Radon levels in two old mines in San Luis, Argentina, are reported and analyzed. The radiation dose and environmental health risk of (222)Rn concentrations to both guides and visitors were estimated. CR-39 nuclear track detectors were used for this purpose. The values for the (222)Rn concentration at each monitoring site ranged from 0.43 +/- 0.04 to 1.48 +/- 0.12 kBq m(-3) in the Los Cndores wolfram mine and from 1.8 +/- 0.1 to 6.0 +/- 0.5 kBq center dot m(-3) in the La Carolina gold mine, indicating that, in this mine, the radon levels exceed up to four times the action level of 1.5 kBq m(-3) recommended by the International Commission on Radiological Protection. The patterns of the radon transport process revealed that the La Carolina gold mine can be interpreted as a gas confined into a single tube with constant cross-section and air velocity. Patterns of radon activity, taking into account the chimney-effect winds, were used to detect tributary currents of air from shafts or larger fissures along the main adit of the Los Cndores mine, showing that radon can be used as an important tracer of tributary air currents stream out from fissures and smaller voids in the rock of the mine.
Resumo:
A partir dos objetivos propostos pelas políticas nacionais de saúde, ambientais e de saneamento básico buscou-se analisar os efeitos da cobrança pelo uso da água no setor de saneamento básico, visando identificar possíveis variações causadas por este instrumento econômico no acesso à água, na qualidade do produto ofertado e na qualidade do serviço prestado. Ainda, por se tratar de um serviço público, analisamos a performance técnica das empresas paulistas do setor de saneamento básico na prestação deste serviço por meio da metodologia Data Envelopment Analysis. Esta ferramenta resulta em um indicador de desempenho, com base na melhor relação input/output, ao estabelecer um ranking de eficiência médio a partir das práticas mais eficientes de cada unidade produtiva.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The market-assisted land reform (RAAM) has been constituted as an alternative of agrarian reform funded by the Programa Nacional do Crédito Fundiário (PNCF). It is a policy of acquisition, distribution and use of Earth ideologically disseminated and funded by the World Bank in the context of productive insertion of landless workers. Accordingly, this study seeks to analyze the trajectory of rural settlements financed by this policy, seeking to understand what factors promote or limit the process of rural development of those settlements. To do so, take as a reference case study of the Assentamento da Fazenda Paz, in the municipality of Maxaranguape in the State of Rio Grande do Norte. From the methodological point of view, bibliographical and documentary research were used, in addition to visits to the settlement and semi-structured interviews with the settlers, trade union leaders, consultants and technicians linked to the project. Assuming the reports of respondents, initially constructs the hypothesis that informal and formal institutions present in the Assentamento da Fazenda Paz were unable to effectively coordinate the actions of the agents. The results obtained showed the existence of a very complex undertaking, with a total area of 607 hectares and 80 families settled, endowed with good quality water and irrigation infrastructure, with assets of approximately R$ 5 million reais. Experience experienced by the settlers understood the development of complex systems of production and marketing of fruits and vegetables, with an emphasis on the cultivation of papaya in an area of 45 hectares based on modern irrigation system and extensive use of technology. Collective management of production, marketing, revenue and costs stood out as a major challenge for the settlers and their representative organisations, i.e. the Community Association and the cooperative. From this observation it was possible to identify two moments on the trajectory of the project: the first, between 2007-2011, considered by respondents as successful, in which the integration of public policies and abundant input of revenue from the commercialization of the fruits da Paz, mainly through the sale of papaya and pineapple in national and international markets, allowed an average remuneration of R$ 800.00 reais to R$ 1,000 reais seated/monthIn addition to the production of vegetables and other types of products for sale and consumption; the second, from 2012, characterized as a failure, due to the discontinuity of the cultivation, production and marketing of fruits based on the collective bargaining model deployed. Important factors explain the discontinuity of the project, including the model of agriculture implemented, difficulties related to the management of production, marketing and finance the venture, in addition to the breach of trust between the Board of the cooperative and the associates and the distancing of the governmental organizations more directly responsible for the project. It is therefore concluded that we must to rethink rural development as a multidimensional phenomenon, requiring a broad engagement between State and society under the foundations of a territorial development contract
Resumo:
In this paper, a multi-objective approach for observing the performance of distribution systems with embedded generators in the steady state, based on heuristic and power system analysis, is proposed. The proposed hybrid performance index describes the quality of the operating state in each considered distribution network configuration. In order to represent the system state, the loss allocation in the distribution systems, based on the Z-bus loss allocation method and compensation-based power flow algorithm, is determined. Also, an investigation of the impact of the integration of embedded generators on the overall performance of the distribution systems in the steady state, is performed. Results obtained from several case studies are presented and discussed. Copyright (C) 2004 John Wiley Sons, Ltd.
Resumo:
Optimised placement of control and protective devices in distribution networks allows for a better operation and improvement of the reliability indices of the system. Control devices (used to reconfigure the feeders) are placed in distribution networks to obtain an optimal operation strategy to facilitate power supply restoration in the case of a contingency. Protective devices (used to isolate faults) are placed in distribution systems to improve the reliability and continuity of the power supply, significantly reducing the impacts that a fault can have in terms of customer outages, and the time needed for fault location and system restoration. This paper presents a novel technique to optimally place both control and protective devices in the same optimisation process on radial distribution feeders. The problem is modelled through mixed integer non-linear programming (MINLP) with real and binary variables. The reactive tabu search algorithm (RTS) is proposed to solve this problem. Results and optimised strategies for placing control and protective devices considering a practical feeder are presented. (c) 2007 Elsevier B.V. All rights reserved.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
In most of the cases, the systems of water distribution from groundwater wells use electrical submersible pumps. All electrical energy is applied to the pumps; however, other components (pipes, valves, etc.) of these systems are also responsible by the higher or lower consumption of electric energy. The supervisors and operators of the systems should thus have knowledge of the global energetic behavior of the process in order to administrate it properly. This work suggests a 'Global Energetic Efficiency Indicator' for groundwater wells by using mathematical equations and neural networks. Simulation results will be presented in order to demonstrate the validity of the proposed approach.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
In this paper, it is presented a methodology for three-phase distribution transformer modeling, considering several types of transformer configuration, to be used in algorithms of power flow in three-phase radial distribution networks. The paper provides a detailed discussion about the models and the results from an implementation of the power flow algorithm. The results, taken from three different networks, are presented for several transformer configurations and for voltage regulators as well.
Resumo:
Objectives: To investigate the relationships between socio-demographic factors, infant feeding habits, oral hygiene and the prevalence and patterns of caries in Brazilian 3-4-year-olds. Methods: Systematic random sampling was used to select children enrolled in municipal nurseries in Araraquara, Brazil, in 1998. Clinical examinations were carried out by one examiner using dmft and dmfs indices and WHO criteria. Questionnaires for information related to the socio-demographic background, oral hygiene and dietary history of the children were completed by their mothers. Results: Caries was seen in 46% of the children; 17% of them had the more extensive pattern involving molars and incisors. Social class, mother's education, and age at which breast-feeding terminated showed statistically significant associations with caries. Feeding bottles with added sugars were still being given to 80% of the children. When the significant variables were taken into account only age at which breast-feeding terminated showed a significant relationship to the pattern of disease. Children who were never breast-fed or were breast-fed beyond the age of 24 months had a higher prevalence of the more extensive pattern of caries. Conclusions: The association between the length of time a mother breast-feeds and extensive caries should be a consideration in any local infant feeding policies or health promotion strategies. The duration for appropriate breast- or bottle-feeding should be emphasised.
Resumo:
Since the 80s huge efforts have been made to utilize renewable energy sources to generate electric power. An important issue about using renewable energy sources is a Distribution Management System (DMS) in presence of dispersed generators. This paper reports some aspects of integration of the dispersed generators in the DMS. Besides, an investigation of impact of the dispersed generators on the overall performances of the distribution systems in steady state is performed. In order to observe losses in the distribution networks with dispersed generators, several loss allocation methods are applied. Results obtained from case study using IEEE test network, are presented and discussed. © 2003 IEEE.
Resumo:
Three-phase three-wire power flow algorithms, as any tool for power systems analysis, require reliable impedances and models in order to obtain accurate results. Kron's reduction procedure, which embeds neutral wire influence into phase wires, has shown good results when three-phase three-wire power flow algorithms based on current summation method were used. However, Kron's reduction can harm reliabilities of some algorithms whose iterative processes need loss calculation (power summation method). In this work, three three-phase three-wire power flow algorithms based on power summation method, will be compared with a three-phase four-wire approach based on backward-forward technique and current summation. Two four-wire unbalanced medium-voltage distribution networks will be analyzed and results will be presented and discussed. © 2004 IEEE.
Resumo:
This paper presents a new methodology to evaluate in a predictive way the reliability of distribution systems, considering the impact of automatic recloser switches. The developed algorithm is based on state enumeration techniques with Markovian models and on the minimal cut set theory. Some computational aspects related with the implementation of the proposed algorithm in typical distribution networks are also discussed. The description of the proposed approach is carried out using a sample test system. The results obtained with a typical configuration of a Brazilian system (EDP Bandeirante Energia S.A.) are presented and discussed.