943 resultados para Wound depth
Resumo:
To compare the effect of hyaluronic acid (HA) and of AG on the healing of intestine wounds. Methods: The semi-purified extract of the eggs of the mollusc was obtained by fractionation with ammonium sulfate and purification for ion-exchange chromatography. The obtained galactans were eluted in water (neutral galactan) and in 0.1 and 0.2M NaCl (acidic galactans). The in vivo study was performed with 45 “Wistar” rats, separated in three groups (n=15). Solutions containing HA 1%, GA 1% or saline solution 0,9%, was placed topically on the sutures of wounds in the small intestine of the rats. After 05, 10 and 21 days the animals were sacrificed and biopsy of the healing tissue was done. Results: The hystologic grading was more significant for HA and AG groups when compared to the group C. AG stimulated the appearance of macrophages, giant cells and increase in the concentration of collagen in the area of the wound when compared to HA. Conclusion: The topical use of GA in intestinal wounds promoted the anticipation of events that are important in the wound healing
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The stretch zone width (SZW) data for 15-5PH steel CTOD specimens fractured at -150 degrees C to + 23 degrees C temperature were measured based on focused images and 3D maps obtained by extended depth-of-field reconstruction from light microscopy (LM) image stacks. This LM-based method, with a larger lateral resolution, seems to be as effective for quantitative analysis of SZW as scanning electron microscopy (SEM) or confocal scanning laser microscopy (CSLM), permitting to clearly identify stretch zone boundaries. Despite the worst sharpness of focused images, a robust linear correlation was established to fracture toughness (KC) and SZW data for the 15-5PH steel tested specimens, measured at their center region. The method is an alternative to evaluate the boundaries of stretched zones, at a lower cost of implementation and training, since topographic data from elevation maps can be associated with reconstructed image, which summarizes the original contrast and brightness information. Finally, the extended depth-of-field method is presented here as a valuable tool for failure analysis, as a cheaper alternative to investigate rough surfaces or fracture, compared to scanning electron or confocal light microscopes. Microsc. Res. Tech. 75:11551158, 2012. (C) 2012 Wiley Periodicals, Inc.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Objective-To evaluate the correlation between the bispectral index (BIS) and end-tidal isoflurane (ETISO) concentration and compare the use of 3 BIS sensor positions in dogs.Animals-6 adult dogs.Procedures-Mechanically ventilated dogs received pancuronium, and depth of anesthesia was altered by increasing ETISO concentration from 1.5% to 2.3% and 3.0%. The BIS, suppression ratio (relative percentage of isoelectric electroencephalographic waveforms), and signal quality index (SQI) were recorded at each ET, so concentration for each of 3 BIS sensor positions (frontal-occipital, bifrontal, and frontal-temporal positions).Results-The BIS and ETISO concentration were poorly correlated-, regardless of sensor positioning, mean BIS values did not change significantly as ETISO was increased. At 3% isoflurane, regardless of sensor positioning, there was an increase in suppression ratio coincident with BIS < 40 in some dogs, whereas paradoxic increases in BIS (> 60) were recorded in others. Furthermore, at 3.0% isoflurane, the SQI was significantly lower for the bifrontal sensor position (compared with values for the other positions), but low SQI values prevented recording of BIS values from the frontal-occipital sensor position in 2 dogs. Overall, BIS values derived from the 3 sensor positions did not differ.Conclusions and Clinical Relevance-In dogs, BIS values may not reflect changes in depth of isoflurane anesthesia in the absence of noxious stimulation. of the 3 sensor positions, frontal-temporal positioning provided better correlation with changes in depth of anesthesia induced via changes in isoflurane concentrations. However, the sensor placements yielded similar results at SQI values > 50.
Resumo:
This article describes an alternative surgical approach to the harvesting of subepithelial connective tissue grafts from thin palates. A partial-thickness flap is raised, and a graft composed of epithelium and connective tissue is removed from the palate. The superficial layer ( epithelium and a thin zone of connective tissue) is then dissected from the graft and replaced at the donor site to facilitate faster healing. The subjacent layer of connective tissue is placed as needed to obtain root coverage. The clinical application of this technique is described in two patients with multiple gingival recessions.
Resumo:
Low-level laser therapy (LLLT) has been shown to have several biological effects that favor the healing process, and nicotine has been shown to delay the healing process. In this study we investigated the healing of open wounds created on the back of rats treated with nicotine with or without LLLT. of 115 animals, 59 received subcutaneous injections of saline solution, and the others received subcutaneous injections of nicotine (3 mg/kg body weight), twice a day throughout the study period. After 30 days, skin wounds were created on the back of the animals. The animals receiving saline injections were divided into two groups: group 1 (G1, n = 29), in which the wounds were left untreated, and group 2 (G2, n = 30), in which the wounds were treated with LLLT (GaAlAs, 660 nm, 30 mW, 5.57 J/cm(2) per point, 0.39 J, 13 s per point, 0.42 W/cm(2)). The animals receiving nicotine injections were also divided into two groups: group 3 (G3, n = 29), in which the wounds were left untreated, and group 4 (G4, n = 27), in which the wounds were treated with LLLT. The animals were killed 3, 7 or 14 days after surgery. Wound healing was evaluated histologically both qualitatively and semiquantitatively. Wounds of G2 showed a delay in epithelial migration and connective tissue organization compared to those of G1. Wounds of G2 showed faster healing than those of G1; similarly, wounds of G4 showed more advanced healing than those of G3. LLLT acted as a biostimulatory coadjuvant agent balancing the undesirable effects of nicotine on wound tissue healing.
Resumo:
The aim of this in vitro study was to evaluate the relationship between laser fluorescence values and sealant penetration depth on occlusal fissures. One hundred and sixty-six permanent molars were selected and divided into four groups, which were each treated using a different sealant (two clear and two opaque). The teeth were independently measured twice by two experienced dentists using two laser fluorescence devices-DIAGNOdent (LF and LFpen)-before and after sealing, and then thermoclycled. After measuring, the teeth were histologically prepared and assessed for caries extension. Digital photographs of the cut sealed sites were assessed, and the sealant penetration depth was measured. All 166 sites were measured by one of the examiners taking as limits the outer and inner surface of the sealant into the fissure. For each device (LF and LFpen) and each group, the difference between the values at baseline and after sealing was plotted against the sealant penetration depth and scatter plots were provided. It could be observed that most of the points were concentrated around the zero line, for both LF and LFpen in the four groups. In conclusion, there is no relation between changes in DIAGNOdent values and increasing of depth sealant penetration within the occlusal fissures.
Resumo:
The purpose of this study was to evaluate the polymerization effectiveness of a composite resin (Z-250) utilizing microhardness testing. In total, 80 samples with thicknesses of 2 and 4 mm were made, which were photoactivated by a conventional halogen light-curing unit, and light-curing units based on LED. The samples were stored in water distilled for 24 h at 37C. The Vickers microhardness was performed by the MMT-3 microhardness tester. The microhardness means obtained were as follows: G1, 72.88; G2, 69.35; G3, 67.66; G4, 69.71; G5, 70.95; G6, 75.19; G7, 72.96; and G8, 71.62. The data were submitted to an analysis of variance (ANOVA's test), adopting a significance level of 5%. The results showed that, in general, there were no statistical differences between the halogen and LED light-curing units used with the same parameters.