrations related to sampling procedures. SUBJECTS AND DESIGN Plasma and serum MMP-9 levels were compared with ultrasound assessed measures of femoral and carotid atherosclerosis, in a cross-sectional study of 61-year-old men (n = 473). Preanalytical sources of variability in MMP-9 levels were examined in 10 healthy subjects. Main outcome measures were circulating levels of MMP-9 in serum and plasma, IMT of the carotid and femoral arteries, and plaque status based on size and echolucency. SETTING Research unit at university hospital. RESULTS Plasma concentrations of total and active MMP-9 were associated with femoral artery IMT independently of traditional cardiovascular risk factors, and were higher in subjects with moderate to large femoral plaques. Plasma MMP-9 concentration was higher in men with echolucent femoral plaques (P = 0.006) compared with subjects without femoral plaques. No similar associations were found for carotid plaques. MMP-9 concentrations were higher in serum than in plasma, and higher when sampling was performed with Vacutainer than with syringe. MMP-9 levels in serum were more strongly associated with peripheral neutrophil count compared with MMP-9 levels in plasma. CONCLUSIONS Plasma MMP-9 levels were associated with atherosclerosis in the femoral artery, and total MMP-9 concentration was higher in men with echolucent femoral plaques. The choice of sample material and sampling method affect the measurements of circulating MMP-9 levels.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES The aim of the study was to test the hypothesis that circulating markers of inflammation (high-sensitive C-reactive protein, hsCRP) and oxidative modification of lipids (oxidized low-density lipoprotein, oxLDL) were associated with the occurrence of echolucent rather than echogenic femoral artery plaques in a cross-sectional population based cohort of 513, 61-year-old men. BACKGROUND The relationships between circulating oxLDL, hsCRP and the occurrence of echolucent plaques in the femoral artery have not previously been investigated. METHODS The levels of circulating oxLDL and hsCRP were determined in plasma by ELISA. Plaque occurrence, size and echogenicity were measured by B-mode ultrasound in the right femoral artery. Assessment of plaque echogenicity was based on the classification (grades 1-4) proposed by Gray-Weale et al. RESULTS A higher frequency of echolucent femoral plaques was observed in subjects with the metabolic syndrome and current smokers (p=0.01 and p<0.001, respectively) as well as with increasing levels of oxLDL and hsCRP (p=0.002 and p=0.005, respectively). In a multiple logistic regression analysis oxLDL and current smokers turned out to be independent associated with the presence of echolucent femoral artery plaques. CONCLUSIONS The results of the present study support our hypothesis that circulating oxLDL is a marker of an unstable echolucent plaque phenotype in the femoral artery in man.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hip dysplasia is characterized by insufficient femoral head coverage (FHC). Quantification of FHC is of importance as the underlying goal of the surgery to treat hip dysplasia is to restore a normal acetabular morphology and thereby to improve FHC. Unlike a pure 2D X-ray radiograph-based measurement method or a pure 3D CT-based measurement method, previously we presented a 2.5D method to quantify FHC from a single anteriorposterior (AP) pelvic radiograph. In this study, we first quantified and compared 3D FHC between a normal control group and a patient group using a CT-based measurement method. Taking the CT-based 3D measurements of FHC as the gold standard, we further quantified the bias, precision and correlation between the 2.5D measurements and the 3D measurements on both the control group and the patient group. Based on digitally reconstructed radiographs (DRRs), we investigated the influence of the pelvic tilt on the 2.5D measurements of FHC. The intraclass correlation coefficients (ICCs) for absolute agreement was used to quantify interobserver reliability and intraobserver reproducibility of the 2.5D measurement technique. The Pearson correlation coefficient, r, was used to determine the strength of the linear association between the 2.5D and the 3D measurements. Student's t-test was used to determine whether the differences between different measurements were statistically significant. Our experimental results demonstrated that both the interobserver reliability and the intraobserver reproducibility of the 2.5D measurement technique were very good (ICCs > 0.8). Regression analysis indicated that the correlation was very strong between the 2.5D and the 3D measurements (r = 0.89, p < 0.001). Student's t-test showed that there were no statistically significant differences between the 2.5D and the 3D measurements of FHC on the patient group (p > 0.05). The results of this study provided convincing evidence demonstrating the validity of the 2.5D measurements of FHC from a single AP pelvic radiograph and proved that it could serve as a surrogate for 3D CT-based measurements. Thus it may be possible to use this method to avoid a CT scan for the purpose of estimating 3D FHC in diagnosis and post-operative treatment evaluation of patients with hip dysplasia.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE The present study aimed at the comparison of body height estimations from cadaver length with body height estimations according to Trotter and Gleser (1952) and Penning and Riepert (2003) on the basis of femoral F1 section measurements in post-mortem computed tomography (PMCT) images. METHODS In a post-mortem study in a contemporary Swiss population (226 corpses: 143 males (mean age: 53±17years) and 83 females (mean age: 61±20years)) femoral F1 measurements (403 femora: 199 right and 204 left; 177 pairs) were conducted in PMCT images and F1 was used for body height estimation using the equations after Trotter and Gleser (1952, "American Whites"), and Penning and Riepert (2003). RESULTS The mean observed cadaver length was 176.6cm in males and 163.6cm in females. Mean measured femoral length F1 was 47.5cm (males) and 44.1cm (females) respectively. Comparison of body height estimated from PMCT F1 measurements with body height calculated from cadaver length showed a close congruence (mean difference less than 0.95cm in males and less than 1.99cm in females) for equations both applied after Penning and Riepert and Trotter and Gleser. CONCLUSIONS Femoral F1 measurements in PMCT images are very accurate, reproducible and feasible for body height estimation of a contemporary Swiss population when using the equations after Penning and Riepert (2003) or Trotter and Gleser (1952).

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador: